Tender For Construction Of New Control Room, Cable Trench, Junction Box, Road, Yard Fencing With Gate And Development Works At 132 Kv S/S Ashta.
Tender Value
1.13 Crore
Estimated cost
Bid Submission
10 Sep 2026
17 days left
EMD
2.26 Lakhs
Bank guarantee accepted
Document Fee
5900
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Sehore → Madhya Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of New Control Room, Cable Trench, Junction Box, Road, Yard Fencing With Gate And Development Works At 132 Kv S/S Ashta.
BOQ
| Sl. No. | Item Description |
| 1 | 132 KV S/s Ashta. |
| 2 | 166 NSOR 4000268 Stage-I- Complete structural work upto Plinth Beam Level as per Standard drawings and details mentionedas per Standard drawings and details mentioned in SMB vide page no. Vol-I/P-88 to 93 |
| 3 | 167NSOR 4000269 Stage-II-Complete structural work above Plinth Beam Level to slab cast leve l as per Standard drawings and details mentioned in SMB vide page no. Vol-I/P-101 to 110 |
| 4 | 168NSOR 4000270. Stage-III-Complete plaster (external and internal ), Sanitary fittings (excluding Sewage system), water supply fitting only, Rain water pipe, Grills, Shutters, flooring, doors and windows work etc. all complete. as per Standard drawings and details mentioned in SMB vide page no. Vol-I/P-118 to 134 |
| 5 | 169NSOR 4000271. Stage-IV-Complete Electrification works i/c all Electrical Fixtures. as per Standard drawings and details mentioned in SMB vide page no. Vol-I/P-135 to 139 |
| 6 | 170NSOR 4000272 Stage-V-Complete Putty and Painting as per Standard drawings and details mentioned in SMB vide page no. Vol-I/P-140 to 147 |
| 7 | 197NSOR 4000299 RCC Cable trench B Type Construction of civil work as per Standard drawings and details mentioned in SMB vide page No. Vol-II/P-22-25 |
| 8 | 199NSOR. 4000301RCC Cable trench D Type Construction of civil work as per Standard drawings and details mentioned in SMB vide page No. Vol-II/P-24to 26 |
| 9 | 300NSOR. 3018345 RCC Cable trench Cover for B Type cable trench, Construction of civil work as per Standard drawings and details mentioned in SMB vide page No. Vol-II/P-57 to 57 |
| 10 | 307NSOR 3018352 RCC Cable chequred plate for B Type cable trench, intallation Standard drawings and details mentioned in SMB vide page No. Vol-II/P-68 |
| 11 | 302NSOR 3018347 RCC Cable trench Cover for D Type cable trench, Construction of civil work as per Standard drawings and details mentioned in SMB vide page No. Vol-II/P-57 to 58 |
| 12 | 309NSOR 3018354 RCC Cable chequred plate for D Type cable trench, intallation Standard drawings and details mentioned in SMB vide page No. Vol-II/P-68 |
| 13 | 200NSOR 4000302 RCC Cable trench E Type Construction of civil work as per Standard drawings and details mentioned in SMB vide page No. Vol-II/P-30 to 32 |
| 14 | 206NSOR 4000308 RCC Cable trench at Road Crossing D Type Construction of civil work as per Standard drawings and details mentioned in SMB vide page No. Vol-II/P- 53to 56 |
| 15 | 209NSOR 4000311 PCC Road SMB Vol-II/P-62 to 63 |
| 16 | 226NSOR 4000327 Yard Fencing SMB Vol-II/P-118 to 120 |
| 17 | 315NSOR 3018360 GATE FOR YARD FENCING AND BOUDARY WALL 1 NO. (2X2.5X2.4 & 1 NO WINCKET (1X1.25X2.40) WITH 3 NO RCC COLUMN |
| 18 | 2.6, 3011472 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including dressing of sides and ramming of bottom disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed. (No extra lift is payable if work is done by mechanical means) All kinds of soil |
| 19 | 1.1.2.1, 3011322Transportation By Mechanical Transport including loading, unloading and stacking..Earth (for 1KM) |
| 20 | 2.27.1, 3011536 Supplying and filling in plinth under floors including watering ramming consolidating in layers not exceeding 20cm in depth and dressing complete….With hard muram having CBR >12 % at under floors including watering, ramming and compacting (minimum compaction 95% of MDD) in layers not exceeding 20cm in thickness and dressing complete. (Note:- maximum thickness of this layer to be provided shall be 30cm) |
| 21 | 40NSOR 3000145 Brick work with fly aish brick in plinth & foundation |
| 22 | 4.1.2.3, 3011580 With 40mm nominal size graded stone aggregate. M-7.5 Nominal Mix -1 Cement : 4 sand : 8 graded stone aggregate |
| 23 | 5.16.6, 3011694 Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including ……..Mild steel and Medium Tensile steel bars. |
| 24 | 5.1.1, 3011633 Providing and laying in position ……. M-20 Grade Concrete |
| 25 | 5.9.1,3011642. Foundations, footings, bases of columns, etc. for concrete upto plinth level |
| 26 | 10.2, 3012506 Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 27 | 10.22.1, 3012546 In stringers, treads, landings etc. of stair cases including use of chequered plate wherever required, all complete. (5 mm) |
| 28 | 13.64, 3013112 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work. |
| 29 | 11.53, 3012719 Providing and laying Antiskid floor tiles of any sizes, 12 mm thickness with water absorption less than 0.08% ……..cement : 4 sand) including grouting the joints with white cement with matching pigments etc., complete. |
| 30 | 13.2.2, 3013018. 15 mm cement plaster on the rough side of single or half brick wall of mix …...1:6 (1 cement : 6 sand) |
| 31 | 11.72.2, 3012749 Providing and laying factory made chamfered edge Cement Concrete paver blocks of required colour strength, thickness pattern, surface ...............per manufacturer'sspecifications and direction of Engineer-in- Charge. 60 mm thick C.C. paver block of M-35 grade |
| 32 | 11.22.2, 3012664 Providing and fixing 18 mm thick……… Engg. In chargeGranite fine grain drak cristle of other colour & various pattern |
| 33 | 5.9.2.1, 3011643Centering and shuttering in cluding strutting, propping etc. and removal of form for: Walls (any thickness) in cluding attached pilasters butter esses, plinth beams and string courses etc. Uptoplinthlevel. |
| 34 | 5.9.3, 3011653. Centering and shuttering in cluding strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform. |
| 35 | 13.5.1, 3013023. 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:3 (1 cement : 3 sand) |
| 36 | 20.10.1, 3014377\\"Boring, Providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M 25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, cement concrete and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) :.Note: - The minimum grade of concrete to be used for piling shall be M-20 and the minimum cement content shall be 400 kg/m3 in all condition. 250 mm diameter piles\\" |
| 37 | 5.2.1, 3011635. \\"Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in walls (any thickness), including attached pilasters, buttresses, plinth and\\" string courses, fillets, columns, pillars, posts and struts etc. above plinth level and upto floor two level excluding cost of centering, shuttering,finishing and reinforcement: M-20 Grade Concrete |
| 38 | 5.3.1, 3011636. Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in beams, suspended floors, roofs having slope of any degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases above plinth level and upto floor two level excluding the cost of centering, shuttering, finishing and reinforcement in concrete grade. M-20 Grade Concrete |
| 39 | 6.7.2.2, 3011783. Brick work with fly ash lime bricks (FALG Bricks) conforming to IS:12894-2002, in super structure above plinth level up to floor two level in : Having 75 kg / cm2 average compressive strength. Cement mortar 1:6 (1 cement : 6 sand) |
| 40 | 10.22.2, 3012547. Steel work welded in built up sections/framed work including cutting, hoisting,fixing in position and….In stringers, treads, landings etc. of stair cases including use of chequered plate wherever required, all complete. |
| 41 | 11.79.1.1, 3012765 Providing and laying vitrified floor tiles Multi/Double charged (Minimum top layer thickness 2.0mm) Neno Polished self design, in different size with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1st quality/ premium quality in skirting laid on 12mm thick cement mortar 1:4(1cement :4sand) including grouting the joints with white cement and matching pigments etc. complete In light shade glossy/ rustic /stain finished (a) Size 600X600 mm thickness 9-10 mm |
| 42 | 13.3.2, 3013020 20 mm cement plaster of mix : 1:6 (1 cement : 6 sand) |
| 43 | 13.8, 3013027 6 mm cement plaster of mix : 1:3 (1 cement : 3 sand) |
| 44 | 10.5.2, 3012510 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x5mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece. |
| 45 | 5.9.6, 3011656 Centering and shuttering in cluding strutting, propping etc. and removal of form for:….Columns, P i l l a rs, Piers, Abutments, Posts and Struts. |
| 46 | 21.1.1.2, 3014441 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion. Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 47 | 21.1.2.2, 3014444 \\"Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved .make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, .including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) .:For shutters of doors, windows and ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required .including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for .separately)..Powder coated aluminium (minimum thickness of powder coating 50 micron) .\\" |
| 48 | 21.3.1, 3014449 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item) : With float glass panes of 4.0 mm thickness |
| 49 | 13.49, 3013088. Wall painting by any mechanical or manual means with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ litre. of approved brand and manufacture, including applying additional coats wherever required to achieve even shade. |
| 50 | 13.52, 3013091 Finishing walls by any mechanical or manual means with Acrylic Smooth exterior paint (Economy Exterior) of required shade including all scaffolding. New work (Two or more coat applied @1.67ltr/10sqm over and including one coat undiluted exterior waterproofing coating @ 2.39 litre/10 sqm with crack bridging ability of upto 0.5mm on horizontal surfaces with an elongation of 150% and water proofing of upto 3 bars on vertical surface |
| 51 | 2.5, 3011471 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m lead and lift up to 1.5 m, disposed soil to be levelled and neatly dressed, All kinds of soil |
| 52 | 11.72.1, 3012748 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc. of required colour strength, thickness pattern, surface texture (smooth/rough) and size/shape, conforming to 15658- 2006 made by table vibratory method using PU mould, laid in required colour and pattern over 50mm thick compacted bed of sand, compacting and proper embedding/ laying of inter locking paver blocks into the bedding layer through vibratory compaction by using plate vibrator, filling the jointswith sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand including locking with M15 cement concrete in footpath, parks, lawns, drive ways or light traffic parking etc. complete as per manufacturer's pecifications and direction of Engineer-in- Charge. 80 mm thick C.C. paver block of M-35 grade |
| 53 | 28.10.5, 3014885 Grassing with Selection No.1 grass including watering and maintenance of the lawn for 30 days or more till the …………….roller, making the surface smoothen and light watering the same, as per direction of Engineer-in-Charge. |
| 54 | 28.15.1, 3014897 Providing and planting different variety of plants of approved quality and sizes as mentioned including making pits of ………..Tabernaemontana Divaricata, Tecoma Gaudi Chaudi, Tecoma, Stans, Thevetia Nerifolia, Thuja Compacta and equivalent plants. |
| 55 | 28.15.3, 3014899 Providing and planting different variety of plants of approved quality and sizes as mentioned including making pits of ……….. Aclypha (Red, Green,Mini), Lantana (Red, Yellow, Purple, White, verigated), Haemalia Mini and similar plants. |
| 56 | 4.1.1.2, 3011575 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level : With 40mm nominal size graded stone aggregate. M-10 Nominal (Mix -1 Cement : 3 sand : 6 graded stone aggregate) |
| 57 | 18.8.1.6, 3013866 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.Internal work - Exposed on wall..50 mm dia. nominal bore |
| 58 | 19.4.2, 3014216. Providing and laying below ground unplasticised PVC pipe to with stand ....160 mm diameter OD (min. wall thickness 4.0mm)160 mm sever line |
| 59 | 19.9.1.2, 3014244 \\"Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 sand ) R.C.C. top slab ... :..With Sewer bricks conforming to IS : 4885\\"M.H 40x80 |
| 60 | 19.9.2.2, 3014246.\\"Constructing brick masonry manhole in cement mortar 1:4 ( …..With Sewer bricks conforming to IS : 4885\\" M.H 120x80 |
| 61 | 19.20.1, 3014270 Supplying and fixing C.I. cover without frame for manholes : :..455x610 mm rectangular C.I. cover (light duty) the weight of the cover to be not less than 23 kg.100 mm CI cover |
| 62 | 19.31, 3014299Constructing soak pit 1.20x1.20x1.20m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20m long complete as per standard design. |
| 63 | 18.6.2.1, 3013847 Providing and fixing CPVC pipes…….15 mm nominal outer dia .Pipes. |
| 64 | 18.6.2.2, 3013848 Providing and fixing CPVC pipes……..20 mm nominal outer dia .Pipes. |
| 65 | 18.6.2.3, 3013849 Providing and fixing CPVC pipes……..25 mm nominal outer dia .Pipes. |
| 66 | 18.6.1.2, 3013842 Providing and fixing CPVC pipes,...20 mm nominal outer dia .Pipes. |
| 67 | 18.13.1, 3014056 Providing and fixing CPVC gate valve ...25 mm nominal bore |
| 68 | 4.1.1.2.2, 3015237Point wiring (excluding metallic switch box & sheet but including switches, …..connector for joints etc. as required as per specification for :- Light point/fan points.Primary medium point. (Using modular accessories) |
| 69 | 4.1.1.3.2, 3015239Point wiring (excluding metallic switch box & sheet but including switches, …..connector for joints etc. as required as per specification for :- Light point/fan points.Primary long point. (Using modular accessories) |
| 70 | 30.4.2, 3015463 Supplying, erection and testing of approved make 'Fresh air fan' AC 230-250 volts with connection and including frame bolt/anchor hole fasteners etc. complete finished and as required….225 mm sweep bush type |
| 71 | 8.1.1.3, 3015346 Power point wiring surface rigid P.V.C. conduit……Long point ..16 A |
| 72 | 27.8.1.2, 3016222 Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of 'C' series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures :- Single pole MCB SP 6Amp to 32Amp 10kA rating |
| 73 | 4.3.1.1, 3015266 Wiring for circuit wiring with PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping of ISI marked suitable size etc. as required as per specification ..Circuit wiring 2.5Sq. Mm (2X2.5) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 20, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysSep 11, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender