Drinking Water Supply and Sanitation Government Departments Closing in 4 days TDR #57107910

Tender For Construction Of Mukhyamantri Solar Lift Irrigation Scheme At Patratu Village,Block-Kanke,District-Ranchi.

Issued by Government Departments · Ranchi, Jharkhand
Tender Value
1.07 Crore
Estimated cost
Bid Submission
27 Aug 2026
4 days left
EMD
1.08 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ranchi → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Mukhyamantri Solar Lift Irrigation Scheme At Patratu Village,Block-Kanke,District-Ranchi.

BOQ

Name of Work:- Construction of Mukhyamantri Solar Lift Irrigation Scheme At Patratu Village,Block-Kanke,District-Ranchi.
Sl. No. Item Description
1Please Enable Macros to View BoQ information
2Solar Module Mounting (Galvanised Steel) surface structure (for 10 KW) having Hot deep galvanised of Zinc thickness 80micron and as per IS4759 with C Channel & anti theft with nut bolt of grade SS304,which should also withstand high wind velocity upto 150km/hr or as per MNRE.
310kWp SPV module of 330wP or higher rating, which must have Specification as per IS 14286/IEC 61215 .The module must have to quilify IS/IEC 61730 part I & II (or having mechanical load test of 5400Pa) for safety purpose.Module to Module wattage mismatch in SPV Array shall be +/-3% and to qualify IEC TS 62804-:2015 for the detection of potential induced degradation and warranted for output wattage not less than 90% in 10yrs and 80% at the end of 25yrs as per MNRE.
4USPC controller with SPV module/VFD integrated with GPRS,having MPPT ,Protection IP 65 or above as per MNRE to run 10HP AC induction motor pump set .
5Solar cable 4 mm² used as per IS 694 or as per MNRE.
6copper cable 95 mm² used as per IS 694 or as per MNRE.
7Copper cable 16 mm² for earthing as per IS 694 or as per MNRE.
8Supplying and commissioning of earthing and lighting arrestor and surge protction as per IS 3043,IEC62305-3 and IEC 63227 for 10 HP AC induction motor pump set.
910 H.P. A.C induction motor Solar pump set of having performance with respect to Total Head,Maximum Current, Capacity, Voltage Range etc as per MNRE guidelines.
10Miscllaneous Accessories for Installation of 10H.P. A.C induction motor Solar Pump(L.S)
11Supplying,installation and commissioning Charge of module and Structure for 10kW.
12Maintenance for atleast 5 years or as per MNRE guidline for 50kw spv module and 5 no10 Hp. A.C solar pump with all asscessories.
13Supplying 100 mm dia C.I foot valve having single leather flap and gun metal seating .Valve shall be fixed on suction side of pump as per requirement including jointing meterial and hardwear . (Common Part-A, M-1063, (pg-134)
14G.I fittings (conforming to I.S.- 1879) . 100 mm dia G.I. Bend - (Common Part-A, M-930(A-ix), (pg-92)
15G.I fittings (conforming to I.S.- 1879.) 100 mm x 100mm long (4\\" dia G.I. Nipple) (Common Part-A M-930(J-ix), (pg-94)
16G.M Non- Return valve Horizontal (ISI marked)100 mm dia wt. non less then 1.80kg.(Common Part -A M-926(ix) (pg-91)
17G.I fittings (conforming to I.S.- 1879.)100 mm G.I. Reducing Tee Plain(taking larger dimention). Common Part-A, M930,(D)-(viii), Pg-92
18Providing and supplying in standard lengths High density polyethylene pipe (HDPE Pipe) confirming to IS 4984/14151/12786/13488 (Latest revison with necessary jointing materials like mechanical connector i.e thread/insert joint/quick release coupler joint/compression fitting joint or flanged joints excluding coupler/specials and taxes.) Note:- The rates are F.O.R at work site in Jharkhand including Royalty, inspection charges and other taxes but excluding GST & C.P., H.D.P.E pipe of materials grade-PE80-PN10(dia 200 mm), (Common Part-A, M-1028, Pg-104)
19(A) Providing and supplying ISI Mark CI D/F reflux valve (Non return valves) of 200 mm dia with inspection charges, unloading from railway wagon, loading into truck transportation up to departmental stores /site unloading stacking etc. complete reflux valves as per IS 5312 part 1(1984) Without bypass arrangment-PN-1, (200 MM) (Common Part-A, M1039, Pg-118)
20Providing and supplying in standard lengths High density polyethylene pipe (HDPE Pipe) confirming to IS 4984/14151/12786/13488 (Latest revison with necessary jointing materials like mechanical connector i.e thread/insert joint/quick release coupler joint/compression fitting joint or flanged joints excluding coupler/specials and taxes.) Note:- The rates are F.O.R atwork site in Jharkhand including Royalty, inspection chargesand other taxes but excluding GST & C.P., H.D.P.E pipe of materials grade-PE80-PN10(dia 110 mm), (Common Part-A, M-1028, Pg-104)
21(B) Providing double flange sluice valve( Size 50mm to 1200 mm) confirming for IS- 2906/14846 including worn gear arrangements as per test pressure stailess steel spindle, caps, transportation etc. all complete.( with bypass arrangement PN-1), (100 mm dia) (Common Part - A , M1039(B)4, Pg-120)
22G.I fittings (conforming to I.S.- 1879),100 mm dia G.I Socket Plain(Taking larger dimension),(Common Part - A, M930 E-(ix)Pg-93)
234\\" dia M.S. Suction pipe/Delivery pipe (C.E. Lt-2873, DT-31/12/2013, (item-1)
244\\" dia G.I. Flange (C.E. Lt-2873, DT-31/12/2013, (item-39)
254\\" x 8\\"/10\\" Reducer (C.E. Lt-2873,dt-31/12/2013, item-96)
268\\" M.S. Pipe (C.E. Lt-2873,dt-31/12/2013, Sl. No.-1)
278\\" Flange (C.E. Lt-2873,dt-31/12/2013, item-41)
288\\" M.S. bend(C.E. Lt-2873,dt-31/12/2013, item-46)
294\\" PVC Tee(C.E. Lt-2873, dt-31/12/2013, Sl.No.-105)
304\\" PVC Tail piece(C.E. Lt-2873, dt-31/12/2013, Sl.No.-65)
314\\" PVC Bend (C.E. Lt-2873, dt-31/12/2013, Sl.No.-111)
32Solvent Cement(Sl No.134) (C.E. Lt-2873,dt-31/12/2013, item-134)
33M-Seal(Sl No.136) (C.E. Lt-2873,dt-31/12/2013, item-136)
34Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item - A) and disposal of excavated earth as obtained to a distance upto 50 M. including all lifts, levelling, ramming the foundation trenches, removing roots of trees, shurbs all complete as per approved design, building specification and direction of E/I. (5.1.1) BCD PART B
35Earthwork in excavation in foundation trenches in ordinary soil ( vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling, ramming the foundation treanches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/I. Extra for earthwork in hard soil as per specification and direction of E/I. ( vide classification of soil item-B)(5.1.1 + 5.1.2 B.C.D)
36Filling in foundation trenches and plenth in layers not exceeding 150 mm thick well watered, rammed fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume) (5.1.7. BCD PART B.)
37Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150 mm thick with all leads and lifts including cost of all material, labour, royalty and taxes all complete as per building specification and direction of E/I. (Mode of measurement compacted volume) (5.1.10) BCD
38Providing designation 75A brick work in C.M. (1:6) in Foundation and Plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints, cost of screening materials, raking out joints to 15 mm depth, curing, taxes and royalty all complete as per specification and direction of E/I. (5.2.3) BCD PART B
39Providing designation 75A brick work in C.M. (1:4) in Superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints, cost of screening materials, scaffolding, raking out joints to 15 mm depth, curing, taxes and royalty all complete as per specification and direction of E/I. (5.2.10) BCD PART B
40Providing designation 75 B brick work in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, scaffolding, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I. (5.2.14) BCD PART B
41Providing random rubble stone masony in cement mortar (1:4) in superstructure with hammer dressed stone of less than 0.03 M3 in volume and clean coarse sand of F.M. 2 to 2.5 including cost of screening, raking out joints to 20 mm depth, curing, taxes and royalty all complete as per budiling specification and direction of E/I. (5.2.31) BCD PART B
42Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) (5.3.1.2) BCD PART B
43Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size). (5.3.5) BCD PART B
44Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) (5.3.9.1) BCD PART B
45Providing designation 75A brick work in C.M. (1:6) in Superstructure with approved quality of clean coarse sand F.M. 2 to 2.5 including providing 10 mm thick mortar joints , costs of screening ,materials , scaffolfing, raking out joints to 15mm depth curing ,taxes and royalty all complete as per building specification and direction of E/I. (5.2.11 BCD PART B)
46Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) (5.3.10) BCD PART B
47Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). (5.3.11) BCD PART B
48Providing shuttering, including strutting, propping etc. and its removal after use in foundation work as per specification and direction of E/l. (5.3.17 WRD PART B.)
49Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete. (BCD-5.3.17.1)
50Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform (BCD-5.3.17.3)
51Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers (BCD-5.3.17.5)
52Centering and shuttering including strutting, propping etc. and removal of form for column, pillars, piers, abutments, posts and struts (BCD-5.3.17.6)
53Providing shuttering, including strutting, propping etc. and its removal after use in super structure portion of various components of dam work as per specification and direction of E/l. (5.3.18 WRD PART B.)
54Providing 25 mm precast cement concrete jali1:2:4 (1 cement:2 coarse sand (zone III):4 graded stone aggregate 6 mm nominal size, reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening, cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. excluding platering of the joints, sills and soffits as per building specification and direction of E/l.. (5.3.21.3) BCD PART B
55Providing Tor steel reinforcement of 8 mm dia rods as per approved design and drwaing with cutting bending and binding with annealed wire with cost of wire removal of rust, placing the rods in position (including carraige of bars to work site) all complete as per building specicication and direction of E/I. (5.5.4) BCD PART B (TMT Fe 500 (only valid for Tata & sail Steel )
56Providing Tor steel reinforcement of 10mm,12mm,& 16mm. dia bars as per approved design and drawing with cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position (including carraige of bars to work site) all complete as per building specification and direction of E/I. (a) 10 mm (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)}) (5.5.5) BCD PART B
57Providing Tor steel reinforcement of 10mm,12mm,& 16mm. dia bars as per approved design and drawing with cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position (including carraige of bars to work site) all complete as per building specification and direction of E/I. (b) 12mm (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)}) (5.5.5) BCD PART B
58Supplying, Fitting and fixing M.S grill made of 20 x 6mm M.S. flat/square bar as per approved design and drawing properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. (where material is not supplied by the department) (5.5.12) BCD PART B
59Labour for fitting and fixing barbed wire fencing in six rows,horizontal upto a height of 1.85 M and two diagonals including fixing of post in cement concrete at 2.5 M centres including cost of staples (but excluding the cost of cement concrete angle iron post, its cutting and making holes, nuts and bolts) all complete as per building specification and direction of E/I. (5.5.22) BCD PART B
60Drilling 6mm dia holes MS angle iron for fixing of staples etc as as per building specification and direction of E/I. (5.5.23) BCD PART B
61Labour for cutting of MS angle iron post to require length, one end splitted as fishtailed in a length of 150mm complete as per building specification and direction of E/I. (5.5.24) BCD PART B
62Supplying, fitting and fixing 20 gauge GCI sheet gate fitted on MS angle frame of size 60x60x6mm. including cost of fabrication providing necessary locking arrangement with haskal and domny duly fixed in PCC (1.2.4) blocks of required size applying a priming red lead paint over steel work taxes all complete as per drawing specification and direction of E/I. (5.5.29) BCD PART B
63Supplying, Fitting and fixing M.S grill gate with M.S. grills made of 20 x 6mm M.S. flat or 16 mm M.S. Square bars fitted on 25 x 25 x 6 mm M.S. Angle frame including cost of fabrication providing necessary locking arragements with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size, applying and priming red lead paint over steel work, taxes all complete as per specification and direction of E/I. (when steel is not supplied by the deptt.) (5.5.30) BCD PART B
64Providing 50mm thick cement concrete flooring (1:2:4) with 20mm to 6mm size graded stone chips finished with flooring coat of neat cement in panels including cost of curing finishing the surface smooth by rubbing with carborandum stone ,taxes and royalty with all complete as per building specification and direction of E/I. (5.6.9 BCD PART B)
65Supplying and laying sand filter blanketing in horizontal portion of the dam as per design and drawing with watering, compaction including cost of sand, royalty all taxes etc. but excluding the cost of carriage as per specification and direction of E/l. (5.6.1)Common Part-A
66Providing designation 75B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. (5.6.3) BCD PART B
67Supplying and laying gravel filter (size 5mm to 15mm) in filter blanket and in the toe drain (in horizontal portion) of the dam as per design, drawing including the cost of materials royalty and all taxes etc. but excluding the cost of carriage all as per specification and direction of E/l.. (5.6.2) Common Part - A
68Supplying and laying good quality of stone metal filter (20mm to 63mm size) in the rock toe, heel trenches, toe drain as per design and drawing including the cost of materials, royalty all taxes etc. but excluding the cost of carriage all complete as per specification and direction of E/l. (5.6.3) Common Part - A
69Supplying laying boulder in rock toe heel trenches of the dam as per design, drawing including the cost of materials royalty and taxes etc. but excluding the cost of carriage all complete as per specification and direction of E/l. (5.6.4 ) Common Part - A
70Providing 12mm thick cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. (5.7.1 BCD PART B.)
71Providing 12mm thick cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening, curing, with all leads and lifts of water scaffolding, taxes and royalty all complete as per building specification and dirtection of E/I.. (5.7.2) BCD PART B.
72Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screeing, curing with all leads and lifts of water scaffolding, taxes and royalty all complete job as per building specification and direction of E/I. (5.7.3) BCD PART B
73Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screeing curing with all leads and lifts of water scaffolding, taxes and royalty all complete as per building specification and direction of E/I. (5.7.6) BCD PART B
74Providing 1.5mm cement punning including curing, carriage of water with all leads and lift as per building specification and direction of E/I. (5.7.11) BCD PART B
75Providing 25mm thick cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening, curing, with all leads and lifts of water scaffolding, taxes and royalty all complete as per building specification and direction of E/I. (5.7.12 BCD PART B)
76Providing two coats of snowcem of approved shade and make over a coat of cement primer on new surface including prepairing the plastered surface smooth with sand paper, scaffolding, curing and taxes all complete as per building specification and direction of E/I. (5.8.24) BCD PART B
77Providing primer one coat of red lead paint of approved make over new steel surface including prepairing the surface after cleaning removing, dust, dirt, scales, smokes and grease and cleaning the surface throughly including cost of scaffolding and taxes all complete buiding speciciation an direction of E/I. (Mode of measurement area shall be multiplied by the co-efficient as indicatted in building specfication) (5.8.41) BCD PART B
78Providing two coats of painting with ready mixed paint of approved shade and make over steel surface including cleaning the surface throughly scaffolding and taxes all compelete as per specification and direction of E/I. (5.8.43) BCD PART B
79Earth work in filling foundation trenches or back filling of masonry structures with suitable earth in layers not exceeding 150mm thick well watered, rammed and fully compacted and finally dressed with earth obtained from excavation of foundation trenches and kept at a lead of 30m and initial lift of 1.5m complete as per specification and direction of E/I. (6.1.16) WRD PART B
80Providing coarse clean local sand in filling in foundation trenches including ramming, watering, royalty and all other taxes complete job as per specification and direction of E/I. (7.1.37) WRD PART B
81Providing bricks flat soling with designation 75 A bricks, joints filled with coarse sand of approved quality including royalty and all taxes,all complete job as per specification and direction of E/I. (7.7.14) WRD PART B
82Labour charge for fitting and fixing of 125 mm to 150 mm dia C.I. foot valve or flange (all standard make with or without check) in position with respective 125 mm to 150 mm dia G.I. Pipe including supply of 22 mm thick rubber packing and proper size of nut and bolts of hard steel, including making of valve seat etc. complete job including carriage of materials from site godown to work site as per specification and direction of E/I. (8.1) WRD Part B
83Labour charge for fitting & fixing 125 mm to 150 mm dia G.I. M.S. Bend of any degree with 125 mm G.I. or M.S. Pipe (All of standard make) including threading, if required and carriage to site godown to work site all complete job leak proof as per specification and direction fo E/I. (8.5) WRD Part B
84Labour charge for fitting & fixing 200 mm/250 mm G.I. reducing socket (all of standard make) in position including cost of hard steel nuts and bolts of proper size, rubber packing, safeda etc. including cost of carriage from site godown to work site, tools and plant etc. all complete job leak proof as per specification and direction of E/I.(Both end fitting) (8.9) WRD Part B
85Labour charge for fitting & fixing 150mm dia. sluice or N.R valve (all of standard make) in position (both ends) in in position including cost of hard steel nut and bolt of proper size in 10mm thick rubber packing, safeda etc. and also including the cost of carriage from site godown to work site, tools and plants etc. all complete leak proof as per specification and direction of E/I. (WRD 8.15)
86Labour charge for fitting and fixing 600mm x 300mm C.I. grating in the steining walls of intake well as per specification and direction of E/I. (8.59) WRD Part B
87L/C for fitting and fixing of 150 mm dia. all pressure P.V.C tail piece (all of standard make) in position including carriage from site godown to work site, tools & plants etc. all complete job as per specification and direction of Engineer-in-charge.(WRD 8.62)
88L/C for fitting & fixing 150mm x 150mm x 150mm PVC Tee (all of standard make) of all pressure in position including carriage from site godown to the work site, tools and plant etc. all complete job as per specification and direction of E/I.(WRD 8.67)
89Labour charge for threading of pipes 200mm dia. including carriage from site godown to work site as per specification and direction of E/I. - (WRD 8.88)
90Providing Iron and steel material angle size in mm (75X75X8),Common part A (M - 195, P-39),b(iii) .
91Providing Barbed wire of 4 point , 2 ply 12 SWG , 150 mm apart. (M-215, P - 56 SL. No. 31 Common Part - A)
92Hire charge of diesel operated pump for bailing out of water during construction all complete as per building specification and direction of E/l. (PM 29 WRD Part B, P - 83, Sl.No. - 10)
93Supplying labours and tools for laying and jointing H.D.P.E. pipes in trenches and making butt welded joint, supplying heating mirror, jack etc. and providing night gurad barrier and red light to safe guard against ancident, all complete as per specification and direction of E/I. (b) 110/100mm dia. (3.1.37b) PHED Part B
94Supplying labour and tools for laying and jointing A.C. Pressure pipe in trenches (as per I.S.S.) with G.I. detachable joints with \\"O\\" rings, including providing night guard barrier and red light to safe guard against accident all coplete as per specification and direction of E/I. ((3.1.38 e ) PHED PART B.200 mm I.D.
95Supplying labour and equipment for digging well vide classification of soil item - A including removing the spoils to a safe distance upto 50 M from the edge of the well all complete job as per specificition and direction of E/l. (3.1.64) PHED PART B(i) E/W up to 3 metre depth below G.L.
96(ii) 3M to 4M - p/4d2h
97(iii) 4M to 5M - p/4d2h
98(iv) 5M to 6.00M - p/4d2h
99(v) 6M to 6.25M - p/4d2h
100Supplying materials and labour for providing R.C.C. Well curb (1:2:4) including centering and shuttering but excluding the cost of reinforcement all complete as per specification and direction of E/I. (3.1.68 Phed. Part B)
101Supplying materials and labour for fixing 20mm dia M.S. bar steps in steining wall of 0.30 M interval and staggered in (1:2:4) cement concrete including scaffolding and curing etc. all complete as per specification and direction of E/I. (3.1.71) PHED PART B
102.Cost of carriage of materials : Cement (6 SR + 00K )
103Sand : ( 25 SR + 02 K )
104Stone Chips : (30 SR + 00 K )
105Boulder : (30 SR + 00 K )
106Stone Metal (30 SR + 00 K )
107Bricks (15 SR + 00 K )
108Point wiring in PVC conduit, with Piano Type switch. Wiring for Light point/fan point/exhaust fan point/call bell point, with 1.5 sq mm FR PVC insulated copper cunducter sigle core in surface/recessed PVC conduit, piano type switch, phenolic laminated sheet with suitable size PVC/MS box etc. as required. 1.1 (1.1.1 Group A) Energy PART B
109S.I.T.C. of floowing rating LED Street lighting laminarie with pressure die cast housing and toughened glass cover, (IP 66 protection) in existing pole/pipe for supply voltage 110 - 270 V AC, 50 Hz, Luminarie shall be confirmed to IS:10322 part - 5/ Section - 3 and shall be complete with all necessary accessories as required.30W Led Street Light. 9.1 (9.1.3) Energy PART B.
11063A TPM 415/440 V main switch .( C.E.Lt-2873, dt-31.12.2013)
111Voltmeter - 500 V ( C.E.Lt-2873, dt-31.12.2013)
112Ampere Meter - 60 A ( C.E.Lt-2873, dt-31.12.2013)
113Wooden panel board for fitting main switch, volt meter, amp. meter etc. ( C.E.Lt-2873, dt-31.12.2013)
1147/20 Copper Wire, ( C.E.Lt-2873, dt-31.12.2013).
1157/18 Copper Wire ( C.E.Lt-2873, dt-31.12.2013)
116Batten Holder. ( C.E.Lt-2873, dt-31.12.2013)
1175 Ampere switch.( C.E.Lt-2873, dt-31.12.2013)
118100 Watt Bulb.( C.E.Lt-2873, dt-31.12.2013)
119PVC Tape.( C.E.Lt-2873, dt-31.12.2013)
1201½\\" P.V.C. Flexible Pipe.( C.E.Lt-2873, dt-31.12.2013)
12163A Copper bushbar - 3 Phase 4 Pole( C.E.Lt-2873, dt-31.12.2013)
122Goods & Services Tax (G.S.T.) from SI. No.- 01 to SI. No.- 105 @ 18%
1231% Labour Cess

AI Tender Summary

OUR REF NO 57107910
AUTHORITY Government Departments
TENDER VALUE 1.07 Crore
LAST DATE 27-08-2026
Authority
Authority Name Water Resources Department
Work Description Tender for Construction Of Mukhyamantri Solar Lift Irrigation Scheme At Patratu Village,Block-Kanke,District-Ranchi.
Basic Detail
Tender No WRD/MID/RANCHI/BD/SLI-06/26-27
Bidding Type Tender
Location
City Ranchi
State Jharkhand
Key Dates
Publish Date 20 Aug 2026
Submission Date 27 Aug 2026
Open Date 29 Aug 2026
Finance
Tender Value 1.07 Crore
Tender Fee 10000
EMD 1.08 Lakhs
Exemption Not Available
Document List
5c8a6bf7-6ab6-426a-98d3-2ff1849520a8.html
BOQ_159002.xls
DOCUMENTS.pdf
Tendernotice_1 (19).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Aug 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

5c8a6bf7-6ab6-426a-98d3-2ff1849520a8.html

xls

BOQ_159002.xls

pdf

DOCUMENTS.pdf

pdf

Tendernotice_1 (19).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders