Defence Statutory Bodies & Commissions/Committees Closing in 6 days TDR #57122273

Tender For Repair/Maintenance Of Geysers And Summer Appliances Incl Mechanical Laundry Under Ge Missamari

Issued by Statutory Bodies & Commissions/Committees · Sonitpur, Assam
Tender Value
Ref. Documents
Estimated cost
Bid Submission
03 Sep 2026
6 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Sonitpur → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Maintenance Of Geysers And Summer Appliances Incl Mechanical Laundry Under Ge Missamari

BOQ

Name of Work:- REPAIR/MAINTENANCE OF GEYSERS AND SUMMER APPLIANCES INCL MECHANICAL LAUNDRY UNDER GE MISSAMARI
Sl. No. Item Description
1Taking down existing unserviceable geysers of any type and any capacity from wall and re-installation at any location including fixing with and including heavy duty pin type fastener 4 inch long and making necessary inlet/outlet water supply connections from existing source to geyser complete all as specified and as directed.
2M&L surface point wiring for One socket outlet 15 Amps point on independent board point controlled by one way switch 15/16 amps complete with 2.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC casing capping medium grade with accessories (ISI marked) fixed in wall/fixed to roof, ceiling etc including provision of 2.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated suken terminal box made out of MS sheet steel not less than 1.22 mm thick for boxes duly painted with aluminum inside and anticorrosive paint outside,(clear depth of the box not less than 60mm and this shall be increased suitably to accomadiate flush type regulators) concealed in walls, with 3mm thick bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed complete all as specified and as directed.Notes:-(i) Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles.
3M&L surface point wiring for One socket outlet 15 Amps point on independent board point controlled by one way switch 15/16 amps complete with 4.00Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC casing capping medium grade with accessories (ISI marked) fixed in wall/fixed to roof, ceiling etc including provision of 4.00 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated suken terminal box made out of MS sheet steel not less than 1.22 mm thick for boxes duly painted with aluminum inside and anticorrosive paint outside,(clear depth of the box not less than 60mm and this shall be increased suitably to accomadiate flush type regulators) concealed in walls, with 3mm thick bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed complete all as specified and as directed.Notes:-(i) Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles.
4Inspection,checking adjustments and repairs of storage water heater 25/35/50 ltr capacity of any type any make vertical/ horizontal type which includes the following :-(a) Inspection, taking out of drain plug & dewatering and refixing the same complete all as directed .(b) Checking water tightness of storage tank . (c) Checking stop cocks with outlet/inlet pipe of geysers, pressure reducing valves etc to ensure free movement of water and easy functioning of parts.(d) Inspecting over flow vent pipe connections to ensure water-tightness and proper flow.(e) Checking and correct earth continuity of electrical items.(f) Checking functioning of heating element and correct setting adjustment of thermostat upto 55º C.(g) Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness. (h) The cost of spare parts required for repair & mainenance of geysers covered under this item shall be measured and paid separately under the relevant item as supply only.
5Supply only heating element, Round type / tikona type / banana type, 1.5 KW 230 volts, ISI marked suitable for 25/35/50 ltrs geysers of complete all as specified and as directed
6Supply only heating element, Round type / tikona type / banana type, 2 KW 230 volts, ISI marked suitable for 25/35/50 ltrs geysers complete all as specified and as directed
7Supply only thermostat switch for geysers of 25/50 ltrs capacity (ISI marked) complete all as specified and as directed.
8Supply only glass wool for geysers complete all as specified and as directed.
9Supply only base assembly, compatible to existing geyser, with inlet and thermostat pipe with drain plug inclusive of clamps for holding the element with nuts, bolts and gasket complete all as specified and as directed.
10Supply only indicator lamp for geyser of any type colour green & red complete all as specified and as directed.
11Supply only copper inner tank of minimum 22 gauge sheet rated pressure not less than 7kg/sqcm suitable for 25/35 ltrs capacity geysers (weight not less than 3.75 kg) complete all as specified and as directed.
12Supply only of Copper inner tank of minimum 22 gauge sheet rated pressure not less than 7 Kg/sqcm suitable for 50 ltrs capacity geysers (weight not less than 5.25 kg) complete all as specified and as directed.
13Supply only outer body of MS sheet not less than 22 gauge suitable for 25/35 ltr geyser with white synthetic enameled paints complete all as specified and as directed.
14Supply only outer body of MS sheet not less than 22 gauge suitable for 50 ltr geyser with white synthetic enameled paint complete all as specified and as directed.
15Supply only plug top 3 pin 15 Amp ISI marked complete all as specified and as directed.
16Supply only bottom cover of PVC suitable for 25/35 ltrs capacity geysers complete all as specified and as directed
17Supply only bottom cover of PVC suitable for 50 ltrs capacity geysers complete all as specified and as directed.
18S&F in repair, 15mm bore Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, chromium plated fancy type, screwed both ends for iron pipe or for union, ISI marked, complete all as specified and as directed.
19S&F in repair, 15mm bore Bib taps, cast copper alloy, with crutch or butterfly handle, chromium plated, fancy type, screwed down, screwed for ISI marked, complete all as specified and as directed.
20S&F Switch piano flush type, single pole, one way, 15 Amp fixed as in repair complete all as specified and as directed.
21S&F shuttered socket out let, 3 Pin, 15 Amp, 230 volts piano flush type fixed as in repair complete all as specified and as directed.
22S&F in repair, Stainless steel connection for hot/ cold water made of double layer nylon braided and fabric at a pressure of 6kg/sq cm at both ends, 450 mm long, heavy duty with CP brass adopters, washers, suitable for 15 mm bore pipe, complete all as specified and as directed.
23S&F in repair, stainless steel connection for hot/ cold water made of double layer nylon braided and fabric at a pressure of 6kg/sq cm at both ends, 600 mm long, heavy duty with CP brass adopters, washers, suitable for 15 mm bore pipe complete all as specified and as directed.
24S&F in repair, 3 core PVC insulated copper cable of size 2.5 Sqmm multi stranded fixed as in repair complete all as specified and as directed.
25S&F Modular Switch piano flush type, single pole, one module, 16/20 Amp complete all as specified and as directed.
26S&F Modular shuttered socket out let, 2/3 Pin, 6/16 Amp, 230 volts two module, complete all as specified and as directed.
27Supply and laying in floor, fixed to walls and ceiling, 25mm bore galvanised steel tubing medium grade, ISI marked, including fittings including taking down existing unserviceable pipe, making good to floor, wall and ceiling as per existing complete all as specified and as directed.
28Supply and laying in floor, fixed to walls and ceiling, 20 mm bore galvanised steel tubing medium grade, ISI marked, including fittings including taking down existing unserviceable pipe, making good to floor, wall and ceiling as per existing complete all as specified and as directed.
29Supply and laying in floor, fixed to walls and ceiling, 15 mm bore galvanised steel tubing medium grade, ISI marked, including fittings including taking down existing unserviceable pipe, making good to floor, wall and ceiling as per existing complete all as specified and as directed.
30M&L for Cutting and screwing existing steel tubing of 15/20/25mm bore for alterations or additions (Each cut measured) required for connections to gysers complete all as specified and as directed
31M&L Painting of outer surface of 25/35/50 ltrs storage type water geysers after cleaning of dust & other organic/inorganic materials if any and applying one coat of synthetic enamel white paint by spray painting and writing MES No on the geyser complete all as specified and as directed.
32S&F in repair, Instant hot water heating element for any capacity complete all as specified and as directed.
33Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. seperating serviceable fittings/fixtures, keeping in safe custody reuse under respective item and removal of unserviceable material from site and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed.Note:- Concealed conduit in RCC slab/beam shall not be not be taken out
34Dismantling carefully solar storage water heating system of any capacity, any type for following works with testing and refixing the same in original position making all water/ electric connection to entire satisfaction of Engineer-in-charge after carrying out necessary repair as under :-(a) Inspection, opening, of all parts, descaling, washing of inner tank with chemical solution and cleaning of outer cover storage tank.(b) Checking water tightness of storage tank after cleaning.(c) Checking and correcting earth continuity of electrical items.(d) Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness. Note : Supply and fixing of Spare parts. wiring etc shall be measured & paid separately.
35Supply only Heating element, 3.00 KW 230 volts, ISI marked suitable for solar geyers tank, complete all as specified and as directed.
36Supply only thermostat switch for solar water heater (ISI marked), complete all as specified and as directed.
37Repair and welding to copper water storage tank of solar storage water heating systme of any capacity 100 to 500 LPD, to prevent any type of leakage at site with testing and refixing the same in original position makig all water / electric connection to entire satisfication of Engineer-in Charge after necessary repair as under:-(a) Inspection, opening, of all parts, descaling, washing of inner tank with chemical solution and cleaning of outer cover storage tank.(b) Checking water tightness of storage tank after cleaning.(c) Checking and correcting earth continuity of electrical items.(d) Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness. Note : Supply and fixing of Spare parts. wiring etc shall be measured & paid separately.
38M&L sub-main wiring alongwith earth wire of size of 2 x 4.0 sq. mm + 1 x 4.0 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through existing conduit/PVC casing capping, and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE : (i)Two runs of 4sqmm PVC wire, one run of 4Sqmm earth wire will be measured as one length. (ii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED
39S&F in repair, Glass collector suitable for solar water heating system of any size complete all as specified and as directed.
40M&L in repair, Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of Capacity 20 Amps complete all as specified and directed.
41S&F in repair, MCB, SPN, C Series 240 Volts, 6-32 Amps 50 HZ, 10KA complete all as specified and as directed.
42S&F in repair, MCB, SP, C Series 240 Volts, 6-32 Amps 50 HZ, 10KA complete all as specified and as directed.
43S&F in repair, AC metal plug top with metal socket siutable for 20 Amps 3 Pin including necessary aconnections complete all as specified and directed.
44S&F in repair 25x16mm, medium grade, PVC casing and capping of 10 foot length in repairs duly fixed with casing pins and connecting accessories like Tee , Bends , elbow etc required as per site complete all as direced.
45S&F in repair 25mm dia medium grade PVC Conduit of 10 foot length in repairs duly fixed with Clamps on wall surfaces and connecting accessories like Tee , Bends , elbow etc required as per site complete all as direced.
46S&F in repair PVC square box 100mm x 100mm including refixing of old switch socket complete all as specified and as directed.
47S&F in repair PVC square box 170mm x 100mm including refixing of old switch socket complete all as specified and as directed.
48S&F in repair PVC square box 200mm x 150mm including refixing of old switch socket complete all as specified and as directed.
49S&F in repair, ceiling fan capacitor 2.5 mfd as per site requirement heavy duty with metal body complete all as specified and directed.
50S&F in repair, ceiling fan capacitor 3.15 mfd as per site requirement heavy duty with metal body complete all as specified and directed.
51S&F in repair, ceiling fan capacitor 4 mfd as per site requirement heavy duty with metal body complete all as specified and directed.
52Disconnecting and taking down Ceiling Fan/Wall Mounted/Exhaust Fan/Air Circulator of any Sweep by Electrical Connections, cleaning Internally and Externally thoroughly, replacement of Split Pins, Cotter Pins and Check-nuts, etc. overhauling, lubricating with approved Lubricants, re-assembling including , re-fixing in Original Position checking smooth functioning and including electrically connected with Flexible Wire multi -stranded Copper Conductor Cable of size 23/0.0076 from Ceiling Rose to Fan cleaning all dust, etc. after repair duly painted two coats as per existing colour over a coat of primer and testing complete all as specified and as directed.
53M&L rewinding Ceiling Fan 1200/1400mm Sweep of any Make and type with Super Enameled Copper Winding Wire as per existing size and gauge including heating, varnishing complete and replacement of unserviceable/ wornout Points for statisfactory running and testing, complete all as specified and as directed.
54S&F Ball Bearing No. 6201(as approved) suitable for ceiling fans complete all as specified and directed.
55Supply and fixing Gun Metal Bush (as approved) suitable for ceiling fans 1200/1400 mm sweep complete all as specified and directed.
56M&L rewinding Exhaust Fan 300 mm Sweep of any Make and type with Super Ena-meled Copper Winding Wire as per existing size and gauge including heating, varnishing complete and replacement of unserviceable/ wornout Points for statisfactory running and testing, complete all as specified and as directed.
57Supply and fixing Ball Bearing (as approved) suitable for Exhaust fans 30mm sweep complete all as specified and directed.
58Supply and fixing Gun Metal Bush (as approved) suitable for Exhaust fans 300 mm sweep complete all as specified and directed.
59M&L rewinding Exhaust Fan 380/450 mm Sweep of any Make and type with Super Enameled Copper Winding Wire as per existing size and gauge including heating, varnishing complete and replacement of unserviceable/ wornout Points for statisfactory running and testing, complete all as specified and as directed.
60Supply and fixing Ball Bearing (as approved) suitable for Exhaust fans 380mm/450mm sweep complete all as specified and directed.
61Supply and fixing Gun Metal Bush (as approved) suitable for Exhaust fans 380/450 mm sweep complete all as specified and directed.
62M&L rewinding Air circulator Fan 450/600mm Sweep of any Make and type with Super Enameled Copper Winding Wire as per existing size and gauge including heating, varnishing complete and replacement of unserviceable/ wornout Points for statisfactory running and testing, complete all as specified and as directed.
63Supply and fixing Ball Bearing (as approved) suitable for Air circulator Fan 450/600mm Sweep complete all as specified and directed.
64Supply and fixing Gun Metal Bush (as approved) suitable forAir circulator Fan 450/600mm Sweep complete all as specified and directed.
65Taking down the existing unserviceable main switch/ cut out/ DBs of any type/ capacity/ description including making good the disturbed surfaces to match with the existing finishes complete all as specified and directed.
66Taking down the existing unservicable sub main wiring of any type / description as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as directed.
67S&F in repair, armature core of ceiling fan 1200mm sweep as per site requirement complete all as specified and directed.
68S&F in repair, armature core of Exhaust fan 300mm sweep as per site requirement complete all as specified and directed.
69S&F in repair, armature core of Exhaust fan 380mm/450mm sweep as per site requirement complete all as specified and directed.
70S&F in repair, PVC fan blade of exhaust fan 200mm sweep as per existing complete all as specified and directed.
71S&F in repair, blower motor of PVC sturdy plastic fan 200mm sweep as per existing complete all as specified and directed.
72S&F in repair, PVC fan blade of exhaust fan 250mm sweep as per existing complete all as specified and directed.
73S&F in repair, blower motor of PVC sturdy plastic fan 250mm sweep as per existing complete all as specified and directed.
74S&F in repair, PCB of BLDC Ceiling fan 1200mm sweep as per existing complete all as specified and directed.
75Supply only remote of BLDC ceiling fan 1200mm sweep as per existing complete all as specified and directed.
76S&F CI fan hook of shape and size as per site requirement fixed in ceiling and making good the the distrubed surfaces complete all as specified and directed.
77S&F in repair, Clamps for hanging of ceiling fan with rubber nuts, bolts etc as required complete all as specified and directed.
78S&F in repair, 1100 Volts grade PVC insulated stranded flexible copper conductor twin core 1.00 sqmm and connecting from ceiling rose to terminal block of fan complete all as specified and directed.
79Taking down for servicing of split type AC 1.5TR Capacity including cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors, fan motor etc,(Out door unit) with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit including PCB, fan, blower, etc., changing electrical connections if required and keeping the AC unit in satisfactory working condition after necessary servicing and refixing the same in existing position complete all specified and as directed NOTE :(i) Compressor, Refrigerent gas and other Spares Parts wherever required will be Measured and Paid separately under respective Items.(ii) QUOTED UNIT RATE shall also deemed to be included for any Minor Parts such as Capilary Tube, Machine Screw, Washer, Rubber Bush, etc. required for proper setting of Machine.
80Repairs/Servicing Air Conditioner 2.0 Ton Capacity, Window type at Site of any Make and any type by replacing unserviceable Parts (like Compressor and other Minor Parts viz Capilary Tube, Machine Screws, Washer, Rubber Bush, etc) from the Machine including Charging of Refrigerant Gas after vacuuming and leak testing, brazing the suction/discharge tubes where required and cleaning of Condensing Unit to achieve proper Cooling effect, checking of Electrical Circuit of machine and repair where necessary by replacing proper size PVC insulated Wires and cleaning of AC using air blower as directed, commissioning & Testing, complete all as specified and directed.NOTE :(i) Compressor, Refrigerent gas and other Spares Parts wherever required will be Measured and Paid separately under respective Items.(ii) QUOTED UNIT RATE shall also deemed to be included for any Minor Parts such as Capilary Tube, Machine Screw, Washer, Rubber Bush, etc. required for proper setting of Machine.
81Taking down for servicing of Window type AC 1.5TR Capacity including cleaning of cooling coil, air filters, condenser, compressors, fan motor etc with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, remote control unit including PCB, fan, blower, etc, changing electrical connections and keeping the AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing position complete all specified and as directed NOTE :(i) Compressor, Refrigerent gas and other Spares Parts wherever required will be Measured and Paid separately under respective Items.(ii) QUOTED UNIT RATE shall also deemed to be included for any Minor Parts such as Capilary Tube, Machine Screw, Washer, Rubber Bush, etc. required for proper setting of Machine.
82Taking down for servicing of Window type AC 2.0 TR Capacity including cleaning of cooling coil, air filters,condenser, compressors, fan motor etc with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, remote control unit including PCB, fan, blower, etc, changing electrical connections and keeping the AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing position complete all specified and as directed NOTE :(i) Compressor, Refrigerent gas and other Spares Parts wherever required will be Measured and Paid separately under respective Items.(ii) QUOTED UNIT RATE shall also deemed to be included for any Minor Parts such as Capilary Tube, Machine Screw, Washer, Rubber Bush, etc. required for proper setting of Machine.
83S&F in repair, starting relay for 1.5 TR compressor all as specified and directed.
84S&F in repair, starting relay for 2 TR compressor all as specified and directed.
85S&F in repair, over load protector for 1.5 TR compressor all as specified and directed.
86S&F in repair, over load protector for 2TR compressor all as specified and directed.
87S&F in repair, Thermostate switch for 1.5 TR split/window type AC all as specified and directed.
88S&F in repair, Thermostate switch for 2 TR split/Window type AC all as specified and directed.
89S&F in repair, of Starting capacitor 80-100 Mfd capacity in metal container all as specified and directed.
90S&F in repair, of Starting capacitor 120-150 Mfd capacity in metal container all as specified and directed.
91S&F in repair, of running capacitor 36 Mfd capacity in metal container pin type all as specified and directed.
92S&F in repair, of running capacitor 50±4 Mfd capacity in metal container pin type all as specified and directed.
93S&F in repair, of running capacitor 50±6 Mfd capacity in metal container pin type all as specified and directed.
94S&F in repair, Running capacitor 10 mfd metal body pin type complete all as specified and directed
95S&F in repair, Running capacitor 6 mfd metal body pin type complete all as specified and directed
96S&F in repair, Running capacitor 4 mfd metal body pin type complete all as specified and directed
97S&F in repair, Running capacitor 2.5 mfd metal body pin type complete all as specified and directed
98S&F in repair, suction copper pipe line heavy duty 1/2'' dia and flair nuts from indoor to outdoor unit of split AC 1.5 /2 TR capacity all as specified and directed.
99S&F in repair, discharge copper pipe line heavy duty 1/4\\" dia and flair nuts from indoor to outdoor unit of split AC 1.5 TR /2 TR capacity all as specified and directed.
100S&F in repair, discharge copper pipe line heavy duty 5/8\\" dia and flair nuts from indoor to outdoor unit of split AC 1.5 TR /2 TR capacity all as specified and directed.
101S&F in repair, discharge copper pipe line heavy duty 3/8\\" dia and flair nuts from indoor to outdoor unit of split AC 1.5 TR /2 TR capacity all as specified and directed.
102S&F in repair, discharge copper pipe line heavy duty 3/4\\" dia and flair nuts from indoor to outdoor unit of split AC 1.5 TR /2 TR capacity all as specified and directed.
103S&F in repair, PVC pipe nylon imbraided 15 mm dia for condenser water drain fitted with clamps/ concealed in wall all as specified and directed.
104S&F Foam insulation for copper tubing of size 1/2'' dia complete all as specifed and directed.
105S&F Foam insulation for copper tubing of size 5/8'' dia complete all as specifed and directed.
106S&F Foam insulation for copper tubing of size 1/4'' dia complete all as specifed and directed.
107S&F Foam insulation for copper tubing of size 3/8'' dia complete all as specifed and directed.
108S&F Foam insulation for copper tubing of size 3/4'' dia complete all as specifed and directed.
109S&F in repair, condensing copper coil unit of split type AC of 1.5 TR capacity complete all as specified and directed.
110S&F in repair, condensing copper coil unit of split type AC of 2 TR capacity complete all as specified and directed.
111S&F in repair, blower motor of 1.5 TR split AC (indoor unit) of existing manufacturer of AC. Make of AC Carrier/Voltas /Blue star complete all as specified and directed.
112S&F in repair, blower motor of 2 TR split AC (indoor unit) of existing manufacturer of AC. Make of AC Carrier/Voltas /Blue star/LG/Samsung complete all as specified and directed.
113Dismantling of burnt condensor motor of 1.5 TR split AC (Outdoor unit) and rewinding & refixing condensor motor at same position including replacement of bearing bushing, complete all as specified and as directed.
114Dismantling of burnt condensor motor of 2 TR split AC (Outdoor unit) and rewinding & refixing condensor motor at same position including replacement of bearing bushing, complete all as specified and as directed.
115Dismantling of burnt swing motor of 1.5 TR split AC (indoor unit) and supply & fixing swing motor of same manufacturer of AC, complete all as specified and directed.
116Dismantling of burnt swing motor of 2 TR split AC (indoor unit) and supply & fixing swing motor of same manufacturer of AC, complete all as specified and as directed.
117Supply and charging (Top up) the AC unit of 1.5 TR /2 TR split type AC unit with Refrigerant Gas compatible to R-22 type in required quatity complete all as specified and directed.
118Supply and charging (Top up) the AC unit of 1.5 TR /2 TR split type AC unit with Refrigerant Gas compatible to R-134 type in required quatity complete all as specified and directed.
119Supply and charging (Top up) the AC unit of 1.5 TR /2 TR split type AC unit with Refrigerant Gas compatible to R-410 type in required quatity complete all as specified and directed.
120Supply and charging (Top up) the AC unit of 1.5 TR /2 TR split type AC unit with Refrigerant Gas compatible to R-32 type in required quatity complete all as specified and directed.
121Supply and charging the AC unit of 1.5/2/2.5/3.5/4.5 TR split type AC unit with Nitrogen Gas for detecting of leakages required as per site quatity complete all as specified and directed.
122Supply and fixed in repairs of suction valve size 1/2\\" complete all as specified and directed .
123Supply and fixed in repairs of discharge valve size 1/4\\" complete all as specified and directed.
124Supply and fixed in repairs of suction valve size 5/8\\" complete all as specified and directed .
125Supply and fixed in repairs of discharge valve size 3/8\\" complete all as specified and directed.
126Dismantling of un-serviceable cooling coil unit any type any size of indoor unit of split type Air Conditioner of capacity 1.5 TR by cutting the suction line and discharge line, and providing new cooling copper coil unit of indoor unit (of same capacity), including testing on completion complete all as directed
127Dismantling of un-serviceable cooling coil any type any size of indoor unit of split type Air Conditioner of capacity 2.0 TR by cutting the suction line and discharge line, and providing new cooling copper coil of indoor unit (of same capacity),including testing on completion complete all as directed
128M&L for carrying out pressure leak test of split ACs 1.5 / 2.0 TR capacities by Nitrogen gas pressure for detecting leak in cooling unit refrigerant pipe and repairing the leak by welding or brazing of cooling unit and refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe including gas charging transporting & carrying out Tools and Plant required at site complete all as specified and directed. Note : Cost of Nitrogen gas will be paid under respective schedule
129M&L for carrying out pressure leak test of split ACs 2.0 TR capacities by Nitrogen gas pressure for detecting leak in cooling unit refrigerant pipe and repairing the leak by welding or brazing of cooling unit and refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe including gas charging transporting & carrying out Tools and Plant required at site complete all as specified and directed. Note : Cost of Nitrogen gas will be paid under respective schedule
130M&L carrying out pressure leak test of 1.5 TR window AC by Nitrogen gas pressure for detecting leak in cooling unit refrigerant pipe and repairing the leak by welding or brazing of cooling unit and refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe including gas charging transporting & carrying out Tools and Plant required at site complete all as specified and directed. Note : Cost of Nitrogen gas will be paid under respective schedule
131M&L carrying out pressure leak test of 2.0 TR window AC by Nitrogen gas pressure for detecting leak in cooling unit refrigerant pipe and repairing the leak by welding or brazing of cooling unit and refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe including gas charging transporting & carrying out Tools and Plant required at site complete all as specified and directed. Note : Cost of Nitrogen gas will be paid under respective schedule
132Dismantling of defective worn out wiring of indoor unit of split AC of capacity 1.5 TR including unserviceable cordless electronic remote control, supply and fixing PCB (Printed circuit Board) & Visual Eye demo plate to suit /match the existing system complete all as specified and directed.
133Dismantling of defective worn out wiring of indoor unit of split AC of capacity 2 TR including unserviceable cordless electronic remote control, supply and fixing PCB (Printed circuit Board) & Visual Eye demo plate to suit /match the existing system complete all as specified and directed.
134Supply and fixing in repairs front grill for window AC of 1.5 TR /2TR of existing make complete all as specified and directed.
135S&F PVC insulated and PVC round sheathed copper conductor (flexible) industrial cable, (FRLS) 1100 Volts, conforming to IS 694 of size 2.5 sqmm 3 Core connecting electrical equipments with terminal lugs / clips as per site requirement, complete all as specified and as directed.
136S&F Bottom tray of 1.5 ton /2 ton capacity window type AC made out of 14 SWG mild steel sheet Including painting with two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
137Taking out existing out door unit of split type Air Conditioner including refrigerant lines and electrical connections (of capacity 1.5 TR / 2.0 TR) and re-fixing at new location as directed alongwith fixing arrangement with nuts and bolts complete all as directed (Note :- Excess requirement of refrigerant pipe line, AC outdoor metalic stand ,electric connection cable, drain pipe topping up of refrigerant gas shall be measured and paid separately under relevant item of this schedule)
138Taking out existing indoor unit of split type Air Conditioner including refrigerant lines and electrical connections of capacity 1.5 TR / 2.0 TR) and re-fixing at new location alongwith fixing arrangement with screwed on wooden gutka on wall surface and making good the disturbed surfaces complete all as directed (Note :- Excess requirement of refrigerant pipe line, electric connection cable ,drain pipe and topping up of refrigerant gas to be measured and paid separately under relevant item of this schedule)
139S&F Compressor sealed unit for Split type Air Conditioner of capacity 1.5 ton reciprocating compressor by removing of old burnt compressor and fixing as per manufacturer instruction including providing connections of gas line, fixing of copper tubes of suitable sizes, hand shut off valves, relays, starting and running capacitors etc. complete all as specified and as directed.Note :- Charging of gas refrigerant will be paid and measured separately
140All as per item No 139 here in before but 2 TR capacity reciprocating compressor
141All as per item No 139 here in before but 1.5 TR capacity rotary type compressor
142All as per item No 139 here in before but 2 TR capacity rotary compressor
143Taking down indoor unit of 1.5 TR capacity by preserving the existing gas in outdoor unit, checking and overhauling the complete indoor unit part by part and refixing at same position including testing complete all as directed (Note:-The repair of indoor motor, filters and roller runner to be measured and paid separately under relevant item )
144Taking down indoor unit of 2.0 TR capacity by preserving the existing gas in outdoor unit, checking and overhauling the complete indoor unit part by part and refixing at same position including testing complete all as directed (Note:-The repair of indoor motor, filters and roller runner to be measured and paid separately under relevant item )
145S&F in replacement of AC Outdoor metallic stand for fixing out door unit complete all as specified and as directed.
146Taking down unserviceable blower motor base (2mm thick Mild Steel Sheet) of 1.5 TR/2TR capacity split AC and supply and fixing new blower motor base by welding / fixing by nut and bolt refixing the blower motor after completing the base and aligning the motor complete as directed
147S&F Compressor sealed unit of Window type Air Conditioner of capacity 1.5 TR reciprocating type by removing of old burnt compressor and fixing as per manufacturer instruction including providing connections of gas line, fixing of copper tubes of suitable sizes complete all as directed
148All as per item No 147 here in before but 2.0 TR capacity reciprocating compressor.
149All as per item No 147 here in before but 1.5 TR capacity rotary type .
150All as per item No 147 here in before but 2.0 TR capacity rotary compressor.
151S&F Cooling coil condenser unit of Window type Air Conditioner of capacity 1.5/2.0 TR including providing connections and fixing in proper position including taking down old unserviceable one complete all as directed
152Taking down window type Air Conditioner, shifting and installation of same at other location within two Km radius including cutting and opening of existing brick work and making good dismantled portion in cement mortar 1:3 as required ( exc. Half Brick but not exc. one brick thick Walls) and finishing the surfaces as per existing finishes, removing debries from the site complete all as specified and as directed.
153M&L Cutting openings, through brick wall (one brick thick) for fixing of window type Air Conditioner, providing second class hard wood frame (sectional size not less than 50mmx50mm),providing 2 coats of syntheic enamel paint over a coat of primer, on wooden frame, size as per AC model including fair finish of side walls in cement mortar (1:6) and finishing the surfaces as per existing finishes, removing debries from the site complete all as specified and as directed.
154Supply and fix power contactor 3 pole, coil voltage 415 Volts of capacity32 Amps Complete all as specified and as directed.
155Supply and fix remote control hand set make suitable for 2.0TR capacity window type AC complete all as specified and as directed.
156Supply and fix remote control hand set suitable for 1.5 TR capacity window type AC complete all as specified and as directed.
157Dismantling of defective refrigerator of any make and capacity including transportation to workshop and back for thorough checking of all accessories and components, repairs and reassembling the same after repair/replacement of defective accessories/components and testing complete all as directed
158Supply & Fix PCB with Wiring set complete consisting of PVC insulated flexible wire with stranded copper conductor of size 1.5 sqmm and fixing clips for refrigerator all types complete all as specified and directed
159Supply & Fix Bimetal 2 wire/3wire /4 wire complete all as specified and directed
160Supply & Fix Forst free fan motor SP 230 volts complete all as specified and directed
161Supply & Fix Sensor for cooling coil complete all as specified and directed
162Supply & Fix PCB timer of refrigerator 180-310ltrs required as per site complete all as specified and directed
163Supply & Fix Condenser coil for 165 to 200 Ltrs complete all as specified and directed
164Supply & Fix Condenser coil for 250 to 310 Ltrs complete all as specified and directed
165S&F of heating coil including fixing accessories suitable for 250/286/310 ltrs complete all as specified and directed
166Taking out burnt compressor after disconnecting suction and discharge line and supply and fixing new compressor as per existing including testing complete all as specified and directed for Regrigerator of Capaicty 165/180 Ltrs complete all as specified and directed Note:-Re- Charging of gas will be measured and paid separetely
167Taking out burnt compressor after disconnecting suction and discharge line and supply and fixing new compressor as per existing including testing complete all as specified and directed for Refrigerator of Capaicty 285/310 Ltrs complete all as specified and directed Note:-Re- Charging of gas will be measured and paid separetely
168Dismantling of defective water cooler storage type of 40/80/120/150 ltrs capacity including transportation to workshop and back for thorough checking/including all accessories and components re-assembling the same after repair/ replacement of defective accessories/components including testing complete all as specified and directed.
169Supply & Fix PCB and Wiring set complete consisting of PVC insulated cable wiring stranded copper conductor connecting clips etc suitable for water cooler 40/80/120/150 ltrs complete all as specified and directed.
170Supply & Fix Thermostat including plastic regulating knob as per existing for water cooler of cooling capacity 40/80/120/150 ltrs complete all as specified and directed.
171Supply & Fix new compressor suitable for 40/80 ltr/hrs storage capacity including testing complete all as specified and directed. Note:-(Recharging of gas will be measured and paid separately).
172Taking out old burnt Condenser fan motor and supply and fixing of new blower motor and testing suitable for water cooler any make or type complete all as specified and directed.
173Dismantling of defective deep freezer including transportation to workshop and back of any capacity, size and type for thorough checking of all accessories and components re-assembling the same after repair/ replacement of defective accessories/components including testing complete all as specified and directed
174Supply & Fix new deep freedge compressor for storage capacity of 400 ltrs deep freezer including testing all as specified and directed . Note:-(Recharging of gas will be measured and paid separately).
175Supply & Fix new deep freedge compressor for storage capacity of 500 ltrs deep freezer including testing all as specified and directed.Note:- (Recharging of gas will be measured and paid separately).
176Supply & Fix Relay for deep freezer of any size/capacity complete all as specified and directed
177Supply & Fix Overload for compressor of deep freezer of any size/capacity complete all as specified and directed
178Supply & Fix Thermostate for deep freezer complete al as specified and directed
179Supply & Fix 4\\" condenser fan motor 240 volt complete all as specified and directed
180Dismantling of defective worn out wiring of Outdoor unit of split AC of capacity 1.5 TR inverter type including unserviceable cordless electronic remote control, supply and fixing PCB (Printed circuit Board) & Visual Eye demo plate to suit /match the existing system complete all as specified and directed.
181Dismantling of defective worn out wiring of Indoor unit of split AC of capacity 1.5 TR inverter type including unserviceable cordless electronic remote control, supply and fixing PCB (Printed circuit Board) & Visual Eye demo plate to suit /match the existing system complete all as specified and directed.
182Dismantling of defective worn out wiring of Outdoor unit of split AC of capacity 2.0 TR inverter type including unserviceable cordless electronic remote control, supply and fixing PCB (Printed circuit Board) & Visual Eye demo plate to suit /match the existing system complete all as specified and directed.
183Dismantling of defective worn out wiring of Indoor unit of split AC of capacity 2.0 TR inverter type including unserviceable cordless electronic remote control, supply and fixing PCB (Printed circuit Board) & Visual Eye demo plate to suit /match the existing system complete all as specified and directed.
184Taking down unserviceable inverter Outdoor Condensor motor of 1.5 TR capacity split AC and supply and fixing new inverter blower motor and aligning the motor complete all as directed
185Taking down unserviceable inverter indoor blower motor of 1.5 TR capacity split AC and supply and fixing new inverter blower motor and aligning the motor complete all as directed
186Taking down unserviceable inverter Outdoor Condensor motor of 2.0 TR capacity split AC and supply and fixing new inverter blower motor and aligning the motor complete all as directed
187Taking down unserviceable inverter indoor blower motor of 2.0 TR capacity split AC and supply and fixing new inverter blower motor and aligning the motor complete all as directed
188Taking down unserviceable inverter compressor and S&F Compressor sealed unit for Inverter Split type Air Conditioner of capacity 1.5 ton inverter compressor by removing of old burnt compressor and fixing as per manufacturer instruction including providing connections of gas line, fixing of copper tubes of suitable sizes, hand shut off valves, relays, starting and running capacitors etc. complete all as directed
189Taking down unserviceable inverter compressor and S&F Compressor sealed unit for Inverter Split type Air Conditioner of capacity 2.0 ton inverter compressor by removing of old burnt compressor and fixing as per manufacturer instruction including providing connections of gas line, fixing of copper tubes of suitable sizes, hand shut off valves, relays, starting and running capacitors etc. complete all as directed
190Dismantling of defective worn out wiring of Refrigerator of capacity 310 Ltr inverter type including unserviceable cordless electronic remote control, supply and fixing PCB (Printed circuit Board) & Visual Eye demo plate to suit /match the existing system complete all as specified and directed.
191Dismantling of defective worn out wiring of Refrigerator of capacity 180-250 Ltr inverter type including unserviceable cordless electronic remote control, supply and fixing PCB (Printed circuit Board) & Visual Eye demo plate to suit /match the existing system complete all as specified and directed.
192Dismantling and taking down carefully for Repair/ servicing of 3 phase, 415 V, 19 KW, 30 Kgs Capacity of Fully automatic Industrial Front loading WASHING MACHINE with Model No LME 30 of Make STEFAB INDIA LIMITED alongwith control panel duly disconnected the electrical and mechanical connections, for cleaning and servicing including necessary repair/maintenance by greasing welding works wherever required, cleaning of moving parts and inner perforated moving drun, tightening nuts and bolts and necessary electrical connections including testing complete for making it completely functional and replacement of damaged unserviceable spares as required and as directed.NOTE :(i) Spares Parts wherever required will be Measured and Paid separately under respective Items.(ii) QUOTED UNIT RATE shall also deemed to be included for any Minor Parts such as Capilary Tube, Machine Screw, Washer, Rubber Bush, etc. required for proper setting of Machine.
193Supply only Reversing timer Complete all as directed
194Dismantling and taking down carefully for Repair/ servicing of 3 phase, 415 V, 19 KW, 30 Kgs Capacity of industrial HYDRO EXTRACTOR with Model No HX 30 of Make STEFAB INDIA LIMITED alongwith control panel duly disconnected the electrical and mechanical connections, for cleaning and servicing including necessary repair/maintenance by greasing welding works wherever required, cleaning of moving parts and inner perforated moving drun, tightening nuts and bolts and necessary electrical connections including testing complete for making it completely functional and replacement of damaged unserviceable spares as required and as directedNOTE :(i) Spares Parts wherever required will be Measured and Paid separately under respective Items.(ii) QUOTED UNIT RATE shall also deemed to be included for any Minor Parts such as Capilary Tube, Machine Screw, Washer, Rubber Bush, etc. required for proper setting of Machine.
195Supply only 'V' Belt, Complete all as directed
196Dismantling and taking down carefully for Repair/ servicing of 3 phase, 415 V, 19 KW, 30 Kgs Capacity of industrial DRYING TUMBLER with Model No LME 30 of Make STEFAB INDIA LIMITED alongwith control panel duly disconnected the electrical and mechanical connections, for cleaning and servicing including necessary repair/maintenance by greasing welding works wherever required, cleaning of moving parts and inner perforated moving drun, tightening nuts and bolts and necessary electrical connections including testing complete for making it completely functional and replacement of damaged unserviceable spares as required and as directedNOTE :(i) Spares Parts wherever required will be Measured and Paid separately under respective Items.(ii) QUOTED UNIT RATE shall also deemed to be included for any Minor Parts such as Capilary Tube, Machine Screw, Washer, Rubber Bush, etc. required for proper setting of Machine.
197Supply only Temp controller cum indicator for item No 196 here-in-above Complete all as directed
198Supply only Reversing timer for item No 196 here-in-above Complete all as directed
199Supply only Contactor 196 A Complete all as directed
200Supply only Indicating lamp Complete all as directed
201Opening carefully of Voltage stabiliser of capacity 5 KVA, removing the old U/S, rewinding of the current transformer with stranded super enamelled copper winding wire as per existing size/gauge repairing the same with minor parts as required to make it functional complete all as specified and directed.
202All as per item No- 201 above but Voltage stabiliser of capacity 4KVA
203All as per item No- 201 above but Voltage stabiliser of capacity 2.0 KVA
204All as per item No- 201 above but Voltage stabiliser of capacity 1.0 KVA Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57122273
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 03-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maintenance Of Geysers And Summer Appliances Incl Mechanical Laundry Under Ge Missamari
Basic Detail
Tender No 8703/E8
Bidding Type Tender
Location
City Sonitpur
State Assam
Key Dates
Publish Date 20 Aug 2026
Submission Date 03 Sep 2026
Open Date 05 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 80000
Exemption Available
Document List
1e02ca36-a2ae-47ca-bea6-69d110d5fb66.html
BOQ_880293.xls
Tender8703.rar
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Sep 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

1e02ca36-a2ae-47ca-bea6-69d110d5fb66.html

xls

BOQ_880293.xls

rar

Tender8703.rar

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders