Tender For Special Repair To Pump House And Building No Np-68 Alongwith Ancillary Work Services At Sata Bty And special Repair To Sewage Line At Offirs Md Accn At Rana Sanga Enclaves At Mil Stn Kaluchak Under Ge Kaluchak.
Tender Overview
Project Description
Tender for Special Repair To Pump House And Building No Np-68 Alongwith Ancillary Work Services At Sata Bty And special Repair To Sewage Line At Offirs Md Accn At Rana Sanga Enclaves At Mil Stn Kaluchak Under Ge Kaluchak.
BOQ
| Sl. No. | Item Description |
| 1 | Taking out carefully copper/aluminium point wiring,Light,fan,socket or power complete with all fitting, fixtures such as switch socket out let, ceiling rose ,holder ,regulator,DBs etc including making good the disturbed surface of wall/floors complete all as specified and directed |
| 2 | Taking down distribution boards/wooden board ,switch fuse units,steel enclosures for MCB of any type and removing from site all as specified and as directed. |
| 3 | Taking down existing unserviceable submain wiring any size and making good the disturbed surface all as specified and as directed. |
| 4 | Dismentaling &Taking down unserviceable street light/Flood light fittings from pole or from Bldgs for replacement of unserviceable lights from junction boxes to light fitting all as specified and as directed. |
| 5 | M&L for point wiring for one light/fan/call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 sqmm copper conductor multistrand FRLS, PVC insulated (unsheathed) drawn into and including new concealed PVC rigid/ 1.8mm wall thickness ISI marked including Modular Metal flush Boxes of any way i.e. (1 to 8 way as per site requirement) with suitable outer plates for mounting switches, sockets, fan regulators etc complete all as specified and as directed for the following :- Note: suitable Modular white cover sheets with frame as specified to be provided in replacement to MS/Galvanised sunken boxes and measured & paid separately as per relevant item.Note : (a) wiring shall be done by using proper colour coding including making disturb surface good(b) Earth wire shall be of green colour (c) On RCC roof/celing PVC conduit shall be provided on surface with proper fixing clamps all as directed by Engr-in-Charge. |
| 6 | All as per item No 05 here in above but 5 Amp socket outlet on same board complete all as specified and directed |
| 7 | All as per item No 05 here in above but socket outlet 5 Amps independent board complete all as directed. |
| 8 | All as per Item no 05 here-in-before but for one15 Amp 6 pin switch socket outlet, independent with 2.5 Sqmm single core multi-stranded copper conductor cable (FRLS) along with 2.5 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire all as specified and as directed. |
| 9 | S&F Modular switch 1 way 6A,1 module , 240 volts ISI marked complete all as specified and directed |
| 10 | S&F Modular switch 1 way 16A, 1 module , 240 volts ISI marked complete all as specified and directed |
| 11 | S&F Modular Socket, 6A - 3 pin combined 2 module, , 240 volts ISI marked complete all as specified and directed |
| 12 | S&F Modular Socket 6A/16A - 3 pin combined 2 module, , 240 volts ISI marked complete all as specified and directed |
| 13 | S&F Ceiling Rose 3 terminal surface type complete all as specified and directed |
| 14 | S&F for Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed |
| 15 | S&F LED Bulb cool white 10 Watt Elegant design direct fit for easy installation all as specified and directed. |
| 16 | S&F Modular Fan step regulator, 120W 1 module , 240 volts ISI marked complete all as specified and directed |
| 17 | S&F LED lights fitting 1x 20W, 220V, AC decorative box type complete with LED tube rod 20 watts driver, holder and power factor >0.95 , SPD 2.5 KV, 100 Lumen/Watt, 6500 K cool day type conforming to ISI including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. (4' ft long ) with LED rod 20 watt, 230 Volts 50 Hz. complete all as specified and directed |
| 18 | Supply and fixing factory made epoxy powder coated Distribution board SPN 8 ways (SPN MCB DB) with metal door (IP-54 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 100 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cale management, top and bottom removable gland plates with Knockouts and suitable for one SPN/DP-MCB as incomer and SP MCBs outgoing complete all as specified and confirming to IS : 8623. |
| 19 | Supply and fixing factory made epoxy powder coated Distribution board SPN 4 ways (SPN MCB DB) with metal door (IP-54 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 100 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cale management, top and bottom removable gland plates with Knockouts and suitable for one SPN/DP-MCB as incomer and SP MCBs outgoing complete all as specified and confirming to IS : 8623. |
| 20 | Supply and fix MCB SP-06 to 32 Amp,10KA, 240 volts complete all as specified and directed |
| 21 | Supply and fix of MCB SPN 32 Amp, 240 volts 50Hz AC supply, complete all as specified and directed |
| 22 | M&L in repairs for Sub main wiring with proper colour coding , insulated , unsheathed , multistranded ,copper conductor FRLS, cable of 2 run 6 Sqrmm for phase and neutral and one run of 6.0 Sqrmm for earth wire unsheathed , miltistranded , copper conductor FRLS, drawn through the existing rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length. complete all as specified and directedNote : Wiring shall be done in proper colour coding. |
| 23 | M&L in repairs for Sub main wiring with proper colour coding , insulated , unsheathed , multistranded ,copper conductor FRLS, cable of 2 run 4 Sqrmm for phase and neutral and one run of 4 Sqrmm for earth wire unsheathed , miltistranded , copper conductor FRLS, drawn through the existing rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length. complete all as specified and directedNote : Wiring shall be done in proper colour coding. |
| 24 | Repair and fixing of ceiling fan complete with blades, and accessories obtained vide with provision of new anti suicide fan rod(Suitable size and length and oiling/greasing of fan with provision of flexiable cable twin core all as reqd at site all as specified and directed. |
| 25 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm connecting electrically using 3 core 0.75 Sq mm PVC insulated flexible copper conductor cable over all sheathed all as required at site and as directed.complete all as specified and directed. |
| 26 | M & L for earthing complete with galvanized steel earth plate 600x600x6mm thick buried vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of the plate not less than 1.50 mtr below normal ground level, connected to GI earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron and connection to main switch board of panel, including watering pipe GI 20 mm bore light grade 15mm bore for earthing lead, wire mess, funnel, salt, charcoal dust, excavation and refilling pit with PCC 1:2:4 type B1(using 20mm dia stone aggregate) reinforced with 6mm dia round bar @ 75mm cement concrete both always with MS handle 12mm dia and frame all as shown in electric plate No 3 in page 497 of SSR Part I (2009) and pouring extra Clay Soil of qty not less than one cubic meter into the earth pit and also removal of excavated soil not less than 50 mtr from the earthing place all as specified and directed and tested on completion. including testingall as specified and directed. |
| 27 | Supply and fix Integral LED Bldg FLOOD light luminaire 120W LED 230 volts made of pressure die cast aluminium housing with high power LED’s lens & toughned glass IP-66 suitable for mounting existing bracket of size 32/40mm dia G I pipe or ms angle, fixing clamps ,bolts, nuts of suitable size as required at site complete all as specified and as directed. |
| 28 | Supply & Fixing in replacement PVC insulated weather proof sheated alluminium cable 10 sq mm 2 core complete all as specified and as directed. |
| 29 | Fabrication and fixing in replacement of glow sign board of size 2 x 1 mtr made out of plain Galvanized M.S. Sheet of thickness 1.0 mm duly mounted on MS angle 25x25x5mm duly fixed by screwes and the front side covered with 3.0 mm thick white acrylic sheet and further covered with Dark Blue Vinyl sheet duly cut the letterrings by computerized cutting plotter and pasted on the acrylic sheet and fixed properly with the frame structure by means of nuts/bolts/washers etc. including 05 Nos 20 watt Led tube light fittings and necessary electrical connections with 1100 v grade PVC insulated multi flexible copper wire of size 1.5 sqmm complete all as specified and as directed All as specified and directed. NOTE:- letter to be written on will be as directed by Engr-in-charge/GE |
| 30 | Demolition of cement concrete ( un reinforced ) in ground floors and paving n exc. 15 cm. Thickness, below or above ground level . complete all as specified and directed |
| 31 | M&L for quick setting cement (sika monotop 108 waterplug) including surface preparation and repair for capillary rise water stop complete all as specified and directed |
| 32 | M&L for PCC 1:1.5:3 Nominal Mix (using 20mm agg) as in floor complete all as specified and directed |
| 33 | M&L Rendering, 15 mm thick on brick / concrete surfaces in cement mortar 1:4, mixed with water proofing compound surfaces finished even and smooth using extra cement all as directed. |
| 34 | Supply only Integral water proofing compound liquid complete all as specified and directed |
| 35 | M&L for Home Sheild PU Roofkoat (or equivalent) is a one component liquid, solvent free, cold applied water-proofing membrane that is highly elastic and UV resistant with 10 years warranty. ASTM D 6083-97 a waterproofing and heat reflecting system having following key performace properties : 1. UV resistant, prevent yellowing and weathering2. Highly elastic upto 350% and crack bridging3. Excellent adhesion on porous and non-porous substrates4. Tensile strength > 10 N/mm2 with Geo Textile fleece5. Soler reflective Index (SRI) more then 109-111 ASTM E 1980-11 System :First coat : Providing and applying primer over the prepared surface with HS PU roofkoat Primer (or equivalent)Coverage :0.2kg/m2 (with 50 % dilution of water)Reinforcement : Geotextile 40 gsmSecond coat : Home sheildroofkoat (or equivalent)Consumption : 0.5 kg/m2Third coat : HS PU roofkoat (or equivalent)Consumption : 0.8 kg/m2 System buildup-1.5kg/sqm with geotextile of 40 gsmFor accessible roof, tiles with scred/ adhesive may be fixed thereafter.Note :-The concerned items should be executed by OEM authorized applicator after signing of MOU (format attached as Appendix 'CD' on page no. 96 of tender documents as per Sch 'A' Note No 19 Page No 17). |
| 36 | M&L Crystal glass porcelain tile random 3 colour of size (25mm x25 mm) and thickness 3.5 to 5mm with water absorption less than 0.05% on floor/vertical surfaces in swimming pool of approved manufacturer and specified shade like Orient Blue / Dark Blue / new blue or any pattern etc. laid in approved pattern on 3-6 mm ( 5mm average) thick bed of adhesive mortar of Polymer modified cementitious adhesive in conjuction with polymer modified liquid equivalent product of etc mixed in required porportion as specified by manufacturer including filling / sealing of joints 2-3 mm thick between the tiles with epoxy with matching colour pigment to make it water tight and finished neat complete all as specified and directed. |
| 37 | M&L Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc including brushing neat cement slurry with 3.0kg of cement per Sq. Metre complete all as specified and directed |
| 38 | M&L Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid over & including 15 mm thick screed base in CM 1:6, jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, grinding and polishing to yield mirror finish with machine, complete all as specified and directed |
| 39 | M&L Machine cut Kota stone slab not less than 19mm thick as in riser of steps, skirting, dado and pillar laid over & including 15 mm thick screed base in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, grinding and polishing to yield mirror finish with machine, complete all as specified and directed |
| 40 | Demolition of brick work masonry built in cement mortar including all quoins, pillars etc. but excluding ashlars facing, dressed stone work and precast concrete articles complete all as specified and as directed. |
| 41 | M&L for Brick work with sub class ‘B’ bricks, (old size) straight or curved on plan exceeding 6m mean radius built in in CM 1:6, but except bricks complete all as specified and directed. |
| 42 | M&L for Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6m mean radius built in in CM 1:6, complete all as specified and directed. |
| 43 | Taking down cement plaster on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed |
| 44 | M&L for Rendering 15 mm thick on fair face of brick work or concrete surface in CM 1:4, finished even and smooth without using extra cement. complete all as specified and directed Please Enable Macros to View BoQ information |
| 45 | M&L for Rendering 15 mm thick on fair face of brick work or concrete surface in CM 1:4, finished even and smooth without using extra cement. complete all as specified and directed Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender