Tender For Wiring Of Newly Constructed Pre Fab Structure (To Be Used As Gym ) Of Officers Institute Under Cswt Bsf Indore.
Tender Value
1.95 Lakhs
Estimated cost
Bid Submission
31 Aug 2026
10 days left
EMD
3919
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Indore → Madhya Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Wiring Of Newly Constructed Pre Fab Structure (To Be Used As Gym ) Of Officers Institute Under Cswt Bsf Indore.
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthingthe point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group C |
| 2 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.a) 2 X 1.5 sq.mm +1 X 1.5 sq.mm Earth wire |
| 3 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required b) 2 X 2.5 sq.mm +1 X 2.5 sq.mm Earth wire |
| 4 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required c) 2 X 4.0 sq.mm +1 X 4.0 sq.mm Earth wire |
| 5 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.a) 3 x 1.5 sq. mm |
| 6 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. b) 3 x 4 sq. mm |
| 7 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a) 20 mm |
| 8 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. |
| 9 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch,connections etc. as required. |
| 10 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) .6 way , Double door |
| 11 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) .8 way , Double door |
| 12 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 13 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 Amp |
| 14 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amp |
| 15 | Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 16 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 17 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 18 | Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I.bolts, nuts, chuck nuts and spring washers etc.complete as required. |
| 19 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 20 | Brush Less Direct Current (BLDC) Fan withRemote Supply, Installation, Testing and Commissioning ofceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value(CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR,PVC insulated copper conductor single core cable and earthing etc. as required. 1400mm, service value ≥ 6.0 CM/Min/Watt, airdelivery 245 CM/Min (Minimum) |
| 21 | SITC of 200/225/250 mm PVC body fresh air fan in the existing opening including making good the damage i/c providing and fixing suitable lower/shutters & connection etc as req. compatible to Havells make model No Ventil air DX FHVVEDXWHT08 Acceptable to Crompton/ Havells /Bajaj/ Usha or equivalent. |
| 22 | Supplying and installation of 72 watt 3 in 1 colour (warm,natural and cool day) 4CCT LED tube light fitting 4 feet long iucluding making connection etc as required compatible to nortek Acceptable make- CG / Bajaj / Havells / Philips/HPL/Syska/C&S directly on ceiling/wall, including connection with 1.5 sqmmFRLS PVC insulated, copper conductor, single core cable and earthing etc as required. |
| 23 | Providing and Laying of one number XLPE insulated and PVC sheathed, armoured aluminium power cable of 1.1 KV Grade of size 2x 25 sqmm direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering , conf to IS: 7098 part-1 of make- Havells/Polycab/KEI/Plaza/Gloster/RR. |
| 24 | Supplying and Laying of one number XLPE insulated and PVC sheathed aluminium conductor power cable of 1.1 KV grade of size 2x25 sq.mm in the existing masonry/ open duct as required. Conf. to IS:7098 part - I of make Havells/Polycab/KEI/Plaza/Gloster/RR |
| 25 | Supplying and Laying of one number XLPE insulated and PVC sheathed aluminium conductor power cable of 1.1 KV grade of size 2 X 10 sq.mm direct in ground in including excavation and refilling the trench etc. as required , but excluding sand cushioning and protective covering make conf to IS: 7098 part-1 of make Havells/Polycab/KEI/Plaza/Gloster/RR |
| 26 | Supplying and Laying of one number XLPE insulated and PVC sheathed aluminium conductor power cable of 1.1 KV grade of size 2 X 10 sq.mm in the existing masonry/ open duct as required. Conf. to IS:7098 part - I of make Havells/Polycab/KEI/Plaza/Gloster/RR Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 20, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 31, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysSep 02, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender