Tender For Repair/ Replacement Of Lt Panel, Junction Boxes, Perimeter/ Security Lights Including Lt Cable And Allied Items At Miran Sahib Under Ge Jammu.
Tender Value
30 Lakhs
Estimated cost
Bid Submission
10 Sep 2026
17 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jammu → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/ Replacement Of Lt Panel, Junction Boxes, Perimeter/ Security Lights Including Lt Cable And Allied Items At Miran Sahib Under Ge Jammu.
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep any type of soil getting out and levelling of bottom surface to required level for poles/ stay assembly/ cable complete all as specified and as directed. |
| 2 | Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25m thick complete all as specified and as directed. |
| 3 | Removing excavated material from site to a distance not exceeding 50mtr away and depositing where directed not exceeding 1.5mtr from the starting point complete all as specified and as directed. |
| 4 | Earth work in excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 Sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m complete all as specified and as directed by Engineer-in-Charge. |
| 5 | Supply, laying and fixing DWC HDPE pipe for protection cable (orange in colour) of size 75mm dia complete with fitting and including cutting, jointing and clamping complete all as specified and as directed. |
| 6 | Taking out old/ unserviceable underground LT cables and connections including pipes, bricks or precast concrete cable cover etc from trenches/ walls/ poles of any cross sectional area and removing from site complete all as specified and as directed. |
| 7 | XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 Sqmm, 3.5 core complete all as specified and as directed by Engineer-in-Charge.Note: - Wherever cable fixing/ connection, suitable thimble should be used as per site situation. |
| 8 | Description all as per Ser item No. 7.00 here-in-before but cross sectional area 35 Sqmm 3.5 core complete all as specified and as directed. |
| 9 | Description all as per Ser item No. 7.00 here-in-before but cross sectional area 50 Sqmm 3.5 core complete all as specified and as directed. |
| 10 | Description all as per Ser item No. 7.00 here-in-before but cross sectional area 70 Sqmm 3.5 core complete all as specified and as directed. |
| 11 | Description all as per Ser item No 7.00 here-in-before but cross-sectional area 10 Sqmm, 4 core complete all as specified and as directed. |
| 12 | Description all as per Ser item No 7.00 here-in-before but cross-sectional area 16 Sqmm, 4 core complete all as specified and as directed. |
| 13 | Description all as per Ser item No 7.00 here-in-before but cross-sectional area 10 Sqmm, 2 core complete all as specified and as directed. |
| 14 | Description all as per Ser item No. 7.00 here-in-before but cross sectional area 16 Sqmm, 2 core complete all as specified and as directed. |
| 15 | Supply and fixing in replacement unserviceable aluminium lugs/ thimble of size 70 Sqmm complete all as specified and as directed. |
| 16 | Supply and fixing in replacement unserviceable aluminium lugs/ thimble of size 50 Sqmm complete all as specified and as directed. |
| 17 | Supply and fixing in replacement unserviceable aluminium lugs/ thimble of size 35 Sqmm complete all as specified and as directed. |
| 18 | Supply and fixing in replacement unserviceable aluminium lugs/ thimble of size 25 Sqmm complete all as specified and as directed. |
| 19 | Material and labour in replacement of MCCB 4 Pole, current rating 160 Amp 36 KA at 415V, 50 Hz as per existing make complete all as specified and as directed. |
| 20 | Material and labour in replacement of MCCB 4 Pole, current rating 200 Amp 36 KA at 415V, 50 Hz as per existing make complete all as specified and as directed. |
| 21 | Material and labour in replacement of MCCB 4 Pole, current rating 250 Amp 36 KA at 415V, 50 Hz as per existing make complete all as specified and as directed. |
| 22 | Material and labour in replacement of MCCB 4 Pole, current rating 400 Amp 36 KA at 415V, 50 Hz as per existing make complete all as specified and as directed. |
| 23 | Material and labour in replacement of MCCB 4 Pole, current rating 630 Amp, thermal setting adjustable 70%-100% rupturing capacity 50 KA at 415V, 50 Hz as per existing make complete all as specified and as directed. |
| 24 | Supply and fixing in replacement of onload changeover switch AC-23 (side handle) in sheet metal enclosure of capacity 100 Amp, 415 volts 3 phase, four pole complete all as specified and as directed. |
| 25 | Supply and fixing in replacement of onload changeover switch AC-23 (side handle) in sheet metal enclosure of capacity 200 Amp, 415 volts 3 phase, four pole complete all as specified and as directed. |
| 26 | Supply and fixing in replacement of LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP 65/66 protection complete all as specified and as directed. |
| 27 | Supply and fixing in replacement of LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP 65/66 protection complete all as specified and as directed. |
| 28 | Supply and fixing in replacement of LED street light fitting 120 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP 65/66 protection complete all as specified and as directed. |
| 29 | Supply and fixing in replacement of LED flood light fitting of capacity 170 watt including inbuilt surge protection as per requirement LED flood light fittngs along with IP 65/66 protection complete all as specified and as directed. |
| 30 | Supply and fixing in replacement of thermoplastic polystyrene/ polycarbonate enclosure shock proof, IP 65 (weather proof) rust proof, dust proof, water proof, internally embedded gasket with provision for all side cable entry through gland (IP-65) and/ or gromments (IP-55) size of enclosure (250 x 180 x 110mm) with suitable connectors for three phase loop in loop out and branch out vibration proof connections with 16 Amp MCB SP and fixing on PCC/ Steel poles with 25 x 3 mm thick 02 Nos of clamp with nuts bolts and washers and proper thimbling complete all as specified and as directed. |
| 31 | Supply and fixing in replacement of thermoplastic polystyrene/ polycarbonate enclosure shock proof, IP 65 (weather proof) rust proof, dust proof, water proof, internally embedded gasket with provision for all side cable entry through gland (IP-65) and/ or gromments (IP-55) size of enclosure (250 x 180 x 110mm) with suitable connectors for single phase loop in loop out and branch out vibration proof connections with 16 Amp MCB SP and fixing on PCC/ Steel poles with 25 x 3 mm thick 02 Nos of clamp with nuts bolts and washers and proper thimbling complete all as specified and as directed. |
| 32 | Material and labour in replacement of PVC insulated and sheathed cable of size 1.5 Sqmm 3 core copper conductor multistranded 1100 Volt grade 230 volts running through PVC conduit of dia 20 mm with strip clamping complete for security light to junction box complete all as specified and as directed by Engineer-in-Charge. |
| 33 | Material and labour for preparation of old painted/ rusted surfaces of steel tubular poles 11/9 mtrs long type 410 SP-31, 55 and applying one coat of synthetic enamel paint upto 1.2 mtr height in black and white strip of width 30cm each as per exising pattern above the P.C.C coping and two coats of aluminum paint (1st quality) beyond 1.2 mtr height (for the rest of portion) including cross arms and channel, angle fitted on the pole including writing pole numbers and cutting vegetation growth all around and on the poles upto 1 mtr radius complete all as specified and as directed. |
| 34 | Material and labour in replacement of unserviceable street light bracket made out of GI pipe 1.2 mtr long 40mm dia medium grade bent to shape as directed including MS clamps made out of 25mm x 3mm flat iron for fixing bracket suitable for PCC/ street poles including nuts and bolts of required size including painting with one coat of aluminium paint over a coat of red oxide/ primer complete all as specified and as directed including taking down of old unserviceable bracket. |
| 35 | Material and labour in replacement of unserviceable street light bracket made out of GI pipe 1.2 mtr long 25mm dia medium grade bent to shape as directed including MS clamps made out of 25mm x 3mm flat iron for fixing bracket suitable for PCC/ street poles including nuts and bolts of required size including painting with one coat of aluminium paint over a coat of red oxide/ primer complete all as specified and as directed including taking down of old unserviceable bracket. |
| 36 | Supply and fixing in replacement of automatic street light switch using Nature Switch for automatic switching of street lights based on LUX level of natural light the sensor (nature switch) along with suitable power contactors and MCBs (Input-output) should be enclosed in pole/ wall mountable enclosure made of rust proof, Electric shock proof, termite proof and FR grade SMC junction box (sintex make) conforming to IP-54, the contactor, MCBs and copper circuit wiring (minimum 16 Sqmm) should enough to take: three-phase load of 12KW; contactor Rating 80Amps; MCB (SPN) Rating 80Amps complete all as specified and as directed.Makes: - Swadeep, Model No Swadeep-02EC12KW3P or equivalent in Legrands/ Siemens. |
| 37 | Supply and fixing in replacement of automatic street light switch using Nature Switch for automatic switching of street lights based on LUX level of natural light the sensor (nature switch) along with suitable power contactors and MCBs (Input-output) should be enclosed in pole/ wall mountable enclosure made of rust proof, Electric shock proof, termite proof and FR grade SMC junction box (sintex make) conforming to IP-54, the contactor, MCBs and copper circuit wiring (minimum 10 Sqmm) should enough to take: Single-phase load of 5KW; contactor Rating 40Amps; MCB (SP) Rating 40Amps complete all as specified and as directed.Makes: - Swadeep, Model No Swadeep-02EC5KW1P or equivalent in Legrands/ Siemens. |
| 38 | Road cutting, PCC hard standing as per site requirement including excavation for laying of GI pipe and making good the disturbed surfaces complete all as specified and as directed. |
| 39 | PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) as in foundation of electric poles, struts, PCC blocks etc including necessary form work complete all as specified and as directed. |
| 40 | PCC (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) as in foundation of assembly, bed concrete including necessary form work and fair finish to exposed surfaces without using extra cement, struts, PCC blocks etc including necessary form work complete all as specified and as directed. |
| 41 | PCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in coping of poles and similar work including necessary form work and fair finish to exposed surfaces without using extra cement complete all as specified and as directed. |
| 42 | Steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31 (9.0 meters long) including two coats of silver paint over one coat of red oxide paint complete with strip of black and white strips having 30 cm of width upto 1.5 mtr height from top of coping including taking down old/ broken PCC pole, keeping away from site complete all as specified and as directed by Engineer-in-Charge.Note: - Excavation, foundation concrete etc will be measured and paid separately. |
| 43 | Dismantling of ACSR conductors or disturbed span including line spacer and keeping serviceable materials in safe custody for reuse and unserviceable materials removing from the site(s) complete all as specified and as directed. |
| 44 | Supply and fixing in replacement of ACSR conductor of any size and type from over head HT/ LT poles including binding at site to insulator with suitable size of binding wire etc complete all as specified and as directed. |
| 45 | Fixing only by restraining, tightening of ACSR conductors of any size/ type on HT/LT poles including necessary new aluminium binding wire for fixing with insulator/ PVC sleeves for jumper etc as required complete all as specified and as directed.Note: - Serviceable ACSR conductors shall be obtained from Ser item No. 44.00 here-in-before. |
| 46 | Labour for rectification of fault related ACSR jumpers, insulators binding wire by removing old one and replacement with new wire binding or rejumber as required etc. complete all as specified and as directed.Note: - Material shall be measured and paid separately under supply only. |
| 47 | Material and labour in replacement of galvanised steel wire 4.0 mm dia for continuous earth wire and Cradles hexagonal/ rectangular shall be provided and securely fastened to each pole and connected with earth ordinarily and cradle guarding where required complete including dismantling existing GI wire complete all as specified and as directed. |
| 48 | Material and labour in replacement for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections i.e. M.S. channel or angle sections etc. including new nuts, bolts, washers as required dia/ length in size, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive one primer coat of red oxide, one under coat and one finishing coat of silver paint (1st quality) as required complete all as specified and as directed. |
| 49 | Supply and fixing in replacement of Stay assembly with accessories and GI stay rod 16 mm dia 1900 mm long, stay wire 7/4 mm stranded galvanised including mild steel stay plate 300 mm x 300 mm x 6 mm and galvanised thimble, galvanised steel 14 mm dia 400 mm long stay bow and GI nuts, washers including loop type insulator vitreous porcelain white, brown or green big size with overall dimensions 90 mm x 140 mm clearance of hole 25.5 mm complete all as specified and shown in electrical plate No 01 of SSR Part - I complete all as directed.Note: - Excavation, stay clamps and concrete work etc will be measured and paid separately. |
| 50 | Dismantling insulators, any type, any size and keeping serviceable materials in safe custody for re-use and/ or unserviceable materials removing from the site complete all as specified and as directed. |
| 51 | Insulator pin type, porcelain, vitreous, white, brown or green including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade complete all as specified and as directed. |
| 52 | Fixing only serviceable pin type porcelain, vitreous, (white/brown or green) insulator for 1100 volts grade of any type obtained from Ser item No 51.00 here-in-before complete all as specified and as directed. |
| 53 | Insulator Shackle type, porcelain, vitreous, white, brown or green, shall be in one piece and shall have a groove on the side and a hole for a cotter pin and two galvanised bolts 12 mm dia and nuts with or without a pair of straps in size 31 x 3 mm as indicated size height 75 mm and dia 90 mm, for working pressure 1100 volts complete all as specified and as directed. |
| 54 | Fixing only serviceable shackle type porcelain, vitreous (white / brown or green) insulator of any size and shape for 1100 Volts grade obtained from Ser item No 53.00 here-in-before complete all as specified and as directed. |
| 55 | Earthing complete with galvanised mild steel earth plate electrode of size 600 x 600 x 6mm thick burried directly in ground earth (in vertical) earth pit not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr below ground level connected to galvanised iron or earth lead wire 4mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised iron including PCC pit in PCC (1:2:4) type B-1 pre-cast RCC cover slab using reinforcement with suitable handle made of round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and including dismantling and taking down old unserviceable complete all as specified and as directed. |
| 56 | PVC flat fibre separator for LT line 1100 volt overhead conductor 3/4/5 wire system for maintaining horizontal spacing of conductor complete with nut and bolt in a span complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 20, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysSep 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender