Tender For annual maintenance Of Street Light Points Installed 9/10/11/12 Mtr. Long Gi Octagonal Pole On Dividng Road Of Sector-58-67, 69-70, Spr-I & Spr-Ii Hsvp Gurugram.
Tender Value
36.12 Lakhs
Estimated cost
Bid Submission
31 Aug 2026
1 days left
EMD
72300
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Gurgaon → Haryana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for annual maintenance Of Street Light Points Installed 9/10/11/12 Mtr. Long Gi Octagonal Pole On Dividng Road Of Sector-58-67, 69-70, Spr-I & Spr-Ii Hsvp Gurugram.
BOQ
| Sl. No. | Item Description |
| 1 | [24.5.2.3]MISCELLANEOUS ITEMS. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia |
| 2 | [23.22.1.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 16 to 100 Amp, 25 KA |
| 3 | [23.22.1.5]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 200 to 250 Amp, 25 KA |
| 4 | [24.13.13]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK. 10 Sq mm 2 core (UnArm.) |
| 5 | [24.13.32]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK. 25 Sq mm 4 core (Arm.) |
| 6 | [24.13.48]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK. 50 Sq mm 4 core (Arm.) |
| 7 | NS) Maintenance/ repair charges of existing 11 KV HT line H-pole and 63 KVA alumn. wound transformers including all material and accessories required for repair of above mentioned 11 KV H-pole, T/F and all other equipment, and complete liaison with DHBVN complete in all respect upto the entire satisfaction of engineer in charge of work. |
| 8 | NS) Pdg. and laying HDPE pipe (ISI) marked of reputed make having 63mm nominal dia pipe of type PN-6-PE-63 confirming to IS:4984 standard including push fitting specials/rubber ring / couplers jointing / associated material with trenchless technology including trenching and route marker as per design the satisfaction of the engineer in charge |
| 9 | NS) Maintenance/ repair charges of existing 11 KV HT line with , HT XLPE cable, including all material and accessories required for repair of above mentioned 11 Kv HT line all other equipment, and complete liaison with DHBVN complete in all respect upto the entire satisfaction of engineer in charge of work. Total length of HT line = (1.2 Km approx |
| 10 | NS) Mtc. / repair charges of existing 11 KV HT line with 50sqmm ACSR conductor , 50sqmm x 3 core / 95/185sqmm x 3 core HT underground cable, metering panel, 63 KVA alum. Wound T/F including GI switch and RD fuse all material accessories required for repair of above mentioned 11 KV HT line all other equipment, and complete liaison with DHBVN complete in all respect upto the entire satisfaction of engineer in charge of work Total length of HT line = 4.2 KM appx.. No. of T/F = 10 Nos |
| 11 | NS) Repair and Maintenance charges of LED street light / Flood lights points from 90 watt to 200 watt installed on 9 mtr./11 mtr. long PCC /STP poles/High Mast, ON/OFF operation and fault finding of electrical circuits, cost of material charges i.e. Driver/SPD/PCB/ PVC tape roll/screw etc. arranging of T and P i.e. Hydraulic ladder/alum. Ladder, safety belt, safety shoes etc.) on various sectors / master roads complete in all respect up to the entire satisfaction of engineer in charge of work. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 20, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 31, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 daySep 01, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender