Defence Statutory Bodies & Commissions/Committees Closing in 15 days TDR #57130266

Tender For Special Repair To Pumpset And Allied Works At 9Brd Afs Pune And Certain Minor Works At Wsa And 2Wing Afs Pune Under Ge Af Lohegaon

Issued by Statutory Bodies & Commissions/Committees · Pune, Maharashtra
Tender Value
23.40 Lakhs
Estimated cost
Bid Submission
09 Sep 2026
15 days left
EMD
46800
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repair To Pumpset And Allied Works At 9Brd Afs Pune And Certain Minor Works At Wsa And 2Wing Afs Pune Under Ge Af Lohegaon

BOQ

Name of Work:- SPECIAL REPAIR TO PUMPSET AND ALLIED WORKS AT 9BRD AFS PUNE AND CERTAIN MINOR WORKS AT WSA AND 2WING AFS PUNE UNDER GE AF LOHEGAON
Sl. No. Item Description
1Supply, Install, testing and commissioning of pumping sets, centrifugal, electric driven, capacity 40 HP having discharge 32.5 Lps, head 58 Metres with fully automatic Stat delta Starter of suitable capacity including taking down of Old pumpset, dimantling suction & delivery pipes and depositing to MES store yard including material & Labour for making the Foundation and Base frame for Fixing the Motor complete all as specified and directed by Engineer In Charge
2Supply & lay and jointing tubing heavy grade galvanised iron pipes, ISI marked with all fittings such as bends, tees, elbows, nipple, unions, short pieces, sockets etc and laid in trenches all as specified of following sizes :-
3100mm dia bore
4150mm dia bore
5Taking out and S&F unserviceable CI sluice valve from exisiting position by opening the nuts , bolts and breaking of valve chamber including necessary earth work and excvation in any type of soil and S & F CI sluice valve with PN rating 1.6 conforming to IS 14846 duly ISI marked with iron wheel head HSS spindle and all other conected accessories such as gland packing, bolts, and nuts rubber gasket etc complete and making good the vlave chamber to match with the adjacent surface including brick / PCC block works, plastering etc for the following sizes complete all as directed .
6100 mm bore
7150 mm bore
8200 mm bore
9M & L DI water pipes with spigot and socket ends including rubber gasket joint Class K 7, in any length, laid in trenches.
10100 mm bore
11150 mm bore
12200 mm bore
13Supply & Fixing Foot Valve Confirming to IS 4038 of size 100 mm dia ball type incl rubber gasket, strainer, bolts, buts complete all as directed.
14Supply & Fixing Foot Valve Confirming to IS 4038 of size 150 mm dia ball type incl rubber gasket,strainer, bolts, buts complete all as directed.
15Supply, Installation, testing & commissioning Self Priming Non clogging sewage Pumping sets, having discharge 500 LPM, with Head 10 meter, with CI Casing, SS Impeller, SS Shaft, mechanical seal & Cutter coupled with suitable rating induction motor including making foundation, suitable starter.
16Supply & Fixing Heavy duty flexible Kanaflex pipe of size 100mm along with MS clamps and nut bolts with all fiiting complete all as specified and directed by Engr-in-Charge.
17Supply install, test and commissioning floor mounted LT Panel board (CPRI Approved) Powder coated cubical type outdoor factory fabricated made out of 3 mm thick CRCA sheet & suitable size to accomodate all accessories/fittings, compartmentalized in construction to accommodate all acessories. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. A detachable predrilled powder coated gland plateshould be used at the bottom for entry of armoured cable of adequate size with glands.Including steel stand made out of ange iron of size 50 mm X 50 mmX 6 mm and of height 60mm. The above panel shall be front openable lockable /openable by key from both side and shall have louvers and air vent gasket for natural flow of air.
18i) Copper bus bar 3 phase 4 wire suitable for 100 amps capacity along with PVC sleevs - 1 Setii) MCB 63 Amps - 1 Nos (Incomer) iii) TPN 32 Amps - 3 Nos iv) Space of 2 Nos Starter - 2 Nosviii) Indicating Lamps LED Type -03 NosNote: Starter under item No 1 shall be fixed in panel.
19Supply & Fixing PVC weather proof cable and replacement with new PVC weather proof copper cable for size 3 core 2.5 sqmm suitable for Self priming Non clogging sewage pumpset complete all as directed by Engr-in-Charge.
20M & L Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion
21Supply and laying in trenches or fixing to wall/pole or passing through pipe PVC insulated heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 16 Sqmm 4 core.
22Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole in soft/loose soil etc complete all as specified and directed by Engr-in-Charge.
23Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole in hard/dense soil complete all as specified and directed by Engr-in-Charge.
24Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole in soft disintegrated rock complete all as specified and directed by Engr-in-Charge.
25Returning, filling in, including spreading, leveling watering, and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified and directed by Engr-in-Charge.
26Removing excavated material n.exc 50m and depositing where directed at a level exc. 1.5 cm above the starting point complete all as specified and directed by Engr-in-Charge.
27Supply and fix double walled corrugated pipe class SN4 50 mm inner dia including coupler and laying in ground and fix along the wall as per direction of Engr-In-Charge.
28Material and labour for providing point wiring with two runs of 1.5 Sqmm multi stranded copper conductor FRLSH PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core multi stranded copper conductor FRLSH PVC insulated 1100 Volts grade wire for continuous earthing complete in and including PVC casing and caping with all fittings/fixture etc and open type Plastic Enclosure( Plastic Switch Board ) ISI Marked for housing switches / sockets all a specified and directed
29(b) One Fan point controlled by one regulator/switch.
30Supply and fix switch piano flush type 5 Amp one way. (ISI marked)
31Supply and fix ceiling rose surface type bakelite / PVC three terminal 65 x 50mm.
32Supply and fix wall mounted fan 400 mm Sweep and other fixing accessories as per requirement at site
33Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 300 sq mm 3.5 core including cable lugs and heat shrinkable sleeve in panel completet all as specified and directed.
34AMF Panel :- Control cubical fabricated from 3 MM thick CRCA Sheet duly pretreated & powder coated finish with iron angle base frame Support floor mounted with removable gland plates, hinged front & back openable door with locking arrangement and provison for connecting incoming and outgoing cable leads and the following accessories :(a) Al bus, bar, 3 phase, 4 wire, 500 Amps - 01 Set(b) AMF Controller including electrical wiring, Control MCB, Fuses etc, having auto/Manual mode selector switch, Engine Start & Stop Button, LCD display to indicate Engine & Alternator Paramaters - 1 Set(c) MCCB 500 Amps, Four Pole, 35 KA, 415 Volts - 2 Nos (d) Power contactor 4 pole 500 Amps - 02 Nos (e) Auto Manual Selector Switch with wiring - 1 Set(f) DG set ON/OFF Push Button - 1 Set(g) Control ON/OFF Selector Switch - 1 No(h) AC / DC relay & timers (j) O/L relay (k) CTs Set of 3 - 2 Set(l) Load on DG Indicator - 1 No(m) Load on Mains Indicator - 1 No(n) Mains ON Indicator - 1 No(o) DG ON Indicator - 1 No(p) Digital VAFPAF meter : 01 Nos (q) Supply and lay Control cable LT 1100 Volt PVC insulated armoured heavy duty copper conductor of suitable size multicore from DG Set to AMF panel(r) MCB, Connector, internal wiring as per OEM recommendation(g) Any other components/parts as per manufacturer instructions and as directed by GE required for entire completion of the item.
35M&L for providing earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point, providing charcoal and common salt all as shown in electrical plate No. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including exaction/earth work in any type of strata PCC (1:3:6) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg/sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade and lugs, including galvanised iron strip 32x6 mm with GI protection pipe of 40 mm medium grade 7.5 meter long, etc complete all as specified.
36M&L for cement concrete (1:2:4) type B1 in foundation filling and mass concrete incl necessary form work using 20 mm graded stone agg etc complete all as specified and directed by Engr-in-Charge
37Supply and laying HDPE DWC pipe 135 mm inner dia SN8 incl coupler on wall/ along ground/ along channel/ in trench/under roof/ along pillar or as directed complete. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57130266
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 23.40 Lakhs
LAST DATE 09-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repair To Pumpset And Allied Works At 9Brd Afs Pune And Certain Minor Works At Wsa And 2Wing Afs Pune Under Ge Af Lohegaon
Basic Detail
Tender No 8117
Bidding Type Tender
Location
City Pune
State Maharashtra
Key Dates
Publish Date 21 Aug 2026
Submission Date 09 Sep 2026
Open Date 15 Sep 2026
Finance
Tender Value 23.40 Lakhs
Tender Fee 500
EMD 46800
Exemption Available
Document List
58cb6d8c-f9ad-4f89-bf80-9ab18f93ae1c.html
8117Merged.pdf
BOQ_880379.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Sep 15, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
html

58cb6d8c-f9ad-4f89-bf80-9ab18f93ae1c.html

pdf

8117Merged.pdf

xls

BOQ_880379.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders