Tender For Repair To Flooring, Dado, Internal Plastering, Sunken Floor Etc In Np, Rp & Mes Area At Af Station Halwara
Tender Value
35 Lakhs
Estimated cost
Bid Submission
12 Sep 2026
19 days left
EMD
70000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ludhiana → Punjab
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair To Flooring, Dado, Internal Plastering, Sunken Floor Etc In Np, Rp & Mes Area At Af Station Halwara
BOQ
| Sl. No. | Item Description |
| 1 | Demolition for cement conc exceeding 15cm thickness but above ground floor as sunken floor, complete all as specified and directed. |
| 2 | M&L for cement concrete type E-2, 1:5:10 (using 40 mm graded stone aggregate) as in sunken flooring, complete all as specified and directed. |
| 3 | M&L for applying two coats of water proofing coating on the entire surface of sunken portion, complete all as specified and directed. |
| 4 | M&L for 15mm thick cement screed in CM 1:3 admixed with integral water proofing compound @ 130ml per bag of cement incl a bonding coat of liquid @ 200ml per bag, complete all as specified and directed. |
| 5 | M&L for 25mm thick cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) in floor, complete all as specified and directed. |
| 6 | S&F 32mm dia GI pipe 450mm long beveled cut at both ends by making hole in walls sunken portion approx above the RCC slab and ceiling finished the hole with cement plaster 1:2 to match with existing surfaces, complete all as specified and directed. |
| 7 | Dismantling floor hearth or wall tiling including cement mortar bedding but not backing removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed. |
| 8 | M&L Glazed ceramic coloured tiles (300x450mm) x 7 mm / (300x200) x 7mm thick on vertical surfaces as in skirting/dado, set and jointed with neat cement slurry and pointed in white/coloured cement to match the shade of tiles over 10mm thick rendering in cement mortar 1:4, complete all as specified and directed. |
| 9 | M&L Non skid cerermic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tile exc 0.11 Sqm but not exc 0.18 Sqm, in neat cement slurry and pointed in white or coloured cement with pigment, complete all as specified and directed. |
| 10 | M&L Non skid cerermic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tile exc 0.18 Sqm but not exc 0.38 Sqm, in neat cement slurry and pointed in white or coloured cement with pigment, complete all as specified and directed. |
| 11 | M&L15mm thick screed bed or bedding layer of cement mortar (1:4) as in floor for laying floor tiles, complete all as specified and directed. |
| 12 | M&L15mm thick screed bed or bedding layer of cement mortar (1:4) with WPC as in floor for laying floor tiles, complete all as specified and directed. Note :- Water proofing compound shall be measured and paid separately. |
| 13 | Supply only integral waterproofing compound, complete all as specified and directed. |
| 14 | Taking up or down 15mm dia steel tubing and connections including cleaning for re-fixing or removal to store, complete all as specified and directed. |
| 15 | Taking up or down 20mm dia steel tubing and connections including cleaning for re-fixing or removal to store, complete all as specified and directed. |
| 16 | S&F CPVC pipes outer dia 16mm SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors (including all fittings), complete all as specified and directed. |
| 17 | S&F CPVC pipes outer dia 20mm SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors (including all fittings), complete all as specified and directed. |
| 18 | S & F in repairs fancy type bib tap cast copper alloy chromium plated screwed down high pressure with crutch or butterfly handle for iron pipe or brass ferrule and fixing of 15mm bore pipe, complete all as specified and as directed. |
| 19 | S&F as in repair 15mm Stop valves/angle valve, cast copper alloy,screwed down,high pressure,with crutch or butterfly handle,screwed bothends for iron pipe or for unions and fixed but fancy type, chromium plated with longshank and cup(concealed type), complete all as specified and directed. |
| 20 | S&F in repair vitreous china squatting pan Orissa pattern of size 580x440mm white with integral foot rest excluding flushing cistern and flush pipe complete including provn of cement concrete bedding, complete all as specified and directed. |
| 21 | S&F in repair PVC connection pipe 15 mm dia with PTMT nut for length 450 mm, complete all as specified and directed. |
| 22 | S&F in repair 10 ltr PVC valve less symphonic action type flushing cistern, low level white with inlet ball valve float and handle with flush pipe, complete all as specified and directed. |
| 23 | S&F in repair brass chromium plated shower rose 125 mm size with or without swivel joints ,any size,including fixing to steel pipe or union, complete all as specified and directed. |
| 24 | S & F in repair vitreous china wash hand basin white flat back size 550mmx400mm excluding, waste chaina and plug and porcelain stopper but including brackets, cutting for and pinning in ends of brackets or erecting stand , fancy type pillar taps cast copper alloy chromium plated of 15mm bore, waste coupling and waste pipe, (including cornor type if required), complete all as specified and directed. |
| 25 | S&F in repair Pillar taps 15 mm, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed but fancy type, complete all as specified and directed. |
| 26 | S&F in repair brass chromium plated tubular towel rail 20mm dia (D) type 60cm long between flanges, complete all as specified and directed. |
| 27 | S&F in repair glass shelf bathroom corner having radius 300mm min including fixing arrangement, complete all as specified and directed. |
| 28 | S&F in repair PVC bathroom cabinet mirror size 350mm x 450mm, complete all as specified and directed. |
| 29 | S&F in repair plastic water closet seat cover of White colour closed pattern with flat bottom and cover with mild steel chromium plated hinging device etc, complete all as specified and directed. |
| 30 | S&F in repair Health faucet (ABS body) mild steel chromium plated suitable for 15mm dia pipes with 1.25 m long flexible tube and ABS wall hook including making connections and fixed in position, complete all as specified and directed. |
| 31 | S&F in repair Stainless steel sink with draining board, made out of 1.00mm thick sheet for kitchen or laboratory with plug, washers waste pipe, cast iron cantilever brackets, connecting union overall size 915mmx460mm with bowl size 410mm x 330mm x 160mm, complete all as specified and directed. |
| 32 | S&F in repair Viterous China wash down water closet (pedestal pattern) white (excluding fixing bolts, flushing cistern and flush pipe), complete all as specified and directed. |
| 33 | S&F in repair 750 ltr rotational moulded polyethylene water storage tank (cylindrical vertical with closed top), tripple layer, white in colour hoisted including 20mm ball valve and fixed in position, complete all as specified and directed. |
| 34 | S&F in repair 500 ltr rotational moulded polyethylene water storage tank (cylindrical vertical with closed top), tripple layer, white in colour hoisted including 20mm ball valve and fixed in position, complete all as specified and directed. |
| 35 | S&F in repair PVC (SWR) pipes single socketed in any length with rubber ring joints, step clamps, including all fittings (any type of 'T'/tee ,bend,Y, Branch piece single/double, reducer , vent coil, access door, junction single/double, equal/unequal , any type of trap etc) 75mm dia fixed to walls/floor/trenches etc and height of building upto G+5, complete all as specified and directed. |
| 36 | S&F in repair PVC (SWR) pipes single socketed in any length with rubber ring joints, step clamps, including all fittings (any type of 'T'/tee ,bend,Y, Branch piece single/double, reducer, vent coil, access door, junction single/double, equal/unequal, any type of trap etc) 110 mm dia fixed to walls/floor/trenches etc and height of building upto G+5, complete all as specified and directed. |
| 37 | Demolition on reinforced cement concrete of any description and in any position not otherwise specficially provided for, complete all as specified and directed. |
| 38 | M&L for RCC(1:2:4), type B1 (using 20 mm graded stone aggregate) Precast cement concrete cover slab for tank staging, manhole cover and similar article with plain face, set in cement mortar 1:4, complete all as specified and directed. |
| 39 | Mild steel bars 10mm dia and over TMT bars cut to length bent to shape reqd including cranking ,bending spirally for hooping for columns hooking bends and binding with including mild steel wire (annealed) not-less than 0.9mm dia or securing with clips quality, complete all as specified and directed. |
| 40 | Cleaning and removing with bleaching powder to all scale, sludge, mud, algae and dirt etc from tanks capacity upto and including 1000 liters an from mouths of circulating pipes etc and washing with clean water including writing in words with synthetic enamel paint as CLEANED ON (date), complete all as specified and directed. |
| 41 | Taking down cement plaster of any description thickness including raking out joints hacking for key scrubbing down with water, complete all as specified and directed. |
| 42 | Demolition of brick work as in walls/parapet wall,s removing grass fungus weed, roots of trees completely, grown on roof/wall surfaces all as specified and , complete all as specified and directed. |
| 43 | M&L for Brick work with sub class ‘B’ brick, straight or curved as plan exc 6m mean radiusbuilt in cement mortar 1:6, complete all as specified and directed. |
| 44 | M&L for 12 mm thick cement mortar 1:6 on Brick or concrete surface finished even and smooth without using extra cement, complete all as specified and directed. |
| 45 | M&L for preparation of new surface of wall and applying two coats of distemper oil emulsion over a coat primer above 1mm thick plaster of paris putty on new surfaces, complete all as specified and directed. |
| 46 | M&L for complete removal of old decorated plastered & unplastered surfaces of walls by brooming down or steel wire brushing, scrapping down smoke soot, mould, moss and efflorescent salts, trading oil and greasy pots applying two coat of distemper oil emulsion over a coat primer above 1mm thick wall care putty, on old surfaces of wall, complete all as specified and directed. |
| 47 | M&L plastering 5 mm thick in cement mortar (1:3) furnished even & smooth without using extra cement as on ceiling, complete all as specified and directed. |
| 48 | M&L prepration of new surfaces of and applying three coats of white wash on ceiling, complete all as specified and directed. |
| 49 | M&L prepration of old surfaces and applying one coats of white wash on ceiling, complete all as specified and directed. |
| 50 | S&F in repairs 600x450mm bevelled edge mirror of selected quality glass mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washer, complete all as specified and directed. |
| 51 | M&L 75mm dia PVC floor trap/nahani trap with CP grating including jointing to waste pipe with cement solvent, complete all as specified and directed. |
| 52 | S&F PVC (SWR) vent cowl 75 mm dia, complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 12, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysSep 15, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender