Defence Statutory Bodies & Commissions/Committees Closing in 4 days TDR #57129249

Tender For Providing Of Compact Sub Stn (250 Kva Transformer) And Connected Items At Lower Dahung And 01 X 15 Kva Genr Set For Ee Mech Section Under Ge Tenga

Issued by Statutory Bodies & Commissions/Committees · siliguri, West Bengal
Tender Value
53 Lakhs
Estimated cost
Bid Submission
24 Sep 2026
4 days left
EMD
1.04 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
siliguri → West Bengal
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Providing Of Compact Sub Stn (250 Kva Transformer) And Connected Items At Lower Dahung And 01 X 15 Kva Genr Set For Ee Mech Section Under Ge Tenga

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 22-Aug-2026 CORRIGENDUM NO 01 Date 17-Sep-2026
2 17-Sep-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 24-Sep-2026

BOQ

Name of Work:-
Sl. No. Item Description
1Supply and Installation of 11 KV Compact Sub Station 250 KVA consisting of following items :-
2(A) HT SWITCHGEAR 11kV, 630Amps 21KA for 3 Sec. SF6 insulated Non-Extinsible Compact switchgear(Type CV) consisting ofOne No's fixed Manual load break switches(LBS) andone No. Fixed Manual Vacuum Circuit Breaker(VCB) having inbuilt load break switch and earth switch within SF6 insulated robotically welded non ferrite non magnetic stainless steel enclosure of thickness 2.0mm having IP 67, with series trip,self powered microprocessor based numerical 3 O/C & 1 E/F relay (IDMTL + Inst.) protection.Interconnection between HT switchgear and transformer shall be using 1Cx3x95 sq.mm Al. unarmorured XLPE Cable 1 No. Relay shall be self powered (50,50N,51,51N) with RS485 communication port 1 No. Protection CT shall be 40/1A 2.5VA 5P10. 1 Set. Standard Manometer (SF6 Gas Pressure Indicator) 1 No. Fault Passage Indicator(FPI) for incoming LBS only 1 No. Voltage presence indicator(VPIS) for incoming Healthy Indications 1 Set Manual push button for breaker ON/OFF 1 Set Mechanical Indication for Breaker & LBS ON/OFF/EARTHED. 3 No. Operating handle 1 No. All incoming modules of the RMU shall be capable for cable termination of 3C x 300 sq.mmAl XLPE Cable, incoming cable termination kits shall be in the scope of purchaser only.
3(B) Transformer 250 KVA 11kV/433V Dyn11 Copper Wound Cast Resin Dry Type (AN) distribution Transformer with Off Circuit Tap Links (Make: ABB Approved vendors) 1No. Off Circuit Tap Links (OCTL), Tapping range +7.5% to -7.5% in a steps of 2.5% (6 Steps/7 Positions) Insulation Class:C, Temp. Rise Shall be 90 Deg. C Over an ambient of 50 Deg.C Temp. Transformer Losses: As per IS 2026 & IS 11171 No Load Losses : As per Manufacturers Standards Load Losses at 75 Deg.C : As per Manufacturers Standards % Impedance (%Z) shall be 6.25% (Subject to IS Tol.) Rating & Diagram (R&D) Plate (Fitted on Transformer) 1 No. Surge Arrestor (Fitted on Transformer CCA on HV Side) 1 No. Digital Winding Temp. Indicator with Alarm and Trip Contacts (With RS-485 Port).
4(C) LT PANEL- 400A Aluminium Busbar (100% for Phase & 50% for Neutrals) Current density 1amp/sqmm, having IP2X, Fabrication using 1.5/2mm CRCA sheet steel complete with internal wiring consisting of following. INCOMER From transformer 400Amps 4P 50Hz 50KA Fixed Manual TypeMoulded Case Circuit Breaker (MCCB)with microprocessor based release for Overload (O/L), Short circuit (S/C) & Earth Fault (E/F) protection. 1 No. LED type Indicating Lamp - RYB, ON-OFF-TRIP. 1 Set. LT side metering CT 400A/ 5A, 5VA, Cl:1.0 1 Set Digital Multifunction Meter (MFM), CL-1.0 Accuracy with RS485 Port
5(D) OUTDOOR ENCLOSURE Outdoor type enclosure having construction of Galvanised Sheet Steel having 1.5mm thickness for Non-load bearing & 2.0 mm for Load bearing partition sheets & Door with HRCA 4 mm base frame. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP23 degree of protection for Transformer compartment. The enclosure exterior shall be Powder Coated (Colour Light gray and dark gray ). Each compartment will be provided with the door and pad locking arrangement. The Compartment illumination lamp with door operated switch shall be provided for MV & LV compartment. As per IEC 62271-202 Please Enable Macros to View BoQ information
6(D) OUTDOOR ENCLOSURE Outdoor type enclosure having construction of Galvanised Sheet Steel having 1.5mm thickness for Non-load bearing & 2.0 mm for Load bearing partition sheets & Door with HRCA 4 mm base frame. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP23 degree of protection for Transformer compartment. The enclosure exterior shall be Powder Coated (Colour Light gray and dark gray ). Each compartment will be provided with the door and pad locking arrangement. The Compartment illumination lamp with door operated switch shall be provided for MV & LV compartment. As per IEC 62271-202 Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57129249
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 53 Lakhs
LAST DATE 24-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Providing Of Compact Sub Stn (250 Kva Transformer) And Connected Items At Lower Dahung And 01 X 15 Kva Genr Set For Ee Mech Section Under Ge Tenga
Basic Detail
Tender No 8656/E8
Bidding Type Tender
Location
City siliguri
State West Bengal
Key Dates
Publish Date 17 Sep 2026
Submission Date 24 Sep 2026
Open Date 01 Oct 2026
Finance
Tender Value 53 Lakhs
Tender Fee 1000
EMD 1.04 Lakhs
Exemption Available
Document List
5e6f12f0-51ce-412b-9e1c-05bdd3fccc63.html
BOQ_880262.xls
TENDERDOCUMENT8656NEW.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 17, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Sep 24, 2026
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 4 days
Sep 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Oct 01, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
html

5e6f12f0-51ce-412b-9e1c-05bdd3fccc63.html

xls

BOQ_880262.xls

pdf

TENDERDOCUMENT8656NEW.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders