Tender For Special Repair To Pumpset And Allied Works At 9Brd Afs Pune And Certain Minor Works At Wsa And 2Wing Afs Pune Under Ge Af Lohegaon
Tender Value
23.40 Lakhs
Estimated cost
Bid Submission
09 Sep 2026
15 days left
EMD
46800
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repair To Pumpset And Allied Works At 9Brd Afs Pune And Certain Minor Works At Wsa And 2Wing Afs Pune Under Ge Af Lohegaon
BOQ
| Sl. No. | Item Description |
| 1 | Supply, Install, testing and commissioning of pumping sets, centrifugal, electric driven, capacity 40 HP having discharge 32.5 Lps, head 58 Metres with fully automatic Stat delta Starter of suitable capacity including taking down of Old pumpset, dimantling suction & delivery pipes and depositing to MES store yard including material & Labour for making the Foundation and Base frame for Fixing the Motor complete all as specified and directed by Engineer In Charge |
| 2 | Supply & lay and jointing tubing heavy grade galvanised iron pipes, ISI marked with all fittings such as bends, tees, elbows, nipple, unions, short pieces, sockets etc and laid in trenches all as specified of following sizes :- |
| 3 | 100mm dia bore |
| 4 | 150mm dia bore |
| 5 | Taking out and S&F unserviceable CI sluice valve from exisiting position by opening the nuts , bolts and breaking of valve chamber including necessary earth work and excvation in any type of soil and S & F CI sluice valve with PN rating 1.6 conforming to IS 14846 duly ISI marked with iron wheel head HSS spindle and all other conected accessories such as gland packing, bolts, and nuts rubber gasket etc complete and making good the vlave chamber to match with the adjacent surface including brick / PCC block works, plastering etc for the following sizes complete all as directed . |
| 6 | 100 mm bore |
| 7 | 150 mm bore |
| 8 | 200 mm bore |
| 9 | M & L DI water pipes with spigot and socket ends including rubber gasket joint Class K 7, in any length, laid in trenches. |
| 10 | 100 mm bore |
| 11 | 150 mm bore |
| 12 | 200 mm bore |
| 13 | Supply & Fixing Foot Valve Confirming to IS 4038 of size 100 mm dia ball type incl rubber gasket, strainer, bolts, buts complete all as directed. |
| 14 | Supply & Fixing Foot Valve Confirming to IS 4038 of size 150 mm dia ball type incl rubber gasket,strainer, bolts, buts complete all as directed. |
| 15 | Supply, Installation, testing & commissioning Self Priming Non clogging sewage Pumping sets, having discharge 500 LPM, with Head 10 meter, with CI Casing, SS Impeller, SS Shaft, mechanical seal & Cutter coupled with suitable rating induction motor including making foundation, suitable starter. |
| 16 | Supply & Fixing Heavy duty flexible Kanaflex pipe of size 100mm along with MS clamps and nut bolts with all fiiting complete all as specified and directed by Engr-in-Charge. |
| 17 | Supply install, test and commissioning floor mounted LT Panel board (CPRI Approved) Powder coated cubical type outdoor factory fabricated made out of 3 mm thick CRCA sheet & suitable size to accomodate all accessories/fittings, compartmentalized in construction to accommodate all acessories. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. A detachable predrilled powder coated gland plateshould be used at the bottom for entry of armoured cable of adequate size with glands.Including steel stand made out of ange iron of size 50 mm X 50 mmX 6 mm and of height 60mm. The above panel shall be front openable lockable /openable by key from both side and shall have louvers and air vent gasket for natural flow of air. |
| 18 | i) Copper bus bar 3 phase 4 wire suitable for 100 amps capacity along with PVC sleevs - 1 Setii) MCB 63 Amps - 1 Nos (Incomer) iii) TPN 32 Amps - 3 Nos iv) Space of 2 Nos Starter - 2 Nosviii) Indicating Lamps LED Type -03 NosNote: Starter under item No 1 shall be fixed in panel. |
| 19 | Supply & Fixing PVC weather proof cable and replacement with new PVC weather proof copper cable for size 3 core 2.5 sqmm suitable for Self priming Non clogging sewage pumpset complete all as directed by Engr-in-Charge. |
| 20 | M & L Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion |
| 21 | Supply and laying in trenches or fixing to wall/pole or passing through pipe PVC insulated heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 16 Sqmm 4 core. |
| 22 | Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole in soft/loose soil etc complete all as specified and directed by Engr-in-Charge. |
| 23 | Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole in hard/dense soil complete all as specified and directed by Engr-in-Charge. |
| 24 | Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole in soft disintegrated rock complete all as specified and directed by Engr-in-Charge. |
| 25 | Returning, filling in, including spreading, leveling watering, and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified and directed by Engr-in-Charge. |
| 26 | Removing excavated material n.exc 50m and depositing where directed at a level exc. 1.5 cm above the starting point complete all as specified and directed by Engr-in-Charge. |
| 27 | Supply and fix double walled corrugated pipe class SN4 50 mm inner dia including coupler and laying in ground and fix along the wall as per direction of Engr-In-Charge. |
| 28 | Material and labour for providing point wiring with two runs of 1.5 Sqmm multi stranded copper conductor FRLSH PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core multi stranded copper conductor FRLSH PVC insulated 1100 Volts grade wire for continuous earthing complete in and including PVC casing and caping with all fittings/fixture etc and open type Plastic Enclosure( Plastic Switch Board ) ISI Marked for housing switches / sockets all a specified and directed |
| 29 | (b) One Fan point controlled by one regulator/switch. |
| 30 | Supply and fix switch piano flush type 5 Amp one way. (ISI marked) |
| 31 | Supply and fix ceiling rose surface type bakelite / PVC three terminal 65 x 50mm. |
| 32 | Supply and fix wall mounted fan 400 mm Sweep and other fixing accessories as per requirement at site |
| 33 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 300 sq mm 3.5 core including cable lugs and heat shrinkable sleeve in panel completet all as specified and directed. |
| 34 | AMF Panel :- Control cubical fabricated from 3 MM thick CRCA Sheet duly pretreated & powder coated finish with iron angle base frame Support floor mounted with removable gland plates, hinged front & back openable door with locking arrangement and provison for connecting incoming and outgoing cable leads and the following accessories :(a) Al bus, bar, 3 phase, 4 wire, 500 Amps - 01 Set(b) AMF Controller including electrical wiring, Control MCB, Fuses etc, having auto/Manual mode selector switch, Engine Start & Stop Button, LCD display to indicate Engine & Alternator Paramaters - 1 Set(c) MCCB 500 Amps, Four Pole, 35 KA, 415 Volts - 2 Nos (d) Power contactor 4 pole 500 Amps - 02 Nos (e) Auto Manual Selector Switch with wiring - 1 Set(f) DG set ON/OFF Push Button - 1 Set(g) Control ON/OFF Selector Switch - 1 No(h) AC / DC relay & timers (j) O/L relay (k) CTs Set of 3 - 2 Set(l) Load on DG Indicator - 1 No(m) Load on Mains Indicator - 1 No(n) Mains ON Indicator - 1 No(o) DG ON Indicator - 1 No(p) Digital VAFPAF meter : 01 Nos (q) Supply and lay Control cable LT 1100 Volt PVC insulated armoured heavy duty copper conductor of suitable size multicore from DG Set to AMF panel(r) MCB, Connector, internal wiring as per OEM recommendation(g) Any other components/parts as per manufacturer instructions and as directed by GE required for entire completion of the item. |
| 35 | M&L for providing earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point, providing charcoal and common salt all as shown in electrical plate No. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including exaction/earth work in any type of strata PCC (1:3:6) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg/sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade and lugs, including galvanised iron strip 32x6 mm with GI protection pipe of 40 mm medium grade 7.5 meter long, etc complete all as specified. |
| 36 | M&L for cement concrete (1:2:4) type B1 in foundation filling and mass concrete incl necessary form work using 20 mm graded stone agg etc complete all as specified and directed by Engr-in-Charge |
| 37 | Supply and laying HDPE DWC pipe 135 mm inner dia SN8 incl coupler on wall/ along ground/ along channel/ in trench/under roof/ along pillar or as directed complete. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 09, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysSep 15, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender