Housing Urban and Rular Development Government Departments Closing in 11 days TDR #57120388

Tender For B.O.Q For Construction Of Additional Accomodation For Sdh Kreeri (2Nd & 3Rd Floor) B.W.O Electric Work

Issued by Government Departments · Baramulla, Jammu and Kashmir
Tender Value
51.39 Lakhs
Estimated cost
Bid Submission
09 Sep 2026
11 days left
EMD
1.02 Lakhs
Bank guarantee accepted
Document Fee
1600
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Baramulla → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for B.O.Q For Construction Of Additional Accomodation For Sdh Kreeri (2Nd & 3Rd Floor) B.W.O Electric Work

BOQ

Name of Work:- B.O.Q for Construction of Additional Accomodation for SDH Kreeri (2nd & 3rd floor) B.W.O Electric work
Sl. No. Item Description
1Wiring for Light point/Fan point/Exhaust fan/Bell point with (P+N+E) 3x1.5 sq.mm FRLS-H PVC insulated Multi strand Copper conductor single core cable, (Havells/Polycab/ Apar/ Anchor/Eq Make) in surface/recessed Conduits laid in slabs (Including Cost of Conduit 25mm) with 01 No.of 6 Amp Modular Switch,Modular Plate,Cover in front & suitable GI box etc ISO/IEC Certified/Schneider/ Havells/ Legrand/Anchor roma plus/ABB/Eq.Make & items shall be approved before execution of work by SDO.
2Group A
3Group B
4Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required,ISO/IEC Certified of Havells/ Legrand/Anchor/Schneider /ABB/Eq Make & shall be approved before execution of work by SDO.
5Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells/ Apar/ Anchor/Polycab/ Eq Make)
6Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required, ISO/IEC Certified /Legran/Anchor roma plus/Schneider/ABB/Eq Make & shall be approved before execution of work by SDO.
7Wiring for 6Amp Plug(Computer Point) with (P+N+E) 3 x 2.5 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells/ Apar/ Anchor/Polycab/Eq. Make)
8Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including proving and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings), ISO/IEC Certified Havells/Legrand/ Anchor roma plus/Schneider/ABB/Eq.Make & shall be approved before execution of work.
9Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS-H PVC insulated copper conductor, single core Cable in surface/Recessed medium class PVC conduit (Havells/Anchor/Polycab/ Apar/ Eq.Make) & shall be approved before execution of work (Including Cost of Conduit/Channel)
104 X 16 sq. mm + 2 X 6 sq. mm earth wire
114 X 10 sq. mm + 2 X 6 sq. mm earth wire
124 X 6 sq. mm + 2 X 6 sq. mm earth wire
132 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
14Supply/Fixing/Testing and Commissioning of 6Amp to 32Amp Rating SP,240v,*C* Curve 10K, Miniature Circuit Breaker suitable for inductive load of following poles in existing MCB DB Complete with connections. (L&T/Siemens/Legrand/Havells/ABB/Eq.Make)
15Supply/Fixing/Testing and Commissioning of following rating, Double pole, (P+N) 240 V, C* Curve 10K,Miniature Circuit Breaker (MCB) in the existing MCB DB complete with connections. (L&T/Siemens /Legrand/Havells/ABB/Eq Make)
1663 Amp.
1732 Amp.
18Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioninq etc. as required.
19Supplying and Fixing of 8-way (4 + 24), horizontal typed , sheet steel, Double Door Distribution Board, TPN 240V/415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (L&T/Siemens/Legrand/ Schneider/ABB/Eq Make)
20Supplying and Fixing of 12-way (4 + 36), horizontal typed , sheet steel, Double Door Distribution Board, TPN 240V/415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (L&T/Siemens/Legrand/ Schneider/ABB/Eq Make)
21Supply/Installation/Testing and Commissioning of 18W + LED Conceal/Surface (Commerical Type) light luminary fitting round shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/government of India authorised lab.The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years,which includes replacement of fixtures of Philips/Havell's/Wipro/Halonix/Eq Make.
22Providing & Fixing of IK08 IP-66 protected high power LED 50 Watt flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each. Integrated potted driver as a unique BIS R number having efficiency more than 85% and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 Im/wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector, Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K 355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR:-High Power LED Flood Light Minimum lumen output 6200 Im of Havells/Crompton/Philips Make as approved and to be installed on outside block including S/F of suitable size of Gyser bolt.The job further includes replacement warranty of fixture (if damaged/burnt out what so ever reason) for a period of two years reckoned from date of successful commissioning /handing over of site to intending department.
23Supply, Installation, Testing and Commissioning of decorative 1200 mm sweep, ceiling fan with 3 No. Aluminium blades, 30 cm long down rod, 2nos. canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, and including iron hook complete . USHA Striker/Havells Oyster matalic/CromptonAura/equivalent make as directed by engineer incharge.
24Supply/Installation/Testing and Commissioning of 225-250mm Shutter Typed,320 Cu.m/Hr.AC 220-240 Volts, 50 Hz Exhaust fan made out of ABS Plastic Material with inbuilt thermo cut-off Protection and Noise Level not exceeding 37dB of Following Sizes including connection etc USHA/Havells/Crompton/Eq. Make.(Min 1-Star)
25Supply/Laying/Connecting and Commissioning of 95 sq.mm 3.5-Core XLPE/PVC insulated and steel armored 1.1 KV grade Aluminum Cable of Havells/Polycab/ Eq. Make with required size of thimbles dully crimped with hydraulic crimping tool including Providing/Fixing of saddles/clips with making of connection and partially to be laid underground through DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refilling the Trench .(Material to be approved before execution)
26Supply/Installation/Testing and Commissioning of CPRI Approved (IS/IEC:61439) Main Controlling Panel,fabricated out of heavy gauge sheet steel ,dully Painted with powder coated paint ,dust protected ,earth terminal fitted on epoxy cleats, volt meter & Ammeters with selector switch & CT Coil of required ratio with all necessary connections & inner wiring of panel on both heating and lighting circuits. The switches are connected with bus bars inside panel & manufacturer CPRI Certified.The switch are adjustable type made of Havells/ L&T/ABB/Legrand/Siemens Make and change over switch should be of Havells/ L&T/Legrand/ Schneider Make.(1) Normal Incomer:a) 200 Amp-4-Pole ,56kA C-CURVE MCCB with extended terminals Havells/L&T/Legrand/Schneider Make as approved=01 No. b) 250 Amps TPN Al. Bus Bar Set = 01 Set,Digital Voltmeter ,Ammeter ,C.T Coils with Selector Switch & Phase indicator Set.Outgoing:(1) Normal outgoing for Heating/AC/Lighting/Inverter etc Load(a) 63-Amp TPN MCB= 03 No. for Heating Points.(b) 40- Amp TPN MCB = 03 No. for Machine Points.(b) 32- Amp TPN MCB = 03 No. for Lighting Points
27ENVIRONMENTALLY SAFE MAINTENANCE FREE COPPER Rod EARTHING SYSTEM Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance Value .Supplying, Installation and Testing of 75 mm copper Pipe Filled with Crystallineconductive Mixture with Eco friendly GEM Backfill Compound 2No. Bags also having Earth pit chamber (300mm x 300mm) with man- hole cover for the above. Including cost of 2OMM Wide copper strip as required in one run fitted with of brass nut bolt & spring washer from EARTHING ROD up to MAIN Control PANEL through DWC High Density Poly ethylene Pipe having Corrugation complete job
28Supply and fixing of PVC ceiling rose (2/3 pin), ISI marked, suitable for connection of light/fan point, complete with necessary accessories, including connections and testing as required of Havells/Anchor/Legrand/Eq.make
29Supply and fixing of Hylum sheet (phenolic laminated sheet), 3 mm / 6 mm / 10 mm thick (as specified), duly cut to required size and shape, fixed with necessary nuts, bolts, screws, washers, spacers etc., including finishing and making good the surface, complete as required
30Supply/Installation/Testing & Commissioning of 20KVA/480V On-Line UPS model DXRT system with 3 phase input and 3 phase output built in OVCD, 1.0 pf, VFI technology, 2-13A DC charger, complete with EnerRocket make 40 nos. 12V/65AH SMF with MS Battery Rack, Battery Link Set and Installation.Eaton/APC/Vertiv/BORRI/Eq.make
31Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
32150 mm width X 50 mm depth X 1.6 mm thickness
33Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
34150 mm width X 50 mm depth X 1.6 mm thickness
35Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S.suspenders including bolts & nuts, painting suspenders reauired.etc as
36150 mm width X 50 mm depth X 1.6 mm thickness
37Supplying and installing following size of perforated painted with powder coating M.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & suspenders etc as required.nuts,painting
38150 mm width X 50 mm depth X 1.6 mm thickness
39Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
40150 mm width X 50 mm depth X 1.6 mm thickness
41Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet,with 4 pole and earth, metal enclosed plug top alongwith 30 A \\"C\\"curve, TPMCB, in sheet steel enclosure, on surface or in recess,with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57120388
AUTHORITY Government Departments
TENDER VALUE 51.39 Lakhs
LAST DATE 09-09-2026
Authority
Authority Name Public Works Department
Work Description Tender for B.O.Q For Construction Of Additional Accomodation For Sdh Kreeri (2Nd & 3Rd Floor) B.W.O Electric Work
Basic Detail
Tender No NIT No.134//2026-27 Dt/20/08/2026
Bidding Type Tender
Location
City Baramulla
State Jammu and Kashmir
Key Dates
Publish Date 20 Aug 2026
Submission Date 09 Sep 2026
Open Date 10 Sep 2026
Finance
Tender Value 51.39 Lakhs
Tender Fee 1600
EMD 1.02 Lakhs
Exemption Not Available
Document List
BOQ_1074857.xls
cb1270bf-ecd2-4300-be62-de5f7a678cf2.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Sep 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_1074857.xls

html

cb1270bf-ecd2-4300-be62-de5f7a678cf2.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders