Agriculture Government Departments Closing in 18 days TDR #57124367

Tender For Internal Electrification In C-Type Shop - 10 Nos, B-Type Shop - 10 Nos And Distribution And Repairing Of Lt Line, Painting Of Pole, Lighting Arrangement And Cabling Work At Nmy Gopiganj.

Issued by Government Departments · Varanasi, Uttar Pradesh
Tender Value
11.27 Lakhs
Estimated cost
Bid Submission
10 Sep 2026
18 days left
EMD
1.13 Lakhs
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Varanasi → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Internal Electrification In C-Type Shop - 10 Nos, B-Type Shop - 10 Nos And Distribution And Repairing Of Lt Line, Painting Of Pole, Lighting Arrangement And Cabling Work At Nmy Gopiganj.

BOQ

Name of Work:- Internal electrification in C-type shop - 10 Nos, B-Type shop - 10 Nos and distribution and Repairing of LT line, painting of pole, lighting arrangement and cabling work at NMY Gopiganj.
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group A 1.10.1
2Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group A 1.10.1
3Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch + 3 pin 5/6 A socket outlet. 1.24.1+1.24.4
4Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way, Double door 2.3.1
5Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door 2.3.2
6Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole. 2.10.3
7Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole. 2.10.1
8Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. 5.2
9Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth ectrode including connection with G.I. thimble excavation and re-filling as required. 5.12
10Supply and fixing hexagonal Round G.P.fan box approved make made up of 1.0 mm thick ISI Marked G.P.sheet spot welded Four to Eight holes for pipe entry of the box. Holes should be semi-shuttered type with 0.5 mm G.P. Sheet made upper & lower cover duly screwed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material, labour, T&P etc. required for proper completion of the work. 1149
11Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A switch and 6 pin 15/16 A socket outlet. 1.24.3+1.24.5
12Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. As required. 3 Module (100mmX75mm) 1.27.2
13Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required. 1.12
14Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 1.25
15Supply and fixing of water tight oblong 10W LED bulkhead lumens having pressur die cost houghing with driver set confirm to IP 65 & above protection JK -08 high punity/transmisivity UV steplized non yellowish difuser/for uniform light distribution detuchable driver set, open and sort circuit protection, sutable for 24 hours continuous operation complete in all respect.1200 system lumens >120 Lm/W PF>0.95, CRI > 0.70 >300V over voltage protection, 4 KV internal surge protection, metal houghing with 5 years warrantee. 23.11
16Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire. 1.14.4
17Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.16 sq. mm 2 core 20a.1.3
18Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.16 sq. mm 4 core 20a.1.9
19S/F of 100mm dia GI pipe. DSR 2025 15.13.3
20LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt). Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 °C to 50 °C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-32, P. F.≥0.95, IP-66,IK-10, CRI ≥70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 120Watt LED Steet light. 8.14.16
21Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting offluorescent / HPMV / HPSV street light fitting on poleincluding bending the pipe to the required shape, 2nos 40 mm X 3 mm flat iron clamps with nuts, boltsand washer, painting the flat iron with primer and finishpaint etc. as required. 13.34
22Supplying and fixing PVC batten/ angle holder including connectionsetc. as required. 1.58
23Supply and erection of 63 Amp. TPN tap off box on rising mains complete with HRC fuses etc. complete in all respect. 913
24S&F of 100 A. 415 V Metal clad TPN CFS complete with HRC fuse etc. on angle iron frame complete in all respect. 353
25Shifting of pole & making foundation of damage pole. 616LR
26Supply & erection of \\"D\\" clamps of 50 mm x 6mm flat iron on steel tubular poles / steel rail poles with bolts, nuts etc. complete in all respects including painting with aluminium paint. 623
27Supply & fixing of 100 mm x 110 mm shackle insulator /100 mm x 80 mm pin insulator including G.I. Bolts / spindle nuts etc. complete in all respect. 621
28Supply & fixing of 230 mm x 32 mm x 1.5 mm galvanised steel strips including holes for shakcle insulators pins and bolts etc. complete in all respect. 622
29Supply & erection of hexagonal / cradle type gaused of G.I. wire no. 8 to 4 SWG including binding etc. complete in all respect. 629
30Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle ( 20 mm X 60 cm ), 7/ 4.00 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) oundation including excavation and refilling etc. as required. 13.1
31Supply & erection of overhead line with ACSR conductor on poles / service bracket including binding etc. complete in all respects. 627
32To tighting of old ACSR conductor. 627LR
33Supply & erection of overhead line with G.I. wire no. 8 to 4 SWG on poles/serivce bracket including binding etc. complete in all respect. 628
34Supply and burying of 600mm x 600mm x 6mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of one no. 8 to 10 SWG GI wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing (This will apply for earthing of poles also). 702
35Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth ectrode including connection with G.I. thimble excavation and re-filling as required. 5.12
36Painting of the electric pole with 2 coats of aluminium paint over red oxide primer complete in all respect. 634
37Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top as directed by Engineer in charge complete in all respect including excavationa dn fefilling the armounring of the cable shall be properly connected with the earth conductor by clamps etc. 16 sqmm 4core. 20a.1.9
38Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 16 sq. mm 2 core 20a.1.3
39S/F of 100 mm dia GI pipe. DSR 2025 15.13.3 Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57124367
AUTHORITY Government Departments
TENDER VALUE 11.27 Lakhs
LAST DATE 10-09-2026
Authority
Authority Name Rajya Krishi Utpadan Mandi Parishad
Work Description Tender for Internal Electrification In C-Type Shop - 10 Nos, B-Type Shop - 10 Nos And Distribution And Repairing Of Lt Line, Painting Of Pole, Lighting Arrangement And Cabling Work At Nmy Gopiganj.
Basic Detail
Tender No NIVIDA 1454 DATE 20.08.2026
Bidding Type Tender
Location
City Varanasi
State Uttar Pradesh
Key Dates
Publish Date 21 Aug 2026
Submission Date 10 Sep 2026
Open Date 11 Sep 2026
Finance
Tender Value 11.27 Lakhs
Tender Fee 2000
EMD 1.13 Lakhs
Exemption Not Available
Document List
89736cc4-0208-4dc1-bdb0-72e7116d428f.html
BOQ_2214622.xls
DOC.pdf
Tendernotice_1 (56).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Sep 11, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
html

89736cc4-0208-4dc1-bdb0-72e7116d428f.html

xls

BOQ_2214622.xls

pdf

DOC.pdf

pdf

Tendernotice_1 (56).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders