Tender For annual maintenance Of Street Light Points Installed In Hsvp Mts Sector-1 Kosli, Sector-1 Pataudi, Sector-5 (Commercial), 10, 18, 19 Rewari And At Water Works In Sector-4, 18, 18 & Kalka Village And Staff Colo Y Sector-1 Rewari For The Year
Tender Overview
Project Description
Tender for annual maintenance Of Street Light Points Installed In Hsvp Mts Sector-1 Kosli, Sector-1 Pataudi, Sector-5 (Commercial), 10, 18, 19 Rewari And At Water Works In Sector-4, 18, 18 & Kalka Village And Staff Colo Y Sector-1 Rewari For The Year 2026-27 (Idc)
BOQ
| Sl. No. | Item Description |
| 1 | [24.1.1]EARTHING AND LIGHTENING ARRESTOR . Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. |
| 2 | [24.1.2]EARTHING AND LIGHTENING ARRESTOR . Extra for using salt and char coal/coke for pipe earth electrode as required. |
| 3 | [24.1.8]EARTHING AND LIGHTENING ARRESTOR. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. |
| 4 | [24.2.9.3]LT CABLE. Supply and erection of straight through joint (cable jointing kit) 1.1 KV grade complete with required quantity of resin, hardener, plastic mould G.P. Putty, adhesive, earth continuity, connections and fixing the same in position complete with joint etc. - Straight through Joint. For 10 to 16 sqmm Cable 2 Core |
| 5 | [24.2.9.5]LT CABLE. Supply and erection of straight through joint (cable jointing kit) 1.1 KV grade complete with required quantity of resin, hardener, plastic mould G.P. Putty, adhesive, earth continuity, connections and fixing the same in position complete with joint etc. - Straight through Joint. For 25 sqmm to 50 sqmm Cable 3 to 4 Core |
| 6 | [24.5.2.3]MISCELLANEOUS ITEMS. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia |
| 7 | [23.22.1.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc.. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 16 to 100 Amp, 25 KA |
| 8 | [23.22.1.5]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 200 to 250 Amp, 25 KA |
| 9 | [23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole |
| 10 | [23.27.2]Supply and erection of Godrej Almirah typeM.S. pedestal made of 50 mm x 50 mm x 6 mm angle iron frame with 3.00 mm thick M.S. sheet covering including shutters with suitable hinges and locking arrangement with Godrej type handle including round bars . The top covering should have downward overhang of 75 mm on all sides of pedestal , having two sets of water proof ventilation holes of suitable size on the sides , at top and bottom , each set containing four Nos. holes to discharge the heat produced by the current . The shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof . The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embeded upto the entire depth in 1:2:4 cement concrete block , projected 75 mm all around the pedestal and and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work:- 2. M.S. pedestal of size 750 mm wide , 900 mm high , 300 mm deep and bottom totally open , duly embeded in cement concrete block of size 900 mm x 450 mm x 200 mm above ground level , having a base of size 1050 mm x 600 mm x 250 mm below ground level . |
| 11 | [24.13.13]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK. 10 Sq mm 2 core (UnArm.) |
| 12 | [24.13.32]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK . 25 Sq mm 4 core (Arm.) |
| 13 | NS) Repair and Maintenance charges of LED street light / Flood lights points from 90 watt to 200 watt installed on 9 mtr./11 mtr. long PCC /STP poles/High Mast, ON/OFF operation and fault finding of electrical circuits, cost of material charges i.e. Driver/SPD/PCB/ PVC tape roll/screw etc. arranging of T and P i.e. Hydraulic ladder/alum. Ladder, safety belt, safety shoes etc.) on various sectors / master roads complete in all respect up to the entire satisfaction of engineer in charge of work. |
| 14 | NS) Repair and Maintenance charges of LED street light points up to 25 watt installed on 9 mtr./11 mtr. long PCC /STP poles/High Mast, ON/OFF operation and fault finding of electrical circuits, cost of material charges i.e. Driver/SPD/PCB/ PVC tape roll/screw etc. arranging of T and P i.e. Hydraulic ladder/alum. (Ladder, safety belt, safety shoes etc.) on various sectors /master roads complete in all respect up to the entire satisfaction of engineer in charge of work. |
| 15 | NS) Repair and Maintenance charges of LED street light points from 45 watt to 72 watt installed on 9 mtr./11 mtr. long PCC /STP poles/High Mast, ON/OFF operation and fault finding of electrical circuits, cost of material charges i.e. Driver/SPD/PCB/ PVC tape roll/screw etc. arranging of T and P i.e. Hydraulic ladder/alum. Ladder, safety belt, safety shoes etc.) on various sectors / master roads complete in all respect up to the entire satisfaction of engineer in charge of work. |
| 16 | NS) Supply and erection of 2.5 sqmm x 3 core aluminum flexible cable PVC insulated and sheathed core round/flat cable 1100 volts each core having single solid aluminium conductor as per IS: 694, complete in all respect up to entire satisfaction of the Engineer-in-Charge of the work. (Rate without GST)Make:- Havells/Polycab/Grandlay or make approved by DHBVN. |
| 17 | NS) Supply and erection of 25 mm dia G.I. pipe bracket 1.0 mtr long made out of 32mm nominal dia (B-class) suitable for street light fitting including 2 nos. Clamps of M.S. Flat size 50x6mm, 6 nos. Nutt and Bolts of size 50x16mm with application of primer and painting complete in all respect up to the entire satisfaction of Engineer-in-Charge. |
| 18 | NS) Supply and erection of 32 mm dia G.I. pipe bracket 1.0 mtr long made out of 32mm nominal dia (B-class) suitable for street light fitting including 2 nos. Clamps of M.S. Flat size 50x6mm, 6 nos. Nutt and Bolts of size 50x16mm with application of primer and painting complete in all respect up to the entire satisfaction of Engineer-in-Charge. |
| 19 | NS) Supply and erection of 30sqmm PVC insulated ACSR conductor conforming to IS 398 (Part-II) 1976/1996, IS 4826-1976 IS 1521-1972 and IS 1778-1980 with latest amendments and erection of the same with accessories including stringing and sagging of conductor as well as jointing and binding with insulator at supports in all respect up to the entire satisfaction of Engineer-in-Charge. |
| 20 | NS) Supplying, installation, Testing and Commissioning of 25 Watt Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency )85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP- 66,IK-10, CRI )80, under voltage and over voltage protection, EMI- EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin),SDCM(Standard Deviation Color Matching) (5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =105 (120 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). |
| 21 | NS) Supplying, installation, Testing and Commissioning of 72 Watt Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency )85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP- 66,IK-10, CRI )80, under voltage and over voltage protection, EMI- EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin),SDCM(Standard Deviation Color Matching) (5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy = 105 (120 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
TodayBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender