Public Administrative Department Local Bodies Closing in 4 days TDR #57124568

Tender For Special Repair / Renovation Of Fire Station Building & Residential Quarters In Sector 38-C, Chandigarh (Composite Work)

Issued by Local Bodies · Chandigarh, Chandigarh
Tender Value
61.79 Lakhs
Estimated cost
Bid Submission
28 Aug 2026
4 days left
EMD
1.23 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Special Repair / Renovation Of Fire Station Building & Residential Quarters In Sector 38-C, Chandigarh (Composite Work)

BOQ

Name of Work:- Special repair / Renovation of Fire Station Building & Residential Quarters in Sector 38-C, Chandigarh (Composite work)
Sl. No. Item Description
1Removing dry or oil bound distemper,water proofing cement paint and the like by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.DSR 14.46
2Dismantling old plaster or skirting raking out joints. (DSR 15.56)
3Providing and laying 15mm cement plaster of mix. Complete in all respect to the entire satisfaction of the Engineer-In-Charge. 1:4 (:1 cement : 4 Course Sand) (DSR 13.5.1)
4Providing and applying JK/Birla putty of 1mm thickness over plastered surface to prepare the surface even and smooth complete.
5Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : Old work (one or more coats) (DSR 14.45.1:)
6Finishing walls with Acrylic smooth exterior paint : Old work (one or more coats) applied @ 0.90 Ltr./10 Sqm). (DSR 14.66.2)
7Finishing walls with Acrylic Smooth exterior paint : New work (Two more coat ) complete in all respect and to the entire satisfaction of the Engineer-in-charge.
8Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead: Of area 3 sq. metres and below (DSR 15.12.1)
9Providing and fixing pressed steel door frames confirming to IS: 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb,lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of I.25tnm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick’with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre- treatment of the surface as directed by Engineer-in-charge: Profile E DSR 10.14.3 .1
10Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked black enamelled M.S butt hinges with necessary screws excluding panelling which will be paid for separately. Kiln seasoned selected planks of sheesham wood 35 mm thick shutters DSR 9.5.3.1
11Providing and fixing 12mm thick commercial ply ISI Marked fixed on existing wooden frame including beading and fitting complete in all respect to the entire satisfaction of Engineer-In-Charge.
12Providing and fixing glazed shutters for doors, windows and clerestory windows using 4.00 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.Kiln seasoned and chemically treated hard wood 35 mm thick .( N.S)
13Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : with ISI marked M.S. pressed butt hinges bright finished of required size 35 mm thick shutters (DSR 9.27.1.1)
14Renewing glass panes, with wooden fillets wherever necessary:- Float glass panes of thickness 4.00 mm. (DSR 14.5.1)
15P/F factory made PVC door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners & joined with 2 No of 150mm long brackets of 15x15mm MS square tube vertical door frame profiles to be reinforced with 19x19mm MS square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out frame. The door frame to be fixed to the wall using MS screws of 65/100 mm size, complete as per direction of EIC. (DSR No. 9.119)
1635 mm thick factory made panel PVC door shutter consisting of frame made out of single piece extruded solid PVCprofile. 5mm (+- 0.2mm) thick and s styles and 5 mm thick, 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing. (As per DSR I. No. 9.142)
17Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on New work. (DSR 13.61.1)
18Dismantling tile work in Walls Fixed with cement mortar including Disposal of material within 50 metres lead complete in all respects to the entire satisfaction of Engineer-In-Charge (N.S)
19Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4(1 cement: 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete. (DSR 11.41.2)
20Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. DSR 11.36
21Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red, Brown laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigment etc., complete. (DSR 11.37)
22Providing and fixing cup board shutters with 25mm thick veneered particle board IS : 3097 marked exterior grade (Grade I) of approved make including Ilnd class teak wood lipping of 25mm wide x 12 mm thick with necessary screws and bright finished stainless steel piano hinges complete as per direction of Engineer-in- Charge. DSR 9.130
23Providing and fixing kitchen cabinet below working shelves as per detail consists of chowkhet frame of hollock wood 2\\" x2\\" section with suitable rebate of 1\\" x ½\\" on outer side for shutter. The shutter are to be provided with 19mm thick MDF board with lipping all around and fixed with chowkhet frame with alpha type piano hinges and screwa etc. and provide with fancy teak wood handle and magnetic catcher. The inside surface to be painted with two coat of special quality synthetic enamal paint after primer coat and preparation of surfae. The complete frame to be fixed with iron hold fast ,corners, straps etc. complete in all respect to the entire satisfaction of the E.I.C. Note: - The measurement to be paid only front side, no extra measurement to be paid other sides.
24Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement: 3 fine sand) as per standard design (DSR 12.21.1)
25Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx 1mx 400 micron, finished with 12mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement rounding the edge and making and finishing the outlet complete. (DSR 12.22)
26Regrading terracing of mud phaska covered with tiles or brick, in cement by dismantling tiles or bricks, removing mud plaster, preparing the surface of mud phaska to proper slope, relaying mud plaster gobri leaping and tiles or bricks, grouted in cement mortar 1:3 (1 cement : 3 fine sand), including replacing unserviceable tiles or bricks with new ones and disposal of unserviceable material to the dumping ground (the cost of the new tiles or brick excluded), all complete as per direction of Engineer-in-Charge.(D.S.R 14.13)
27Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3mm thick water proofing membrane, black finished reinforced with non- woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 ltr/sqm. by the same membrane manufacturer of density at 25°C, 0.87-0.89 kg/ltr and viscosity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under :Joint strength in longitudinal and transverse direction at 23°C as 650/450N/5cm.Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane. : 3 mm thick (DSR 22.20.1)
28Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete : 250x16 mm DSR 9.62.2
29Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :100x10 mm DSR 9.63.4
30Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete:100 mm DSR 9.66.2
31Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete. 200 mm weighing not less than 120 gms. DSR 9.68.3
32Dismantling cement asbestos, Celotax or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead. DSR 15.41
33Providing & Fixing 0.50mm thick PPGI Sheet roofing including vertical/curved surface fixed with polymer coated with Screws and bitumen & G.I. limpet washers or with G.I. limpet washers on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
34PUBLIC HEALTH ITEMS
35Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
36Office Ground Floor
37Common toilet
38Office Office First Floor
39Common toilet
40Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
41Residential Quarter
42Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require
43White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
44Office Ground Floor
45Common toilet
46Office First Floor
47Common toilet
48Residential Quarter
49Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 32 mm dia
50Office Ground Floor
51Common toilet
52Office First Floor
53Common toilet
54Residential Quarter
55Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required
56Office Ground Floor
57Common toilet
58Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931
59Office Ground Floor
60Common toilet
61Office First Floor
62Common toilet
63Residential Quarter
64Providing and fixing C.P. brass bib cock of approved quality conforming toIS:8931 :
6515 mm nominal bore
66Office Ground Floor
67Common toilet
68Office First Floor
69Common toilet
70Near Water Cooler
71Residential Quarter
72Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.
7315 mm nominal bore
74Office Ground Floor
75Common toilet
76Office First Floor
77Common toilet
78Near Water Cooler
79Residential Quarter
80Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore
81Office Ground Floor
82Common toilet
83Office First Floor
84Common toilet
85Residential Quarter
86Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing
87Rectangular shape 453x357 mm
88Office Ground Floor
89Common toilet
90Office First Floor
91Common toilet
92Residential Quarter
93Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet
94100 mm diameter
95Office Ground Floor
96Common toilet
97Residential Quarter
98Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :
99610x510 mm bowl depth 200 mm
100Residential Quarter
101Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms
102Office Ground Floor
103Common Toilet
104Office First Floor
105Common Toilet
106Residential Quarter
107Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall 15 mm dia nominal bore
108For Residential Quarters & Office Toilet
109For Residential Quarters & Office Toilet
110Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work)
11115 mm nominal bore
11225 mm nominal bore
113Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge.
114Elbow 90°
115For 15.88mm outer dia pipe
116Providing and fixing brass grating of approved quality and colour
117Circular type:75 mm nominal dia
118Office Ground Floor
119Common Toilet
120Office First Floor
121Common Toilet
122Residential Quarter
123Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design
124100x100 mm size P type
125With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
126Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. : Granite Stone of approved shade
127Office Ground Floor
128Common Toilet
129Providing and fixing of CP extension of size 15 mm. Heavy Duty complete in all respect
13015 mm nominal bore
131Office Ground Floor
132Common toilet
133Office First Floor
134Common toilet
135Near Water Cooler
136Residential Quarter
137Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
138Office Ground Floor
139Common toilet
140Office First Floor
141Common toilet
142Residential Quarter
143Providing and fixing of ball cock of 20 mm complete in all respect as per the entire satisfaction of Engineer in Charge
144Office Ground Floor
145Common toilet
146Office First Floor
147Common toilet
148Residential Quarter
149Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m
150All kinds of soil.
151Outside drain channel
152Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design
153150 mm diameter S.W. pipe
154200 mm diameter S.W. pipe
155Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete
156150 mm diameter
157200 mm diameter
158Providing and fixing in position precast R.C.C. manhole cover and frame of required shape and approved quality
159Circular shape 560 mm internal diameter
160Constructing masonry Chamber 120x120x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :
161With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
162Providing and fixing soil, waste and vent pipes :
163100 mm diameter
164Sand cast iron S&S pipe as per IS: 1729
16575 mm diameter
166Sand cast iron S&S pipe as per IS: 1729
167Providing and fixing collar : 100 mm
168Sand cast iron S&S as per IS - 1729
16975 mm diameter
170Sand cast iron S&S as per IS - 1729
171Providing Drip Seal Joints to sand cast iron/centrifugally cast (spun) iron pipes & fittings of dia
172100mm
173Providing and fixing plain bend of required degree
174100 mm dia
175Sand cast iron S&S as per IS - 1729
17675 mm diameter
177Sand cast iron S&S as per IS - 1729
178Providing and fixing of Crompton Greeves 1 HP wapter pupm with help of fasteners to be fixed at sie as per entire satisfaction of Engineer in charge
179Extra cutting through metalled road and their foundation including sorting screening ans stacking at the site. Complete in all respects.
18010\\" line
181Supplying and filling in plinth with Jamuna/local fine sand under floors including, watering, ramming consolidating and dressing complete
18210\\" line
183Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
184As per quantity
185Carriage of material by mechanical transport including loading, unloading and stacking
186Earth : As per quantity
187Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms
188Office Ground Floor
189Common toilet
190Office First Floor
191Common toilet
192Residential Quarter
193ELECTRICAL ITEMS
194Providing and Fixing of LED luminarie recess/ surface mounting, Power coated housing made of CRCA sheet or its equivalent of size 2'x2' of 36-40 watt including driver with system Lumens 3600-4000 Im having efficacy of minimum 100 lm/W. THD <10%, PF > 0.95, Having coloured temperature 5700-6500 K recess type suitable to be fixed in Armstrong/ grid ceiling. The fitting should provides soft light and glare free symmetrical illumination and is to be fixed in the existing false ceiling frame of make Philips/ Wipro/ Osram/ Havells/ Trilux/ Mayfair/ Surya alongwith connection, testing and commissioning etc. The fitting may be installed at the height of 20 feet. There should be a on site warranty for 5 years. This job also inclusive of all material required at site for entire satisfaction of Engineer-in-charge.
195S / E of ceiling fans complete with aluminium blades, plastic canopies 2 Nos. double bal bearing, MS hanging rods, condenser, reels, clamps etc. The body of fan and blades should be white in colour. The job includes the cost of making necessary connections from the adjacent light point with 1.5sq.mm single core copper conductor cable. The sample of fans shall be gotapproved from the Engineer-in-charge of work before installation at site. The job also includes the cost of carriage, erection, testing, commissioning of fan, all labour and petty material required to complete the job to the entire satisfaction of the Engineer-in-Charge.[Size56\\" 1400mm sweep ceiling fan of Havells make Velocity White / Orient make Summer Breeze Crompton make Cool Breeze / Usha make Apollo Bajaj make Sabse. Tez only
196Full stator copper rewiding of an ceiling fan (condensor type) of 1200 mm sweep including (ball bearing if required) and cleaning and insulating the stator slots, sleeving, soldering, wrapping of cotton tape, re-assembling, varnishing and testing etc. complete in all respect. (in working condition)
197Supply & Erection of 18-20W LED with Batten/channel light with system Lumens 1800-2000 having efficacy 100 lm/W; THD <10%, Power factor >0.9, CCCV driver, Surge protection 2.5 kV; Operating Voltage Range - 100V - 300Volts. The luminaire housing should made of aluminium Extruded body. Ref- Make of Philips/ Osram/ Wipro/ Surya/ Crompton/ Bajaj total system Power consumption 18-20 Watt complete in all respect as required. The fitting should provides Elegantly designed and glare free light and specification of LM-79 and LM-80. The fixture should be comprehensively warranted to be repaired or replaced for any defect within 2years of installations.
198Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
199Supplying and fixing suitable size G.I. box with modular plate and cover in Front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
200Supply and Erection of Exhaust fan (heavy duty motor with copper wound metallic body) following size complete with motor, mettalic blades, double ball bearing with minimum power consumption, rigid frame with rubber mounting for silent operation,epoxy powder coating along with mettalic louver to be installed in the existing opening including cost of making the hole to suit the size of above fan making good the damage, Carriage charges connection, testing, commissioning etc. as required to complete the job to the entire satisfaction of EIC. Size 12\\" Sweep 900 RPM with louver of Havells make Turbo Force SP/ Orient make Industrial heavy duty / Crompton make HDEF EXHD 300- 6-1 / Bajaj make Supreme DLX only.
201S/F PVC Conduit:Supplying & Fixing of following sizes of PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. The work shall be executed to the entire satisfaction of Engineer in charge. 25 mm
202S/F PVC Conduit:Supplying & Fixing of following sizes of PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. The work shall be executed to the entire satisfaction of Engineer in charge. 32 mm
203Wiring in existing conduit:Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. Universal/ Finolex/ Polycab/ KEI/ Havell's/ Cirtina or Technically equivalent. The specifications complete in all respect and to the entire satisfaction of Engineer-in-Charge. Size 3 x 1.5 mm2
204Wiring in existing conduit:Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. Universal/ Finolex/ Polycab/ KEI/ Havell's/ Cirtina or Technically equivalent. The specifications complete in all respect and to the entire satisfaction of Engineer-in-Charge. Size 3 x 2.5 mm2
205Wiring in existing conduit:Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. Universal/ Finolex/ Polycab/ KEI/ Havell's/ Cirtina or Technically equivalent. The specifications complete in all respect and to the entire satisfaction of Engineer-in-Charge. Size 3 x 4 mm2
206Wiring in existing conduit:Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. Universal/ Finolex/ Polycab/ KEI/ Havell's/ Cirtina or Technically equivalent. The specifications complete in all respect and to the entire satisfaction of Engineer-in-Charge. Size 3 x 6 mm2
207S/F modular type switch/socket: Supplying and fixing following modular switch /socket on the exisiting modular plate & switch box including connections but excluding modular plate Anchor/ Havell's/ Panasonic/ Philips or it's terminal equivalent make in recess etc as required.
20815/16 Amp switch
2096 pin 15/16 Amp socket outlet
2105/6 Amp switch
2113 pin 5/6 Amp socket outlet
212Supply and Erection of bakelite sheet of 3mm with cutting & making good etc. on the existing M.S. boxes with suitable size of screws & washers etc. The work shall be executed to the entire satisfaction of Engineer-in-Charge.
213S/F’C series, DP MCB Supply and fixing 6 amps to 32 amps rating, 240 volts ‘C’ series, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB Complete with connections testing and commissioning etc as required. Double pole 16 Amps “C” series Make of Anchor, Havells, Legrand, ABB, Siemens, L&T. The work shall be executed to the entire satisfaction of Engineer in charge.
214Point wiring in PVC conduit, with modular type switch: Wiring for light point/fan point/exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulted copper conductor single core cable in surface/ recessed PVC Conduit with modular switch, modular plate, suitable G.I. box and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc as required. Group-C
215Twin Control point wiring in PVC conduit with modular type switch: Wiring for Pin control light point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface / recessed PVC Conduit with two way modular switch, modular plate, suitable G.I. box and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc as required.
216Supplying and fixing of modular type electronics fan regulator:-Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
217S/F modular boxes, base & cover plate: Supplying and fixing following size/modules, G.I. box alongwith modular base & cover plate for modular switches Anchor/ Havell's/ Panasonic/ Philips or it's terminal equivalent make in recess etc as required.
2181 or 2 Module (75mmX75mm)
2196 Module (200mm x 75mm)
22012 Module (200mmX150mm)
221Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required. Group C
222Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door Make of Panasonic, Anchor, Havells, Legrand, ABB, Siemens, L&T. The work shall be executed to the entire satisfaction of Engineer in charge. (Note : Vertical type MCB TP DB is normally used where 3 phase outlets are required.)
223S&E of Mouled Case Circuit Breakers (MCCB) of rating 63 Amp with Breaking Cap 16 kA, 415 Volts.Supply & Erection of 3 pole, 16 kA, 63 Amp MCCB with adjustable thermal and magnetic setting having Ics 75% of Icu. The MCCB is to be fixed in the feeder pillar complete in all respects. The MCCB should be make Havells/ ABB/ L&T/ Legrand/ Schneider. The work shall be executed to the entire satisfaction of Engineer-in-Charge.
224Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. Make Havell's/ Indo Asian/ L&T/ Schneider/ ABB/ Anchor. The specifications complete in all respect and to the entire satisfaction of Engineer-in-Charge. 100 A 16 KA 3 Pole
225S/F’C series, SP MCB Supply and fixing 5 amps to 32 amps rating, 240 volts ‘C’ series, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB Complete with connections testing and commissioning etc as required. Single pole 16 Amps “C” series Make of Anchor, Havells, Legrand, ABB, Siemens, L&T. The work shall be executed to the entire satisfaction of Engineer in charge.
226G.I. Earth pipe electrode with salt/ Charcoal: Supply and laying of earth electrode made out of ISI marked 'B' class earthing with G.I. earth pipe 4.5 mtr long, 40mm dia including accessories, G.I. pipe electrode shall be cut tapered at the bottom, and provided with holes of 12mm dia, drilled not less than 7.5 cm from each other upto 2 Mtr. of length from bottom (with charcoal or coke and salt). The earth electode shall be laid in ground after boring as per CPWD specifications complete in all respect and to the entire satisfaction of the engineer-in-charge.
227P/F 6 SWG GI earth wire in pipe: Providing & laying earth connection from earth electrode with 6 SWG dia G.I. wire in 15 mm dia G.I. pipe from earth electrode, as required.
228S/E of CC Collars including following:- a) The box shall be enclosed in a cement collar made from cement concrete 1:2:4 with outside dia 16”. b) The collar shall be embedded in the group upto 6” shall stand 9” above ground shall have housed 12” high SMC Box and 6” top over the box.c) The collar shall be provided with 2 G.I. Pipe of 40mm dia and 45cm long to facilitate entry of cables in the junction box after digg out the cable loops from earth complete in all respects, connetions etc.d) The collar shall be plastered properly finished, curing and painted with 2 coats of snowcem of superior quality.e) Providing and Fixing junction box of size 250x200x100mm inside dimensions of thermosetting sheet moulding compound material of robust construction with double hinge, side clamp locking arrangement. The existing ckt cable loops be made properly connection after digging from the earth and refilling the same position. There should be a terminal Strip (Thimble type) 30 amp, one no. Kitkat, rating suitable for minimum 4x16 sq.mm aluminum cable termination. The sheath of the armoured cable should be properly thimbed with the pole for proper earthing. Curing of CC Collar must be done as per satisfaction of Engineer-in-charge. The junction box should have two numbers PVC Glands with sufficient space for cable entry and loose wires complete in all respect.
229Supply & laying of ISI marked 4 core 16 mm sq PVC Insulated Aluminium armoured cable loose in trench/pipe:-Supply & laying of ISI marked 4 core 16 mm sq PVC Insulated Aluminum conductor armoured cable of make Havells/ Finolex/ Ecko/ Lapp/ Sunhome/ Polycab/ KEI/ Panasonic conforming IS:1554 (Pt.1) amended. The cable to be laid in trench/ pipe as per DSR Code 7.5.1/2018 MV CB PIP-25 Part-II (External). Material Testing report to be submitted and material to be supplied at site after confirmation from Engineer-in-charge. The work shall be executed to the entire satisfaction of Engineer-in-Charge.
230Supply & Laying of DWC pipe 51/63mm with hand bockey:- Supply and Laying of pipe (OD-63 mm & ID-51 mm nominal) Double Wall Corrugated (DWC) With Hand Bockey High Density Polyethylene pipe ISI marked (HDPE Density 240 to 958 KG/Cm3) having corrugation on the outer wall and plain surface inner wall with average wall thickness for outer layer as 1.1+0.1mm and for inside layer 1.2+0.1mm maintenance free, ‘C’ value over 150 with lowest frictional losses, anti rodent, inflammable & good weathering resistance, with all accessories like socket, bend, couplers etc. conforming to IS 14930, part ii complete with fitting and cutting, jointing etc.direct in ground (depth as per the direction of Engineer in charge and upto 75 cm below ground level) including excavation and refilling the trench but including sand cushioning and protective covering etc., complete as required and PSEN-50086 (P-I & II) of Make Gemini, Zen, Duraline, Crescent, Sunrise. The entire satisfaction of Engineer-in-Charge of work.
231Supply & Laying of DWC pipe 51/63mm without hand bockey:- Supply and Laying of pipe (OD-63 mm & ID-51 mm nominal) Double Wall Corrugated (DWC) Without Hand Bockey High Density Polyethylene pipe ISI marked (HDPE Density 240 to 958 KG/Cm3) having corrugation on the outer wall and plain surface inner wall with average wall thickness for outer layer as 1.1+0.1mm and for inside layer 1.2+0.1mm maintenance free, ‘C’ value over 150 with lowest frictional losses, anti rodent, inflammable & good weathering resistance, with all accessories like socket, bend, couplers etc. conforming to IS 14930, complete with fitting and cutting, jointing etc. direct in ground (depth as per the direction of Engineer in charge and upto 75 cm below ground level) including excavation and refilling of digging including sand cushioning and protective covering etc., complete as required and PSEN-50086 (P-I & II) of Make Gemini, Zen, Duraline, Crescent, Sunrise. The entire satisfaction of Engineer-in-Charge of work.
232PAINTING & NUMBERING OF POLES 7.5/9 MTR. LONG: -Painting of poles above ground level with two coats of black paint of Nerolec/ Asian/ ICI duly approved by the Engineer-in-charge. The pole surface should be cleaned well by removing dust/ rust & other depositions & smoothened with the sand paper/Iron brush & proper filling be made before painting. For numbering of poles the base should be painted with yellow and the number should be written in black letters of 3” in length. The Cement collar around the pole should be painted with two coats of good quality white colored snowcem. The job includes all type of bracket for painting, the cost of paint of existing Junction box cover with Red paint and any other petty material require to complete the job to the entire satisfaction of Engineer-in-charge.
233S/E of M.S. bracket make out of M.S Channel of size 7.5mm x6mm & M.S. flat of size 12”x9” welded on the top of the M.S. Channel. The bracket should be painted with the coats of superior quality paint. The job includes all the material, labour including making holes in the bracket to fix the flood light fittings etc, complete in all respect. The work shall be executed to the entire satisfaction of Engineer-in-Charge.
234Supply,Installation, Testing and Commissionng of wall fan 400 mm (ISI mark) including cost of petty material required to complete the job in all respect. (Make Crompton/Havells / Armonard/ Bajaj) complete in all respect.There shall be free replacement at site for a period of five year from the date of delivery, Toll free number shall be provided by the supplier to the client Exhaust fan , wall fan etc. Complete in all respect, as required.
235Making of haudi of 1.5'x1.5' size for drawing of underground cable etc constructed with bricks wall 4 ½\\" thick and plastered from the inner side with cement, sand, mixture 1:5. The RCC cover moulded in an angle frame of size 35mm x 35mm x 5mm should be provided above the Haudi which should rest on 40mm x 40mm x 5mm angle iron frame fixed on the upper portion of the Haudi. The cover should be provided with lifting arrangement. The rate includes all labour and material to complete the job with 1:4 CC mixture.
236Supply and Erection of High Range Sound Industrial Gong Bell. The work shall be executed to the entire satisfaction of Engineer in charge.
237S/F Ceiling rose:Supplying and fixing 3 pin, 5Amp ceiling rose on the existing Junction box/wooden block including connection etc as required.
238S/F brass holderSupplying and fixing brass batten/ angle holder including connection etc as required.
239Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. The work shall be executed to the entire satisfaction of Engineer in charge. Make: Havell's/ Panasonic/ Polycab/ Ecko/ KEI 4 X 10 sq. mm + 2 X 6 sq. mm earth wire
240Supply& Erection of PVC insulated 2 core 10mm2 aluminium conductor twin core flat of Rolex/ Sunhome/ Polycab/ Shalimar/ Havell's.The work shall be executed to the entire satisfaction of Engineer-in-Charge.
241Supply and Erection of Dummy complete with Testing and Commissioning etc. as per entire satisfaction of Engineer-in-Charge.
242Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. Group-C
243S/F call bell/ buzzer: Supplying & Fixing call bell/ buzzer suitable for D.C./A.C. single phase, 230 volts, complete as required.
244S/F DP MCB isolator: Supplying & fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make of Anchor, Havells, Legrand, ABB, L&T, Siemens. The work shall be executed to the entire satisfaction of Engineer in charge. 63 amps
245S&E of Outdoor type both side with L-key lock arrangement openable M.S. Cubical Pedestal of size 1200mmx 900mm x350mm fabricated from 16 G.M.S. sheet welded on M.S. angle iron frame of size 50mmx 50mm x6mm with 4 Nos. legs of angle iron of same size each of length 600mm with M.S. sheet of size 100mm x 100mm x 6mm thick at the bottom of the legs. The front side and the back side of the pedestal should be openable with hiunged door provided with Godrej type locking arrangements. A 'U' type support made from M.S. sheet of 16 G having width 75mmx 6mm be welded vertically in the inner side of the door to avoid entry of water. The door of the pedestal should be provided with rubber gasket to avoid entry of other insects etc. The top of the pedestal shall be covered with canopy made out of 16 G M.S. sheet projected outside to avoid entry of water. Four No. supporting members each of size 50mm x 6mm thick according to cubical size shall be welded for mounting switcher gear i.e. ICTPN, BBC, Timer and energy meter etc. The Pedestal shall be painted with two coats of P.O. red paint after applying one coat of red oxide. One No. The legs of the pedestal shall be embedded in the 1:2:4 C.C. mixture by digging 1' deep pit of 1' dia.The letter 'M.C.C.' in 4\\" size shall be written on the front door of the Pedestal. The job also included supply and erection one no. wooden plank/ board of size 1’-6’’ x 1’-6’’ and 25mm thick suitable for fixing energy mater including cost of screw, nuts and bolts in cubical pedestal complete in all respect. The pedestal will be housed on RCC foundation, Snowcem and platform of size 900mm deep (450mm underground and 450 mm above ground x 960 mm long x 410 mm wide including sufficient number of DWC pipe size of 51/63mm pieces to facility to entire the main cable and the circuit cable. The work shall be executed to the entire satisfaction of Engineer-in-Charge.
246S&E of Sheet metal/iron clad Triple pole switch with neutral link 63 Amp. 415 Volts. (with side handle)Supply & erection of 63 A/415 Volts ISI marked sheet metal iron clad switch of make Havells/ Standard/ L&T/ ABB/ Panasonic on existing surface with G.I. Bolts & Nuts/rag bolts and nuts etc., according to the size of holes in the body of the switch including bonding to the existing earth. The work shall be executed to the entire satisfaction of Engineer-in-Charge.
247Supply & Erection of Three Phase Aluminum Bus BarSupply & Erection of Three Phase Aluminum Bus Bar of size 300mmx 25mmx 5mm with L type fuse unit to be fixed on Porcelein insulators in the existing pedestal with required nuts, bolts & M.S. sheet. The fuse links should be equal to the number of outgoing circuits. The work shall be executed to the entire satisfaction of Engineer-in-Charge.
248Supply & Erection of Three Phase Automatic Timer and Contactor assembled in 22 gauge CRCA sheet enclosure duly powder coated with the following accessories (Three Phase) of Make Amsons/ L&T/ Scheinder or equivalent as approved by the Engineer-in-Charge. It shall conform to latest relevant IS Code:-1. It shall have 3 contactors of capacity 40 Amp. each of made BCH, Legrand, L&T or Siemons. The contractor should be of AC-3 duty 2 pole, 220/240 V coil Voltage.2. It shall have Auto/Manual switch, light activated switching system with allied accessories as required. 3. It shall have kit-kat fuse unit of 40 Amp capacity. The fuse unit shall conform to latest relevant IS code for protection of timers, bakelite sheet & other components as per requirement as site. 4. It shall be housed in a powder coated 22 gauge M.S sheet cabinet fo its protection. 5.The device shall be provided/fixed in the existing pedestal box in such a way so that it operates at correct time i.e. at rising/setting of Sun. The Sensor shall be included time watch to operate as required. The work shall be executed to the entire satisfaction of Engineer-in-charge. Warranty:- IT SHOULD STAND WARRANTY FOR ONE YEAR TOWARDS ANY MANUFACTURING DEFECTS.
249Supply & laying PVC insulated Aluminum Conductor armoured ISI Marked cable of 3.5 Core 35 mm sq in Trench/Pipe. Supply & laying of ISI marked 3.5 core 35 mm sq PVC Insulated Aluminum conductor armoured cable (PVC Sheated) of make Havells/ Finolex/ Cirtina/ Ecko/ Lapp/ Polycab/ KEI conforming IS:1554 (Pt.1) amended. The cable to be laid in trench/ pipe as per DSR Code 7.5.1 MV CB PIP-25 Part-II (External). The work shall be executed to the entire satisfaction of Engineer-in-Charge. The specification of the cable as below:- i) Conductor – Aluminumii) Core – 3.5iii) Working Voltage – 1100 Viv) Nominal Cross Section – 35mm2 v) Minimum No. of Wire – 7/6The work shall be executed to the entire satisfaction of Engineer-in-Charge.
250Supply of 40 Watt LED integrated Post Top fixture of die cast alum base and spun aluminium round top. LEDs are mounted directly on die cast alum heat sink suitable for mounting on pole having dia 60-75mm, luminary efficancy should be more than 100 lumens/watt. Power factor more than 0.95, CCT 4000-6000K ± 275, IP 65 Protection, System driver efficiency more than 85%, input volatge 100-270V, with opal/frosted/prismatic, P.C./ PMMA diffuser & inbuilt surge protection of 4 kV & external surge protection of 10kV. Make Philips, Wipro, Surya, Twinkle, Legero, Havells .The fixture is to be installed on the pole with or without suitable size reducer as per requirement. The job include the cost of supply and including the cost of reducer on the pole for erection of fixture.The fixture should be comprehensively warranted to be repaired or replaced any defect within five years of installation. The work shall be executed to the entire satisfaction of Engineer-in-Charge.
251Supply & Erection of high power 80 Watt LED Flood Light luminaries System lumen efficacy 105 <120 lm/Watt:High-brightness White LEDs sources with high transmittance LENS on each LEDs, System lumen efficacy 105 <120 lm/Watt, in Maximum 80 Watt Max Power System Consumption with 110 lms/Watt system luminous efficacy, 4000 + 275 Kcolor temperature & 70 CRI value for ensuring good quality light output. Life of at least 50,000 hours at 70% lumen maintenance & LED Potted driver efficiency >95% Power factor greater than 0.90, THD<10% & min 4KV surge protection with operating voltage range from 120-270 V for ensuring lifelong high performance of luminaire, having in built protection against short circuit mis wiring, over voltage protection, the fixture is made of LM-6 Pressure die-cast aluminum with engraved company name & have IK08 & above, IP66 Class I protection with NABL Accredited LM-79 & LM-80 Report. The fixture should be comprehensively warranted to be repaired or replaced for any defect within 5 years of installations. The luminary should not be over power derived. The fitting shall be mounted on the plate bracket on existing pole including making connection, testing & energizing complete in all respect to the entire satisfaction of Engineer-in-charge. The LED Flood light Fixture shall be installed on 12.5 mtr long pole. The luminary should be Wipro/ Bajaj/ Philips/ Crompton/ Osram/ Havells/ Trilex/ Panasonic/ HQ. The detailed specification for supply of 80 Watt Max Power LED Flood light luminaries is as under (with 05 years warranty) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57124568
AUTHORITY Local Bodies
TENDER VALUE 61.79 Lakhs
LAST DATE 28-08-2026
Authority
Authority Name Municipal Corporation
Work Description Tender for Special Repair / Renovation Of Fire Station Building & Residential Quarters In Sector 38-C, Chandigarh (Composite Work)
Basic Detail
Tender No MCC/R1/2026/141
Bidding Type Tender
Location
City Chandigarh
State Chandigarh
Key Dates
Publish Date 21 Aug 2026
Submission Date 28 Aug 2026
Open Date 28 Aug 2026
Finance
Tender Value 61.79 Lakhs
Tender Fee 3000
EMD 1.23 Lakhs
Exemption Not Available
Document List
BOQ_116454.xls
d8e49748-e0f5-4d07-b74a-78ec495c4b68.html
Tendernotice_1 (19).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Aug 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.