Tender For Repair/ Maintenance Of Lt Panels Starters, Mccbs, Junction Box Lt Distribution Network And Allied Items At Sunjuwan Under Ge Jammu.
Tender Value
18.50 Lakhs
Estimated cost
Bid Submission
10 Sep 2026
17 days left
EMD
37000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jammu → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/ Maintenance Of Lt Panels Starters, Mccbs, Junction Box Lt Distribution Network And Allied Items At Sunjuwan Under Ge Jammu.
BOQ
| Sl. No. | Item Description |
| 1 | LT Feeder pillar box suitable for LT supply, outdoor type factory made powder coated dust and vermin proof, double door made out of 3.15 mm thick CRCA sheet mounted on mild steel angle iron with water proof top canopy, front and back door operated with suitable locking arrangement, sheet steel enclosure, cable entry detachable bottom plates erected on and including PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) pedestals finished with degree of protection IP-54 and including the following accessories: -(a) TPN bus bars fixed on epoxy bus bar insulator capacity 320 Amps - 1 Set.(b) MCCB 200 Amps 4 Pole 16 KA-1 No (incoming).(c) MCCB TP 160 Amps - 1 Set (for starter).(d) MCB 3 Pole, 40 Amps 415 V 10KA, C curve.(e) Cylindrical type capacitor 50 KVAR with suitable size MCB SPN - 01 No.(f) Star delta starter for 100HP submersible pump - 01 No.(g) LED Phase indicator lamps (R, Y, B) - 1 Set.(h) Single phase preventer - 1 No.(j) Digital Multifunction meter to measure KWh, PF, VLL, VLN, W, VA, V, I and WH including CT and PT complete with all electrical connection - 01 No.Notes: - (i) Rates are inclusive for fixing of suitable size cable gland, LT end termination joint kits, CT/ PT and electrical connection complete to function multi functional meter.(ii) All ACB/MCCB/ MCB must be fixed in vertical position. |
| 2 | LT Feeder pillar box suitable for LT supply, outdoor type factory made powder coated dust and vermin proof, double door made out of 3.15 mm thick CRCA sheet mounted on mild steel angle iron with water proof top canopy, front and back door operated with suitable locking arrangement, sheet steel enclosure, cable entry detachable bottom plates erected on and including PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) pedestals finished with degree of protection IP-54 and including the following accessories: -(a) Aluminium TPN bus bars fixed on epoxy bus bar insulator capacity 250 Amps - 1 Set.(b) MCCB 160 Amps 4 Pole 16 KA-1 No (incoming).(c) MCCB 3 P 100 Amps - 1 Set (for starter).(d) MCB TP, 63 Amps - 1 Set (Spare).(e) Cylindrical type capacitor 35 KVAR with suitable size MCB SPN - 01 No.(f) Star delta starter for 60HP submersible pump - 01 No.(g) LED Phase indicator lamps (R, Y, B) - 1 Set.(h) Single phase preventer - 1 No.(j) Digital Multifunction meter to measure KWh, PF, VLL, VLN, W, VA, V, I and WH including CT and PT complete electrical connection - 01 No.Notes: - (i) Rates are inclusive for fixing of suitable size cable gland, LT end termination joint kits, CT/ PT and electrical connection complete to function multi functional meter.(ii) All MCCB/ MCB must be fixed in vertical position. |
| 3 | LT Feeder pillar box suitable for LT supply, outdoor type factory made powder coated dust and vermin proof, double door made out of 3.15 mm thick CRCA sheet mounted on mild steel angle iron with water proof top canopy, front and back door operated with suitable locking arrangement, sheet steel enclosure, cable entry detachable bottom plates erected on and including PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) pedestals finished with degree of protection IP-54 and including the following accessories: -(a) Aluminium TPN bus bars fixed on epoxy bus bar insulator capacity 100 Amps - 1 Set.(b) MCCB 63 Amps TPN 16 KA-1 No (incoming).(c) MCCB TP 40 Amps - 1 Set (for starter).(d) MCB TP, 40 Amps - 1 Set (Spare).(e) Cylindrical type capacitor 15 KVAR with suitable size MCB SPN - 01 No.(f) Star delta starter for 20HP submersible pump - 01 No.(g) LED Phase indicator lamps (R, Y, B) - 1 Set.(h) Single phase preventer - 1 No.(j) Digital Multifunction meter to measure KWh, PF, VLL, VLN, W, VA, V, I and WH with CT and PT complete electrical connection - 01 No.Notes: - (i) Rates are inclusive for fixing of suitable size cable gland, LT end termination joint kits, CT/ PT and electrical connection complete to function multi functional meter.(ii) All MCCB/ MCB must be fixed in vertical position. |
| 4 | LT Feeder pillar box suitable for LT supply, outdoor type factory made powder coated dust and vermin proof, double door made out of 3.15 mm thick CRCA sheet mounted on mild steel angle iron with water proof top canopy, front and back door operated with suitable locking arrangement, sheet steel enclosure, cable entry detachable bottom plates erected on and including PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) pedestals finished with degree of protection IP-54 and including the following accessories: -(a) Aluminium TPN bus bars fixed on epoxy bus bar insulator capacity 100 Amps - 1 Set.(b) MCCB 40 Amps 4 pole 16 KA - 1 No (incoming).(c) MCCB TP 25 Amps - 1 Set (for starter).(d) MCB TP, 20 Amps - 1 Set (Spare).(e) Cylindrical type capacitor 10 KVAR with suitable size MCB SPN - 01 No.(f) Star delta starter for 12 to 15 HP submersible pump - 01 No.(g) LED Phase indicator lamps (R, Y, B) - 1 Set.(h) Single phase preventer - 1 No.(j) Digital Multifunction meter to measure KWh, PF, VLL, VLN, W, VA, V, I and WH with CT and PT complete electrical connection - 01 No.Notes: - (i) Rates are inclusive for fixing of suitable size cable gland, LT end termination joint kits, CT/ PT and electrical connection complete to function multi functional meter.(ii) All MCCB/ MCB must be fixed in vertical position. |
| 5 | Earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 meter below ground level not less than 1.5 m below normal ground level connected to earth wire 4 mm dia as earth lead by means of nuts and bolts, washer made out of copper of tinned brass and protecin GI pipe of 25mm dia all as specified and testing complete including earth work, PCC chamber, RCC cover with handle, GI pipe 20mm dia light grade for watering with GI funnel wire mesh, salt, charcoal, lugs complete all as specified and as directed. Notes: - (i) The rates if inclusive of earth work and excavation in any strata, PCC chamber in PCC (1:3:6) type C-1 RCC cover slab 50mm thick with 8mm dia TMT bars both ways at 140mm centre to centre. |
| 6 | Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 Sqmm 3.5 core complete all as specified and as directed. |
| 7 | Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 3.5 core complete all as specified and as directed. |
| 8 | Supply and fixing of 95 Sqmm single core stranded annealed copper conductor, XLPE insulated, PVC sheathed 1.1 KV grade cable, conforming to IS 7098, suitable for connection from LT panel to motor starter complete with suitable size of copper glands, thimbles, ferruling, tag, clamps and all accessories for proper termination and commissioning, including taking down old one complete all as specified and as directed. |
| 9 | Supply and fixing of 50 Sqmm single core stranded annealed copper conductor, XLPE insulated, PVC sheathed 1.1 KV grade cable, conforming to IS 7098, suitable for connection from LT panel to motor starter complete with suitable size of copper glands, thimbles, ferruling, tag, clamps and all accessories for proper termination and commissioning, including taking down old one complete all as specified and as directed. |
| 10 | MCCB 63 Amp, 50 Hz, 415 V 4 pole with rupturing capacity 16 KA including addition and alteration in existing panel complete all as specified and as directed. |
| 11 | Boring of holes under road, pavement and hard standing by trenchless technology using ultra sound technique and necessary machine for insertion of GI pipe 50mm outer dia complete all as specified and as directed.Notes: - (i) GI pipe shall be measured and paid separately under relevant items of this Schedule.(ii) Depth will not be less than 1m below the road. |
| 12 | Excavation in trenches in soft/ loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out complete all as specified and as directed. |
| 13 | Returning, filling in of trenches in two parts: -(i) Using riddled soil obtained from excavated soil upto depth of 30cm (8 cm below cable and remaining above cable) for cushioning of cable and (ii) Refilling the trench of remaining depth with normal excavated soil complete all as specified and as directed.Note: - Excavated soil shall be riddled by using sieve to separate composite particles etc as per IS 1255-1983 and refilling in trenches as in cable cushioning. |
| 14 | Removing excavated surplus soil obtained from excavation to a distance not exceeding 50 Metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed. |
| 15 | Supply and laying well burnt bricks sub class 'B' of size 23 x 11.5 x 7.5 cm for cable protection laid length wise perpendicular to the axis of the cable, adjacent to each other complete all as specified and as directed by Engineer-in-Charge. |
| 16 | Supply and fixng of green shade multipurpose HDPE Net 90% superior quality to cover the chain link fencing surrounding by tightening by high quality PVC tegs with the iron angle and mild steel pipe at a distance of to 2.6 feet gap on platform of the transformer to avoid approaches of animals/ children and unwanted persons for safety measures complete all as specified and as directed by Engineer-in-Charge. |
| 17 | Supply and fixing 50 mm dia GI tubing, medium grade with all fittings laid in trenches/ road crossing for underground cable protection complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 20, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysSep 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender