Tender For Repair And Renovation Of Toilet Blocks At Old And New Judges Court Building, Purba Bardhaman - electrical installation Work With Exhaust Fan & Lights.
Tender Overview
Project Description
Tender for Repair And Renovation Of Toilet Blocks At Old And New Judges Court Building, Purba Bardhaman - electrical installation Work With Exhaust Fan & Lights.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 21-Aug-2026 | Corri_NIQ memo | Other | 07-Sep-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, on wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment [D9/13). (Make ABB ITUS, SIEMENS, L&T )b) (2 + 4 way) |
| 2 | Supplying and fixing 240/415 V , 40 A MCB Isolator on din rail of existing DBs and necessary connection.(D-5/6) |
| 3 | Supplying and fixing 240/415 V(6-32 A) SP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection for SPN Outgoing ( make- Make: Legrand, ABB, SIEMENS)(D-6/7) |
| 4 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make:-Hevells/Polycab/Finolex/RR Kabel ) partly in 20mm size PVC rigid conduit 'FR' (Precision mms make) [for ceiling portion & horizontal runs ] and in 19mm bore, 3mm thick polythene pipe [for vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [PVC Rigid Conduit only for horizontal run & on ceiling and vertical run concealed] (Avg. Run- 8 mtr) (E 25 / 5 c) |
| 5 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make:-Hevells/Polycab/Finolex /RR Kabel ) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S/F 240 V 6A 31 pin Modular1 type plug socket & Mod. type switch (approved by E!IC) incl. S!&F earth continuity wire1 fixed on G I Mod. switch board with Mod. top cover plate flusged in wall incl. mending good the damages as to original finish.2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC .. on board ( E-20/3(i) ) |
| 6 | Supplying and fixing PVC Rigid Conduit 'FR' [ Make Precision Medium] on wall, ceiling with saddles and other accessories as required and mending good damages to building works (E16/7) a. 20 mm size |
| 7 | Cutting channel of on masonry wall electric operated cutting machine incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works, a) 19 mm dia 3 mm thick polythene pipe without earth continuity wire in 40 mm X 40 mm channel (E3/6 a) |
| 8 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make:-Hevells/Polycab/ Finolex/RR Kabel ) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required.(E-9/1)2 x 84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC ( MS to SPN) [E-9/1y] |
| 9 | 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC.( SPN to power plug and Computer point) [E-9/1s] |
| 10 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes etc..(F-5/9) 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC .(F-5/9) |
| 11 | 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC .(F-5/9) |
| 12 | Supply & Fixing 240 V, 25 A, Modular type starter (Make:-Legrand/Cabtree /Wipro) with 25A Modular switch type DP MCB (C Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.as per GS. [E-19 /17 ] |
| 13 | Supply & Fixing 240 V, 1 x 16 A + 1 x 6A, 5 pin Modular type plug socket (Make:-Legrand/Cabtree /Wipro) with 16A & 6A Modular type switch, without plug top on 6 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-17/1b, 3(a & b) & 4(a & b)] |
| 14 | Supplying and delivery of Single fittings along with S/F of 1 no. 18-20 W LED lamp LED Industrial Batten light made of CRCA Sheet Body (Thickness ≥ 0.50 mm) and construction as per relevant IS, along with LED lamp (Opal finish polycarbonate housing with Aluminium end-cap) voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range 0o to 40o C, internal surge protection of 2.5 KV(internal) with Short & Open circuit protection , THD < 10% , P. F.≥0.9, IP20, CRI >80, and minimum 40000 Burning Hours (Life projection shall be calculated as per TM-21 methodology), CCT 5700°K /6500°K, and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing, with Minimum 1 year OEM warranty. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted.(System lumen efficacy ≥115 lm/Watt) [Make: PHILIPS Cat No-TMC 502 P 2 x TLED,, CROMPTON, WIPRO, Jaquar. With 3 yrs warranty. |
| 15 | Fixng only single/twin florescent light fitting suspended 25 cm 233.000 bellow the ceiling with 2 No 20 mm dia El conduit (14 SWG) supports fixed with \\"L\\" type MS clamp whose one sile fixed on ceiling with sutable size I nos fastener and other sirle connected with the conduit with suitabile size of bolts and nuts incl. S&F EI conduit, \\"L\\" type (125mm 125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0,20 mm (1.5sqmm) flexible copper wire of 110 mt. length [C-2/17] |
| 16 | Supply & delivery of 230 V, 50 Hz, single phase, 75 watts, 15\\" (380 mm) Sweep, speed 900 rpm (minimum), A.C. Exhaust Fan and class of insulation: B, 4 nos. metal (Aluminium alloy) blades, copper winding, steel/Al body. Power Factor not less than 0.9 and minimum air delivery 2000 cmh (minimum) including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 1 year OEM warranty. (Make EPC, Usha, CG) |
| 17 | Supply & delivery of 230 V, 50 Hz, single phase, 80 watts, 12\\" (300 mm) Sweep, speed 1400 rpm (minimum), A.C. Exhaust Fan and class of insulation: B, 4 nos. metal (Aluminium alloy) blades, copper winding, steel/Al body. Power Factor not less than 0.9 and minimum air delivery 1710 cmh (minimum) including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 1 year OEM warranty. (Make EPC, Usha, CG) |
| 18 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy, length of PVC Insulated wire and making connection for exhaust of following diameter: 30 cm (15\\") (C-4/28] |
| 19 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy, length of PVC Insulated wire and making connection for exhaust of following diameter: 23 cm (12\\") (C-4/28] |
| 20 | Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) - 30 cm Exhaust fan (12\\") (D-14/32 b) |
| 21 | b) 38 cm Exhaust fan (15\\") (D-14/32 b) |
| 22 | Supply and fixing net guard Exhust fan hole made with 1'(one) inch square 14/16 swg M.S net , round shaped frame by 20 x 5 m thick MS Plate and Rain water protection shade made by 14 SWG semi circular shape the total frame fixed with the wall by means of suitable size fastener bullet & nuts, bolts incl painting etc.For 30 cm (12\\") Exhaust fan |
| 23 | For 38 cm (15\\") Exhaust fan |
| 24 | Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall with necy. bolts & nuts (6 mm dia x 62 mm long) 30 cm Exhaust fan (12\\") |
| 25 | 38 cm Exhaust fan (15\\") |
| 26 | Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run. (P : J-1/Item-7) |
| 27 | Supply 230 V. 9 W pin type LED bulb (Philips, CG, Havells Make) for batten / angle batten holder. - Non.Sch.with Minimum 1 year OEM warranty. |
| 28 | Fixing only lamp on batten / angle batten holder (C2/11) |
| 29 | Supplying, installation, Testing & Commissioning of 20Watt Street light LED fixture powder coated pressure die cast aluminum body finish with corrosion resistance fasteners (SS hardware) & silicon gasket for proper sealing with driver as per the requirement with Driver efficiency >80%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range 0o to 50o C and working RH 10% - 90%, internal surge protection of 5 KV internal and external SPD min. 10 KV, L,N,E as per IEC 61000-4-5. The driver rated output wattage should be 10% to 15% higher than lamp rating and at least 2 driver for 200W & above and Driver efficiency >85%, THD < 10% as per IEC 61000-3-2 , P. F.≥0.9, IP- 66, IK-08 specified below, CRI >70, under voltage and over voltage protection, high efficiency lens with type II/III distribution as required with UV stabilized optical lens, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours (Life projection shall be calculated as per TM-21 methodology) and 70% of initial Lumen maintained till life ends. CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect and LED Chips of SMD mid to high-power (2.5 to 4 watt for 200 watt and above, as per required (LM- 80 tested) and necessary inter-connections with 1.5 sq mm FR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 1 year OEM comprehensive on-site warranty against manufacturing defects including driver and LED module. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted (Make:-CG -LSTS -20 -CDL NL-M or eqv Philips / Jaquar) |
| 30 | S / Fixing bulk head light fitting (Havells make) ceiling fitting on wall / ceiling by screws incl S/F 12 watt LED lamp complete set inc. connection etc with Minimum 1 year OEM warranty. (D13/23) |
| 31 | Supply & Fixing 240 V 16 A Piano key type switch (Make:-Anchor) on GI Modular type switch board having top cover plate and making necessary connections as required (E - 17/ 3b) |
| 32 | Supply and fixing auto start and auto stop timer switch for automatic controlling of exhaust fans,{ 0 - 60 min delay } ( Make - MINILEC) Model S1ETM1) |
| 33 | Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment 2 Way (D - 9/11) Please Enable Macros to View BoQ information |
| 34 | Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment 2 Way (D - 9/11) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 13 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender