Defence Statutory Bodies & Commissions/Committees Closing in 24 days TDR #57122336

Tender For special Repair For Re-Routing Water Maint/Distribution Network For Certain Location Under Ge (U) W/S, Delhi Cantt-10

Issued by Statutory Bodies & Commissions/Committees · New Delhi, Delhi
Tender Value
2.38 Crore
Estimated cost
Bid Submission
17 Sep 2026
24 days left
EMD
3.13 Lakhs
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for special Repair For Re-Routing Water Maint/Distribution Network For Certain Location Under Ge (U) W/S, Delhi Cantt-10

BOQ

Name of Work:- SPL REPAIR FOR RE-ROUTING WATER MAINT/DISTRIBUTION NETWORK FOR CERTAIN LOCATION UNDER GE (U) W/S, DELHI CANTT-10
Sl. No. Item Description
1Excavation in trenches not exceeding 1.5 metres wide and not exceeding 1.5 metres deep for pipe line in soft/loose soil, getting out and levelling of bottom surface to required level complete all as specified and directed by Engineer-in-Charge
2Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engr-in-Charge.
3Removal of excavated material from site to a distance not exceeding 50 meters away and depositing where directed at a level not exceeding 1.5 meters above the starting point complete all as specified and directed by Engr-in-Charge.
4Excavation in trenches by cutting of road crossing, PCC hard standing for taking out/laying of pipe lines including PCC (1:2:4) type B-2 (with 40 mm graded aggregate) in foundations, filling and mass concrete complete including making good the existing surface complete all as specified and directed.
5Taking up/down old Cemented/GI/Nidhi/CI/MS Pipes including all fitting of the following sizes as specified and directed by Engineer-in-Charge :-
6(a) 100 mm bore
7(b) 150 mm bore
8(c) 200 mm bore
9(d) 250 mm bore
10Supply, laying jointing, testing DI pipe with class-K-7 spigot socketed ends , conforming to IS-8329 laid in trenches of the following sizes as specified and directed by Engineer-in-Charge:- (Note : Tyton Joint, Excavation & earth work shall be measured & paid separetely.)
11(a) 100 mm bore
12(b) 150 mm bore
13(c) 200 mm bore
14(d) 250 mm bore
15Supply, laying, jointing, testing of DI pipe with class-K-7 spigot socketed ends, conforming to IS-8329 in re-routing position all as per directions of Engr-in-Charge as per requirement of existing site, laid in trenches of the following sizes as specified and directed :- (Note : Tyton Joint, Excavation & earth work shall be measured & paid separetely.)
16(a) 100 mm bore
17(b) 150 mm bore
18(c) 200 mm bore
19(d) 250 mm bore
20Taking up old GI steel tubing with connection including fittings all as specified and directed of the follwing sizes :-
21(a) 15 mm bore
22(b) 20 mm bore
23(c) 25 mm bore
24(d) 40 mm bore
25(e) 50 mm bore
26Supply & Laying of GI pipe mediun grade ISI mark including all fittings in old/new positions in trenches/wall/floor complete and making good the distributed surfaces as per existing as directed of following sizes. Note : Excavation and earth work will be measured and paid separately.
27(a) 15 mm bore
28(b) 20 mm bore
29(c) 25 mm bore
30(d) 40 mm bore
31(e) 50 mm bore
32Supply & Laying of GI pipe mediun grade ISI mark including all fittings in old/new in re-routing positions in trenches/wall/floor complete and making good the distributed surfaces as per existing as directed of following sizes:-Note : Excavation and earth work will be measured and paid separately.
33(a) 15 mm bore
34(b) 20mm bore
35(c) 25mm bore
36(d) 40mm bore
37(e) 50mm bore
38Supply & Fixing Gun metal gate valve with iron wheel head screwed both ends for iron pipe and fixed, including taking out unserviceable gate valve bore of pipe of following sizes complete all as specified and directed by Engineer-in-Charge:-
39(a) 15 mm bore
40(b) 20 mm bore
41(c) 25 mm bore
42(d) 40 mm bore
43(e) 50 mm bore
44Material and labour for DI specials like bends, tapers any type any radius and angle, Tee pieces single branch `Y' junction, double branch, cross (all sockets or socket and spigot) collars, MJ Collors DI connecting pieces one end flanged and other end spigot/socket, reducers/bell mouth pieces one end flanged and other end tapering as bell mouth for the size up to 250 mm dia bore complete all as specified and directed.
45Material and labour for CI bends, tapers any type any radius and angle, Tee pieces single branch `Y' junction, double branch, cross (both all sockets or socket and spigot or flanged) collars, cast Iron connecting pieces one end flanged and other end spigot/socket, reducers/bell mouth pieces one end flanged and other end tapering as bell mouth for the size up to 250 mm dia bore complete all as specified and directed.
46Material and labour for Rubber Gasket Joint (Tyton Joint) including jointing material for DI/CI pipe of following size/bore :-
47(a) 100 mm bore
48(b) 150 mm bore
49(c) 200 mm bore
50(d) 250 mm bore
51Material and labour including jointing and testing of cast iron sluice valves class PN-1.0, conforming to IS:14846 flanged ends drilled having stainless steel spindle with cast iron wheel at top complete with nuts, bolts, washers and rubber gaskets including taking out unserviceable sluice valve and removal from site for the follwing sizes complete all as specified and directed :-
52(a) 80 mm bore
53(b) 100 mm bore
54(c) 150 mm bore
55(d) 200 mm bore
56(e) 250 mm bore
57Supplying, laying, jointing, welding and testing MS Pipe (Heavy class 'C') IS : 1239/3589, of followiing sizes laid in trenches or in Horizontal/Vertical/inclined position or laying on floors for connections for suction, to header and connected to outgoing water main CI/DI pipe line :- Note : MS Flanges including fabrication work will be measured and paid separately.
58(a) 100 mm Dia
59(b) 150 mm dia
60Supply and fixing in replacement of MS flange 100 mm bore ,16mm thick duly welded with flange joint including nuts bolts, washer, rubber or fiber board gasket joint of size 100 mm size complete all as specified and directed
61Supply and fixing in replacement of MS flange 150 mm bore ,16mm thick duly welded with flange joint including nuts bolts, washer, rubber or fiber board gasket joint of size 150 mm size complete all as specified and directed
62Material and Labour for PCC (1:3:6) type C2 using 40mm graded stone crushed aggregate as in foundation for including fair finish even and fair to exposed surfaces without using extra cement complete all as specified and directed.
63Boring holes under road pavement manually in any type of soil upto 350 mm bore complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57122336
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 2.38 Crore
LAST DATE 17-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for special Repair For Re-Routing Water Maint/Distribution Network For Certain Location Under Ge (U) W/S, Delhi Cantt-10
Basic Detail
Tender No CEDZ/TOKEN-29 OF 2026
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 20 Aug 2026
Submission Date 17 Sep 2026
Open Date 22 Sep 2026
Finance
Tender Value 2.38 Crore
Tender Fee 2000
EMD 3.13 Lakhs
Exemption Available
Document List
9c282811-568b-404d-bdfb-ab6597f55ad6.html
BOQ_880234.xls
Tender83237.rar
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 24 days
Sep 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 29 days

Tender Documents

Download All (ZIP) ↓
html

9c282811-568b-404d-bdfb-ab6597f55ad6.html

xls

BOQ_880234.xls

rar

Tender83237.rar

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders