Defence Government Departments Closing in 5 days TDR #57110622

Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Onboard Ins Teg At Naval Dockyard Mumbai; Repair/Refurbishment And Stw Of Burya Control System Onboard Ins Teg; Service Provider - Service - Phase -

Issued by Government Departments · Mumbai, Maharashtra
Tender Value
Ref. Documents
Estimated cost
Bid Submission
27 Aug 2026
5 days left
EMD
38.34 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Mumbai → Maharashtra
EMD Exemption
Not Available
Quantity
1

Project Description

Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Onboard Ins Teg At Naval Dockyard Mumbai; Repair/Refurbishment And Stw Of Burya Control System Onboard Ins Teg; Service Provider - Service - Phase -I - Diagnostic Survey Of Burya Control System Undertake Detailed Defect Survey Of Onboard Equipment Of System ‘Burya I.E. All Panels ,Ups, Scd,Lts, Tld Devices Jbs, Sensors And Cables Etc. To Finalise Scope/ Quantum Of Repair And Mr Maintenance Services. , Services - Phase –Ii - Burya Control System: Degutting Of Control Cables Connected From Gt/Rg To The Foundation Frame And Cables Coming From Devices And Equipments To The Frame And Preserves Them Safely For Re-Use. , Services - Degutting Of All Panels, Units/Devices, Tlds, Jbs And Sensors Etc. Required For Providing Clear Passage To Remove Gas Turbine And Rg. , Services - Undertake All Maintops & Oem Prescribed Mr Routines On Devices And Control Panels Of System. , Services - Carry Out External Inspection Of All Devices And Jbs. Undertake Cleaning, Degreasing. Renew All Missing / Corroded Fasteners. , Services - Renew All Earthing Strips. Clean And Polish All Contact Surfaces. , Services - Examine All Shock Mounts Of Units. Renew The Defective Mounts, If Any With Equivalents , Services - Inspect All Jbs For Corrosion And Damage Gasket, Change If Required. Inspect Condition Of Cables And Cable Connections. Clean Internally And Renew Connections, Ferules And Defective Lugs. , Services - Inspect All Cable Connectors. Carryout Internal Cleaning And Decarbonisation Of Connectors. Polish All Pins And Mating Surfaces. Inspect Earthing Of Cable Screen. Repair/ Replace Defective Screen. , Services - Undertake Internal Inspection Of All Devices And Equipment Of The System. Remove All Modules/Pcbs. Carry Out Extensive Cleaning Of Internal Parts From Dust, Corrosion And Oxide Formations. Remove All Foreign Material Using Vacuum Cleaner/ Magnets. Renew All Fasteners / Securing Screws. , Services - Inspect All Internal Cabling And Patch Chords For Wear, Tear And Deterioration Of Insulation. Renew / Repair The Defective Patch Chords. , Services - Inspect All Fuses Including Spare Fuses Renew With Correct Rating. , Services - Survey Of All Modular Switches, Hooters Dimmers, Alarms & Indications L S Etc. On Mcr Control Panels And Ecr Control Panel. Replace Defective Parts. Ss To Supply Material. , Services - Examine Material State Of Key Boards, Mouse And Other Elements Of Data Input. Renew Defective Parts. Ss To Supply Spares. , Services - Carry Out Serviceability Checks Of All Command And Indication Channels Of Interface. , Services - Check Serviceability Of All Input And Output Telemetric Channels As Per Document Дaиe 421455.128-01 , Services - Check Communication Between Mcr And Ecr Of Burya Panel, Port And Stdbd Section In Ecr And All Other Section In Mcr. Repair If Not Working. , Services - Carry Out Insulation Checks Of System As Per Prescribed Procedures. Improve Insulation If Not Within Prescribed Limits. Record Final Values. , Services - Examine And Undertake Refurbishment/Replacement Of Cabling Internal To Jbs/ Control Panel Etc. As Required. , Services - Repairs & Maintenance Routines Of Instrumentation Of Cgts (Fer): Carry Out Serviceability Checks / In-Situ Calibration Of All Interfaced Sensors. Replace Defective Sensors. Ss To Supply New Sensor In Lieu Of Defective Sensor. List Of Sensors Recommended For Procurement/Replacement Is Given In Part B Of Scope Of Work. , Services - Repairs & Maintenance Routines Of Instrumentation Of Bgts (Aer): Carry Out Serviceability Checks / In-Situ Calibration Of All Interfaced Sensors. Replace Defective Sensors. Ss To Supply New Sensor In Lieu Of Defective Sensor. List Of Sensors Recommended For Procurement/Replacement Is Given In Part B Of Scope Of Work. , Services - Routines On Ups Of Burya System Undertake All Maintops & Oem Prescribed Mr Routines On Ups Devices. , Services - Carry Out Visual Inspection Of All Devices. , Services - Inspect And Repairs/Replace All Defective Mechanical Fixtures (Hinges, Locks, Bolts, Screws, Guide Rails, Commutation Connectors Etc.) , Services - Survey All Fuses & Indications L S Etc. On Ups Fitted In Mcr And Ecr. Replace All Defective Units With New. , Services - Renew All Earthing Strips. Clean And Polish All Mating Surfaces. , Services - Examine All Shock Mounts Of Units. Renew Defective Mounts If Found. , Services - Carry Out Inspection Of All Internal Connections For Wear & Tear. Renew Defective Internal Cabling And Connectors. , Services - Check Availability Of Main And Reserve Power Supply On Module Mфф And Repair If Defective. , Services - Check Insulation Of Ups Device With Respect To Earth As Per Technical Description And Operating Instructions. , Services - Remove All Modules And Pcbs To Electronic Lab. And Undertake Following: -I) Carry Out Routines On All Electronic Circuitry.Ii) Carry Out Decarbonisation Of All Modules And Pcbs.Iii) Carry Out Refurbishment Of Modules And Power Supply Devices.Iv) Check Correctness Of Ratings Of All Fuses Assemblies.V) Check Functioning Of All L S And Indications.Vi) Carry Out Polishing Of All Contacts And Mating Surfaces.Vii) Renew Conformal Coating Of Modules /Pcbs As Applicable.Viii) Check Serviceability Of Units For Which Test Facility Exists At The Lab.(Ix) Carry Out Load Test On Power Supply Modules. , Services - Check Condition Of Batteries In Unit Maƃ. Discharge The Batteries By Switching On The Associated System & Put On Charge, If The Batteries Are Not Used For Prolonged Duration. Carry Out Capacity Test Of Battery And Renew Battery Bank If Capacity Less Than 80 %. Ss To Supply New Batteries. , Services - Check Serviceability Of Mk3б. Modules As Per Technical Manual By Selecting Battery Supply And Check Output Of Battery On Modules Mk3б. With And Without Load. , Services - Check L S/Leds And Holders For Correct Operation. Replace Defective L S/Leds And L Holders. , Services - Check Tightness Of Connectors, Cable Glands And Internal/ External Cable Connections. , Services - Check Normal And Battery Modes Of Operation. , Services - Check Correct Functioning Of Over Load Mode For Mфф Unit. , Services - Carry Out Serviceability Checks Of All Modular Switches On Operators Panel. Repair/ Renew Non-Functional Switches. , Services - Check Ventilation Openings Of The Ups And Clean With Brush. , Services - Check Securing Arrangement Of All Modules. Renew All Missing Screws. , Services - Check Alignment Of Guiding Pins And Connector Pins. Inspect Connectors For Any Bend /Damaged Pins. Replace With New As Necessary. , Services - Open And Inspect All Cable Connectors Of Devices. Inspect For Loose Material Particles, Breakages Of Contact Etc. Inspect Cable For Intactness Of All Earthing / Grounding Of Metallic Sleeves. Fit Back The Connectors After Decarbonisation Of Male And Female Connectors. , Services - Check Serviceability And Condition Of Cables And Connectors Inter Connecting Devices And Improve Insulation If Found Below Acceptable Limits, Especially Degutted Cables And Cables In Engine Room. , Services - Inspect Internal Wiring Of Units. Check Intactness Of All Connectors And Internal Cabling. Repair/ Renew Defectivecables/Connector If Any. , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work- Installation/ Re-Gutting Of All Panels, Devices, Jbs And Sensors Etc. On Proper Foundation After New Gt And Rg Is Installed On The Foundation. , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work- Secure All The Cables With Cl S, Degutted For Replacement Of Gt And Rg. Carry Out Routine On The Cables And De- Carbonisation Of Connectors, Replace Worn Out Shielding/Screen And Cable Lugs Etc. , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work- Remove And Land Meter And Gauges To Meci For Calibrations. Re-Fitment Of All Meter And Gauges Post Calibrations And Checks Serviceability. (Approx. Qty.50 Nos) , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work- Checks Serviceability Of Mcr Control Console & Replace Perished Wires, Defective Indications L S. , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work- Checks Serviceability Of Ecr Control Console & Replace Perished Wires ,Defective Indications L S. , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work- Check And Prove Ethernet Lan Network Protocol Between Mcr Console And Ecr Console. Replace Cable, If Required. , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work- Check Serviceability Of Local Technological Stations(Lts) In Fwd & Aft Engine Room And Rectify Defect If Any.(Qty.04 Nos) , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work- Check Integrity Of Serial Communication Link Rs232 & Rs485 Protocol For Interfacing. , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work- Check Integrity Of Mil-Std 1553B Communication Link Protocol Between Lts To Mcr Console & Lts To Ecr Console. , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work- Carry Out Serviceability Checks Of Servo Control Device. Undertake Tunning If Required. , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work- Carry Out Serviceability Checks Of Burya Printer And Rectify Defect If Any. , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work- Carry Out Insulations Checks Of Burya Control System & Rectify If Not Within Prescribed Limit. , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work- Carry Out Power Supply Checks For Burya Control Supply From Fwd & Aft Switch Boards And Rectify Defect If Any. , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work- Rectify All Known Defects Projected By Yard/Ss. List Place At Enclosure. , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work- Offer System For Gttt (Mbi) Stage Inspections. Rectify All Observations. , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work- Check Serviceability Of Ups Units. Carry Out Repairs /Refurbishment Of Modules. Replace Defective Modules If Any Ss To Supply Modules. , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work- Check And Prove Battery Supply Back Up Timing As Per Document. , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work- Switch On Power Supply And Check Serviceability And Correct Functioning Of Modules And Displays. Repair/Rectify Defect If Not Working. , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work- Switch ‘On Main And Reserve Power Supplies To System And Check For Smooth Change Over. , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work- Undertake Complete Functional Checks And Proving Of System Including All Telemetric Channels And Interfaces With Other System. , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work- Check And Correct Software Versions Of System Spare Modules. , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work- Carry Out Setting To Work And Testing & Tuning Including Tuning Of Software Based On Present Status, As Required) Of Burya Control System (As Per Oem Protocol Document. , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work-Carry Out Rectification Of All Observations During (Stw) Of All Units. , Services - Phase –Iv - Burya Control System – Harbour Trials And Sea Trials In Full Scope (As Per Oem Document). , Services - Phase-I Diagnostic Survey Zorya Control System : - Undertake Detailed Defect Survey Of Onboard Equipment Of System Local Control System Of Gts & Rgs I.E All Control Stations, Devices Jbs And Sensors. Etc. Finalise Scope/ Quantum Of Repair And Mr Maintenance Services , Services - Phase –Ii Repairs & Maintenance Routines Zorya Control System : Degutting Of Control Cables Connected From Gt/Rg To The Foundation Frame And Cables Coming From Devices And Equipments To The Frame And Preserves Them Safely For Re-Use. , Services - Degutting Of All Gts Frame Connectors, Cables, Jbs And Sensors Etc. Required For Providing Clear Passage To Remove Gas Turbine And Rg. , Services - Undertake All Maintop/ Oem Prescribed Mr Routines On System. , Services - Carry Out External Inspection Of All Devices And Jbs. Rectify All Mechanical Defects. Undertake Cleaning, Degreasing. Renew All Missing / Corroded Fasteners. , Services - Renew All Earthing Strips. Clean And Polish All Contact Surfaces. , Services - Examine All Shock Mounts Of Units. Renew With Equivalents As Necessary. , Services - Inspect All Jbs For Corrosion. Inspect Condition Of Cables And Cable Connections. Clean Internally And Renew Connections And Ferules As Required. , Services - Inspect All Cable Connectors. Carry Out Cleaning And Decarbonisation Of Connectors. Polish All Pins And Mating Surfaces. Inspect Earthing/Cable Screen. Repair Re-Solder As Necessary. , Services - Undertake Internal Inspection Of All Devices And Equipment Of The System. Remove All Modules /Pcbs. Carry Out Extensive Cleaning Of Internal Parts From Dust, Corrosion And Oxide Formations. Remove All Foreign Material Using Vacuum Cleaner/ Magnets. Renew All Fasteners / Securing Screws. , Services - Inspect All Internal Cabling For Wear, Tear And Deterioration Of Insulation. Renew / Repair As Required. , Services - Inspect All Fuses Including Spare Fuses Renew With Correct Rating. , Services - Remove & Land Of All Modules To Lab. Carry Out Decarbonisation Of Modules. Carry Out Detailed Inspection And Undertake Refurbishment Of Modules. On Completion Carry Out Functional Tests Of Modules. Inspect Connectors. Replace As Necessary. Decarbonise And Polish All Pins And Mating Surfaces. Carry Out Renewal Of Conformal Coating Of Modules, As Applicable. , Services - Check Insulation Resistance Of Convertors Circuit Used For Thermo Electric Measurement Of Gt Outlet Gas Temp Across The Thermal Junction Boxes Of Txa-1368. , Services - Open Miii Type Connectors Of Gt Control Station All Electrical Equipments, Decarbonise And Wipe Out With The Help Of Alcohol And Calico Cloth. , Services - Check Condition Of Plasma Ignition Unit In Accordance With The Manual. Check Condition Of Control Pcb , Capacitor Banks And Connectors. Clean Contacts With Brush And Alcohol. , Services -Maintenance Routines And Replacement Of Brushes Of Шпm Current Collector Assembly For Port & Stbd Shaft, If Required. , Services - Check And Prove Air Flux Clutching Mechanism Of Boost Gas Turbine , Services - Carry Out Insulation Test And Continuity Test Of Cables Of All Electrical Devices, Sub Devices And Sensors Associated With Zorya Control System As Required Vide Maint. Documents. Improve Insulation If Not Within Limits. , Services - Fitment Of All Slotted And Magnetic Chip Detectors Of Both Cgt And Bgt (Qty. 24 Nos.). Insulation Test And Continuity Test Of Cables Connected To All Slotted And Magnetic Chip Detectors Kcccm And Cc Of All Four Gts. Check Condition Of Cables And Replace Cables. , Services - Check Serviceability Of Бисс, Бусс And Бср Units. Repair/Refurbishment Of Units As Required. , Services - Check Serviceability Of Spark Plugs, Spark Plug Cables And Plasma Ignition Units Of Both Cgt And Bgt. Fitment Of Spark Plugs, Spark Plug Cables And Plasma Ignition Units Of Pcgt And Scgt. Check Condition Of Cables. , Services - Carry Out Insulation Test, And Continuity Test Of Supply And Control Cables Connected With Plasma Ignition Unit Of All Four Gts. Check Condition Of Cables , Services - Check Serviceability Of Длпг, Дпна1, Дпна2, Дтп1, Дтп2, Кпв, Кпф And Transducers And Valves. Repair/Refurbishment Or Replacement Of Transducers And Valves As Required. Transducer And Valves To Be Provided By Ss. , Services - Carry Out Insulation Test, Continuity Test And Connection Of Cables With Gt Control Station (Via Kcaл Connection Box) Of Длпг, Дпна1, Дпна2, Дтп1, Дтп2, Кпв, Кпф And Кзот Transducers And Valves. Check Condition Of Cable. , Services -Check Serviceability Of Дсо Transducer (Свм-Д) And Connection Of Transducer With Synchronizer Cbm-4. Check Condition Of Cables , Services - Check Serviceability Of Дмд, Дмд1, Дтаз, Кас, Кпт, Mck And Mct Units And Transducers. Fitment Of Дмд, Дмд1, Дтаз, Кас, Кпт, Mck And Mct Units And Transducers Of Both Cgts. Repair/Refurbish Transducers/Units. Ss To Provide New Transducers In Lieu Of Defective Ones For Replacement. , Services - Carry Out Insulation Test, Continuity Test And Connection Of Cables With Gt Control Station (Via Ксап) Of Дмд, Дмд1, Дтаз, Кас, Кпт, Mck And Mct Units And Transducers. Check Condition Of Cables. , Services - Carry Out Insulation Test, Continuity Test And Connection Of Cables From Connection Boxes Kcaл And Ксап To Gt Control Station. Check Condition Of Cables. , Services - Check Serviceability Of Пкц Unit Of All Four Gts And Connection Of Unit With Gt Control Station. Check Condition Of Cables. , Services - Fitment Of Kcpt Connector Of Cgts. Check Insulation Test, Continuity Test And Connection Of Cables From Kcpt Connection Box To Gt Control Station. Check Condition Of Cables. , Services - Check Serviceability Of Взх, Впх, Дсв, Кнзх, Ксзх, Кнпх, Кспх, Khcb And Kccb Micro-Switches And Manipulators. Connection Of All Micro-Switches And Manipulators With Gt Control Station (Via Kcpt Connection Box). Check Condition Of Cables. , Services - Fitment Of Кс429 Box Of Both Cgts. Insulation Test, Continuity Test And Connection Of Cables From Хтп Connector To Кстп Box, Кстп Box To Lts And Кстп Box To Рти Unit Of All Four Gts. Check Condition Of Cables. , Services - Carry Out Insulation Test, Continuity Test And Check Connection Of Cables From Рти Unit Gt Control Station And 127 V Db. Check Condition Of Cables. , Services - Check Serviceability Of Дорт Sensor. Carry Out Insulation Test, Continuity Test And Connection Of Cables From Sensor To The Opt Unit Via Ксдорт Connector For Both Cgt And Bgt. Check Condition Of Cables. , Services - Check Serviceability Of Opt Units (Qty- 04) And Connection Of Opt Unit With Gt Control Station, Дорт Sensor. Check Condition Of Cables. , Services - Check Serviceability And Fitment Of Rtds (Тсп 8040-5Ц.2821439-01) Of Тсд, Тсмод, Tcmop, Тскнд, Тсквд, Tctb, And Тстнд Of Both Cgt And Bgt. Carry Out Insulation Test, Continuity Test And Connection Of Cables Of All Rtds With Lts. Check Condition Of Cables. , Services - Fitment Of Kcao Connection Box Of Both Cgts And Connection Of Kcao With Associated Zorya Units I.E Altivar, Бисс, Бpr, Пк, Бвртпн And Gt Control Station. Check Condition Of Cables. , Services - Check Connection Of Cables From Gt Control Station To 27V Db, Lts, Rg Control Station, Kcao, Пкц, Хдсо, Ксап, Kcpt, Рти And Opt Units Check Condition Of Cables , Services - Carry Out Insulation Test, Continuity Test And Connection Of Cables Of All Four Gt Control Stations. Check Condition Of Cables. , Services - Check Serviceability Of Ignition Switches Of Both Cgt And Bgt And Insulation Test, Continuity Test And Connection Of Cables From Ignition Switch To Gt Control Station. Check Condition Of Cables. , Services - Fitment Of Connection Boxes Ям (Ся72-22 O/N), 1Kpm, 2Kpm (Ся42-20 O/N), Яп (Ся72- 22 O/N) Of Both Crgs At Designated Locations. Check Condition Of Cables. , Services - Check Serviceability And Fitment Of Тсг (Air Inlet) And Тсп (Gt Casing) Thermocouples (Txa 1172.5Ц2.821.679-6601) Of All Four Gts. Insulation Test, Continuity Test And Connection Of Cables Of Both Thermocouples To Respective Lts. Check Condition Of Cables. , Services - Check Serviceability And Fitment Of 1Bbk, 2Bbk, Ввпу, Впт, 1Bok And 2Bok Micro Switches Of Both Crgs. Carry Out Insulation Test, Continuity Test And Connection Of Cables From All Micro Switches To Ям Connection Box. Check Condition Of Cables. , Services - Check Serviceability And Fitment Of Oil Pressure Sensors (Дмр) Of Both Crgs (Qty- 08). Insulation Test, Continuity Test And Connection Of Cables From All Sensors To Ям Connection Box Of Crgs And Brgs. Check Condition Of Cables. , Services - Check Serviceability And Fitment Of Дот1, Дот2, 1Дс1, 1Дс2, 2Дс1, 2Дс2,1Дсв, 2Дсв And 2Дсш Transducers Of Both Crgs. Insulation Test, Continuity Test And Connection Of Cables From All Transducers To Respective Cbm Units. Check Condition Of Cables. , Services - Check Serviceability And Fitment Of 1Ддк, 2Ддк, 1Ддф, 2Ддф Transducers Of Both Crgs. Insulation Test, Continuity Test And Connection Of Cables From All Transducers To Ям Connection Box. Check Condition Of Cables. , Services - Check Serviceability And Fitment Of 1Kbk, 2Kbk, 1Kok, 2Kok, 1 Кф And 2Кфem Valves Of Both Crgs. Carry Out Insulation Test, Continuity Test And Connection Of Cables From All Em Valves To Ям Connection Boxes Of All Four Gts. Check Condition Of Cables. , Services - Carry Out Insulation Test, Continuity Test And Check Connection Of Cables From Ям Connection Box To Crg And Brg Control Stations. Check Condition Of Cables. , Services- Carry Out Insulation Test, Continuity Test And Connection Of Cables From All Cbm Units To Crg, Brg And Crga Control Stations Including Relay Units. Check Condition Of Cables. , Services- Check Serviceability And Fitment Of Дот1 And Дот2 Sensors. Carry Out Insulation Test, Continuity Test And Connection Of Cables From Sensors To Respective Пчу And Lts Units. Check Condition Of Cables. , Services- Carry Out Insulation Test, Continuity Test And Connection Of Cables Of All Пчу Units With All Four Gt And Rg Control Stations. Check Condition Of Cables. , Services- Fitment Of 1Kpm And 2Kpm Connection Boxes Of Both Crgs To Designated Locations. Carry Out Insulation Test, Continuity Test And Connection Of Cables Of 1Kpm And 2Kpm With Lts. Check Condition Of Cables. , Services- Check Serviceability And Fitment Of 1Tpm To 24 Tpm Rtds Of Both Crgs And Carry Out Insulation Test, Continuity Test And Connection Of Cables From Rtds To 1Kpm And 2Kpm Connection Boxes. Check Condition Of Cables. , Services- Check Serviceability Of Ввкп, Вокп, Ддкп, Ддфп, Кокп, Bbkл, Bokл, Ддфл, Кокл And Квкл Micro Switches Of Crga. Carry Out Insulation Test, Continuity Test And Check Connection Of Cables Of All Micro Switches And Em Valves With The Яп Connection Box. Check Condition Of Cables. , Services- Carry Out Insulation Test, Continuity Test And Connection Of Cables From Яп Connection Box To Crga Control Station. , Services- Check Serviceability And Fitment Of 1Дсв And 2Дсв Transducers. Carry Out Insulation Test, Continuity Test And Connection Of Cables Of Transducers To Cbm3 Unit. Check Condition Of Cables. , Services- Secure All The Cables With Cl S, Degutted For Replacement Of Gt And Rg. Carry Out Routine On The Cables And De- Carbonisation Of Connectors, Replace Worn Out Shielding/Screen And Cable Lugs. , Services- Repair All Known Defects Projected By Yard/Ss. , Services- Check Serviceability And Fitment Of Synchronizer Units (Qty- 08). Carry Out Repair/Refurbishment Of Units. , Services- Check Serviceability Of Рти Units (Qty- 04). Carry Out Repair/Refurbishment Of Pcbs And Unit. , Services- Serviceability Checks And Calibration Of All Mctb And Сду Type Sensors Of All Four Gts. Repair/Refurbish/Replace The Defective Sensors. Sensors To Be Provided By Ss. , Services- Serviceability Checks /Calibration Of 1Дмр Transducer, Впр Micro Switch, Rtds 13Тф To 22 Тф, Rtds 25Тф To Зотф, Kbш And Koш Em Valves. Repair/Refurbish/Replace The Defective Transducers/Em Valves. Spares To Be Provided By Ss. , Services- Check Serviceability Of Pressure Relay Крд2 (Рд) Of Gt And Rg (Qty- 08). Repair/Refurbishment The Units. , Services- Check Serviceability Of Тп1 Toтп10 Thermocouples (Txa 1368 Type). (Qty- 40 Nos.) , Services - Phase –Iii - Setting To Work Of Gt Local Control System Zorya Control System : Installation/ Re-Gutting Of All Control Stations, Jbs And Sensors Etc. On Proper Foundation After New Gt And Rg Is Installed On The Foundation. , Services- Carry Out Insulation Checks On Zorya System Devices, Gtcs, Rgcs, Etc. And Improve It If Found Low. , Services- Switch Ón Main And Reserve Power Supplies To System And Check For Smooth Change Over. Rectify Defects. , Services- Carry Out Setting To Work And Testing & Tuning Of Zorya Control System (As Per Oem Protocol Document) , Services- Undertake Complete Throttle Checks And Throttle Timing Checks On Both Mode I.E In Normal Mode & Emm Mode. , Services- Undertake Complete Functional Checks Of Gt Control Station (Ƃp-Relay Block). , Services- Check The Interlocks Of Cgt And Bgt. Check Condition Of Cables And Replaced As Required. Interlock Details Are As Follows: -I) Lpc/Hpc Rpm Less Than 300/500 Rpm.Ii)Intake Door Open.Iii) Main And Reserve Control Supply On.Iv) Ptn Switched On. V) Shaft And Pt Turning Device Off.Vi) Starter Supply On.Vii) Throttle Handle In Ir Position.Viii) Stop Cock Closed.Ix) No Protection In Gt/Rg.X) Selections Switch In Start Position. , Services- Check The Cold And Hot Protection Checks Of Cgt And Bgt As Per Maintenance Card. List Of Protection Appended Below: -I) Pt Over Speed Protection.Ii) Lpc Over Speed Protectioniii) High Exhaust Gas Temperature Protectioniv) Low Fuel Pressure Protection.V) Low Oil Pressure Protection Of Gt And Rg.Vi) Bypass Band Protection.Vii) Шпm Pressure Protection. , Services- Undertake Proving Of Interfaces Pertaining To Telemetric Channel Including Necessary Adjustments As Required. , Services- Carry Out Rectification Of All Observations During (Stw) Of All Units And Proving Of Zorya Control System , Services- Phase - Iv:- Zorya Control System: Harbour Acceptance Trials And Sea Acceptance Trials In Full Scope (As Per Oem Document).Acceptance Trials And Sea Acceptance Trials In Full Scope (As Per Oem Document). , Material- Pressure Sensor (Sensor Type Эда-1.6 Kgf/Cm²-01.C Class 0.5 ) , Material- Level Indicator (Sensor Type Уксу-67-0680-Φ25-Н-С-0-T1) , Material- Point Level Alarm (Sensor Type- Ftl51-D B82 Bb 5 Y9 A (L=700) , Material- Point Level Alarm (Sensor Type- Ftl51-D Gr2 Db 5 Y9 A (L=118)) , Material- Rtd (Sensor Type- Тсп/1-8040 Вп 001-01 ) , Material- Rtd (Sensor Type- Тсп/1-8040 Вп 004-47) , Material- Rtd (Sensor Type- Тсп/1-8040 Вп 001-37) , Material- Rtd (Sensor Type- Тсп/1-8040 Вп 001-46) , Material- Rtd (Sensor- Тсп/1-8040 Вп 003-08)

BOQ

Sl. No. Item TitleItem Description
1Service - Phase -I - DIAGNOSTIC SURVEY OF BURYA CONTROL SYSTEM Undertake detailed defect survey of onboard equipment of system ‘Burya’ i.e. all panels ,UPS, SCD,LTS, TLD devices JBs, sensors and cables etc. to finalise scope/ quantum of repair and MR maintenance Services.Service - Phase -I - DIAGNOSTIC SURVEY OF BURYA CONTROL SYSTEM Undertake detailed defect survey of onboard equipment of system ‘Burya’ i.e. all panels ,UPS, SCD,LTS, TLD devices JBs, sensors and cables etc. to finalise scope/ quantum of repair and MR maintenance Services.
2Services - PHASE –II - Burya Control System: Degutting of control cables connected from GT/RG to the foundation frame and cables coming from devices and equipment’s to the frame and preserves them safely for re-use.Services - PHASE –II - Burya Control System: Degutting of control cables connected from GT/RG to the foundation frame and cables coming from devices and equipment’s to the frame and preserves them safely for re-use.
3Services - Degutting of all panels, units/Devices, TLD’s, Jbs and sensors etc. Required for providing clear passage to remove Gas Turbine and RG.Services - Degutting of all panels, units/Devices, TLD’s, Jbs and sensors etc. Required for providing clear passage to remove Gas Turbine and RG.
4Services - Undertake all MAINTOPs & OEM prescribed MR routines on devices and control panels of System.Services - Undertake all MAINTOPs & OEM prescribed MR routines on devices and control panels of System.
5Services - Carry out external inspection of all devices and JBs. Undertake cleaning, degreasing. Renew all missing / corroded fasteners.Services - Carry out external inspection of all devices and JBs. Undertake cleaning, degreasing. Renew all missing / corroded fasteners.
6Services - Renew all earthing strips. Clean and polish all contact surfaces.Services - Renew all earthing strips. Clean and polish all contact surfaces.
7Services - Examine all shock mounts of Units. Renew the defective mounts, if any with equivalentsServices - Examine all shock mounts of Units. Renew the defective mounts, if any with equivalents
8Services - Inspect all JBs for corrosion and Damage gasket, change if required. Inspect condition of cables and cable connections. Clean internally and renew connections, ferules and defective lugs.Services - Inspect all JBs for corrosion and Damage gasket, change if required. Inspect condition of cables and cable connections. Clean internally and renew connections, ferules and defective lugs.
9Services - Inspect all cable connectors. Carryout internal cleaning and decarbonisation of connectors. Polish all pins and mating surfaces. Inspect earthing of cable screen. Repair/ replace defective screen.Services - Inspect all cable connectors. Carryout internal cleaning and decarbonisation of connectors. Polish all pins and mating surfaces. Inspect earthing of cable screen. Repair/ replace defective screen.
10Services - Undertake internal inspection of all devices and equipment of the system. Remove all modules/PCBs. Carry out extensive cleaning of internal parts from dust, corrosion and oxide formations. Remove all foreign material using vacuum cleaner/ magnets. Renew all fasteners / securing screws.Services - Undertake internal inspection of all devices and equipment of the system. Remove all modules/PCBs. Carry out extensive cleaning of internal parts from dust, corrosion and oxide formations. Remove all foreign material using vacuum cleaner/ magnets. Renew all fasteners / securing screws.
11Services - Inspect all internal cabling and patch chords for wear, tear and deterioration of insulation. Renew / repair the defective patch chords.Services - Inspect all internal cabling and patch chords for wear, tear and deterioration of insulation. Renew / repair the defective patch chords.
12Services - Inspect all fuses including spare fuses Renew with correct rating.Services - Inspect all fuses including spare fuses Renew with correct rating.
13Services - Survey of all modular switches, hooters dimmers, alarms & indications lamps etc. on MCR Control panels and ECR control panel. Replace defective parts. SS to supply material.Services - Survey of all modular switches, hooters dimmers, alarms & indications lamps etc. on MCR Control panels and ECR control panel. Replace defective parts. SS to supply material.
14Services - Examine material state of key boards, mouse and other elements of data input. Renew defective parts. SS to supply spares.Services - Examine material state of key boards, mouse and other elements of data input. Renew defective parts. SS to supply spares.
15Services - Carry out serviceability checks of all command and indication channels of interface.Services - Carry out serviceability checks of all command and indication channels of interface.
16Services - Check serviceability of all input and output telemetric channels as per document ДAИE 421455.128-01Services - Check serviceability of all input and output telemetric channels as per document ДAИE 421455.128-01
17Services - Check Communication between MCR and ECR of Burya panel, port and Stdbd section in ECR and all other section in MCR. Repair if not Working.Services - Check Communication between MCR and ECR of Burya panel, port and Stdbd section in ECR and all other section in MCR. Repair if not Working.
18Services - Carry out insulation checks of system as per prescribed procedures. Improve insulation if not within prescribed limits. Record final values.Services - Carry out insulation checks of system as per prescribed procedures. Improve insulation if not within prescribed limits. Record final values.
19Services - Examine and undertake refurbishment/replacement of cabling internal to JB’s/ control panel etc. as required.Services - Examine and undertake refurbishment/replacement of cabling internal to JB’s/ control panel etc. as required.
20Services - Repairs & Maintenance Routines of Instrumentation of CGT’s (FER): Carry out serviceability checks / in-situ calibration of all interfaced sensors. Replace defective sensors. SS to supply new sensor in lieu of defective sensor. List of sensors recommended for procurement/replacement is given in Part B of scope of work.Services - Repairs & Maintenance Routines of Instrumentation of CGT’s (FER): Carry out serviceability checks / in-situ calibration of all interfaced sensors. Replace defective sensors. SS to supply new sensor in lieu of defective sensor. List of sensors recommended for procurement/replacement is given in Part B of scope of work.
21Services - Repairs & Maintenance Routines of Instrumentation of BGT’s (AER): Carry out serviceability checks / in-situ calibration of all interfaced sensors. Replace defective sensors. SS to supply new sensor in lieu of defective sensor. List of sensors recommended for procurement/replacement is given in Part B of scope of work.Services - Repairs & Maintenance Routines of Instrumentation of BGT’s (AER): Carry out serviceability checks / in-situ calibration of all interfaced sensors. Replace defective sensors. SS to supply new sensor in lieu of defective sensor. List of sensors recommended for procurement/replacement is given in Part B of scope of work.
22Services - Routines on UPS of Burya System Undertake all MAINTOPs & OEM prescribed MR routines on UPS devices.Services - Routines on UPS of Burya System Undertake all MAINTOPs & OEM prescribed MR routines on UPS devices.
23Services - Carry out visual inspection of all devices.Services - Carry out visual inspection of all devices.
24Services - Inspect and repairs/replace all defective mechanical fixtures (hinges, locks, bolts, screws, guide rails, commutation connectors etc.)Services - Inspect and repairs/replace all defective mechanical fixtures (hinges, locks, bolts, screws, guide rails, commutation connectors etc.)
25Services - Survey all fuses & indications lamps etc. on UPS fitted in MCR and ECR. Replace all defective units with new.Services - Survey all fuses & indications lamps etc. on UPS fitted in MCR and ECR. Replace all defective units with new.
26Services - Renew all earthing strips. Clean and polish all mating surfaces.Services - Renew all earthing strips. Clean and polish all mating surfaces.
27Services - Examine all shock mounts of Units. Renew defective mounts if found.Services - Examine all shock mounts of Units. Renew defective mounts if found.
28Services - Carry out inspection of all internal connections for wear & tear. Renew defective internal cabling and connectors.Services - Carry out inspection of all internal connections for wear & tear. Renew defective internal cabling and connectors.
29Services - Check availability of main and reserve power supply on module MФФ and repair if defective.Services - Check availability of main and reserve power supply on module MФФ and repair if defective.
30Services - Check insulation of UPS device with respect to earth as per technical description and operating instructions.Services - Check insulation of UPS device with respect to earth as per technical description and operating instructions.
31Services - Remove all modules and PCBs to electronic Lab. And undertake following: -i) Carry out routines on all electronic circuitry.ii) Carry out decarbonisation of all modules and PCBs.iii) Carry out refurbishment of modules and power supply devices.iv) Check correctness of ratings of all fuses assemblies.v) Check functioning of all lamps and indications.vi) Carry out polishing of all contacts and mating surfaces.vii) Renew conformal coating of modules /PCBs as applicable.viii) Check serviceability of units for which test facility exists at the Lab.(ix) Carry out load test on power supply Modules.Services - Remove all modules and PCBs to electronic Lab. And undertake following: -i) Carry out routines on all electronic circuitry.ii) Carry out decarbonisation of all modules and PCBs.iii) Carry out refurbishment of modules and power supply devices.iv) Check correctness of ratings of all fuses assemblies.v) Check functioning of all lamps and indications.vi) Carry out polishing of all contacts and mating surfaces.vii) Renew conformal coating of modules /PCBs as applicable.viii) Check serviceability of units for which test facility exists at the Lab.(ix) Carry out load test on power supply Modules.
32Services - Check condition of batteries in unit MAƂ. Discharge the batteries by switching 'ON' the associated system & put on charge, if the batteries are not used for prolonged duration. Carry out capacity test of battery and renew battery bank if capacity less than 80 %. SS to supply new batteries.Services - Check condition of batteries in unit MAƂ. Discharge the batteries by switching 'ON' the associated system & put on charge, if the batteries are not used for prolonged duration. Carry out capacity test of battery and renew battery bank if capacity less than 80 %. SS to supply new batteries.
33Services - Check serviceability of MK3Б. modules as per technical manual by selecting battery supply and check output of battery on modules MK3Б. with and without load.Services - Check serviceability of MK3Б. modules as per technical manual by selecting battery supply and check output of battery on modules MK3Б. with and without load.
34Services - Check lamps/LEDs and holders for correct operation. Replace Defective lamps/LEDs and lamp holders.Services - Check lamps/LEDs and holders for correct operation. Replace Defective lamps/LEDs and lamp holders.
35Services - Check tightness of connectors, cable glands and internal/ external cable connections.Services - Check tightness of connectors, cable glands and internal/ external cable connections.
36Services - Check normal and battery modes of operation.Services - Check normal and battery modes of operation.
37Services - Check correct functioning of over load mode for MФФ unit.Services - Check correct functioning of over load mode for MФФ unit.
38Services - Carry out serviceability checks of all modular switches on operator’s panel. Repair/ Renew non-functional switches.Services - Carry out serviceability checks of all modular switches on operator’s panel. Repair/ Renew non-functional switches.
39Services - Check ventilation openings of the UPS and Clean with brush.Services - Check ventilation openings of the UPS and Clean with brush.
40Services - Check securing arrangement of all modules. Renew all missing screws.Services - Check securing arrangement of all modules. Renew all missing screws.
41Services - Check alignment of guiding pins and connector pins. Inspect connectors for any bend /damaged pins. Replace with new as necessary.Services - Check alignment of guiding pins and connector pins. Inspect connectors for any bend /damaged pins. Replace with new as necessary.
42Services - Open and inspect all cable connectors of devices. Inspect for loose material particles, breakages of contact etc. Inspect cable for intactness of all earthing / grounding of metallic sleeves. Fit back the connectors after decarbonisation of male and female connectors.Services - Open and inspect all cable connectors of devices. Inspect for loose material particles, breakages of contact etc. Inspect cable for intactness of all earthing / grounding of metallic sleeves. Fit back the connectors after decarbonisation of male and female connectors.
43Services - Check serviceability and condition of cables and connectors inter connecting devices and improve insulation if found below acceptable limits, especially degutted cables and cables in engine room.Services - Check serviceability and condition of cables and connectors inter connecting devices and improve insulation if found below acceptable limits, especially degutted cables and cables in engine room.
44Services - Inspect internal wiring of units. Check intactness of all connectors and internal cabling. Repair/ Renew defectivecables/connector if any.Services - Inspect internal wiring of units. Check intactness of all connectors and internal cabling. Repair/ Renew defectivecables/connector if any.
45Services - PHASE –III Burya Control System Rectification of defects and Setting to Work- Installation/ Re-gutting of all panels, devices, JBs and sensors etc. on proper foundation after new GT and RG is installed on the foundation.Services - PHASE –III Burya Control System Rectification of defects and Setting to Work- Installation/ Re-gutting of all panels, devices, JBs and sensors etc. on proper foundation after new GT and RG is installed on the foundation.
46Services - PHASE –III Burya Control System Rectification of defects and Setting to Work- Secure all the cables with clamps, degutted for replacement of GT and RG. Carry out routine on the cables and de- carbonisation of connectors, Replace worn out shielding/screen and cable lugs etc.Services - PHASE –III Burya Control System Rectification of defects and Setting to Work- Secure all the cables with clamps, degutted for replacement of GT and RG. Carry out routine on the cables and de- carbonisation of connectors, Replace worn out shielding/screen and cable lugs etc.
47Services - PHASE –III Burya Control System Rectification of defects and Setting to Work- Remove and land meter and gauges to MECI for calibrations. Re-fitment of all meter and gauges post calibrations and checks serviceability. (approx. qty.50 nos)Services - PHASE –III Burya Control System Rectification of defects and Setting to Work- Remove and land meter and gauges to MECI for calibrations. Re-fitment of all meter and gauges post calibrations and checks serviceability. (approx. qty.50 nos)
48Services - PHASE –III Burya Control System Rectification of defects and Setting to Work- Checks serviceability of MCR control console & replace perished wires, defective indications Lamps.Services - PHASE –III Burya Control System Rectification of defects and Setting to Work- Checks serviceability of MCR control console & replace perished wires, defective indications Lamps.
49Services - PHASE –III Burya Control System Rectification of defects and Setting to Work- Checks serviceability of ECR control console & replace perished wires ,defective indications Lamps.Services - PHASE –III Burya Control System Rectification of defects and Setting to Work- Checks serviceability of ECR control console & replace perished wires ,defective indications Lamps.
50Services - PHASE –III Burya Control System Rectification of defects and Setting to Work- Check and prove Ethernet LAN network protocol between MCR console and ECR console. Replace cable, if required.Services - PHASE –III Burya Control System Rectification of defects and Setting to Work- Check and prove Ethernet LAN network protocol between MCR console and ECR console. Replace cable, if required.
51Services - PHASE –III Burya Control System Rectification of defects and Setting to Work- Check serviceability of Local Technological Stations(LTS) in FWD & AFT Engine Room and Rectify defect if any.(Qty.04 nos)Services - PHASE –III Burya Control System Rectification of defects and Setting to Work- Check serviceability of Local Technological Stations(LTS) in FWD & AFT Engine Room and Rectify defect if any.(Qty.04 nos)
52Services - PHASE –III Burya Control System Rectification of defects and Setting to Work- Check integrity of serial communication link RS232 & RS485 protocol for interfacing.Services - PHASE –III Burya Control System Rectification of defects and Setting to Work- Check integrity of serial communication link RS232 & RS485 protocol for interfacing.
53Services - PHASE –III Burya Control System Rectification of defects and Setting to Work- Check integrity of MIL-STD 1553B Communication link protocol between LTS TO MCR console & LTS to ECR console.Services - PHASE –III Burya Control System Rectification of defects and Setting to Work- Check integrity of MIL-STD 1553B Communication link protocol between LTS TO MCR console & LTS to ECR console.
54Services - PHASE –III Burya Control System Rectification of defects and Setting to Work- Carry out Serviceability checks of Servo Control Device. Undertake Tunning if required.Services - PHASE –III Burya Control System Rectification of defects and Setting to Work- Carry out Serviceability checks of Servo Control Device. Undertake Tunning if required.
55Services - PHASE –III Burya Control System Rectification of defects and Setting to Work- Carry out Serviceability checks of BURYA printer and rectify defect if any.Services - PHASE –III Burya Control System Rectification of defects and Setting to Work- Carry out Serviceability checks of BURYA printer and rectify defect if any.
56Services - PHASE –III Burya Control System Rectification of defects and Setting to Work- Carry out Insulations checks of BURYA control System & rectify if not within prescribed limit.Services - PHASE –III Burya Control System Rectification of defects and Setting to Work- Carry out Insulations checks of BURYA control System & rectify if not within prescribed limit.
57Services - PHASE –III Burya Control System Rectification of defects and Setting to Work- Carry out Power supply checks for BURYA control supply from FWD & AFT switch boards and rectify defect if any.Services - PHASE –III Burya Control System Rectification of defects and Setting to Work- Carry out Power supply checks for BURYA control supply from FWD & AFT switch boards and rectify defect if any.
58Services - PHASE –III Burya Control System Rectification of defects and Setting to Work- Rectify all known defects projected by yard/SS. List place at enclosure.Services - PHASE –III Burya Control System Rectification of defects and Setting to Work- Rectify all known defects projected by yard/SS. List place at enclosure.
59Services - PHASE –III Burya Control System Rectification of defects and Setting to Work- Offer system for GTTT (Mbi) stage inspections. Rectify all observations.Services - PHASE –III Burya Control System Rectification of defects and Setting to Work- Offer system for GTTT (Mbi) stage inspections. Rectify all observations.
60Services - PHASE –III Burya Control System Rectification of defects and Setting to Work- Check serviceability of UPS units. Carry out repairs /refurbishment of modules. Replace defective modules if any SS to supply modules.Services - PHASE –III Burya Control System Rectification of defects and Setting to Work- Check serviceability of UPS units. Carry out repairs /refurbishment of modules. Replace defective modules if any SS to supply modules.
61Services - PHASE –III Burya Control System Rectification of defects and Setting to Work- Check and prove battery supply back up timing as per document.Services - PHASE –III Burya Control System Rectification of defects and Setting to Work- Check and prove battery supply back up timing as per document.
62Services - PHASE –III Burya Control System Rectification of defects and Setting to Work- Switch on power supply and check serviceability and correct functioning of modules and displays. Repair/rectify defect if not working.Services - PHASE –III Burya Control System Rectification of defects and Setting to Work- Switch on power supply and check serviceability and correct functioning of modules and displays. Repair/rectify defect if not working.
63Services - PHASE –III Burya Control System Rectification of defects and Setting to Work- Switch ‘ON’ main and reserve Power supplies to system and check for smooth change over.Services - PHASE –III Burya Control System Rectification of defects and Setting to Work- Switch ‘ON’ main and reserve Power supplies to system and check for smooth change over.
64Services - PHASE –III Burya Control System Rectification of defects and Setting to Work- Undertake complete functional checks and proving of system including all telemetric channels and interfaces with other system.Services - PHASE –III Burya Control System Rectification of defects and Setting to Work- Undertake complete functional checks and proving of system including all telemetric channels and interfaces with other system.
65Services - PHASE –III Burya Control System Rectification of defects and Setting to Work- Check and correct software versions of system spare modules.Services - PHASE –III Burya Control System Rectification of defects and Setting to Work- Check and correct software versions of system spare modules.
66Services - PHASE –III Burya Control System Rectification of defects and Setting to Work- Carry out Setting to Work and Testing & tuning including tuning of software based on present status, as required) of Burya Control System (as per OEM protocol document.Services - PHASE –III Burya Control System Rectification of defects and Setting to Work- Carry out Setting to Work and Testing & tuning including tuning of software based on present status, as required) of Burya Control System (as per OEM protocol document.
67Services - PHASE –III Burya Control System Rectification of defects and Setting to Work-Carry out rectification of all observations during (STW) of all units.Services - PHASE –III Burya Control System Rectification of defects and Setting to Work-Carry out rectification of all observations during (STW) of all units.
68Services - PHASE –IV - Burya Control System – Harbour trials and sea trials in full scope (as per OEM Document).Services - PHASE –IV - Burya Control System – Harbour trials and sea trials in full scope (as per OEM Document).
69Services - PHASE-I DIAGNOSTIC SURVEY ZORYA CONTROL SYSTEM : - Undertake detailed defect survey of onboard equipment of system local control system of GT’s & RG’s i.e all Control stations, devices JBs and sensors. Etc. finalise scope/ quantum of repair and MR maintenance servicesServices - PHASE-I DIAGNOSTIC SURVEY ZORYA CONTROL SYSTEM : - Undertake detailed defect survey of onboard equipment of system local control system of GT’s & RG’s i.e all Control stations, devices JBs and sensors. Etc. finalise scope/ quantum of repair and MR maintenance services
70Services - PHASE –II Repairs & Maintenance Routines Zorya Control System : Degutting of control cables connected from GT/RG to the foundation frame and cables coming from devices and equipment’s to the frame and preserves them safely for re-use.Services - PHASE –II Repairs & Maintenance Routines Zorya Control System : Degutting of control cables connected from GT/RG to the foundation frame and cables coming from devices and equipment’s to the frame and preserves them safely for re-use.
71Services - Degutting of all GT’s frame connectors, cables, JB’S and sensors etc. required for providing clear passage to remove Gas Turbine and RG.Services - Degutting of all GT’s frame connectors, cables, JB’S and sensors etc. required for providing clear passage to remove Gas Turbine and RG.
72Services - Undertake ALL MAINTOP/ OEM prescribed MR routines on system.Services - Undertake ALL MAINTOP/ OEM prescribed MR routines on system.
73Services - Carry out external inspection of all devices and JBS. Rectify all mechanical defects. Undertake cleaning, degreasing. Renew all missing / corroded fasteners.Services - Carry out external inspection of all devices and JBS. Rectify all mechanical defects. Undertake cleaning, degreasing. Renew all missing / corroded fasteners.
74Services - Renew all earthing strips. Clean and polish all contact surfaces.Services - Renew all earthing strips. Clean and polish all contact surfaces.
75Services - Examine all shock mounts of Units. Renew with equivalents as necessary.Services - Examine all shock mounts of Units. Renew with equivalents as necessary.
76Services - Inspect all JB’s for corrosion. Inspect condition of cables and cable connections. Clean internally and renew connections and ferules as required.Services - Inspect all JB’s for corrosion. Inspect condition of cables and cable connections. Clean internally and renew connections and ferules as required.
77Services - Inspect all cable connectors. Carry out cleaning and decarbonisation of connectors. Polish all pins and mating Surfaces. Inspect earthing/cable screen. Repair re-solder as Necessary.Services - Inspect all cable connectors. Carry out cleaning and decarbonisation of connectors. Polish all pins and mating Surfaces. Inspect earthing/cable screen. Repair re-solder as Necessary.
78Services - Undertake internal inspection of all devices and equipment of the system. Remove all modules /PCBs. Carry out extensive cleaning of internal parts from dust, corrosion and oxide formations. Remove all foreign material using vacuum cleaner/ magnets. Renew all fasteners / securing screws.Services - Undertake internal inspection of all devices and equipment of the system. Remove all modules /PCBs. Carry out extensive cleaning of internal parts from dust, corrosion and oxide formations. Remove all foreign material using vacuum cleaner/ magnets. Renew all fasteners / securing screws.
79Services - Inspect all internal cabling for wear, tear and deterioration of insulation. Renew / repair as Required.Services - Inspect all internal cabling for wear, tear and deterioration of insulation. Renew / repair as Required.
80Services - Inspect all fuses including spare fuses Renew with correct rating.Services - Inspect all fuses including spare fuses Renew with correct rating.
81Services - Remove & land of all modules to Lab. Carry out decarbonisation of modules. Carry out detailed inspection and undertake refurbishment of modules. On completion carry out functional tests of modules. Inspect connectors. Replace as necessary. Decarbonise and polish all pins and mating surfaces. Carry out renewal of conformal coating of modules, as applicable.Services - Remove & land of all modules to Lab. Carry out decarbonisation of modules. Carry out detailed inspection and undertake refurbishment of modules. On completion carry out functional tests of modules. Inspect connectors. Replace as necessary. Decarbonise and polish all pins and mating surfaces. Carry out renewal of conformal coating of modules, as applicable.
82Services - Check insulation resistance of convertors circuit used for thermo electric measurement of GT outlet gas temp across the thermal junction boxes of TXA-1368.Services - Check insulation resistance of convertors circuit used for thermo electric measurement of GT outlet gas temp across the thermal junction boxes of TXA-1368.
83Services - Open MIII type connectors of GT control station all electrical equipment’s, Decarbonise and wipe out with the help of alcohol and calico Cloth.Services - Open MIII type connectors of GT control station all electrical equipment’s, Decarbonise and wipe out with the help of alcohol and calico Cloth.
84Services - Check condition of Plasma ignition unit in accordance with the manual. Check condition of control PCB , capacitor banks and connectors. Clean contacts with brush and alcohol.Services - Check condition of Plasma ignition unit in accordance with the manual. Check condition of control PCB , capacitor banks and connectors. Clean contacts with brush and alcohol.
85Services -Maintenance routines and replacement of brushes of ШПM current collector assembly for PORT & STBD shaft, if required.Services -Maintenance routines and replacement of brushes of ШПM current collector assembly for PORT & STBD shaft, if required.
86Services - Check and Prove Air flux clutching mechanism of Boost gas turbineServices - Check and Prove Air flux clutching mechanism of Boost gas turbine
87Services - Carry out insulation test and continuity test of cables of all electrical devices, sub devices and sensors associated with Zorya control system as required vide maint. Documents. Improve insulation if not within limits.Services - Carry out insulation test and continuity test of cables of all electrical devices, sub devices and sensors associated with Zorya control system as required vide maint. Documents. Improve insulation if not within limits.
88Services - Fitment of all slotted and magnetic chip detectors of both CGT and BGT (QTY. 24 nos.). Insulation test and continuity test of cables connected to all slotted and magnetic chip detectors KCCCM and CC of all four GTs. Check condition of cables and replace cables.Services - Fitment of all slotted and magnetic chip detectors of both CGT and BGT (QTY. 24 nos.). Insulation test and continuity test of cables connected to all slotted and magnetic chip detectors KCCCM and CC of all four GTs. Check condition of cables and replace cables.
89Services - Check Serviceability of БИСС, БУСС and БСР units. Repair/Refurbishment of units as Required.Services - Check Serviceability of БИСС, БУСС and БСР units. Repair/Refurbishment of units as Required.
90Services - Check Serviceability of spark plugs, spark plug cables and plasma ignition units of both CGT and BGT. Fitment of spark plugs, spark plug cables and plasma ignition units of PCGT and SCGT. Check condition of cables.Services - Check Serviceability of spark plugs, spark plug cables and plasma ignition units of both CGT and BGT. Fitment of spark plugs, spark plug cables and plasma ignition units of PCGT and SCGT. Check condition of cables.
91Services - Carry out insulation test, and continuity test of supply and control cables connected with plasma ignition unit of all four GTs. Check condition of cablesServices - Carry out insulation test, and continuity test of supply and control cables connected with plasma ignition unit of all four GTs. Check condition of cables
92Services - Check Serviceability of ДЛПГ, ДПНА1, ДПНА2, ДТП1, ДТП2, КПВ, КПф and transducers and valves. Repair/Refurbishment or replacement of transducers and valves as required. Transducer and valves to be provided by SS.Services - Check Serviceability of ДЛПГ, ДПНА1, ДПНА2, ДТП1, ДТП2, КПВ, КПф and transducers and valves. Repair/Refurbishment or replacement of transducers and valves as required. Transducer and valves to be provided by SS.
93Services - Carry out insulation test, continuity test and connection of cables with GT control station (via KCAЛ connection box) of ДЛПГ, ДПНА1, ДПНА2, ДТП1, ДТП2, КПВ, КПф and КЗОТ transducers and valves. Check condition of Cable.Services - Carry out insulation test, continuity test and connection of cables with GT control station (via KCAЛ connection box) of ДЛПГ, ДПНА1, ДПНА2, ДТП1, ДТП2, КПВ, КПф and КЗОТ transducers and valves. Check condition of Cable.
94Services -Check serviceability of ДСО transducer (СВМ-Д) and connection of transducer with Synchronizer CBM-4. Check condition of cablesServices -Check serviceability of ДСО transducer (СВМ-Д) and connection of transducer with Synchronizer CBM-4. Check condition of cables
95Services - Check serviceability of ДМД, ДМД1, ДТАЗ, КАС, КПТ, MCK and MCT units and transducers. Fitment of ДМД, ДМД1, ДТАЗ, КАС, КПТ, MCK and MCT units and transducers of both CGTs. Repair/Refurbish transducers/units. SS to provide new transducers in lieu of defective ones for replacement.Services - Check serviceability of ДМД, ДМД1, ДТАЗ, КАС, КПТ, MCK and MCT units and transducers. Fitment of ДМД, ДМД1, ДТАЗ, КАС, КПТ, MCK and MCT units and transducers of both CGTs. Repair/Refurbish transducers/units. SS to provide new transducers in lieu of defective ones for replacement.
96Services - Carry out insulation test, continuity test and connection of cables with GT control station (via КСАП) of ДМД, ДМД1, ДТАЗ, КАС, КПТ, MCK and MCT units and transducers. Check condition of cables.Services - Carry out insulation test, continuity test and connection of cables with GT control station (via КСАП) of ДМД, ДМД1, ДТАЗ, КАС, КПТ, MCK and MCT units and transducers. Check condition of cables.
97Services - Carry out insulation test, continuity test and connection of cables from connection boxes KCAЛ and КСАП to GT control station. Check condition of cables.Services - Carry out insulation test, continuity test and connection of cables from connection boxes KCAЛ and КСАП to GT control station. Check condition of cables.
98Services - Check serviceability of ПКЦ unit of all four Gts and connection of unit with GT control station. Check condition of cables.Services - Check serviceability of ПКЦ unit of all four Gts and connection of unit with GT control station. Check condition of cables.
99Services - Fitment of KCPT connector of CGTs. Check insulation test, continuity test and connection of cables from KCPT connection box to GT control station. Check condition of cables.Services - Fitment of KCPT connector of CGTs. Check insulation test, continuity test and connection of cables from KCPT connection box to GT control station. Check condition of cables.
100Services - Check serviceability of ВЗХ, ВПХ, ДСВ, КНЗХ, КСЗХ, КНПХ, КСПХ, KHCB and KCCB micro-switches and manipulators. Connection of all micro-switches and manipulators with GT control station (via KCPT connection box). Check condition of cables.Services - Check serviceability of ВЗХ, ВПХ, ДСВ, КНЗХ, КСЗХ, КНПХ, КСПХ, KHCB and KCCB micro-switches and manipulators. Connection of all micro-switches and manipulators with GT control station (via KCPT connection box). Check condition of cables.
101Services - Fitment of КС429 box of both CGTs. Insulation test, continuity test and connection of cables from ХТП connector to КСТП box, КСТП box to LTS and КСТП box to РТИ unit of all four Gts. Check condition of cables.Services - Fitment of КС429 box of both CGTs. Insulation test, continuity test and connection of cables from ХТП connector to КСТП box, КСТП box to LTS and КСТП box to РТИ unit of all four Gts. Check condition of cables.
102Services - Carry out insulation test, continuity test and check connection of cables from РТИ unit GT control station and 127 V DB. Check condition of cables.Services - Carry out insulation test, continuity test and check connection of cables from РТИ unit GT control station and 127 V DB. Check condition of cables.
103Services - Check serviceability of ДОРТ sensor. Carry out insulation test, continuity test and connection of cables from sensor to the OPT unit via КСДОРТ connector for both CGT and BGT. Check condition of cables.Services - Check serviceability of ДОРТ sensor. Carry out insulation test, continuity test and connection of cables from sensor to the OPT unit via КСДОРТ connector for both CGT and BGT. Check condition of cables.
104Services - Check serviceability of OPT units (Qty- 04) and connection of OPT unit with GT control station, ДОРТ sensor. Check condition of cables.Services - Check serviceability of OPT units (Qty- 04) and connection of OPT unit with GT control station, ДОРТ sensor. Check condition of cables.
105Services - Check serviceability and fitment of RTDs (ТСП 8040-5Ц.2821439-01) of ТСД, ТСМОД, TCMOP, ТСКНД, ТСКВД, TCTB, and ТСТНД of both CGT and BGT. Carry out insulation test, continuity test and connection of cables of all RTDs with LTS. Check condition of cables.Services - Check serviceability and fitment of RTDs (ТСП 8040-5Ц.2821439-01) of ТСД, ТСМОД, TCMOP, ТСКНД, ТСКВД, TCTB, and ТСТНД of both CGT and BGT. Carry out insulation test, continuity test and connection of cables of all RTDs with LTS. Check condition of cables.
106Services - Fitment of KCAO connection box of both CGTs and connection of KCAO with associated Zorya units i.e Altivar, БИСС, БPR, ПК, БВРТПН and GT control station. Check condition of cables.Services - Fitment of KCAO connection box of both CGTs and connection of KCAO with associated Zorya units i.e Altivar, БИСС, БPR, ПК, БВРТПН and GT control station. Check condition of cables.
107Services - Check connection of cables from GT control station to 27V DB, LTS, RG control station, KCAO, ПКЦ, ХДСО, КСАП, KCPT, РТИ and OPT units Check condition of cablesServices - Check connection of cables from GT control station to 27V DB, LTS, RG control station, KCAO, ПКЦ, ХДСО, КСАП, KCPT, РТИ and OPT units Check condition of cables
108Services - Carry out insulation test, continuity test and connection of cables of all four GT control stations. Check condition of cables.Services - Carry out insulation test, continuity test and connection of cables of all four GT control stations. Check condition of cables.
109Services - Check serviceability of Ignition switches of both CGT and BGT and Insulation test, continuity test and connection of cables from ignition switch to GT control station. Check condition of cables.Services - Check serviceability of Ignition switches of both CGT and BGT and Insulation test, continuity test and connection of cables from ignition switch to GT control station. Check condition of cables.
110Services - Fitment of connection boxes ЯМ (СЯ72-22 o/n), 1KPM, 2KPM (СЯ42-20 o/n), ЯП (СЯ72- 22 o/n) of both CRGs at designated locations. Check condition of cables.Services - Fitment of connection boxes ЯМ (СЯ72-22 o/n), 1KPM, 2KPM (СЯ42-20 o/n), ЯП (СЯ72- 22 o/n) of both CRGs at designated locations. Check condition of cables.
111Services - Check serviceability and fitment of ТСГ (Air inlet) and ТСП (GT casing) thermocouples (TXA 1172.5Ц2.821.679-6601) of all four Gts. Insulation test, continuity test and connection of cables of both thermocouples to respective LTS. Check condition of cables.Services - Check serviceability and fitment of ТСГ (Air inlet) and ТСП (GT casing) thermocouples (TXA 1172.5Ц2.821.679-6601) of all four Gts. Insulation test, continuity test and connection of cables of both thermocouples to respective LTS. Check condition of cables.
112Services - Check serviceability and fitment of 1BBK, 2BBK, ВВПУ, ВПТ, 1BOK and 2BOK micro switches of both CRGs. Carry out insulation test, continuity test and connection of cables from all micro switches to ЯМ connection box. Check condition of cables.Services - Check serviceability and fitment of 1BBK, 2BBK, ВВПУ, ВПТ, 1BOK and 2BOK micro switches of both CRGs. Carry out insulation test, continuity test and connection of cables from all micro switches to ЯМ connection box. Check condition of cables.
113Services - Check serviceability and fitment of Oil pressure sensors (ДМР) of both CRGs (Qty- 08). Insulation test, continuity test and connection of cables from all sensors to ЯМ connection box of CRGs and BRGs. Check condition of cables.Services - Check serviceability and fitment of Oil pressure sensors (ДМР) of both CRGs (Qty- 08). Insulation test, continuity test and connection of cables from all sensors to ЯМ connection box of CRGs and BRGs. Check condition of cables.
114Services - Check serviceability and fitment of ДОТ1, ДОТ2, 1ДС1, 1ДС2, 2ДС1, 2ДС2,1ДСВ, 2ДСВ and 2ДСШ transducers of both CRGs. Insulation test, continuity test and connection of cables from all transducers to respective CBM units. Check condition of cables.Services - Check serviceability and fitment of ДОТ1, ДОТ2, 1ДС1, 1ДС2, 2ДС1, 2ДС2,1ДСВ, 2ДСВ and 2ДСШ transducers of both CRGs. Insulation test, continuity test and connection of cables from all transducers to respective CBM units. Check condition of cables.
115Services - Check serviceability and fitment of 1ДДК, 2ДДК, 1ДДф, 2ДДф transducers of both CRGs. Insulation test, continuity test and connection of cables from all transducers to ЯМ connection box. Check condition of cables.Services - Check serviceability and fitment of 1ДДК, 2ДДК, 1ДДф, 2ДДф transducers of both CRGs. Insulation test, continuity test and connection of cables from all transducers to ЯМ connection box. Check condition of cables.
116Services - Check serviceability and fitment of 1KBK, 2KBK, 1KOK, 2KOK, 1 Кф and 2КфEM valves of both CRGs. Carry out insulation test, continuity test and connection of cables from all EM valves to ЯМ connection boxes of all four GTs. Check condition of cables.Services - Check serviceability and fitment of 1KBK, 2KBK, 1KOK, 2KOK, 1 Кф and 2КфEM valves of both CRGs. Carry out insulation test, continuity test and connection of cables from all EM valves to ЯМ connection boxes of all four GTs. Check condition of cables.
117Services - Carry out insulation test, continuity test and check connection of cables from ЯМ connection box to CRG and BRG control stations. Check condition of cables.Services - Carry out insulation test, continuity test and check connection of cables from ЯМ connection box to CRG and BRG control stations. Check condition of cables.
118Services- Carry out insulation test, continuity test and connection of cables from all CBM units to CRG, BRG and CRGA control stations including relay units. Check condition of cables.Services- Carry out insulation test, continuity test and connection of cables from all CBM units to CRG, BRG and CRGA control stations including relay units. Check condition of cables.
119Services- Check serviceability and fitment of ДОТ1 and ДОТ2 sensors. Carry out insulation test, continuity test and connection of cables from sensors to respective ПЧУ and LTS units. Check condition of cables.Services- Check serviceability and fitment of ДОТ1 and ДОТ2 sensors. Carry out insulation test, continuity test and connection of cables from sensors to respective ПЧУ and LTS units. Check condition of cables.
120Services- Carry out insulation test, continuity test and connection of cables of all ПЧУ units with all four GT and RG control stations. Check condition of cables.Services- Carry out insulation test, continuity test and connection of cables of all ПЧУ units with all four GT and RG control stations. Check condition of cables.
121Services- Fitment of 1KPM and 2KPM connection boxes of both CRGs to designated locations. Carry out insulation test, continuity test and connection of cables of 1KPM and 2KPM with LTS. Check condition of cables.Services- Fitment of 1KPM and 2KPM connection boxes of both CRGs to designated locations. Carry out insulation test, continuity test and connection of cables of 1KPM and 2KPM with LTS. Check condition of cables.
122Services- Check serviceability and fitment of 1TPM to 24 TPM RTDs of both CRGs and carry out insulation test, continuity test and connection of cables from RTDs to 1KPM and 2KPM connection boxes. Check condition of cables.Services- Check serviceability and fitment of 1TPM to 24 TPM RTDs of both CRGs and carry out insulation test, continuity test and connection of cables from RTDs to 1KPM and 2KPM connection boxes. Check condition of cables.
123Services- Check serviceability of ВВКП, ВОКП, ДДКП, ДДфП, КОКП, BBKЛ, BOKЛ, ДДфЛ, КОКЛ and КВКЛ micro switches of CRGA. Carry out insulation test, continuity test and check connection of cables of all micro switches and EM valves with the ЯП connection box. Check condition of cables.Services- Check serviceability of ВВКП, ВОКП, ДДКП, ДДфП, КОКП, BBKЛ, BOKЛ, ДДфЛ, КОКЛ and КВКЛ micro switches of CRGA. Carry out insulation test, continuity test and check connection of cables of all micro switches and EM valves with the ЯП connection box. Check condition of cables.
124Services- Carry out insulation test, continuity test and connection of cables from ЯП connection box to CRGA control station.Services- Carry out insulation test, continuity test and connection of cables from ЯП connection box to CRGA control station.
125Services- Check serviceability and fitment of 1ДСВ and 2ДСВ transducers. Carry out insulation test, continuity test and connection of cables of transducers to CBM3 unit. Check condition of Cables.Services- Check serviceability and fitment of 1ДСВ and 2ДСВ transducers. Carry out insulation test, continuity test and connection of cables of transducers to CBM3 unit. Check condition of Cables.
126Services- Secure all the cables with clamps, degutted for replacement of GT and RG. Carry out routine on the cables and de- carbonisation of connectors, Replace worn out shielding/screen and cable lugs.Services- Secure all the cables with clamps, degutted for replacement of GT and RG. Carry out routine on the cables and de- carbonisation of connectors, Replace worn out shielding/screen and cable lugs.
127Services- Repair all known defects projected by yard/SS.Services- Repair all known defects projected by yard/SS.
128Services- Check serviceability and fitment of Synchronizer units (Qty- 08). Carry out Repair/Refurbishment of units.Services- Check serviceability and fitment of Synchronizer units (Qty- 08). Carry out Repair/Refurbishment of units.
129Services- Check serviceability of РТИ units (QTY- 04). Carry out Repair/Refurbishment of PCBs and Unit.Services- Check serviceability of РТИ units (QTY- 04). Carry out Repair/Refurbishment of PCBs and Unit.
130Services- Serviceability checks and calibration of all MCTB and СДУ type sensors of all four Gts. Repair/Refurbish/replace the defective sensors. Sensors to be provided by SS.Services- Serviceability checks and calibration of all MCTB and СДУ type sensors of all four Gts. Repair/Refurbish/replace the defective sensors. Sensors to be provided by SS.
131Services- Serviceability checks /calibration of 1ДМР transducer, ВПР micro switch, RTDs 13Тф to 22 Тф, RTDs 25Тф to ЗОТф, KBШ and KOШ EM valves. Repair/Refurbish/replace the defective transducers/EM valves. Spares to be provided by SS.Services- Serviceability checks /calibration of 1ДМР transducer, ВПР micro switch, RTDs 13Тф to 22 Тф, RTDs 25Тф to ЗОТф, KBШ and KOШ EM valves. Repair/Refurbish/replace the defective transducers/EM valves. Spares to be provided by SS.
132Services- Check serviceability of pressure relay КРД2 (РД) of GT and RG (Qty- 08). Repair/Refurbishment the units.Services- Check serviceability of pressure relay КРД2 (РД) of GT and RG (Qty- 08). Repair/Refurbishment the units.
133Services- Check serviceability of ТП1 toТП10 thermocouples (TXA 1368 type). (Qty- 40 nos.)Services- Check serviceability of ТП1 toТП10 thermocouples (TXA 1368 type). (Qty- 40 nos.)
134Services - PHASE –III - Setting to Work of GT local Control system Zorya Control System : Installation/ Re-gutting of all control stations, JBs and sensors etc. on proper foundation after new GT and RG is installed on the foundation.Services - PHASE –III - Setting to Work of GT local Control system Zorya Control System : Installation/ Re-gutting of all control stations, JBs and sensors etc. on proper foundation after new GT and RG is installed on the foundation.
135Services- Carry out Insulation checks on Zorya system devices, GTCS, RGCS, etc. and improve it if found Low.Services- Carry out Insulation checks on Zorya system devices, GTCS, RGCS, etc. and improve it if found Low.
136Services- Switch ÓN’ main and reserve Power supplies to system and check for smooth change over. Rectify defects.Services- Switch ÓN’ main and reserve Power supplies to system and check for smooth change over. Rectify defects.
137Services- Carry out Setting to Work and Testing & tuning of Zorya Control System (as per OEM protocol Document)Services- Carry out Setting to Work and Testing & tuning of Zorya Control System (as per OEM protocol Document)
138Services- Undertake complete Throttle checks and Throttle timing checks on both mode i.e in Normal mode & EMM mode.Services- Undertake complete Throttle checks and Throttle timing checks on both mode i.e in Normal mode & EMM mode.
139Services- Undertake complete functional checks of GT control station (ƂP-Relay block).Services- Undertake complete functional checks of GT control station (ƂP-Relay block).
140Services- Check the interlocks of CGT and BGT. Check condition of cables and replaced as required. Interlock details are as follows: -i) LPC/HPC RPM less than 300/500 rpm.ii)Intake door open.iii) Main and reserve control supply ON.iv) PTN switched ON. v) Shaft and PT turning device OFF.vi) Starter supply ON.vii) Throttle handle in IR position.viii) Stop cock closed.ix) No protection in GT/RG.x) Selections switch in start position.Services- Check the interlocks of CGT and BGT. Check condition of cables and replaced as required. Interlock details are as follows: -i) LPC/HPC RPM less than 300/500 rpm.ii)Intake door open.iii) Main and reserve control supply ON.iv) PTN switched ON. v) Shaft and PT turning device OFF.vi) Starter supply ON.vii) Throttle handle in IR position.viii) Stop cock closed.ix) No protection in GT/RG.x) Selections switch in start position.
141Services- Check the cold and Hot protection checks of CGT and BGT as per maintenance card. List of protection appended below: -i) PT over speed protection.ii) LPC over speed protectioniii) High exhaust gas temperature protectioniv) Low fuel pressure protection.v) Low oil pressure protection of GT and RG.vi) Bypass band protection.vii) ШПM pressure protection.Services- Check the cold and Hot protection checks of CGT and BGT as per maintenance card. List of protection appended below: -i) PT over speed protection.ii) LPC over speed protectioniii) High exhaust gas temperature protectioniv) Low fuel pressure protection.v) Low oil pressure protection of GT and RG.vi) Bypass band protection.vii) ШПM pressure protection.
142Services- Undertake proving of interfaces pertaining to telemetric channel including necessary adjustments as required.Services- Undertake proving of interfaces pertaining to telemetric channel including necessary adjustments as required.
143Services- Carry out rectification of all observations during (STW) of all units and Proving of Zorya control systemServices- Carry out rectification of all observations during (STW) of all units and Proving of Zorya control system
144Services- PHASE - IV:- Zorya Control System: Harbour Acceptance Trials and Sea Acceptance Trials in full scope (as per OEM document).Acceptance Trials and Sea Acceptance Trials in full scope (as per OEM document).Services- PHASE - IV:- Zorya Control System: Harbour Acceptance Trials and Sea Acceptance Trials in full scope (as per OEM document).Acceptance Trials and Sea Acceptance Trials in full scope (as per OEM document).
145Material- Pressure sensor (Sensor type ЭДА-1.6 kgf/cm²-01.C class 0.5 )Material- Pressure sensor (Sensor type ЭДА-1.6 kgf/cm²-01.C class 0.5 )
146Material- Level Indicator (Sensor type УКСУ-67-0680-Φ25-Н-С-0-T1)Material- Level Indicator (Sensor type УКСУ-67-0680-Φ25-Н-С-0-T1)
147Material- Point Level alarm (Sensor type- FTL51-D B82 BB 5 Y9 A (L=700)Material- Point Level alarm (Sensor type- FTL51-D B82 BB 5 Y9 A (L=700)
148Material- Point Level alarm (Sensor type- FTL51-D GR2 DB 5 Y9 A (L=118))Material- Point Level alarm (Sensor type- FTL51-D GR2 DB 5 Y9 A (L=118))
149Material- RTD (Sensor type- ТСП/1-8040 ВП 001-01 )Material- RTD (Sensor type- ТСП/1-8040 ВП 001-01 )
150Material- RTD (Sensor type- ТСП/1-8040 ВП 004-47)Material- RTD (Sensor type- ТСП/1-8040 ВП 004-47)
151Material- RTD (Sensor type- ТСП/1-8040 ВП 001-37)Material- RTD (Sensor type- ТСП/1-8040 ВП 001-37)
152Material- RTD (Sensor type- ТСП/1-8040 ВП 001-46)Material- RTD (Sensor type- ТСП/1-8040 ВП 001-46)
153Material- RTD (Sensor- ТСП/1-8040 ВП 003-08)Material- RTD (Sensor- ТСП/1-8040 ВП 003-08)

AI Tender Summary

OUR REF NO 57110622
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 27-08-2026
Authority
Authority Name Indian Navy
Work Description Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Onboard Ins Teg At Naval Dockyard Mumbai; Repair/Refurbishment And Stw Of Burya Control System Onboard Ins Teg; Service Provider - Service - Phase -I - Diagnostic Survey Of Burya Control System Undertake Detailed Defect Survey Of Onboard Equipment Of System ‘Burya I.E. All Panels ,Ups, Scd,Lts, Tld Devices Jbs, Sensors And Cables Etc. To Finalise Scope/ Quantum Of Repair And Mr Maintenance Services. , Services - Phase –Ii - Burya Control System: Degutting Of Control Cables Connected From Gt/Rg To The Foundation Frame And Cables Coming From Devices And Equipments To The Frame And Preserves Them Safely For Re-Use. , Services - Degutting Of All Panels, Units/Devices, Tlds, Jbs And Sensors Etc. Required For Providing Clear Passage To Remove Gas Turbine And Rg. , Services - Undertake All Maintops & Oem Prescribed Mr Routines On Devices And Control Panels Of System. , Services - Carry Out External Inspection Of All Devices And Jbs. Undertake Cleaning, Degreasing. Renew All Missing / Corroded Fasteners. , Services - Renew All Earthing Strips. Clean And Polish All Contact Surfaces. , Services - Examine All Shock Mounts Of Units. Renew The Defective Mounts, If Any With Equivalents , Services - Inspect All Jbs For Corrosion And Damage Gasket, Change If Required. Inspect Condition Of Cables And Cable Connections. Clean Internally And Renew Connections, Ferules And Defective Lugs. , Services - Inspect All Cable Connectors. Carryout Internal Cleaning And Decarbonisation Of Connectors. Polish All Pins And Mating Surfaces. Inspect Earthing Of Cable Screen. Repair/ Replace Defective Screen. , Services - Undertake Internal Inspection Of All Devices And Equipment Of The System. Remove All Modules/Pcbs. Carry Out Extensive Cleaning Of Internal Parts From Dust, Corrosion And Oxide Formations. Remove All Foreign Material Using Vacuum Cleaner/ Magnets. Renew All Fasteners / Securing Screws. , Services - Inspect All Internal Cabling And Patch Chords For Wear, Tear And Deterioration Of Insulation. Renew / Repair The Defective Patch Chords. , Services - Inspect All Fuses Including Spare Fuses Renew With Correct Rating. , Services - Survey Of All Modular Switches, Hooters Dimmers, Alarms & Indications L S Etc. On Mcr Control Panels And Ecr Control Panel. Replace Defective Parts. Ss To Supply Material. , Services - Examine Material State Of Key Boards, Mouse And Other Elements Of Data Input. Renew Defective Parts. Ss To Supply Spares. , Services - Carry Out Serviceability Checks Of All Command And Indication Channels Of Interface. , Services - Check Serviceability Of All Input And Output Telemetric Channels As Per Document Дaиe 421455.128-01 , Services - Check Communication Between Mcr And Ecr Of Burya Panel, Port And Stdbd Section In Ecr And All Other Section In Mcr. Repair If Not Working. , Services - Carry Out Insulation Checks Of System As Per Prescribed Procedures. Improve Insulation If Not Within Prescribed Limits. Record Final Values. , Services - Examine And Undertake Refurbishment/Replacement Of Cabling Internal To Jbs/ Control Panel Etc. As Required. , Services - Repairs & Maintenance Routines Of Instrumentation Of Cgts (Fer): Carry Out Serviceability Checks / In-Situ Calibration Of All Interfaced Sensors. Replace Defective Sensors. Ss To Supply New Sensor In Lieu Of Defective Sensor. List Of Sensors Recommended For Procurement/Replacement Is Given In Part B Of Scope Of Work. , Services - Repairs & Maintenance Routines Of Instrumentation Of Bgts (Aer): Carry Out Serviceability Checks / In-Situ Calibration Of All Interfaced Sensors. Replace Defective Sensors. Ss To Supply New Sensor In Lieu Of Defective Sensor. List Of Sensors Recommended For Procurement/Replacement Is Given In Part B Of Scope Of Work. , Services - Routines On Ups Of Burya System Undertake All Maintops & Oem Prescribed Mr Routines On Ups Devices. , Services - Carry Out Visual Inspection Of All Devices. , Services - Inspect And Repairs/Replace All Defective Mechanical Fixtures (Hinges, Locks, Bolts, Screws, Guide Rails, Commutation Connectors Etc.) , Services - Survey All Fuses & Indications L S Etc. On Ups Fitted In Mcr And Ecr. Replace All Defective Units With New. , Services - Renew All Earthing Strips. Clean And Polish All Mating Surfaces. , Services - Examine All Shock Mounts Of Units. Renew Defective Mounts If Found. , Services - Carry Out Inspection Of All Internal Connections For Wear & Tear. Renew Defective Internal Cabling And Connectors. , Services - Check Availability Of Main And Reserve Power Supply On Module Mфф And Repair If Defective. , Services - Check Insulation Of Ups Device With Respect To Earth As Per Technical Description And Operating Instructions. , Services - Remove All Modules And Pcbs To Electronic Lab. And Undertake Following: -I) Carry Out Routines On All Electronic Circuitry.Ii) Carry Out Decarbonisation Of All Modules And Pcbs.Iii) Carry Out Refurbishment Of Modules And Power Supply Devices.Iv) Check Correctness Of Ratings Of All Fuses Assemblies.V) Check Functioning Of All L S And Indications.Vi) Carry Out Polishing Of All Contacts And Mating Surfaces.Vii) Renew Conformal Coating Of Modules /Pcbs As Applicable.Viii) Check Serviceability Of Units For Which Test Facility Exists At The Lab.(Ix) Carry Out Load Test On Power Supply Modules. , Services - Check Condition Of Batteries In Unit Maƃ. Discharge The Batteries By Switching On The Associated System & Put On Charge, If The Batteries Are Not Used For Prolonged Duration. Carry Out Capacity Test Of Battery And Renew Battery Bank If Capacity Less Than 80 %. Ss To Supply New Batteries. , Services - Check Serviceability Of Mk3б. Modules As Per Technical Manual By Selecting Battery Supply And Check Output Of Battery On Modules Mk3б. With And Without Load. , Services - Check L S/Leds And Holders For Correct Operation. Replace Defective L S/Leds And L Holders. , Services - Check Tightness Of Connectors, Cable Glands And Internal/ External Cable Connections. , Services - Check Normal And Battery Modes Of Operation. , Services - Check Correct Functioning Of Over Load Mode For Mфф Unit. , Services - Carry Out Serviceability Checks Of All Modular Switches On Operators Panel. Repair/ Renew Non-Functional Switches. , Services - Check Ventilation Openings Of The Ups And Clean With Brush. , Services - Check Securing Arrangement Of All Modules. Renew All Missing Screws. , Services - Check Alignment Of Guiding Pins And Connector Pins. Inspect Connectors For Any Bend /Damaged Pins. Replace With New As Necessary. , Services - Open And Inspect All Cable Connectors Of Devices. Inspect For Loose Material Particles, Breakages Of Contact Etc. Inspect Cable For Intactness Of All Earthing / Grounding Of Metallic Sleeves. Fit Back The Connectors After Decarbonisation Of Male And Female Connectors. , Services - Check Serviceability And Condition Of Cables And Connectors Inter Connecting Devices And Improve Insulation If Found Below Acceptable Limits, Especially Degutted Cables And Cables In Engine Room. , Services - Inspect Internal Wiring Of Units. Check Intactness Of All Connectors And Internal Cabling. Repair/ Renew Defectivecables/Connector If Any. , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work- Installation/ Re-Gutting Of All Panels, Devices, Jbs And Sensors Etc. On Proper Foundation After New Gt And Rg Is Installed On The Foundation. , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work- Secure All The Cables With Cl S, Degutted For Replacement Of Gt And Rg. Carry Out Routine On The Cables And De- Carbonisation Of Connectors, Replace Worn Out Shielding/Screen And Cable Lugs Etc. , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work- Remove And Land Meter And Gauges To Meci For Calibrations. Re-Fitment Of All Meter And Gauges Post Calibrations And Checks Serviceability. (Approx. Qty.50 Nos) , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work- Checks Serviceability Of Mcr Control Console & Replace Perished Wires, Defective Indications L S. , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work- Checks Serviceability Of Ecr Control Console & Replace Perished Wires ,Defective Indications L S. , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work- Check And Prove Ethernet Lan Network Protocol Between Mcr Console And Ecr Console. Replace Cable, If Required. , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work- Check Serviceability Of Local Technological Stations(Lts) In Fwd & Aft Engine Room And Rectify Defect If Any.(Qty.04 Nos) , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work- Check Integrity Of Serial Communication Link Rs232 & Rs485 Protocol For Interfacing. , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work- Check Integrity Of Mil-Std 1553B Communication Link Protocol Between Lts To Mcr Console & Lts To Ecr Console. , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work- Carry Out Serviceability Checks Of Servo Control Device. Undertake Tunning If Required. , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work- Carry Out Serviceability Checks Of Burya Printer And Rectify Defect If Any. , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work- Carry Out Insulations Checks Of Burya Control System & Rectify If Not Within Prescribed Limit. , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work- Carry Out Power Supply Checks For Burya Control Supply From Fwd & Aft Switch Boards And Rectify Defect If Any. , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work- Rectify All Known Defects Projected By Yard/Ss. List Place At Enclosure. , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work- Offer System For Gttt (Mbi) Stage Inspections. Rectify All Observations. , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work- Check Serviceability Of Ups Units. Carry Out Repairs /Refurbishment Of Modules. Replace Defective Modules If Any Ss To Supply Modules. , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work- Check And Prove Battery Supply Back Up Timing As Per Document. , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work- Switch On Power Supply And Check Serviceability And Correct Functioning Of Modules And Displays. Repair/Rectify Defect If Not Working. , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work- Switch ‘On Main And Reserve Power Supplies To System And Check For Smooth Change Over. , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work- Undertake Complete Functional Checks And Proving Of System Including All Telemetric Channels And Interfaces With Other System. , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work- Check And Correct Software Versions Of System Spare Modules. , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work- Carry Out Setting To Work And Testing & Tuning Including Tuning Of Software Based On Present Status, As Required) Of Burya Control System (As Per Oem Protocol Document. , Services - Phase –Iii Burya Control System Rectification Of Defects And Setting To Work-Carry Out Rectification Of All Observations During (Stw) Of All Units. , Services - Phase –Iv - Burya Control System – Harbour Trials And Sea Trials In Full Scope (As Per Oem Document). , Services - Phase-I Diagnostic Survey Zorya Control System : - Undertake Detailed Defect Survey Of Onboard Equipment Of System Local Control System Of Gts & Rgs I.E All Control Stations, Devices Jbs And Sensors. Etc. Finalise Scope/ Quantum Of Repair And Mr Maintenance Services , Services - Phase –Ii Repairs & Maintenance Routines Zorya Control System : Degutting Of Control Cables Connected From Gt/Rg To The Foundation Frame And Cables Coming From Devices And Equipments To The Frame And Preserves Them Safely For Re-Use. , Services - Degutting Of All Gts Frame Connectors, Cables, Jbs And Sensors Etc. Required For Providing Clear Passage To Remove Gas Turbine And Rg. , Services - Undertake All Maintop/ Oem Prescribed Mr Routines On System. , Services - Carry Out External Inspection Of All Devices And Jbs. Rectify All Mechanical Defects. Undertake Cleaning, Degreasing. Renew All Missing / Corroded Fasteners. , Services - Renew All Earthing Strips. Clean And Polish All Contact Surfaces. , Services - Examine All Shock Mounts Of Units. Renew With Equivalents As Necessary. , Services - Inspect All Jbs For Corrosion. Inspect Condition Of Cables And Cable Connections. Clean Internally And Renew Connections And Ferules As Required. , Services - Inspect All Cable Connectors. Carry Out Cleaning And Decarbonisation Of Connectors. Polish All Pins And Mating Surfaces. Inspect Earthing/Cable Screen. Repair Re-Solder As Necessary. , Services - Undertake Internal Inspection Of All Devices And Equipment Of The System. Remove All Modules /Pcbs. Carry Out Extensive Cleaning Of Internal Parts From Dust, Corrosion And Oxide Formations. Remove All Foreign Material Using Vacuum Cleaner/ Magnets. Renew All Fasteners / Securing Screws. , Services - Inspect All Internal Cabling For Wear, Tear And Deterioration Of Insulation. Renew / Repair As Required. , Services - Inspect All Fuses Including Spare Fuses Renew With Correct Rating. , Services - Remove & Land Of All Modules To Lab. Carry Out Decarbonisation Of Modules. Carry Out Detailed Inspection And Undertake Refurbishment Of Modules. On Completion Carry Out Functional Tests Of Modules. Inspect Connectors. Replace As Necessary. Decarbonise And Polish All Pins And Mating Surfaces. Carry Out Renewal Of Conformal Coating Of Modules, As Applicable. , Services - Check Insulation Resistance Of Convertors Circuit Used For Thermo Electric Measurement Of Gt Outlet Gas Temp Across The Thermal Junction Boxes Of Txa-1368. , Services - Open Miii Type Connectors Of Gt Control Station All Electrical Equipments, Decarbonise And Wipe Out With The Help Of Alcohol And Calico Cloth. , Services - Check Condition Of Plasma Ignition Unit In Accordance With The Manual. Check Condition Of Control Pcb , Capacitor Banks And Connectors. Clean Contacts With Brush And Alcohol. , Services -Maintenance Routines And Replacement Of Brushes Of Шпm Current Collector Assembly For Port & Stbd Shaft, If Required. , Services - Check And Prove Air Flux Clutching Mechanism Of Boost Gas Turbine , Services - Carry Out Insulation Test And Continuity Test Of Cables Of All Electrical Devices, Sub Devices And Sensors Associated With Zorya Control System As Required Vide Maint. Documents. Improve Insulation If Not Within Limits. , Services - Fitment Of All Slotted And Magnetic Chip Detectors Of Both Cgt And Bgt (Qty. 24 Nos.). Insulation Test And Continuity Test Of Cables Connected To All Slotted And Magnetic Chip Detectors Kcccm And Cc Of All Four Gts. Check Condition Of Cables And Replace Cables. , Services - Check Serviceability Of Бисс, Бусс And Бср Units. Repair/Refurbishment Of Units As Required. , Services - Check Serviceability Of Spark Plugs, Spark Plug Cables And Plasma Ignition Units Of Both Cgt And Bgt. Fitment Of Spark Plugs, Spark Plug Cables And Plasma Ignition Units Of Pcgt And Scgt. Check Condition Of Cables. , Services - Carry Out Insulation Test, And Continuity Test Of Supply And Control Cables Connected With Plasma Ignition Unit Of All Four Gts. Check Condition Of Cables , Services - Check Serviceability Of Длпг, Дпна1, Дпна2, Дтп1, Дтп2, Кпв, Кпф And Transducers And Valves. Repair/Refurbishment Or Replacement Of Transducers And Valves As Required. Transducer And Valves To Be Provided By Ss. , Services - Carry Out Insulation Test, Continuity Test And Connection Of Cables With Gt Control Station (Via Kcaл Connection Box) Of Длпг, Дпна1, Дпна2, Дтп1, Дтп2, Кпв, Кпф And Кзот Transducers And Valves. Check Condition Of Cable. , Services -Check Serviceability Of Дсо Transducer (Свм-Д) And Connection Of Transducer With Synchronizer Cbm-4. Check Condition Of Cables , Services - Check Serviceability Of Дмд, Дмд1, Дтаз, Кас, Кпт, Mck And Mct Units And Transducers. Fitment Of Дмд, Дмд1, Дтаз, Кас, Кпт, Mck And Mct Units And Transducers Of Both Cgts. Repair/Refurbish Transducers/Units. Ss To Provide New Transducers In Lieu Of Defective Ones For Replacement. , Services - Carry Out Insulation Test, Continuity Test And Connection Of Cables With Gt Control Station (Via Ксап) Of Дмд, Дмд1, Дтаз, Кас, Кпт, Mck And Mct Units And Transducers. Check Condition Of Cables. , Services - Carry Out Insulation Test, Continuity Test And Connection Of Cables From Connection Boxes Kcaл And Ксап To Gt Control Station. Check Condition Of Cables. , Services - Check Serviceability Of Пкц Unit Of All Four Gts And Connection Of Unit With Gt Control Station. Check Condition Of Cables. , Services - Fitment Of Kcpt Connector Of Cgts. Check Insulation Test, Continuity Test And Connection Of Cables From Kcpt Connection Box To Gt Control Station. Check Condition Of Cables. , Services - Check Serviceability Of Взх, Впх, Дсв, Кнзх, Ксзх, Кнпх, Кспх, Khcb And Kccb Micro-Switches And Manipulators. Connection Of All Micro-Switches And Manipulators With Gt Control Station (Via Kcpt Connection Box). Check Condition Of Cables. , Services - Fitment Of Кс429 Box Of Both Cgts. Insulation Test, Continuity Test And Connection Of Cables From Хтп Connector To Кстп Box, Кстп Box To Lts And Кстп Box To Рти Unit Of All Four Gts. Check Condition Of Cables. , Services - Carry Out Insulation Test, Continuity Test And Check Connection Of Cables From Рти Unit Gt Control Station And 127 V Db. Check Condition Of Cables. , Services - Check Serviceability Of Дорт Sensor. Carry Out Insulation Test, Continuity Test And Connection Of Cables From Sensor To The Opt Unit Via Ксдорт Connector For Both Cgt And Bgt. Check Condition Of Cables. , Services - Check Serviceability Of Opt Units (Qty- 04) And Connection Of Opt Unit With Gt Control Station, Дорт Sensor. Check Condition Of Cables. , Services - Check Serviceability And Fitment Of Rtds (Тсп 8040-5Ц.2821439-01) Of Тсд, Тсмод, Tcmop, Тскнд, Тсквд, Tctb, And Тстнд Of Both Cgt And Bgt. Carry Out Insulation Test, Continuity Test And Connection Of Cables Of All Rtds With Lts. Check Condition Of Cables. , Services - Fitment Of Kcao Connection Box Of Both Cgts And Connection Of Kcao With Associated Zorya Units I.E Altivar, Бисс, Бpr, Пк, Бвртпн And Gt Control Station. Check Condition Of Cables. , Services - Check Connection Of Cables From Gt Control Station To 27V Db, Lts, Rg Control Station, Kcao, Пкц, Хдсо, Ксап, Kcpt, Рти And Opt Units Check Condition Of Cables , Services - Carry Out Insulation Test, Continuity Test And Connection Of Cables Of All Four Gt Control Stations. Check Condition Of Cables. , Services - Check Serviceability Of Ignition Switches Of Both Cgt And Bgt And Insulation Test, Continuity Test And Connection Of Cables From Ignition Switch To Gt Control Station. Check Condition Of Cables. , Services - Fitment Of Connection Boxes Ям (Ся72-22 O/N), 1Kpm, 2Kpm (Ся42-20 O/N), Яп (Ся72- 22 O/N) Of Both Crgs At Designated Locations. Check Condition Of Cables. , Services - Check Serviceability And Fitment Of Тсг (Air Inlet) And Тсп (Gt Casing) Thermocouples (Txa 1172.5Ц2.821.679-6601) Of All Four Gts. Insulation Test, Continuity Test And Connection Of Cables Of Both Thermocouples To Respective Lts. Check Condition Of Cables. , Services - Check Serviceability And Fitment Of 1Bbk, 2Bbk, Ввпу, Впт, 1Bok And 2Bok Micro Switches Of Both Crgs. Carry Out Insulation Test, Continuity Test And Connection Of Cables From All Micro Switches To Ям Connection Box. Check Condition Of Cables. , Services - Check Serviceability And Fitment Of Oil Pressure Sensors (Дмр) Of Both Crgs (Qty- 08). Insulation Test, Continuity Test And Connection Of Cables From All Sensors To Ям Connection Box Of Crgs And Brgs. Check Condition Of Cables. , Services - Check Serviceability And Fitment Of Дот1, Дот2, 1Дс1, 1Дс2, 2Дс1, 2Дс2,1Дсв, 2Дсв And 2Дсш Transducers Of Both Crgs. Insulation Test, Continuity Test And Connection Of Cables From All Transducers To Respective Cbm Units. Check Condition Of Cables. , Services - Check Serviceability And Fitment Of 1Ддк, 2Ддк, 1Ддф, 2Ддф Transducers Of Both Crgs. Insulation Test, Continuity Test And Connection Of Cables From All Transducers To Ям Connection Box. Check Condition Of Cables. , Services - Check Serviceability And Fitment Of 1Kbk, 2Kbk, 1Kok, 2Kok, 1 Кф And 2Кфem Valves Of Both Crgs. Carry Out Insulation Test, Continuity Test And Connection Of Cables From All Em Valves To Ям Connection Boxes Of All Four Gts. Check Condition Of Cables. , Services - Carry Out Insulation Test, Continuity Test And Check Connection Of Cables From Ям Connection Box To Crg And Brg Control Stations. Check Condition Of Cables. , Services- Carry Out Insulation Test, Continuity Test And Connection Of Cables From All Cbm Units To Crg, Brg And Crga Control Stations Including Relay Units. Check Condition Of Cables. , Services- Check Serviceability And Fitment Of Дот1 And Дот2 Sensors. Carry Out Insulation Test, Continuity Test And Connection Of Cables From Sensors To Respective Пчу And Lts Units. Check Condition Of Cables. , Services- Carry Out Insulation Test, Continuity Test And Connection Of Cables Of All Пчу Units With All Four Gt And Rg Control Stations. Check Condition Of Cables. , Services- Fitment Of 1Kpm And 2Kpm Connection Boxes Of Both Crgs To Designated Locations. Carry Out Insulation Test, Continuity Test And Connection Of Cables Of 1Kpm And 2Kpm With Lts. Check Condition Of Cables. , Services- Check Serviceability And Fitment Of 1Tpm To 24 Tpm Rtds Of Both Crgs And Carry Out Insulation Test, Continuity Test And Connection Of Cables From Rtds To 1Kpm And 2Kpm Connection Boxes. Check Condition Of Cables. , Services- Check Serviceability Of Ввкп, Вокп, Ддкп, Ддфп, Кокп, Bbkл, Bokл, Ддфл, Кокл And Квкл Micro Switches Of Crga. Carry Out Insulation Test, Continuity Test And Check Connection Of Cables Of All Micro Switches And Em Valves With The Яп Connection Box. Check Condition Of Cables. , Services- Carry Out Insulation Test, Continuity Test And Connection Of Cables From Яп Connection Box To Crga Control Station. , Services- Check Serviceability And Fitment Of 1Дсв And 2Дсв Transducers. Carry Out Insulation Test, Continuity Test And Connection Of Cables Of Transducers To Cbm3 Unit. Check Condition Of Cables. , Services- Secure All The Cables With Cl S, Degutted For Replacement Of Gt And Rg. Carry Out Routine On The Cables And De- Carbonisation Of Connectors, Replace Worn Out Shielding/Screen And Cable Lugs. , Services- Repair All Known Defects Projected By Yard/Ss. , Services- Check Serviceability And Fitment Of Synchronizer Units (Qty- 08). Carry Out Repair/Refurbishment Of Units. , Services- Check Serviceability Of Рти Units (Qty- 04). Carry Out Repair/Refurbishment Of Pcbs And Unit. , Services- Serviceability Checks And Calibration Of All Mctb And Сду Type Sensors Of All Four Gts. Repair/Refurbish/Replace The Defective Sensors. Sensors To Be Provided By Ss. , Services- Serviceability Checks /Calibration Of 1Дмр Transducer, Впр Micro Switch, Rtds 13Тф To 22 Тф, Rtds 25Тф To Зотф, Kbш And Koш Em Valves. Repair/Refurbish/Replace The Defective Transducers/Em Valves. Spares To Be Provided By Ss. , Services- Check Serviceability Of Pressure Relay Крд2 (Рд) Of Gt And Rg (Qty- 08). Repair/Refurbishment The Units. , Services- Check Serviceability Of Тп1 Toтп10 Thermocouples (Txa 1368 Type). (Qty- 40 Nos.) , Services - Phase –Iii - Setting To Work Of Gt Local Control System Zorya Control System : Installation/ Re-Gutting Of All Control Stations, Jbs And Sensors Etc. On Proper Foundation After New Gt And Rg Is Installed On The Foundation. , Services- Carry Out Insulation Checks On Zorya System Devices, Gtcs, Rgcs, Etc. And Improve It If Found Low. , Services- Switch Ón Main And Reserve Power Supplies To System And Check For Smooth Change Over. Rectify Defects. , Services- Carry Out Setting To Work And Testing & Tuning Of Zorya Control System (As Per Oem Protocol Document) , Services- Undertake Complete Throttle Checks And Throttle Timing Checks On Both Mode I.E In Normal Mode & Emm Mode. , Services- Undertake Complete Functional Checks Of Gt Control Station (Ƃp-Relay Block). , Services- Check The Interlocks Of Cgt And Bgt. Check Condition Of Cables And Replaced As Required. Interlock Details Are As Follows: -I) Lpc/Hpc Rpm Less Than 300/500 Rpm.Ii)Intake Door Open.Iii) Main And Reserve Control Supply On.Iv) Ptn Switched On. V) Shaft And Pt Turning Device Off.Vi) Starter Supply On.Vii) Throttle Handle In Ir Position.Viii) Stop Cock Closed.Ix) No Protection In Gt/Rg.X) Selections Switch In Start Position. , Services- Check The Cold And Hot Protection Checks Of Cgt And Bgt As Per Maintenance Card. List Of Protection Appended Below: -I) Pt Over Speed Protection.Ii) Lpc Over Speed Protectioniii) High Exhaust Gas Temperature Protectioniv) Low Fuel Pressure Protection.V) Low Oil Pressure Protection Of Gt And Rg.Vi) Bypass Band Protection.Vii) Шпm Pressure Protection. , Services- Undertake Proving Of Interfaces Pertaining To Telemetric Channel Including Necessary Adjustments As Required. , Services- Carry Out Rectification Of All Observations During (Stw) Of All Units And Proving Of Zorya Control System , Services- Phase - Iv:- Zorya Control System: Harbour Acceptance Trials And Sea Acceptance Trials In Full Scope (As Per Oem Document).Acceptance Trials And Sea Acceptance Trials In Full Scope (As Per Oem Document). , Material- Pressure Sensor (Sensor Type Эда-1.6 Kgf/Cm²-01.C Class 0.5 ) , Material- Level Indicator (Sensor Type Уксу-67-0680-Φ25-Н-С-0-T1) , Material- Point Level Alarm (Sensor Type- Ftl51-D B82 Bb 5 Y9 A (L=700) , Material- Point Level Alarm (Sensor Type- Ftl51-D Gr2 Db 5 Y9 A (L=118)) , Material- Rtd (Sensor Type- Тсп/1-8040 Вп 001-01 ) , Material- Rtd (Sensor Type- Тсп/1-8040 Вп 004-47) , Material- Rtd (Sensor Type- Тсп/1-8040 Вп 001-37) , Material- Rtd (Sensor Type- Тсп/1-8040 Вп 001-46) , Material- Rtd (Sensor- Тсп/1-8040 Вп 003-08)
Basic Detail
Tender No GEM/2026/B/7733739
Bidding Type Tender
Location
City Mumbai
State Maharashtra
Key Dates
Publish Date 20 Aug 2026
Submission Date 27 Aug 2026
Open Date 27 Aug 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 38.34 Lakhs
Exemption Not Available
Document List
cddb9071-0d77-42ce-8b8e-519f9495ce91.pdf
1786525447.pdf
1786525450.pdf
1786530131.xlsx
FINAL_87f772cd-8c24-44c5-b2021787216722554_SMCOM.pdf
SafetyClau_b936dab9-848f-4660-99611786525082028_SMCOM.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Aug 27, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
pdf

cddb9071-0d77-42ce-8b8e-519f9495ce91.pdf

pdf

1786525447.pdf

pdf

1786525450.pdf

xlsx

1786530131.xlsx

pdf

FINAL_87f772cd-8c24-44c5-b2021787216722554_SMCOM.pdf

pdf

SafetyClau_b936dab9-848f-4660-99611786525082028_SMCOM.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders