Tender For Electrical Renovation Of Different Laboratories, Office Rooms, Power Supply Arrangement To New Equipments And Other Allied Works At Csir-Immt, Bhubaneswar (Fy: 2026-27)
Tender Value
19.79 Lakhs
Estimated cost
Bid Submission
27 Aug 2026
3 days left
EMD
39599
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Khordha → Odisha
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Electrical Renovation Of Different Laboratories, Office Rooms, Power Supply Arrangement To New Equipments And Other Allied Works At Csir-Immt, Bhubaneswar (Fy: 2026-27)
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq mm ISI marked FRLS PVC insulated single core copper conductor (Finolex/Poly-Cab/RR/KEI make) cable in surface/ recessed PVC conduit medium ( AKG/Kinjal/Polycab/Precision make) with piano type switch, phenolic laminated sheet, suitable size M.S. box incorporated with Neutral & Earth link & earthing the point with 1.5 sq mm green colour FRLS PVC insulated single core copper conductor cable etc as required. Neutral & Earth wire to come to Switch Box along with phase as per wiring system etc. Group – C |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq mm (Finolex/ Poly-Cab/RR / KEI make) ISI marked FRLS PVC insulated single core copper conductor cable in surface/ recessed PVC conduit medium class (AKG/Kinjal/Polycab/Precision make) with modular type 5A switch, modular base & cover plate on suitable size modular type metal box (Legrand myrius /schneider clipsal/anchor woods make) make incorporated with Neutral & Earth link & earthing the point with 1.5 sq mm FRLS PVC insulated single core copper conductor cable etc as required. Group – C |
| 3 | Supply and fixing 5/6 amps. piano type switch (Anchor/Great white/Havells) on the existing switch box/cover including connections etc. as required. |
| 4 | Supply and fixing 15/16 amps. piano type switch (Anchor/Great white/Havells) on the existing switch box/cover including connections etc. as required. |
| 5 | Supply and fixing 5/6 amps. Piano Type Socket (Anchor/Great white/Havells) outlet on the existing switch box/cover including connections etc. as required. |
| 6 | Supply and fixing 15/16 amps. Piano Type Socket outlet (Anchor/Great white/Havells) on the existing switch box/cover including connections etc. as required. |
| 7 | Supply and fixing 5/6 amps.modular type (1 module)switch on the existing modular plate & switch box including connections etc. as required. (Legrand myrius /schneider clipsal/anchor woods) make |
| 8 | Supply and fixing15/16 amps.modular type (1 module) switch on the existing modular plate & switch box including connections etc. as required. (Legrand myrius /schneider clipsal/anchor woods) make |
| 9 | Supply and fixing 5/6 amps.modular type socket (2 module) on the existing modular plate & switch box including connections etc. as required. (Legrand myrius /schneider clipsal/anchor woods) make |
| 10 | Supply and fixing 5 pin, 15/16 amps.modular (2 module) type socket on the existing modular plate & switch box including connections etc. as required. (Legrand myrius /schneider clipsal/anchor woods) make |
| 11 | Supplying and fixing Modular stepped type electronic fan regulator, 2 module, 120W in the existing modular switch box including connection etc as required. Legrand myrius /schneider clipsal/anchor woods make |
| 12 | Supply and fixing of 1 or 2 modules, modular base & cover plate & modular type metal box (GI) on surface or in recess etc. as required. (Legrand myrius /schneider clipsal/anchor woods) make |
| 13 | Supply and fixing of 6 modules, modular base & cover plate & modular type metal box (GI) on surface or in recess etc. as required. (Legrand myrius /schneider clipsal/anchor woods) make |
| 14 | Supply and fixing of 16 modules, modular base & cover plate & modular type metal box (GI) on surface or in recess etc. as required. (Legrand myrius /schneider clipsal/anchor woods) make |
| 15 | Supplying and fixing modular blanking plate(1 mod) on the existing modular plate & switch box excluding modular plate as required. |
| 16 | Supplying and fixing of 5amp ceiling rose on the existing junction box/wooden block including connections etc. as required. |
| 17 | Supply and fixing extra down rod of 20cm length GI pipe , 15mm dia (heavy gauge) including painting etc as required. |
| 18 | Supplying & fixing the louvers/shutters and bird protection net complete with frame, up to size of 380 mm sweep exhaust fans etc as required. |
| 19 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. (Legrand myrius /schneider clipsal/anchor woods) make |
| 20 | Supply and fixing metal box of (180 mm x 100 mm x 60 mm deep) on surface or in recess with suitable size of phenolic laminated sheet cover in the front including painting etc. as required. |
| 21 | Supply and fixing metal box of (200 mm x 300 mm x60 mm deep) on surface or in recess with suitable size of phenolic laminated sheet cover in the front including painting etc. as required. |
| 22 | Supply and fixing metal box of (200 mm x 300 mm x100 mm deep (For AC starter enclosure) on surface or in recess with suitable size of phenolic laminated sheet cover in the front including painting etc. as required. |
| 23 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable Finolex/ Poly-Cab/RR / KEI make) in surface/ recessed medium class PVC conduit (AKG/Kinjal/Polycab/Precision) alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 24 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable Finolex/ Poly-Cab/RR / KEI make) in surface / recessed medium class PVC conduit (AKG/Kinjal/Polycab/Precision) alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 25 | Wiring for light/ power plug with 4X10 sq. mm FRLS PVCinsulated copper conductor single core cable Finolex/ Poly-Cab/RR / KEI make) in surface / recessed medium class PVC conduit (AKG/Kinjal/Polycab/Precision) alongwith 2 Nos. 6 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 26 | Wiring for light/ power plug with 4X16 sq. mm FRLS PVCinsulated copper conductor single core cable(Finolex/ Poly-Cab/RR / KEI make) in surface / recessed medium class PVC conduit (AKG/Kinjal/Polycab/Precision) alongwith 2 Nos. 6 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 27 | Supplying and drawing 3 x 1.5 sq mm of FRLS PVC (Finolex/ Poly-Cab/ RR / KEI make) insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit/ Trunking as required. |
| 28 | Supplying and drawing 3 x 4 sq mm of FRLS PVC (Finolex/ Poly-Cab/ RR / KEI make) insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit/ Trunking as required. |
| 29 | Supplying and drawing 3 x 6 sq mm of FRLS PVC (Finolex/ Poly-Cab/ RR / KEI make) insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit/ Trunking as required. |
| 30 | Supplying and drawing of 2pair 0.5 sqmm FR PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/ recessed steel/ PVC conduit as required |
| 31 | Supplying and fixing of 20 mm dia PVC conduit in surface/recessed PVC conduit medium (AKG/Kinjal/Polycab/Precision) including cutting the wall & making good the same in case of recessed conduit etc. as required. |
| 32 | Supplying and fixing of 25 mm dia PVC conduit in surface/recessed PVC conduit medium (AKG/Kinjal/Polycab/Precision) including cutting the wall & making good the same in case of recessed conduit etc. as required. |
| 33 | Supply & fixing of modular type RJ-11 telephone socket in the existing modular box for telephone connection including connection etc as required. Legrand myrius /schneider clipsal/anchor woods make. |
| 34 | Supplying, Installation, Testing and commissioning of CAT6 Copper Information Outlet (IO) with face plate of color as per site requirement, should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D. All copper Cable and Components should be from same OEM to maintain compatibility and interoperability etc. Complete as required. Legrand myrius /schneider clipsal/anchor woods make |
| 35 | Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required. 1 Run of cable |
| 36 | Supplying and fixing of 8 way, single pole and neutral, sheet steel,double door MCB distribution board, 240 volts, on surface/recess, complete with terminal blocks, duly prewired with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar, hinged gland plate, interconnections,. including painting, earthing etc. as rquired. Legrand/Hager/Siemens/ C &S make |
| 37 | Supplying and fixing of 12 way, single pole and neutral, sheet steel,double door MCB distribution board, 240 volts, on surface/recess, complete with terminal blocks, duly prewired with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar, hinged gland plate, interconnections,. including painting, earthing etc. as rquired. Legrand/Hager/Siemens/ C &S make |
| 38 | Supplying and fixing of 4 (4+12) way, Double Door, three pole and neutral, sheet steel, MCB distribution board , 415 volts, on surface/recess, complete with terminal blocks, duly prewired with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections,. including painting, earthing etc. as rquired. Legrand/Hager/Siemens/ C &S make. |
| 39 | Supplying and fixing of single pole 6 to 32 amps rating, 240 volts MCB (C series) of Legrand/Hager/Siemens/ C &S make in the existing MCB DB complete with connections, testing and commsissioning etc. as requried. |
| 40 | Supplying and fixing 63amp, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. Legrand/Hager/Siemens/ C &S make |
| 41 | Supplying and fixing 63amp, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. Legrand/Hager/Siemens/ C &S make |
| 42 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 32 A, 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. Legrand/Hager/Siemens/ C &S make |
| 43 | Supplying and fixing FP sheet steel enclosure on surface/ recess along with 32 A, 415 V \\"C\\" curve FP MCB complete with connections, testing and commissioning etc. as required. Legrand/Hager/Siemens/ C &S make |
| 44 | Supplying and fixing 20 amps, 240 volts, SPN, industrial type socket outlet, with 2 pole and earth metal enclosed plug top alongwith 20 amps. C-series, SP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet, and complete with connections, testing and commissioning etc. as required. Legrand/Hager/Siemens/ C &S make |
| 45 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 46 | Providing and fixing 25mm x 5mm GI strip in 40 mm dia GI pipe from earth electrode including connection with G.I. nut, bolt, spring, washer exacavation and re-filling etc. as required |
| 47 | Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required. |
| 48 | Providing and fixing 4 mm dia copper wire on surface or in recess or in existing pipe along with existing cable for loop earthing etc as required. |
| 49 | Supplying and making end termination with brass compression gland and aluminium lugs for 3.5 core x 70 sq mm size of PVC insulated armoured and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 50 | Supplying and making end termination with brass compression gland and aluminium lugs for 4 core x 10 sq mm size of PVC insulated armoured and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 51 | Supply and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for 3.5 core x 25 sq mm or 3.5 core x 35 sq mm or 3.5 core x 50 sq mm of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 52 | Supply and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for 3.5 core x 70 sq mm sq mm of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 53 | Supply and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for 3.5 core x 120 sq mm or 3.5 core x 150 sq mm or 3.5 core x 185 sq mm of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 54 | Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of street light fitting including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. |
| 55 | Supplying and laying of 63 mm dia (OD-63 mm & ID-51 mm nominal) size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930/IS 16205, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 56 | Laying of one number PVC insulated and PVC sheathed / XLPE aluminium power cable of 1.1 KV grade of 3 core x 6 sq mm size in the existing masonry open duct/ DWC pipe as required. |
| 57 | Laying of one number PVC insulated and PVC sheathed / XLPE aluminium power cable of 1.1 KV grade of 4 core x 10 sq mm size in the existing masonry open duct/ DWC pipe as required. |
| 58 | Laying of one number PVC insulated and PVC sheathed / XLPE aluminium power cable of 1.1 KV grade of 3.5 core x 70 sq mm size in the existing masonry open duct/ DWC pipe as required. |
| 59 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 4 core x 10 sq mm size (clamped with 1mm thick saddle) on wall surface as required. |
| 60 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) (Havells / Crompton / Atomberg or similar model as approved by dept) |
| 61 | S/I/T/C of LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt ) Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim (22 watt) |
| 62 | S/I/T/C of LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt ) Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim (30 watt) |
| 63 | S/I/T/C of LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) (36 Watt) |
| 64 | S/I/T/C of LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 72 Watt |
| 65 | S/I/T/C of LED Batten light (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 18-22 watt |
| 66 | S/I/T/C of LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 100 watt |
| 67 | Supplying, installation, testing and commissioning of indoor type wall surface electrical panel made out of 2 mm thickness of metallic sheet steel of tentative panel size 0.6mtr height & 0.3 mtr width (or as approved), including supplying, installation & internal wiring of following mountings complete as required, duly acid treated for derusting, primered and painted with powder coating of approved shade as per engineer in charge. (Manufacturing will be done only in CPRI approved factories)a) Incommer:- One number 125 A, 36KA, FPMCCB with rotary handle SIEMENS / L & K / C & S/ Legrand makeb) One number bus-bar chamber comprising four strips (20 mm x 5 mm or equivalent, 100% neutral ) copper bus-bar of suitable length mounted on insulator etc as required |
| 68 | Supplying, installation, testing and commssioning of 400 mm sweep pedastal fan (metal body) with inbuilt regulator of Havells /Crompton / Almonard make |
| 69 | Supplying, installation, testing and commssioning of 400 mm sweep wall fan with inbuilt regulator of Havells /Crompton / Almonard make |
| 70 | Supplying, installation, of Heavy Duty exhaust fan of 380 mm sweep of ( Almonard / Havells/ Crompton make) in the existinge wall, including making the damage good, connection, testing, commissioning etc as required. |
| 71 | Supplying, installation, of light duty exhaust fan of 250 mm sweep, PVC body , (Almonard / Havells /Crompton make ) in the existinge wall, including making the damage good, connection, testing, commissioning etc as required. |
| 72 | Supplying, installation, of Heavy duty exhaust fan of 300 mm sweep , (Almonard / Havells /Crompton make ) in the existinge wall, including making the damage good, connection, testing, commissioning etc as required. |
| 73 | Supplying & installation, testing and commissioning of prewired baten fitting/LED channel (box type) suitable for two numbers LED tube light of (Philips / Klite as approved) with all accessories and 2 nos 2000 lumen led tube etc. directly on wall including connections with 1.5 sq mm PVC insulated, copper conductor, single core cable etc.as required. |
| 74 | Supplying and fixing of 3 mm thick phenolic laminated sheet including cutting for switch, socket etc. on the existing metal switch board etc as required. |
| 75 | Supplying and fixing FP sheet steel enclosure on surface/ recess complete with connections, testing and commissioning etc. as required. Legrand/Hager/Siemens/ C &S make |
| 76 | Supplying and fixing 63 amp, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. Legrand/Hager/Siemens/ C &S make |
| 77 | Supplying and installation of starter for Air-conditioner, 3-phase DOL starter L&K /Siemens/ C &S make, coil voltage-230 ,Volt 50HZ. & O/L range 9-14 Amps on existing M.S. Box, etc as required . |
| 78 | Supplying and fixing Flush type Rotary Step 120/280 volt Fan regulator on the existing switch box/cover including connection etc as required. Anchor/Great white/Havells make. |
| 79 | Supplying of one number PVC / XLPE insulated armoured and PVC sheathed AL. conductor power cable of 1.1 KV grade (POLYCAB / Finolex / KEI / RR make) armoured cable as approved by dept. Engg. of 3 core x 6 sq mm size in the open duct / existing trench /pipe etc. as required. |
| 80 | Supplying of one number PVC / XLPE insulated armoured and PVC sheathed AL. conductor power cable of 1.1 KV grade (POLYCAB / Finolex / KEI / RR make) armoured cable as approved by dept. Engg. of 4 core x 10 sq mm size in the open duct / existing trench /pipe etc. as required. |
| 81 | Supplying of one number PVC / XLPE insulated armoured and PVC sheathed AL. conductor power cable of 1.1 KV grade (POLYCAB / Finolex / KEI / RR make) armoured cable as approved by dept. Engg. of 3.5 core x 70 sq mm size in the open duct / existing trench /pipe etc. as required. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 20, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysAug 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender