TGGENCO - NSHES - Supply Of Different Ranges Of Analog Meters, Jyothi Make RE-300, RE-301 Auxiliary Relays, OEN Make Auxiliary Relays And Space Heaters At AMRPLIS, NSHES, Nagarjunasagar. , 96X96 MM Square Switch Board Pattern Flush/Panel Mounting, Taut Band Circular Scale (FSD 240 Deg), Moving Coil Rectifier Type, PT Operated Analog AC Voltmeter, Accuracy Class +/-1.0% To IS 1248, Scale Range:0-15KV AC, PT Ratio:11KV/Square Root 3/110V/Square Root 3 (Without Pts) , 96X96MM Square Switch Board Pattern Flush/Panel Mounting, Taut Band Circular Scale, (FSD 240 Deg) Moving Coil Rectifier Type A.C, CT Operated Analog Ammeter, Accuracy Class +/-1.0% To IS 1248, Scale Range:0-1500 Amps, CT Ratio:1500/5A (Without Cts) , 96X96 MM Square Switch Board Pattern Flush/Panel Mounting, Taut Band Circular Scale(FSD 240 Deg). Moving Coil DC Voltmeter, Accuracy Class +/- 1.0% To IS 1248, Basic Input Signal To The Meter:0-10V DC, But Scale Calibrated As 0-100HZ. , 96X96MM Square Switch Board Pattern Flush/Panel Mounting Taut Band Circular Scale, FSD 240 Deg, Analog MW Meter Suitable For Three Phase 2 Element 3 Wire System, Accuracy Class +/-1.5% To IS 1248 With Built In Transducer, Input Current:5A From CT Secondary, CT Ratio:1500/5A: Input Voltage:110Volts From PT Secondary, PT Ratio:11KV/Square Rro 3/110V/Square Rrot 3 (Without CT/PT), Scale Range:(-)25-0-25 MW (Centre Zero Scale) , 96X96MM Square Switch Board Pattern Flush/Panel Mounting Taut Band Circular Scale FSD 240 Deg, Analog MVAR Meter, Centre Zero Scale, Suitable For Three Phase 2 Element 3 Wire System, Accuracy Class +/-1.5% To IS 1248 With Built In Transducer, Current Coil:5A, CTR, 1500/5A: Voltage Coil:110V, PTR 11KV/Square Root 3/110V/Square Root 3 (Without CT/PT): Scale Range:(-)25-0-25 MVAR. , 96X96MM Square Switch Board Pattern Flush/Panel Mounting Taut Band Circular Scale FSD 240 Deg, Analog DC Voltmeter, Accuracy Class +/- 1.0% To IS 1248, Basic Input:4-20MA DC, But Scale Calibrated As 0-250V DC , 96X96MM Square Switch Board Pattern Flush/Panel Mounting Taut Band Circular Scale (FSD 240 Deg),Analogue Type DC Ammeter, Accuracy Class +/-1.0% To IS 1248, Basic Input:4-20 MA DC, But Scale Calibrated As 0-1000 Amps DC , 96X96MM Square Switch Board Flush Mounting Pattern Analog Power Factor Meter, FSD 240 Deg, Accuracy Class +/-2 Deg. Moving Coil Built In Transducer Type, Suitable For Three, Single Element System, Current Coil:5A, CTR 1500/5A, Potential Coil:110V, PTR 11KV/Square Root 3/110V/Square Root 3(Without CT/PT)Scale Range:0.5 Lag-1-0.5 Lead , 96X96MM Square Flush/Panel Mounting Switch Board Pattern Moving Coil DC Voltmeter, Centre Zero, Taut Band Circular Scale, FSD 240 Deg, Accuracy Class +/- 1.0% To IS 1248, Scale Range:15-0-15 Volts DC, Input Signal 4-20 MA DC. If Input Signal Is 4-20MA DC, Then (-)15V Is Equal To 4MA, 0 Is Equal To 12MA And (+)15V Is Equal To 20MA , 96X96MM Square Switch Board Flush/Panel Mounting Moving Coil DC Voltmeter(GV Position Indicator) Taut Band Circular Scale, FSD 240 Deg, Class +/- 1.0% To IS 1248, Basic Input:0-10V DC, But Scale Calibrated As 0-100% , 96X96MM Square Switch Board Flush/Panel Mounting Moving Coil DC Voltmeter(GV Limit Indicator) Taut Band Circular Scale, FSD 240 Deg, Class +/- 1.0% To IS 1248, Basic Input:0-10V DC, But Scale Calibrated As 0-100% , 96X96MM Square Switch Board Flush/Panel Mounting Vibrating Reed Type Frequency Meter, Suitable For 110V AC Operation, PT Operated, 11KV/110V,Double Scale, Resolution 1Hz, Scale Range:45-55 Hz, 13 Reeds Only(Without PT) , 96X96MM Square Switch Board Flush/Panel Mounting Moving Iron AC Double Scale Voltmeter, Accuracy Class 1.5%, PT Operated, Scale Range:0-250 KV AC, PT Rtaio:220KV/110V (Without PT) , 96X96MM Square Flush/Panel Mounting Switch Board Pattern, Taut Band Circular Scale FSD 240 Deg, Moving Coil Rectifier Type AC Ammeter, CT Operated, Accuracy +/- 1.0% To IS 1248, Range:0-400A ,CT Ratio:400/1A(Without CT) , 96X96MM Square Flush/Panel Mounting Switch Board Pattern Taut Band Circular Scale FSD 240 Deg, Moving Coil Rectifier Type AC Voltmeter, PT Operated, Class 1.0% To IS 1248 Range:0-250KV,PTR 220KV/Square Root 3/110V/Square Root 3(Without PT) , 96X96MM Square Switch Board Flush/Panel Mounting Taut Band Circular Scale, FSD 240 Deg, MW Meter With Built In Transducer Box, Suitable For Three Phase 2 Element 3 Wire System, Class:+/- 1.5% To IS 1248, Current Coil:1A, CTR 400/1A,Potential Coil:110V,PTR 220KV/Square Root 3/110V/Square Root 3(Without CT/PT) Scale Range:(-)100-0-100 MW , 96X96MM Square Switch Board Flush/Panel Mounting Taut Band Circular Scale, FSD 240 Deg, MVAR Meter With Built In Transducer Box, Suitable For Three Phase 2 Element 3 Wire System, Class +/- 1.5% To IS 1248, CTR 400/1A And PTR 220KV/Square Root 3/110V/Square Root 3(Without CT/PT, Scale Range:50-0-50MVAR , 96X96MM Square Taut Band Circular Scale AC Ammeter Scale Range:0-50A,CTR 50/1A(Without CT) , 96X96 MM Square Three Phase 2 Element 3 Wire MW Meter CTR 50/1A,PTR 220KV/Square Root 3/110V/Square Root 3(Without CT/PT) Scale Range:(-)5-0-15MW , 96X96MM Square Panel Mounting MVAR Meter, CTR 50/1A,PTR 220KV/Square Root 3/110V/Square Root 3 Scale Range(-)5-0-10 MVAR. , RELAY:TYPE:AUXILIARY:CONTACT ARRANGEMENT:4 C/O:COIL VOLTAGE:220 VDC, MAKE:JYOTI: MODEL:RE-300:ADDITIONAL INFORMATION:LED INDICATOR, Without Plug In Base , RELAY, TYPE:AUXILIARY, CONTACT ARRANGEMENT:4 C/O, COIL VOLTAGE:24 VDC, MAKE:JYOTI, MODEL:RE-301, ADDITIONAL INFORMATION:LED INDICATOR, Without Plug In Base , SPACE HEATER, 100W,Voltage:240V AC , RELAY ,Auxiliary, 115V DC, MODEL: 031-2R-3-115, COIL: 115V DC 10K OHM , COIL: 2- -10,NC: 4-5-8, COM: 1-8-11, NO: 3-7-9, Without Base, Make :OEN , 96X96MM SQUARE SWITCH BOARD FLUSH/PANEL MOUNITNG TAUT BAND CIRCULAR SCALE(FSD 240DEG),MOVING COIL DC AMMETER, BASIC INPUT:60MV,CLASS +/- 1.0% SCALE RANGE 0-1000AMPS DC,TO BE USED WITH EXTERNAL SHUNT OF 1000A/60MV (WITHOUT SHUNT).
BOQ
| Sl. No. | Item Name |
| 1 | 96X96 MM Square switch board pattern flush/panel mounting, taut band circular scale (FSD 240 Deg), moving coil rectifier type, PT operated analog AC Voltmeter, Accuracy class +/-1.0% to IS 1248, Scale range:0-15KV AC, PT Ratio:11KV/Square root 3/110V/Square root 3 (without PTs) |
| 2 | 96X96MM Square switch board pattern flush/panel mounting, taut band circular scale, (FSD 240 Deg) moving coil rectifier type A.C, CT operated analog Ammeter, Accuracy class +/-1.0% to IS 1248, Scale range:0-1500 Amps, CT Ratio:1500/5A (without CTs) |
| 3 | 96X96 MM Square switch board pattern flush/panel mounting, taut band circular scale(FSD 240 Deg). Moving coil DC Voltmeter, accuracy class +/- 1.0% to IS 1248, Basic input signal to the meter:0-10V DC, But scale calibrated as 0-100HZ. |
| 4 | 96X96MM Square switch board pattern flush/panel mounting taut band circular scale, FSD 240 Deg, analog MW meter suitable for three phase 2 element 3 wire system, Accuracy class +/-1.5% to IS 1248 with built in Transducer, Input current:5A from CT secondary, CT Ratio:1500/5A: Input voltage:110Volts from PT Secondary, PT Ratio:11KV/Square rro 3/110V/Square rrot 3 (without CT/PT), Scale range:(-)25-0-25 MW (Centre zero scale) |
| 5 | 96X96MM Square switch board pattern flush/panel mounting taut band circular scale FSD 240 Deg, analog MVAR meter, centre zero scale, suitable for three phase 2 element 3 wire system, accuracy class +/-1.5% to IS 1248 with built in Transducer, Current coil:5A, CTR, 1500/5A: Voltage coil:110V, PTR 11KV/Square root 3/110V/Square root 3 (without CT/PT): Scale range:(-)25-0-25 MVAR. |
| 6 | 96X96MM Square switch board pattern flush/panel mounting taut band circular scale FSD 240 Deg, Analog DC Voltmeter, Accuracy class +/- 1.0% to IS 1248, Basic input:4-20MA DC, but scale calibrated as 0-250V DC |
| 7 | 96X96MM Square switch board pattern flush/panel mounting taut band circular scale (FSD 240 Deg),analogue type DC Ammeter, accuracy class +/-1.0% to IS 1248, Basic input:4-20 MA DC, but scale calibrated as 0-1000 Amps DC |
| 8 | 96X96MM Square switch board flush mounting pattern Analog power factor meter, FSD 240 Deg, accuracy class +/-2 deg. Moving coil built in transducer type, suitable for three, single element system, current coil:5A, CTR 1500/5A, Potential coil:110V, PTR 11KV/Square root 3/110V/Square root 3(without CT/PT)Scale range:0.5 Lag-1-0.5 Lead |
| 9 | 96X96MM Square flush/panel mounting switch board pattern moving coil DC Voltmeter, centre zero, taut band circular scale, FSD 240 deg, Accuracy class +/- 1.0% to IS 1248, Scale range:15-0-15 Volts DC, Input signal 4-20 MA DC. If input signal is 4-20MA DC, then (-)15V is equal to 4MA, 0 is equal to 12MA and (+)15V is equal to 20MA |
| 10 | 96X96MM Square switch board flush/panel mounting moving coil DC Voltmeter(GV Position Indicator) taut band circular scale, FSD 240 Deg, class +/- 1.0% to IS 1248, Basic input:0-10V DC, but scale calibrated as 0-100% |
| 11 | 96X96MM Square switch board flush/panel mounting moving coil DC Voltmeter(GV Limit Indicator) taut band circular scale, FSD 240 Deg, class +/- 1.0% to IS 1248, Basic input:0-10V DC, but scale calibrated as 0-100% |
| 12 | 96X96MM Square switch board flush/panel mounting Vibrating Reed type Frequency meter, suitable for 110V AC operation, PT operated, 11KV/110V,Double scale, resolution 1Hz, Scale range:45-55 Hz, 13 Reeds only(without PT) |
| 13 | 96X96MM Square switch board flush/panel mounting Moving Iron AC Double scale Voltmeter, accuracy class 1.5%, PT operated, Scale range:0-250 KV AC, PT Rtaio:220KV/110V (without PT) |
| 14 | 96X96MM Square flush/panel mounting switch board pattern, taut band circular scale FSD 240 deg, moving coil rectifier type AC Ammeter, CT operated, Accuracy +/- 1.0% to IS 1248, Range:0-400A ,CT Ratio:400/1A(without CT) |
| 15 | 96X96MM Square flush/panel mounting switch board pattern taut band circular scale FSD 240 deg, moving coil rectifier type AC Voltmeter, PT operated, Class 1.0% to IS 1248 Range:0-250KV,PTR 220KV/Square root 3/110V/Square root 3(without PT) |
| 16 | 96X96MM Square switch board flush/panel mounting taut band circular scale, FSD 240 deg, MW meter with built in Transducer box, suitable for three phase 2 element 3 wire system, Class:+/- 1.5% to IS 1248, Current coil:1A, CTR 400/1A,Potential coil:110V,PTR 220KV/Square root 3/110V/Square root 3(without CT/PT) Scale range:(-)100-0-100 MW |
| 17 | 96X96MM Square switch board flush/panel mounting taut band circular scale, FSD 240 deg, MVAR meter with built in Transducer box, suitable for three phase 2 element 3 wire system, class +/- 1.5% to IS 1248, CTR 400/1A and PTR 220KV/Square root 3/110V/Square root 3(without CT/PT, Scale range:50-0-50MVAR |
| 18 | 96X96MM Square taut band circular scale AC ammeter Scale range:0-50A,CTR 50/1A(without CT) |
| 19 | 96X96 MM Square three phase 2 element 3 wire MW meter CTR 50/1A,PTR 220KV/Square root 3/110V/Square root 3(without CT/PT) Scale range:(-)5-0-15MW |
| 20 | 96X96MM Square panel mounting MVAR meter, CTR 50/1A,PTR 220KV/Square root 3/110V/Square root 3 Scale range(-)5-0-10 MVAR. |
| 21 | RELAY:TYPE:AUXILIARY:CONTACT ARRANGEMENT:4 C/O:COIL VOLTAGE:220 VDC, MAKE:JYOTI: MODEL:RE-300:ADDITIONAL INFORMATION:LED INDICATOR, without plug in base |
| 22 | RELAY, TYPE:AUXILIARY, CONTACT ARRANGEMENT:4 C/O, COIL VOLTAGE:24 VDC, MAKE:JYOTI, MODEL:RE-301, ADDITIONAL INFORMATION:LED INDICATOR, without plug in base |
| 23 | SPACE HEATER, 100W,voltage:240V AC |
| 24 | RELAY ,auxiliary, 115V DC, MODEL: 031-2R-3-115, COIL: 115VDC 10K OHM , COIL: 2- -10,NC: 4-5-8, COM: 1-8-11, NO: 3-7-9, without base, make :OEN |
| 25 | 96X96MM SQUARE SWITCH BOARD FLUSH/PANEL MOUNITNG TAUT BAND CIRCULAR SCALE(FSD 240DEG),MOVING COIL DC AMMETER, BASIC INPUT:60MV,CLASS +/- 1.0% SCALE RANGE 0-1000AMPS DC,TO BE USED WITH EXTERNAL SHUNT OF 1000A/60MV (WITHOUT SHUNT). |