Tender For Renovation Of House No. 3020, Type- Vi Sector-19, Chandigarh. (01 No. House) (E.I Work) (Ibm No. W4/ 2026/ 26284).
Tender Value
1.84 Lakhs
Estimated cost
Bid Submission
26 Aug 2026
3 days left
EMD
3700
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Renovation Of House No. 3020, Type- Vi Sector-19, Chandigarh. (01 No. House) (E.I Work) (Ibm No. W4/ 2026/ 26284).
BOQ
| Sl. No. | Item Description |
| 1 | DSR Item No. 1.10Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 2 | Group B |
| 3 | DSR Item No. 1.15Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel /PVC conduit including dismantling as required. |
| 4 | Group B. |
| 5 | DSR Item No. 1.17Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 6 | 3 x 1.5 sq. mm |
| 7 | 3 x 2.5 sq. mm |
| 8 | DSR Item No.1.21Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 9 | DSR item No.1.24Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 10 | 5/6 amps switch |
| 11 | 2 way 5/6 A. switch |
| 12 | 15/16 amps switch |
| 13 | 3 Pin 5/6 A. socket outlet |
| 14 | 6 pin 15/16 amps socket |
| 15 | Bell push |
| 16 | DSR item No.1.25Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 17 | DSR item No.1.26Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 18 | DSR item No.1.27Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. |
| 19 | 1 or 2 Module (75 mmX75 mm) |
| 20 | 3 Module (100 mmX75 mm) |
| 21 | 4 Module (125 mmX75 mm) |
| 22 | 6 Module (200 mmX75 mm) |
| 23 | 8 Module (125 mmX125 mm) |
| 24 | 12 Module (200 mmX150 mm) |
| 25 | DSR item No.1.28Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. |
| 26 | 1 or 2 Module |
| 27 | 3 Module |
| 28 | 4 Module |
| 29 | 6 Module |
| 30 | 8 Module |
| 31 | DSR item No.1.31Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 32 | DSR item No.1.32Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 33 | DSR Item No. 1.33Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 34 | DSR item No.1.57 Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 35 | DSR ITEM NO. 9.2Brush Less Direct Current (BLDC) MotorSupply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, (As per Complete Item No. 14 of the DNIT). |
| 36 | 1400mm, service value ≥ 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum) |
| 37 | Supply & erection of fresh air fan high speed motor with copper wound 10” sweep with louver and plastic body complete with high speed motor, blades, epoxy powder coated of Havells make Ventiliar DX White / Orient make Ventilator / Crompton make Brisk Air/ Bajaj make 70049 250mm sweep only. (As per Complete Item No. 15 of the DNIT). |
| 38 | Supply & erection of Exhaust Fan (heavy duty motor with copper wound metallic body) following size complete with motor, metallic blades, double ball bearing with minimum power consumption, (As per Complete Item No. 16 of the DNIT). |
| 39 | Size 12” Sweep 900 RPM with louver of Havells make Turbo Force SP / Orient make Industrial Heavy Duty / Crompton make EXHD 300-6-1/ Bajaj make Supreme PLUS/ Usha make Turbo HDEF only. |
| 40 | S/E of LED Bulk Head Luminaries weather proof frosted light with PMMA / PC reflector and silicon gasket to be installed on surface. The LED fitting should have minimum system Lumen output minimum 1000 Lumen and the driver of the fitting should be workable on 140-260 Volt. (As per Complete Item No. 17 of the DNIT). |
| 41 | DSR ITEM NO. LED 8.9.5Batten light (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, (As per Complete Item No. 18 of the DNIT). |
| 42 | 18-22 watt |
| 43 | DSR Item No. 8.16.3LED Flood Light, powder coated pressure die cast aluminum (System lumen efficacy ≥120 and <135 lm/Watt)Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, (As per Complete Item No. 19 of the DNIT). |
| 44 | 100 Watt Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 26, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysAug 26, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender