Tender For Repair/ Maint/ Renewal Of Perimeter Lights, Street Light, Security Lights, Post Top Lanterns, Garden Lights, Gate Lights Including Control Panels, Illumination Sys, Dg Set, Laundary Plant And Misc Installations, External Fire Fightning Sys
Tender Overview
Project Description
Tender for Repair/ Maint/ Renewal Of Perimeter Lights, Street Light, Security Lights, Post Top Lanterns, Garden Lights, Gate Lights Including Control Panels, Illumination Sys, Dg Set, Laundary Plant And Misc Installations, External Fire Fightning Sys, Incl Attending Breakdown And Day To Day Complaints At Dhangu Complex Under Ge South Pathankot
BOQ
| Sl. No. | Item Description |
| 1 | Material and labour for repair/maintenance of hydraulic front/extractor top loading upto 50 kgs capacity including taking out of internal drum, soldering, refix and balancing of internal drum and replacement of base bearing, glands, gland cup, studs and top shut off handle of any type etc as per sample all as specified and directed. Note: Extra spares required other than specified in job shall be measured and paid separately under items of this schedule. |
| 2 | Material and labour for repair/maintenance of slucing machine front/top loading upto 50 kgs capacity including taking out of internal drum, soldering, refix and balancing of internal drum and replacement of bearing, gland, gland cup and studs of any type etc as per sample all as specified and directed. Note: Extra spares required other than specified in job shall be measured and paid separately under items of this schedule. |
| 3 | Material and labour for repair/maintenance of washing machine front/top loading upto 100 kgs capacity including taking out of internal drum, soldering , refix and balancing of internal drum and replacement of bearing, gland, gland cup and studs of any type etc as per sample all as specified and directed. Note: Extra spares required other than specified in job shall be measured and paid separately under items of this schedule. |
| 4 | Material and labour for repair/maintenance of dry tumbler machine front/top loading upto 50kgs capacity including taking out of internal drum, soldering , refix and balancing of internal drum and replacement of bearing, gland, gland cup, studs and wire mesh in bottom of machine any type etc as per sample all as specified and directed.Note: Extra spares required other than specified in job shall be measured and paid separately under items of this schedule. |
| 5 | Material and labour for replacement of existing u/s limit switch 10 Amps, 1 NO + 1 NC, 500 volts as per sample complete all as specified and directed. |
| 6 | Material and labour for replacement of existing u/s forward/ reverse mechanism of washing machine as per sample complete all as specified and directed. |
| 7 | Material and labour for replacement of existing u/s ML contactor ML 1.5, 415 volts, 3 phase as per sample complete all as specified and directed. |
| 8 | Material and labour for replacement of existing u/s ON/ OFF push button, AC 15: 415 V, 4 Amps, DC 13: 110 Volts, DC 0.5 Amps as per sample all as specified and directed. |
| 9 | Material and labour for replacement of existing u/s Magnetic coil drain switch Type:- SLD, 415 volts, 50 Hz, Max. stroke:- 3.14 MM, Pull:- 6.75 Kg as per sample. |
| 10 | Material and labour for replacement of existing u/s Electronic timer type ETR D2, 240 volts as per sample. |
| 11 | Material and labour for replacement of existing u/s Indicators 2XVLIR, 130 Volts, 2.6 W as per sample. |
| 12 | Material and labour for replacement of existing u/s ML 2 Contactor, 415 volts, 32 Amps as per sample all as specified and directed. |
| 13 | Material and labour for replacement of existing u/s Electrode suitable for RXA-06 (2000). |
| 14 | Material and labour for replacement of existing u/s Economiser suitable for RXA-06 (2000). |
| 15 | Material and labour for replacement of existing u/s ignition transformer 14 KVA, 440 volts/11 KV. |
| 16 | Material and labour for replacement of existing u/s Photocell 8205. |
| 17 | Material and labour for replacement of existing u/s sequence controller MA 810. |
| 18 | Material and labour for replacement of existing u/s gland washer for triplex pump make as per sample |
| 19 | Material and labour for replacement of existing u/s valve sheet assembly make as per sample |
| 20 | Material and labour for replacement of existing u/s triplex pump piston (SP) make as per sample |
| 21 | Material and labour for replacement of existing u/s sight glass size 50 mm dia and 4 mm thick fire proof make as per sample |
| 22 | Material and labour for replacement of existing u/s Thermometer 0 to 150 degree centigrade make as per sample |
| 23 | Material and labour for replacement of existing u/s pressure gauge 0 to 25 Kg/cm, 4 inch dia including back connection make as per sample |
| 24 | Material and labour for replacement of existing u/s DTC (Digital temperature controller) controller make as per sample |
| 25 | Material and labour for replacement of existing u/s limit switch suitable for RXA-6 (2000) make as per sample |
| 26 | Material and labour for replacement of existing u/s Nozzle 6.5 suitable for RXA-6 (2000) make as per sample |
| 27 | Material and labour for replacement of existing u/s burner rod assy. |
| 28 | Material and labour for replacement of existing u/s steam blow down valve size 20 mm make as per sample |
| 29 | Material and labour for replacement of existing u/s steam non return valve size 20 mm make as per sample |
| 30 | Material and labour for replacement of existing u/s metallic brid hose pipe size 3/8 x 36 inch make as per sample |
| 31 | Material and labour for replacement of existing u/s metallic brid hose pipe size 1/2 x 20 inch make as per sample |
| 32 | Material and labour for replacement of existing u/s water level pressure switch make as per sample |
| 33 | Material and labour for replacement of existing u/s steam pressure switch make as per sample |
| 34 | Material and labour for replacement of existing u/s safety valve 25 mm make as per sample |
| 35 | Material and labour for replacement of existing u/s electrode cap for burner make as per sample |
| 36 | Material and labour for replacement of existing u/s RTD assy make as per sample. |
| 37 | Material and labour for replacement of existing u/s super heater as per sample all as specified and directed. |
| 38 | Material and labour for replacement of existing u/s asbestos teflon rope size 10 mm or required and directed. |
| 39 | Material and labour for replacement of existing u/s asbestos teflon rope size 5 mm or required and directed. |
| 40 | Material and labour for replacement of existing u/s white cement complete all as specified and directed. |
| 41 | Material and labour for replacement of existing u/s door gasket of washing machines of size and capacities 25/50/100/200 Kgs, drying tumbler 25/50 kgs as per sample all as specified and directed. |
| 42 | Material and labour for replacement of existing u/s spring for hydraulic extractor 25 kgs capacity as per sample all as specified and directed. |
| 43 | Material and labour for replacement of existing u/s spring for hydraulic extractor 50 kgs capacity as per sample all as specified and directed. |
| 44 | Material and labour for replacement of existing u/s bronze steam valve 15 mm, ISI marked as per sample. |
| 45 | Material and labour for replacement of existing u/s bronze steam valve 20 mm, ISI marked as per sample. |
| 46 | Material and labour for replacement of existing u/s bronze steam valve 25 mm, ISI marked as per sample. |
| 47 | Material and labour for replacement of existing u/s bronze steam valve 40 mm ISI marked as per sample. |
| 48 | Material and labour for replacement of existing u/s bronze steam valve 50 mm ISI marked as per sample. |
| 49 | Material and labour for ball valve 50 mm dia gun metal as per sample. Complete all as specified and directed. |
| 50 | Material and labour for replacement of existing u/s V- Belts Suitable for existing sluicing machine as per sample complete all as specified and directed. |
| 51 | Material and labour for replacement of existing u/s V- Belts Suitable for existing Washing machine as per sample complete all as specified and directed. |
| 52 | Material and labour for replacement of existing u/s V- Belts Suitable for existing Dry Tumbler as per sample complete all as specified and directed. |
| 53 | Material and labour for replacement of existing u/s V- Belts Suitable for existing Hydro Extractor as per sample complete all as specified and directed. |
| 54 | Material and labour for replacement of existing u/s V- Belts Suitable for existing Air compressor as per sample complete all as specified and directed. |
| 55 | Material and labour for replacement of existing u/s V- Belts Suitable for existing AHU as per sample complete all as specified and directed. |
| 56 | Material and labour for rewinding of existing unsv 3 Phase,415 volts, 50 Hz,induction motor of capacity upto 5 HP any make with super enameled copper winding wire of gauge as per existing including cutting and getting out old US winding, sleeve work, varnishing with E class insulation varnish , threading and making all electric connections including taking out and refixing at site all as specified and directed. |
| 57 | Material and labour for replacement of existing un-serviceable/ perished metallic wheels with outer cover of cloth trollies including welding/ fabrication and testing on load complete all as specified and directed. |
| 58 | M & L for welding / fabrication to the existing u/s equipment of the machinery for re-strengthing to the existing assests including replacement of angle iron any size, channel, flat iron, MS sheet, nut, bolt and washers etc complete all as specified and directed. |
| 59 | Supply and laying of DWC (Double wall corrugated) pipe of 40 mm bore outer dia laid for protection of cables in trenches, floors complete all as specified and directed. |
| 60 | Supply and laying of DWC (Double wall corrugated) pipe of 50 mm bore outer dia laid for protection of cables in trenches, floors complete all as specified and directed. |
| 61 | Supply and laying of DWC (Double wall corrugated) pipe of 80 mm bore outer dia laid for protection of cables in trenches, floors complete all as specified and directed. |
| 62 | M&L in replacement of Sub main wiring in two single run FRLS PVC insulated cable 4 Sqmm (Nominal dia) copper conductor (multistrand) and drawing in and including new PVC concealed non metallic conduit pipe ISI marked including one run 4 Sqmm multistranded copper conductor FRLS PVC green colour insulated unsheathed cable for earth continuity complete all as spd and directed. |
| 63 | M&L in replacement of Sub main wiring in two single run FRLS PVC insulated cable 6 Sqmm (Nominal dia) copper conductor (multistrand) and drawing in and including new PVC concealed non metallic conduit pipe ISI marked including one run 6 Sqmm multistranded copper conductor FRLS PVC green colour insulated unsheathed cable for earth continuity complete all as spd and directed. |
| 64 | M&L for replacement of existing unserviceable earthing complete with galvanized steel earth plate electrode of size 600x600x6 mm thick as earth electrode with top edge of the earth plate not less than 1.5mtr below ground level using galvanized iron strip 32x6mm earthing lead as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of charcoal dust and salt all around the earth plate, earth work in any type of soil remain surplus excavated material all as required at site and specified in EP No 3 of SSR complete all as specified and directed by Engineer-in-charge incl testing on completion. |
| 65 | Testing of dielectric strength of transformer oil for indoor type Stabilizer of capacity 30 kva to 500 kva,433 V, filtration of transformer oil by passing through filtration plant to remove moisture, impurities and improving di-electric strength to above 40 KV for 1 minute including new transformer oil for toping up & testing after filtration complete as specified.(Note: Transformer oil will be measured & paid separately.) |
| 66 | Supply and fix in replacement of servo stabilizer Digital display card suitable for three phase stabilizer 30 KVA to 50 KVA as per existing all as specified and directed |
| 67 | Supply and fix in replacement of servo stabilizer Digital display card suitable for three phase stabilizer 100 KVA as per existing all as specified and directed |
| 68 | Supply and fix in replacement of servo stabilizer Digital display card suitable for three phase stabilizer 500 KVA as per existing all as specified and directed |
| 69 | Supply and fix in replacement of servo stabilizer multi functional meter suitable for three phase stabilizer 30 KVA to 50 KVA as per existing all as specified and directed |
| 70 | Supply and fix in replacement of servo stabilizer multi functional meter suitable for three phase stabilizer 100 KVA as per existing all as specified and directed |
| 71 | Supply and fix in replacement of servo stabilizer multi functional meter suitable for three phase stabilizer 500 KVA as per existing all as specified and directed |
| 72 | Supply and fix in replacement of servo stabilizer motor upto 10 KG with RC suitable for three phase stabilizer 30 KVA to 100 KVA as per existing all as specified and directed |
| 73 | Supply and fix in replacement of servo stabilizer motor 15 kg to 20 KG with RC suitable for three phase stabilizer 500 KVA as per existing all as specified and directed |
| 74 | Supply and fix in replacement of servo stabilizer Dimmer as per existing for three phase stabilizer 30 KVA to 50 KVA as per existing all as specified and directed |
| 75 | Supply and fix in replacement of servo stabilizer Dimmer as per existing for three phase stabilizer 100 KVA to 200 KVA as per existing all as specified and directed |
| 76 | Supply and fix in replacement of servo stabilizer Dimmer as per existing for three phase stabilizer 250 KVA to 500 KVA as per existing all as specified and directed |
| 77 | M&L for dismantling unserviceable transformer for servo stabilizer 50 KVA incl repair/replacement of defective parts and rewinding transformer, refixing same after repair testing and commissioning complete all as specified and as directed. |
| 78 | M&L for dismantling unserviceable transformer for servo stabilizer 100 to 200 KVA incl repair/replacement of defective parts and rewinding transformer, refixing same after repair testing and commissioning complete all as specified and as directed. |
| 79 | Supply and fix in replacement of servo stabilizer 50 KVA rectifier and capacitor complete all as specified and as directed. |
| 80 | Supply and fix in replacement of servo stabilizer 100 to 200 KVA rectifier and capacitor complete all as specified and as directed. |
| 81 | Supply and fix in replacement of servo stabilizer 50 KVA carbon push complete all as specified and as directed. |
| 82 | Supply and fix in replacement of servo stabilizer 100 to 200 KVA carbon push complete all as specified and as directed. |
| 83 | Supply and toping of transformer oil with 40KV di-electric strength Transformer and Servo voltage stabilizer .Oil shall conform to IS 335 of 1993 complete all as specified and directed. |
| 84 | Supply and fix in replacement of MCB SP 6-32 Amps, 10 KA breaking capacity , 230 V, 50 Hz AC Supply complete all as specified and directed by Engineer - in - Charge. |
| 85 | Supply and fix in replacement of MCB SPN 6-32 Amps, 10 KA breaking capacity 230 V, 50 Hz AC Supply complete all as specified and directed by Engineer - in - Charge. |
| 86 | Supply and fix in replacement of MCB SPN 40 Amps, 10 KA breaking capacity 230 V, 50 Hz AC Supply complete all as specified and directed by Engineer - in - Charge. |
| 87 | Supply and fix in replacement of MCB TPN 40 Amps, 10 KA breaking capacity 230 V, 50 Hz AC Supply complete all as specified and directed by Engineer - in - Charge. |
| 88 | Supply and fix in replacement of MCB TPN 63 Amps, 10 KA breaking capacity 230 V, 50 Hz AC Supply complete all as specified and directed by Engineer - in - Charge |
| 89 | Taking down defective street light fitting of any size/ type/ capacity from height of pole/walls/high mast of any location exceeding 7.0 m height for repair work and re-fixing back after repair work including checking, inspecting, testing and commissioning complete all as directed by Engr-in-Charge.Note: a) The M/L for Items like lamp, electronic drivers, surge protection devices etc shall be measured and paid separately under relevant items here in under this Schedule. b) Necessary tools like ladders & other T&P required etc shall be arranged by the Contractor. c) The rate quoted deemed to be inclusive for minor parts nut bolts, circle clips, clamps etc if any required at site.d) The M/L for repairs to LED panel is not included in the scope and shall be measured and paid separately. |
| 90 | supply and fix in repair Electronic digital Timer (Astronomical) suitable for street light timer DB panels . |
| 91 | Supply only the following spares suitable for LED street/Flood light fittings :- |
| 92 | Electronic driver potted type IP-65, suitable for 120 to 200 W LED light fitting |
| 93 | Electronic driver potted type IP-65, suitable for 90 to 100 W LED light fitting |
| 94 | Electronic driver potted type IP-65, suitable for 30 to 70 W LED light fitting |
| 95 | Surge protection device of capacity 10 KV suitable for LED light fitting |
| 96 | Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete and suitable for fixing at 40 mm dia street light bracket, all as specified and directed. |
| 97 | Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete and suitable for fixing at 40 mm dia street light bracket, all as specified and directed. |
| 98 | Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete and suitable for fixing at 40 mm dia street light bracket, all as specified and directed. |
| 99 | Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply and fixing LED street light fitting 100 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete and suitable for fixing at 40 mm dia street light bracket, all as specified and directed. |
| 100 | Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp. |
| 101 | Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp |
| 102 | Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp |
| 103 | Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply and fixing LED flood light 170 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp |
| 104 | Supply & fix in replacement of decorative path way light lighting LED decorative post top lantern for 360 degree 40 watts 230 volts, 50 HZ, maple shaped in soothing opal/ prismatic finish made up of polycarbonate, including all accessories prewired complete all as specified and directed. |
| 105 | Supply and erecting in true vertical or to be planed as strut, steel tubular swaged welded pole complete with MS base plate final taper plug, bolt, nuts & screw, 6mm thick of size 300mmx300mm welded at the centre of the pole, type 410 SP-31(09 Mtr long) including drilling of holes of required size and nuts for fixing of cross arms, painting with coat of red oxide zinc chrome primer and two coats of aluminum paint on exposed surfaces and two coats of black bituminous paint for portion embedded in concrete, painting three black and three white bands at lower portion of pole each of 300mm height at 300mm spacing complete all as specified incl dismantling old one complete all as directed and specified. NOTE :- Earth work, Cement concrete in foundation, coping etc. will be measured and paid separately under relevant item. |
| 106 | S&F in repair PVC insulated 3 core 2.5 Sq mm stranded Copper conductor cable for connecting OH line/junction box to street light fitting testing and commissioning complete all as specified and directed. |
| 107 | S&F in repair PVC insulated 3 core 1.5 Sq mm stranded Copper conductor cable for connecting OH line/junction box to street light fitting testing and commissioning complete all as specified and directed. |
| 108 | M&L for PCC 1:4:8 type D2 with 40 mm graded aggregate as in foundations, filling and mass concrete complete all as specified and directed. |
| 109 | M&L for PCC 1:3:6 type C1 with 20 mm graded aggregate for foundation of poles and stay including form work complete all as specified and directed. |
| 110 | Supply and fixing timelite distribution boards (street light DBs) 40 A 3 pole with 230 V Astronomical time switch complete all as directed including dismantling old one . |
| 111 | S&F loop-in/loop-out box of outer size 250x210x115 mm made out of FRP(Hot moulded type) with weather proof canopy and locking screws along with 5/6 Amps MCB - 01 No, 50 Amps rated 3 pole connector- 01 Nos, neutral link mounted and Din rail suitable size for mounting MCB/Connector etc complete in the box, duly fixed to steel tubular/rail/PCC/RCC pole using 25 x 3mm FI clamp, including suitable gland and lugs for connecting cable complete all as directed including dismantling old one. |
| 112 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtrs in depth for laying of cables, pipes etc and getting out in any type of soil complete all as specified and directed. |
| 113 | Excavation in trenches not exceeding 1.5 mtr wide and exceeding 1.5 mtrs in depth but not exceeding 3.00 Mtr in depth for foundations, laying of cables, pipes etc and getting out in any type of soil complete all as specified and directed. |
| 114 | Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 115 | Returning, filling in, including spreading, leveling watering and well ramming in layers not exceeding 25cm thick complete all as directed. |
| 116 | M & L for good quality dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified in clause 19.75 of MES Schedule part-I (2009) Note : Sand shall be fined sand as specified and punned thickness shall be measured and paid. |
| 117 | Supply and laying sub class 'B' bricks of old size (230x115x75 mm) or of size locally available , laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge |
| 118 | Removing existing 1100 volts grade, XLPE/PVC, armoured, electric power cables (heavy duty) with aluminium conductor of sizes 25 Sqmm 3.5/4 core to 300 Sqmm 3.5 core from trench/ duct/ pipe carefully for identifying the defects and relaying the same after rectification of defects complete all as directed. Note: Earth work ( Excavation, Returning & refilling and removal), sand cushioning , cable protection cover, GI protection pipe shall be measured and paid for separately under respective item of Schedule |
| 119 | Removing existing 1100 volts grade, XLPE/PVC, armoured, electric power cables (heavy duty) with aluminium conductor of sizes 6 Sqmm 4 core to 16 Sqmm 4 core from trench/ duct/ pipe carefully for identifying the defects and relaying the same after rectification of defects complete all as directed. Note: Earth work ( Excavation, Returning & refilling and removal), sand cushioning , cable protection cover, GI protection pipe shall be measured and paid for separately under respective item of Schedule |
| 120 | Supply and lay in replacement of cable XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of cross sectional area 16 Sq mm 4 core. Note: Earth work (Excavation, Returning & refilling and removal), sand cushioning , cable protection cover, GI protection pipe shall be measured and paid for separately under respective item of Schedule |
| 121 | All as per serial item No. 116 above but of size 10 Sqmm 4 core |
| 122 | All as per serial item No. 116 above but of size 25 Sqmm 4 core |
| 123 | All as per serial item No. 116 above but of size 35 Sqmm 3.5 core |
| 124 | All as per serial item No. 116 above but of size 50 Sqmm 3.5 core |
| 125 | All as per serial item No. 116 above but of size 70 Sqmm 3.5 core |
| 126 | All as per serial item No. 116 above but of size 95 Sqmm 3.5 core |
| 127 | All as per serial item No. 116 above but of size 120 Sqmm 3.5 core |
| 128 | All as per serial item No. 116 above but of size 185 Sqmm 3.5 core |
| 129 | All as per serial item No. 116 above but of size 240 Sqmm 3.5 core |
| 130 | Supply and laying in replacement of GI Pipe light grade 40mm dia with all fittings laid/fixed on wall/pole or under road/PCC crossing and all as specified and directed. |
| 131 | Supply and laying in replacement of GI Pipe light grade 80mm dia with all fittings laid/fixed on wall/pole or under road/PCC crossing and all as specified and directed. |
| 132 | Material and Labour for Horizontal Boring/ Cutting of Road/ Foot Path for using through 40/80mm bore pipe for cable protection and finishing PCC after Boring/ Cutting of road/ Foot path, complete all as specified and as directed. |
| 133 | Supply and fix in replacement weather proof flat twin core 6 sqmm multistrand aluminium conductor cable complete all as specified and directed by Engineer-in-Charge. |
| 134 | Supply and fix in replacement weather proof flat twin core 10 sqmm multistrand aluminium conductor cable complete all as specified and directed by Engineer-in-Charge. |
| 135 | Supply and Fixing of Cable jointing kit for 1100 V (Earthed) grade cable for Stright through joint heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 25 sqmm to 50 sqmm complete all as specified and directed Engr-in-Charge. |
| 136 | Supply and Fixing of Cable jointing kit for 1100 V (Earthed) grade cable for Stright through joint heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 10 sqmm to 16 sqmm complete all as specified and directed Engr-in-Charge. |
| 137 | Supply and Fixing of Cable jointing kit for 1100 V (Earthed) grade cable for INDOOR / OUTDOOR END TERMINATIONS heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 16 sqmm to 50 sqmm complete all as specified and directed Engr-in-Charge. |
| 138 | Supply and fix in replacement of Lugs aluminium suitable for cable size of 16 to 95 sqmm complete all as specified and directed Engineer-in-Charge. |
| 139 | Supply and fix in replacement of industrial change over switch gear 100 Amp 415 V Four Pole Off Load Side Handle Operated In Sheet enclosure, Powder Coated, Weather proof conforming to IS: 13947 by connecting the electrical connection and fixing on wall or panel with clamp nut, bolt etc complete all as specified and as directed by Engr-in-Charge. |
| 140 | Supply and fix in replacement of 630 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 36 KA with adjustable thermal and magnetic tripping system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board for replace of unserviceable MCCB complete all as specified and directed. |
| 141 | Supply and fix in replacement of 63 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 10 KA with adjustable thermal and fixed magnetic setting system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board for replace of unserviceable MCCB complete all as specified and directed. |
| 142 | Supply and fix in replacement of 100 AMP, MCCB 4 pole 415 volt, AC 50 Hz,10 KA with adjustable thermal and fixed magnetic setting system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board for replace of unserviceable MCCB complete all as specified and directed. |
| 143 | Supply and fix in replacement of 125 AMP, MCCB 4 pole 415 volt, AC 50 Hz, 10 KA with adjustable thermal and fixed magnetic setting system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board for replace of unserviceable MCCB complete all as specified and directed. |
| 144 | Supply and fix in replacement 400 AMP contactor three pole 415 volt, AC 50 Hz, suitable of Existing panel board for replace of unserviceable contactor complete all as specified and directed. |
| 145 | Supply and fix in replacement 200 Amp, contactor three pole 415 volt, AC 50 Hz, suitable of Existing panel board for replace of unserviceable contactor complete all as specified and directed. |
| 146 | Supply and fix in replacement of HRC fuse 630 Amp 415 suitable of Existing panel board for replace of unserviceable HRC fuse complete all as specified and directed. |
| 147 | Material and labour for painting to steel tubular 9.00/11.0 metre long with one coat of red oxide on pole and two coats of aluminium paint complete all as specified and directed by Engineer-in-Charge |
| 148 | Material and labour for painting to electric pole PCC/steel tubular 9.00/11.0 metre long with two coats of synthetic enamel paint up to 1.20 metre height from ground level in 30 cm alternative black and yellow strips and numbering of pole with white in colour complete all as specified and directed by Engineer-in-Charge. |
| 149 | S&F GI pipe Bracket made out of 40mm dia light grade pipe bend to shape of approx length 1.5mtr including 2 nos Ms clamp of flat iron of size 40x6mm complete with nut bolt washers for fixing street light fitting including taking down old bracket complete all as directed by Engineer-in -Charge |
| 150 | Supply and fix in replacement of decorative gate light moon (opal) type made up of high grade unbreakable polycarbonate material suitable for retrofit B22 base and fixing on existing 40/50 mm pole dia with 7 watt LED lamp complete all as specified and directed by Engineer-in-Charge |
| 151 | Supply and fix of decorative gate light MUSHROOM (PRISMATIC) type made up of high grade unbreakable polycarbonate material suitable for retrofit B22 base and fixing on existing 40/50 mm pole dia with 7 watt LED lamp complete all as specified and directed by Engineer-in-Charge |
| 152 | Supply and fix in replacement of decorative gate light Lexo (Prismatic) made up of high grade unbreakable polycarbonate material suitable B22 Base and upto 60 mm pole dia with 10 watt LED lamp complete all as specified and directed by Engineer-in-Charge |
| 153 | Supply and fix in replacement of new generation post top energy saving environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LED as light sourse Coral (opal) - IP65 suitable for pole dia 76 mm with 25 watt LED lamp complete all as specified and directed by Engineer - in - Charge. |
| 154 | Supply and fix in replacement of Building street light fitting Endura pearl 25W LED lamp new generation energy saving & environmental friendly long life made up of pressure die-cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP opening separate driver compartment with IP65 protection and impact resistance of IK07,with suitable of GI pipe (light grade) bracket and clamps,nut bolts are fixed on wall/post and all as required and directed |
| 155 | Cleaning/desludging of raw sewage in under ground collection sump well up to the depth 7 mtr installation by closing main incoming manhole and pumping out raw sewage to neat drain by using portable non clog pump set, cleaning of raw sewage sump by manually or mechanically using (spl T&P such as movable sewage cleaning tanker) scrapping inside wall and bottom by steel wire bush to remove raw material and transport it to outside cantonment area for disposal at low lying area up to the distance of 10 Kms at his own arrangement where the sanitary hazard do not take place and as per guidelines of civil authority all as directed for disposal. Thereafter cleaning/washing of interior surface of UG sump using high grade bleaching powder and lime mixed water incl painting with two coat of cement based paint. |
| 156 | S & F in repair 3 pole power contactor with coil voltage 230 volt AC of current carring capacity 32 to 40 Amps complete including control wiring thimbles etc complete all as directed. |
| 157 | S & F in repair 3 pole power contactor with coil voltage 230 volt AC of current carring capacity 40 to 100 Amps complete including control wiring thimbles etc complete all as directed. |
| 158 | Dismantling old feeder pillar box & Supply installing, testing and commissioning of LT feeder pillar box factory made Outdoor type, fabricated out of 3.15 mm thick CRCA sheet with angle iron base frame made of 65 x65 x 6mm, 45 cm height, dust and vermine proof, suitable for voltage 415 separate hinge door for each compartment for incoming and outgoing MCCB etc with locking arrangement, with back door openable screwed, legs grouted in PCC including painting with two coats of epoxy powder paint over a coat ofd primer after alkaline degreasing, descaling in dilute sulphuric acid or any other acid and phosphate and with aluminium busbar (TPN) and including provn of following :- i) Aluminium Bus bar 600-A- mounted on porcelain insulator - 01 Set ( Set of 4 Nos) with PVC sleeve insulation ii) MCCB 4 Pole ,400 Amp, 415 V, 36 KA (Thermal magnetic release)- 01 Nos (incommer) iii) MCCB 4 Pole , 250 Amp, 415 V, 36 KA (Thermal magnetic release)- 02 Nos (outgoing) iv) MCCB 4 Pole , 160 Amp, 415 V, 25 KA (Thermal magnetic release) - 03 Nos (02 OG + 01 SB)v) MCCB 4 Pole , 63 Amp, 415 V, 25 KA (Thermal magnetic release) - 01 Nos (Outgoing)vi) Digital Voltmeter of size 96x96mm rating 0-500 volts with selector switch - 01 Nos vii) Digital Amp meter of size 96x96mm rating 0-1000 Amp with CT's & selection switch - 01 Nos viii) RYB LED indicator- one setNote :- (a) The panel shall be as per CPRI certificate. (b) Rates inclusive of PCC complete |
| 159 | Dismantling old feeder pillar box & Supply, installing, testing and commissioning of LT feeder pillar box factory made cubicle outdoor type, fabricated out of 3.15 mm thick CRCA sheet and size of LT feeder pillar is not less than 900mmx600mmx300mm floor mounted with angle iron base frame made of 50 x 50 x 6mm , 50 cm height, floor mounted duly bolts and nuts grouted, dust and vermine proof, suitable for voltage 415 V 3 Phase 4 wire, Square aluminium bus bar Chamber 320 Amp Capacity weather proof, with IP-54 protection, with separate hinge door for each compartment for incoming and outgoing MCCB etc with locking arrangement, with back door openable (Screwed), legs grouted in PCC complete including painting with two coats of epoxy powder paint over a coat of primer complete including supply fixing and making provision of the following :- (a) MCCB 4 pole 415 volts 3 phase 200 Amp 25 KA -01 No (b) LED Indicator RYB -01 Set ( Set of three). Note: The panel shall be as per CPRI certificate. Please Enable Macros to View BoQ information |
| 160 | Dismantling old feeder pillar box & Supply, installing, testing and commissioning of LT feeder pillar box factory made cubicle outdoor type, fabricated out of 3.15 mm thick CRCA sheet and size of LT feeder pillar is not less than 900mmx600mmx300mm floor mounted with angle iron base frame made of 50 x 50 x 6mm , 50 cm height, floor mounted duly bolts and nuts grouted, dust and vermine proof, suitable for voltage 415 V 3 Phase 4 wire, Square aluminium bus bar Chamber 320 Amp Capacity weather proof, with IP-54 protection, with separate hinge door for each compartment for incoming and outgoing MCCB etc with locking arrangement, with back door openable (Screwed), legs grouted in PCC complete including painting with two coats of epoxy powder paint over a coat of primer complete including supply fixing and making provision of the following :- (a) MCCB 4 pole 415 volts 3 phase 200 Amp 25 KA -01 No (b) LED Indicator RYB -01 Set ( Set of three). Note: The panel shall be as per CPRI certificate. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender