Tender For Maintenance And Repair Of Perimeter Security Lights, Road Lights, Timer Panels, Feeder Panels And Its Related Works At Dgqa Area Under Ge (Mh & Rh) Khadki
Tender Value
Ref. Documents
Estimated cost
Bid Submission
10 Sep 2026
17 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Maintenance And Repair Of Perimeter Security Lights, Road Lights, Timer Panels, Feeder Panels And Its Related Works At Dgqa Area Under Ge (Mh & Rh) Khadki
BOQ
| Sl. No. | Item Description |
| 1 | Taking down old UNSV LT UG cables of size upto 70 Sq mm from trenches / poles / ducts etc. |
| 2 | Supplying, laying, jointing, commissioning and testing XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade confirming to IS-7098 (Part-I-1988) laid in trenches/ducts/wall / floor / pipes/ poles including cable glands and aluminium lugs of appropriate size, PVC sleeve etc complete all as directed by Engr in -Charge for following sizes . Make :- Polycab/Havells / Gloster / Finolex NOTE :- Earth work , bricks , riddled earth , GI pipe for protection of cable will be measured & paid under under relevant items of schdule . |
| 3 | 50 sq mm 3.5 core . |
| 4 | 35 sq mm 3.5 core |
| 5 | 25 sq mm 3.5 core |
| 6 | 16 sq mm 4 core. |
| 7 | 10 sq mm 2 core |
| 8 | 6 sq mm 2 core |
| 9 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation of poles stays laying of electric cables, pipes etc and getting out in soft/loose soil complete all as specified and directed. |
| 10 | Ditto item no 3 but in hard/dense soil. |
| 11 | Removing excavated material soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed |
| 12 | Returning, filling in, including spreading, levelling watering and well ramming in layers not exceeding 25cm in soft/loose soil complete all as specified and directed. |
| 13 | M & L for riddled earth for cushioning to under ground electric cable including spreading , levelling and hand punning complete all as directed. Note - Punned thickness shall only be measured & paid . |
| 14 | M& L for road cutting/foot path and making good with PCC 1:3:6 TYPE C-2 ( using 40 mm graded stone aggregate ) of 150 mm |
| 15 | Supply and laying un-reinforced precast concrete cable cover LV, Type I, flat, size 250mm x 150mm x 40mm for Under ground cable all as specified and directed. |
| 16 | Supply and laying GI tubes light grade, galvanized, 40 mm bore in repair ,laid in trenches or under floor or fixed with poles/walls for protection of electric cable all as directed |
| 17 | Ditto item no -10 but 80 mm bore. |
| 18 | Plain cement concrete (PCC) type C2 1:3:6 using 40mm graded aggregate stone for making foundation of Pole/stay assembly |
| 19 | Plain cement concrete (PCC) type C1 1:3:6 using 20mm graded aggregate stone for making copings of Poles etc. |
| 20 | M&L earthing complete with galvanised steel earth plate eletrode 600x600x6mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5m below normal ground level, connected to the earth lead wire 4.0 mm dia (GI wire) size, by means of bolts, nuts, check buts and washers of galvanised iron, earth lead wire 4.0 mm dia protected by provision of GI medium grade pipe 15 mm bore including provision of aggregates with 40 mm thick cover of RCC (1:2:4) , re-inforced with XPM (weight not less than 4 kg per sqmm) and frame of angle iron 40x40x3 mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edged of earth plate, common salt and charcoal filling, funnel, wire mesh and earth work in hard/dense soil, returning filling in distance not exe 50 mtr and removal of surplas soil to plate No 3 of SSR 2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion complete all as specified and directed. |
| 21 | M & L earthing complete with galvanized steel earth plate electrode 60 cm x 60cmx6 mm thick, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level , connected to 32x6 mm GI strip as earthling lead by means blots and nuts check nuts and washers of galvanized iron and connected to main switch board including watering arrangement with PCC chamber , MS funnel, wire gauge. CI cover with frame , 50 MM dia GI pipe light grade for protection of wire/strip etc including necessary excavation in any type of strata , returning, filling removal of soil outside MD land ,filling of charcoal and salt complete all as shown in electrical plate No. 3 of MES Sch Part I , connected to Earthing test point all as specified and directed on testing on completion. |
| 22 | M& L for detection of street light LT UG cable fault with the help of cable fault detecting machine with experinced engineer and helper including necessary earth work complete & jointing the fautly cable with new joint , testing etc complete all as directed .Note :- Cable joint kit will be measured and paid separately under relevent item of schedule . |
| 23 | Supply only straight through joint kit , heat shrinkable type suitable for LT UG electric cable 1100 volts grade of size up to 16 sq mm 2/3.5/4 core cable complete all as directed . |
| 24 | Supply only straight through joint kit , heat shrinkable type suitable for LT UG electric cable 1100 volts grade of size from 25 up to 50 sq mm3.5/4 core cable complete all as directed . |
| 25 | Supply and fix in repair brass terminal 4 way, 63/100 Amps capacity with bakelite insulator fixed in street light junction box complete all as directed . |
| 26 | Taking down old unserviceable rusted damaged street light pole 9 mtr/ 11 mtrs long of any type complete from site . |
| 27 | Supply and errect in vertical position Steel tubular swaged poles, type 410 SP- 31 (09 mtr long) in replacement with 300mm x 300mmx6mm mild steel plate continiusly welded to pole, final taper plug, bolts,nuts and screws and making holes as per requirement all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embeded portion and applying one coat fo red oxide primer, making 05 Nos strip each 30 cm high with super enamel paint ( Black and yellow) from ground level / coping upto 1.5 m, painting with two coats of aluminium paint for the remaning height complete all as specified and directed.Note :- PCC in foundation, copping, excavation and earth work shall be measured and paid separately under relevent items of sch. |
| 28 | Supply and Erect in true vertical position , LT electric pole, Octogonal pole , hot deep galvanised in replacement with base plate of 220x220x12mm thick , 07 mtrs long , top dia 70mm , bottom dia 135 mm thickness of sheet - 3mm, including single arm GI bracket , inbuilt cable junction box with door , connection plate, MCB 6 A, duly connecting existing LT UG cable, cable lugs , work included necessary earth work and RCC foundation as per manufacturers recommendation complete all as specified and as directed.Make: Bajaj / Crompton Note: Earth work, PCC foundation, foundation bolts as per manufacturer recommendation included in the unit rate. |
| 29 | Taking down old unsv Flood light fitting of any type/capacity from its location complete . |
| 30 | Supply and Fix in replacement LED Flood light fitting of capacity 120 watts made up of pressure die cast aluminium housing with toughned glass and high power LED's and secondary lenses, having system efficacy greated than 110 lumen per watts with surge protection device included. The luminaries shall be totally enclosed dust and water proof with minimum IP -66 protection pre wired up to connector including 2.5 sq mm PVC insulated cable for making connection (upto 9 mtr length), complete all as specified and directed by Engr-in-charge.Make :- Halonix/Crompton/Benlo. |
| 31 | ditto- all as per item no -24 but of capacity 150 watts |
| 32 | ditto- all as per item no -24 but of capacity 200 watts |
| 33 | Dismantling and Taking down old unsv street light fitting of capacity upto 120 watts from its location complete . |
| 34 | Supply and Fix in replacement LED Street light fitting of 90/100 Watt (Cool White) including LED lens complete with body robust, corrosion resistant, superior finish, made up of high pressure die cast aluminium alloy housing. The luminaries shall be totally enclosed, dust and water proof with minimum IP - 66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 300 V, AC, frequency 50 - 60 Hz, P.F should be more than 0.95 with Total Harmonic Distoration THD(I) less than 10% , cool white colour and lamp starting time should not be more than 10 second fitting should be provided with 10 KV surge protection. Driver should be constant current constant voltage driver .Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection,no load , open circuit and short circuit protection . The efficiency of LED luminaries system shall be more than 100 lumens per watt and must be certified by the LM-79 test report and including provision of connection for street light from pole box with 2.5 Sqmm PVC insulated stranded copper conductor FRLSH cable (upto the lenght og 9 mtr) complete all as specified and directed by Engineer-in- charge.Make :- CROMPTON / HALONIX /BENLO |
| 35 | Ditto item no 28 above but of 60 Watt Make :- CROMPTON / HALONIX /BENLO |
| 36 | Ditto item no 28 above but of 45 Watt Make :- CROMPTON / HALONIX /BENLO |
| 37 | Supply and Fix in replacement Inverter LED Street light fitting of 90 Watt including LED lens complete with body robust,corrosion resistant,superior finish and without any cracks or through holes,made in a single piece by high pressure die cast aluminium alloy having inbuilt battery back-up for upto 2 hrs with auto ON/OFF.The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP -66 protection as per IS - 10322-1982(Part -I) with latest ammendments and input voltage range 140 - 300 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.95 with Total Harmonic Distoration THD(I) less than 10% ,cool white colour and lamp starting time should not be more than 10 second fitting should be provided with 10 KV surge protection. Driver should also have double phase protection,no load , open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from -10 degree Centrigrade to 60 degree Centrigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 66 degree protection. The efficiency of LED luminaries system shall be more than 100 lumens per watt and must be certified by the LM-79 test report complete all as specified and directed by Engineer-in- charge.Make :- HALONIX /BENLO/CROMPTON/JAQUAR |
| 38 | S&F in repairs Bracket for fixing of street light fittings bend to shape, made out of 40 mm dia GI pipe medium grade upto 1.5 mtr long fixed with two sets of MS clamps made out of flat iron of size 50x6 mm fabricated to shape and fixed with nuts bolts and washers & two coats of aluminium paints over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge(Note : MS clamps, nuts, bolt and washer shall be measured seperately under relevant item) |
| 39 | S & F in repair of three core PVC insulated and FR PVC round sheathed, copper conductor 1100 volts grade cable of size 0.5 sqmm (multi stranded) complete all specified and directed by Engr-in-charge. Please Enable Macros to View BoQ information |
| 40 | S & F in repair of three core PVC insulated and FR PVC round sheathed, copper conductor 1100 volts grade cable of size 0.5 sqmm (multi stranded) complete all specified and directed by Engr-in-charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 20, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysSep 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender