Defence Statutory Bodies & Commissions/Committees Closing in 23 days TDR #57122319

Tender For Repair / Maintenance Of 33 Kv Main Receiving Station Yard And Other Allied Works At Kirby Under Age Em -I Of Ge (U) Electric Supply, Delhi Cantt-10.

Issued by Statutory Bodies & Commissions/Committees · New Delhi, Delhi
Tender Value
95.03 Lakhs
Estimated cost
Bid Submission
15 Sep 2026
23 days left
EMD
1.68 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair / Maintenance Of 33 Kv Main Receiving Station Yard And Other Allied Works At Kirby Under Age Em -I Of Ge (U) Electric Supply, Delhi Cantt-10.

BOQ

Name of Work:- REPAIR / MAINTENANCE OF 33 KV MAIN RECEIVING STATION YARD AND OTHER ALLIED WORKS AT KIRBY UNDER AGE EM -I OF GE (U) ELECTRIC SUPPLY, DELHI CANTT-10.
Sl. No. Item Description
1M & L for carrying out following onsite tests for 33 / 11 KV Transformer of any capacity with required / suitable testing equipment by qualified and licensed personal, recording test results and submitted to GE to keep on record duly signed by all concerned complete all as specified and as directed: [a] IR Test [b] PI [c] Magnetic Balance Test [d] Ratio test [e] Di-electric Test of Oil [f] Short Circuit Test [g] Vector Group [h] Winding Resistance
2M & L for carrying out following onsite tests for 11 / 0.433 KV Transformer of 100 KVA capacity with required / suitable testing equipment by qualified and licensed personal, recording test results and submitted to GE to keep on record duly signed by all concerned complete all as specified and as directed: [a] IR Test [b] PI [c] Magnetic Balance Test [d] Ratio test [e] Di-electric Test of Oil [f] Short Circuit Test [g] Vector Group [h] Winding Resistance
3M & L for painting of transformer of 8/10 MVA(2 Nos) / 12.5/16 MVA(1 No) capacity complete with two coats of synthetic enamel paint externally and painting with a coat of oil resistant paint inside the Transformer shell complete all as specified and as directed.
4M & L for overhauling OLTC of 33 KV / 11 KV Transformer of capacity 8/10 MVA (2 Nos) / 12.5/16 MVA( 1 No) by draining out of Transformer oil, dismantling of top cover, inspection of moving and fixed contacts of all three phases and checking the operation, cleaning and removal of contacts of all the three phases and checking the operation, cleaning and removal of all carbon particles, checking the thickness of leads in the OLTC board, moving / fixed contacts, inspection of transition resistance and replacement of gasket / contacts etc., if found damaged, reassembling complete, filling up of oil, testing complete all as specified and as directed. Note: Spares will be measured and paid separately
5M & L for filtration of transformer oil of transformers installed at various locations to achieve di-electric strength not less than 60 KV at 2.5mm gap as per relevant IS with portable filtration plant, testing of the oil for the di-electric strength before filtration and after filtration complete all as specified and as directed.
6Supply and topping up of transformer oil with di-electric strength not less than 60 KV in to the conservator tank / body tank of the transformer etc. complete all as specified and as directed.
7Supply only HV Bushings (Primary side) made out porcelain alongwith brass/copper bushing rod 33 KV and suitable length/size all as per existing, complete 12.5/16 MVA distribution transformers of any make/size/type all as directed including dismantling old one.
8-Ditto- all as per srl item No 7.00 here-in-before but 10 MVA
9-Ditto- all as per srl item No 7.00 here-in-before but 8 MVA
10Supply only HV Bushing (Secondary side) alongwith brass/copper bushing rod 11 KV with threading and suitable length/size all as per existing etc, complete 12.5/16 MVA capacity power transformers of any make/size/type all as directed including dismantling old one.
11-Ditto- all as per srl item No 10.00 here-in-before but 10 MVA
12-Ditto- all as per srl item No 10.00 here-in-before but 8 MVA
13S & F butterfly valve for radiatior suitable size all as per existing etc, complete for power transformers of any make/size/type all as directed including dismantling old one.
14S & F WTI (Winding Tempreture Indicator) for 8/10 MVA Power Transformer suitable size all as per existing etc, complete of any make/size/type all as directed including dismantling old one.
15S & F OTI (Oil Tempreture Indicator) for 8/10 MVA Power Transformer suitable size all as per existing etc, complete of any make/size/type all as directed including dismantling old one.
16S & F SRC gasket for 12.5/16 MVA Power Transformer suitable size all as per existing etc, complete of any make/size/type all as directed including dismantling old one.
17Supply & filling of Silica Gel in existing Breather of Power Transformer
18M & L for rewinding of cooling fan motor of size 24 inch including removal and refixing in its original position .
19Supply, install, testing and commissioning of REF 615, feeder protection and control relay, protections 50, 51, 50N, 51N, 46, 49, 64R, 67, 67N, 27, 59, 59N, 25, 81U, 81O, df/dt, 95, measurement for 3I, I0, 3U, U0, Kw, KVA, PF, Hz, Kwh, 12 DI + 10 DO, one front RJ45 Port, one rear RS485 port for modbus protocol, draw out type with CT shorting feature, small LCD display feature including taking down old relay of any description complete all as specified and as directed.
20Supply, Install, testing and commissioning of ABB make RET 620/615, Transformer protection and control relay, protections 87T, 64R [High and Low Impedance], 50, 51, 50N, 51N, 67, 67N, 46, 49, 37, 24, 27, 59, 59N, 81U, 81O, df/dt, 95, measurement for 3I, I0, 3U, U0, Kw, KVA, Kwh, PF, Hz, 8 DI + 13 DO, 2 RTD Inputs, 1 mA Input, One front RJ45 Port, One Rear RS485 Port for Modbus Protocol, Draw Out with CT Shorting feature including taking down old relay of any description complete all as specified and as directed.
21S & F in repairs master trip relay operating volt 100/110 V DC complete all as specified and as directed.
22S & F in repairs auxiliary relays 30Y type VAA for Transformer Protection complete all as specified and as directed.
23S & F in repairs digital voltmeter, 96 X 96 Sq.mm with 4 Position Selector switch complete all as specified and as directed.
24S & F in repairs digital ammeter, 96 X 96 Sq.mm with 4 Position Selector switch complete all as specified and as directed.
25S & F in repairs C.B. ON/OFF/TRIP/Trip Circuit Healthy and Unhealthy/Spring Charged complete all as specified and as directed.
26S & F in repairs 8 window annunciator complete all as specified and as directed.
27S & F in repairs T‐N‐C switch [Breaker Control Switch] complete all as specified and as directed.
28S & F in repairs trip circuit healthy push button complete all as specified and as directed.
29S & F in repairs control wiring, colour coded complete all as specified and as directed.
30S & F in repairs test terminal block complete all as specified and as directed.
31S & F in repairs local remote switch complete all as specified and as directed.
32Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, heavy duty cable, ISI marked with multistranded copper conductor 1100 Volt grade of size 14 Core, 2.5 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down old cables of any description complete all as specified and as directed. Please Enable Macros to View BoQ information
33Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, heavy duty cable, ISI marked with multistranded copper conductor 1100 Volt grade of size 14 Core, 2.5 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down old cables of any description complete all as specified and as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57122319
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 95.03 Lakhs
LAST DATE 15-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair / Maintenance Of 33 Kv Main Receiving Station Yard And Other Allied Works At Kirby Under Age Em -I Of Ge (U) Electric Supply, Delhi Cantt-10.
Basic Detail
Tender No CWE(U)/D-22/2026-27
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 20 Aug 2026
Submission Date 15 Sep 2026
Open Date 22 Sep 2026
Finance
Tender Value 95.03 Lakhs
Tender Fee 1000
EMD 1.68 Lakhs
Exemption Available
Document List
3d57dab7-7365-4d73-8b04-711b383f1d1a.html
BOQ_880231.xls
Tendernotice_1.pdf
TPD22.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 15, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 23 days
Sep 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 30 days

Tender Documents

Download All (ZIP) ↓
html

3d57dab7-7365-4d73-8b04-711b383f1d1a.html

xls

BOQ_880231.xls

pdf

Tendernotice_1.pdf

pdf

TPD22.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders