Housing Urban and Rular Development Government Departments Closing in 6 days TDR #57107520

Tender For Augmentation/Restoration Of Trout Rearing Fish Farm Chawalgam Adv Cost Rs. 55.734 Lacs Incld: 18% Gst

Issued by Government Departments · Kulgam, Jammu and Kashmir
Tender Value
55.73 Lakhs
Estimated cost
Bid Submission
02 Sep 2026
6 days left
EMD
1.11 Lakhs
Bank guarantee accepted
Document Fee
1600
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kulgam → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Augmentation/Restoration Of Trout Rearing Fish Farm Chawalgam Adv Cost Rs. 55.734 Lacs Incld: 18% Gst

BOQ

Name of Work:- Augmentation/Restoration of Trout Rearing Fish Farm Chawalgam Adv cost Rs. 55.734 Lacs incld: 18% GST
Sl. No. Item Description
1Main Building
2Engagement of JCB and tractor,labouretc for dressing and disposal of waste material etc
3Tractor
4Labour
5Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil :
6P/L stone soling nallah hand packed in bed including all carriages etc complete
7Providing/ laying position cement concrete of specified grade excl. cost of centering and shuttering all work upto plinth level 1:4:8 ( stone agg. 40mm nom. Size)
8Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
9Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
10Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
11Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in superstructure above lonth level including curing in : 6.1.1 Cement lime mortar 1:1:6 ( 1 cement : 1 lime putty : 6fine sand)
12Supplying and filling of RBM in plinth incl. spreading, dressing,watering with all carrriage etc complete
13Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): Imported wood
14Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
15Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
16Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20mm nominal size stone aggregate.
17Providing and fixing of 35mm wide glass strips in level incld all carriage and wastages complete
18Centering and shuttering incl. strutting , prooping etc and removal of same using ply board for finished surface
19Foundations, footings, bases for columns Foundation
20Lintel, beams, plinth beams, girders, bressumers and cantilevers.
21Suspended floors, roofs, landings, balconies and access platforms.
22Providing & Fixing Panelled or panelled & glazed shutters for doors , windows, incl. ISI marked butt. Hinges with necessary screws ( 30 mm thick Imported wood K.D/Silver or as directed) including 4mm glass pans /12mm laminated ply board of approved shade and quality complete with all necessary beedings nails and fxtures requred all carriage complete .as directed or drawing provided by eng. Incharge .
23Providing & Fixing 30 mm thick wire guaze shutters using galvanised M.S wire guaze for aperture 1.4mm in both direction with wire of dia 0.63mm for doors, windows with hinges and necessary screws ( using imported wood K.D/silver ) as directed
24Providing & Fixing 4mm thick panels of Plain Glass incl. nails, 20mm beadings etc complete
25Providing & Fixing Aluminium ISI marked fittings to doors , windows, of required colour and shade with necessary screws etc complete
26T-bolts 100mmx12mm
27T-bolts 105mm x10mm
28Handles 125mm x10mm
29Handles 100mm x10mm
30Alldrops 125mm with lock system
31i-Hooks
32D.stoper
33Structural steel work in built up sections incl. cutting, hoisting, fixing in position i/c providing & applying priming coat of approved steel primer(using brands as directed by engineer incharge) including eaves boarding with 14 gauge sheet and soffits where ever requred complete as directed with frame complete with all carriage
34Providing & fixing corrugated colour coated High Rib 0.50mm thick approved brand as directed by engineer incharge with necessary nuts,bolts washers complete job using approved brand as directed by Engineer incharge with all carriage, wastages,overlaps complete
35Providing and fixing of .50mm thick colour coated plain sheets for ridge and velly incld. Necessary nuts and bolts with washels of approved quality as directed with all carriage
3612 mm thick cement plaster in 1: 6 cement mortar
37Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1 mm thick
38Painting with synthetic enamel paint of approved brand and manufacturerof required colour to give an even shade . Two or more coats on new work over an under coat of priming coat where required
39Making plinth protection 50mm thick of cement concrete 1:3:6 over 75 mm bed of dry brick ballast 40mm nom. Size well rammed consolidated and grouted with fine sand incl. finishing the top smooth cutting levling etc complete
40Wall Painting with acrylic emulsion paint of approved brand andmanufacture to give an even shade. Two or more coats on new work
41Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm)
42Providing and fixing 16mm thick Granite gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels
43Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete
44Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointingin white cement mixed with pigment of matching shade complete.
45Providing and fixing of Water supply and sanitry fittings incld drainage disposal system as follows with specification as per c.p.w.d specification (trench excavation ,wall cutting,conc cutting and making all good ) complete
4615mm dia pipe PPR quality as directed
4720mm dia pipe PPR quality as directed
4832mm dia ppr quality as directed
4975mm P.V.C pipes qlty as directed
50100mm p.v.c pipes qlty as directed
5150 mm p.v.c Pipes qulty as as directed
52PPR gate valve 15mm dia qlty as ditected
53PPR gate valve 20mm dia qlty as ditected
54PPR 15mm dia union qlty as ditected
55PPR 20mm dia union qlty as ditected
56PPR 15mm Tanky Nipple qlty as ditected
57PPR 20mm Tanky nipple qlty as ditected
5875mm pvc bend
5950mm pvc bend
60100mm pvc bend
61100mm door tee
62100mm 75mm reducer
6375mm cowel
64100mm Multi floor trap
65P trap 100mm
66Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests.
67Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps.
68Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
69Providing and fixing 15 mm nominal bore C.P. brass short nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.
70Providing and fixing 15 mm nominal bore C.P. brass long nose bib cock of approved qu
71Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931
72c.p nipple
73c.p waste
74pvc connection 45 cm long
75Providing and fixing P.V.C low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete: 10 liter capacity -White
76Providing and fixing 15 mm nominal bore of standard back type C.P. brass close hole basin mixer pillar tap of approved quality and make, weighing not less than 1.970 kg.
77Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with brackets of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
78Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour: 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
79Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distance of 37 mm from wall face with concealed fittings arrangements of approved quality and colour, weighing not less than 88 gms.
80c.p health foucet
81Construction of Man hole incld. Earth work excavation ,laying of solling, mud mate (1:4:8) B/W 9\\" thick wit plaster , cement concrete flooring with punning, making drainage eaisy, and heavy duty cast Irin man hole cover complete job with all carriage of material .
821'-6\\"x 1'-6\\" x 1'-6\\" inner side dimention
831'x1'x1' inner side dimentions
84Carriage of material by mechanical tgransport incld: load unloading et5c complete
85Stone agg for an avg: lead of 10 Kms
86sand agg for an avg: lead of 15 Kms
87Bricks for an avg lead of 10 kms
88Development of Approach path
89Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil :
90Providing and laying of stone soling (hand packed) including compacting in foundation trenches
91Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
92Chequerred precast cement concrete tiles 22mm thick in footpath and courtyard, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing, cleaning and curing complete, on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand) . Dark shade using ordinary cement.
93Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
94Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases for columns
95Carriage of material by mechanical tgransport incld: load unloading et5c complete
96Stone agg for an avg: lead of 10 Kms
97sand agg for an avg: lead of 15 Kms
98Supplying and filling of RBMs behind E/W including levelling , ramming spreading and consolidation etc incld cost and carriage etc
99Levelling Of Lawn
100Engagement of JCB for clerance of site and level the road surface removal of trees, plants including dressing of road @ 20 hours
101Supplying and filling of Good Soil including dressing , levelling , spreading and compaction incld carriage etc complete job
102providing and filling of 50 mm thick sand in layers including compaction by way of planting imported Grass / sherbs etc complete job
103parking
104Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil :
105Providing and laying of stone soling (hand packed) including compacting in foundation trenches
106Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
107Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
108Centering and shuttering including strutting, propping etc complete including removal of formwork
109Manufacturing supplying and fixing retro reflective sign boards made up of 2mm thick aluminum sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming type-IV of ASTM-D-4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC : 67-2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminum alloy rivets @ 20cm c/c to back support frame of M.S. angle iron of size 25x25x3mm along with theft resistant measures mounted and fixed with 2 nos. M.S. angles of size 35x35x5mm to a vertical post made upto M.S. Tee section ISMT 50x50x6mm welded with base plate of size 100x100x5mm at the bottom end and including making holes in pipes, angle flats, providing and fixing M.S. message plate of required size steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical M.S.-Tee support to be painted in black and white colours). Backside of aluminum sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coats including all leads and lifts etc. complete as per drawing, specification and direction of Engineer-in-charge. Cautionary/warning sign boards of equilateral triangular shape having each side of 900 mm support length of 3650mm
110Carriage of material by mechanical tgransport incld: load unloading et5c complete
111Stone agg for an avg: lead of 10 Kms
112sand agg for an avg: lead of 15 Kms
113Restoration of water supply to Trout Raceway
114Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil :
115P/Laying of Nallah stone soling, handpacked in bed incl. all carriages complete
116Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
117Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
118Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20mm nominal size stone aggregate.
119Centering and Shuttering incl. strutting, proping and removal of same.
120Supplying and filling of RBMs behind drain incld: spreading levelinling etc including cost and carriage etc
121Drain
122Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil :
123P/Laying of Nallah stone soling, handpacked in bed incl. all carriages complete
124Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
125Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
126Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20mm nominal size stone aggregate.
127Centering and Shuttering incl. strutting, proping and removal of same.
128Supplying and filling of RBMs behind drain incld: spreading watering ramming etc including cost and carriage etc
129Carriage of material by mechanical tgransport incld: load unloading et5c complete
130Stone agg for an avg: lead of 10 Kms
131sand agg for an avg: lead of 15 Kms
132P/L of RCC Spun Pipes of rquired dia to the recorded crsoos slope in proper position with proper cushion including trench excavation and refiling of excavated material as proper cushion incld: all carraiges involved wih loading and unloading all complete 24 \\" Dia
133Electrification
134Wiring for light point/fan point/exhaust fan point/call bell point with 2 x 1.5 sq.mm PVC insulated, FRLS copper conductor, 1100 V grade wires, conforming to IS 694, with conductors as per IS 8130 and insulation as per IS 5831, and having fire performance in accordance with IEC 60332, ISI marked with valid BIS license, complete with all accessories, Havell/Polycab/APAR/Fenolex/KEI/RR kabel/ Anchor or OEMs/ firms holding ISO 9001 certification (Quality Management System) and shall be supplied with routine test certificates, and any material not conforming to the specified standards shall be rejected, complete with all accessories as required; single core cable in surface / recessed medium class PVC conduit (Including cost of conduit), with modular switch (Legrand Mylinc/SSK NV/schneider Livia/Crabtree athena make.), modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group-A
135Wiring for light/ power plug with 2X4 sq. mm + 1X 4 sq. mm earth wire, FRLS PVC insulated copper conductor (Havell/Polycab/ Fenolex/Anchor/ equivalent as directed by engineer incharge.) single core cable in surface/recessed medium class PVC conduit (including cost of conduit)
136Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, modular plate, suitable GI box, connections etc. as required. Modular Switch & Socket:- (Legrand Mylinc/SSK NV/schneider Livia/Crabtree athena make.)
137Wiring for lighting circuits/inverter circuits/6-10 amp power plug with 2X2.5 sq. mm FRLS PVC insulated copper conductor (Havell/Polycab/APAR/ Fenolex/KEI/RR kabel/ Anchor make) as described in item no 1 as directed by engineer incharge.) single core cable in surface/recessed medium class PVC conduit, (including cost of conduit) alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
138Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
139Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor (Havell/Polycab/APAR/Fenolex/KEI/RR kabel/ Anchor make) as described in item no 1, single core cable in surface/ recessed medium class PVC conduit as required.
140(a) 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire
141(b) 2 X 10 sq. mm + 1 x 6 sq. mm earth wire (Heating Submain)
142(c) 2 X 1.5 sq. mm + 1 x 1.5 sq. mm earth wire
143(d) 2 X 4 sq. mm + 1 x 4 sq. mm earth wire
144S/F testing and comm. Of MCB's 10 kA of the below mentioned capacities in sub main controls legrand C curve, Schneider/Legrand/ABB/ Havells/ Siemens/L&T/Hager/BCH make OR OEMs/firms holding ISO 9001 certification (Quality Management System) as directed by engineer incharge.
145a) 6-32 Amp SP MCB
146b) 32 amp DP MCB
147c) 63amp DP MCB
148Supply and fixing modular blanking plates on existing modular switch plates, excluding cost of plates.
149Supplying and fixing following way, SPN, sheet steel, MCB distribution board, (legrand/ Shinider/Hager/ABB make) 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator): 16 way Double door
150Supply installation testing and commissioning of 12 W + LED Surface/recess, square or round Mounted light luminary fitting shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95, THD<10%, CCT 5700K, CRI 80. The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V. The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years, which includes replacement of fixtures of Philips/Havel's/Wipro make/sample to be approved before installation..
151Supply, installation, testing and commissioning of exhaust fan of 150 mm sweep suitable for wall/window mounting, complete with necessary frame, mounting arrangement, louvers/shutter, and all accessories as required; the fan shall be of robust construction with high-grade engineering plastic/metal body, aerodynamically designed blades, and heavy-duty copper motor suitable for continuous operation, conforming to relevant Indian Standards and safety requirements of Havell/Bajaj/Crompton/USHA/Orient OR OEMs/ firms holding ISO 9001 certification (Quality Management System) as directed by engineer incharge as per site requirement and necessary connections.
152Supply, installation, testing and commissioning of ceiling fan of 1 star, 1200 mm sweep suitable for 230 V, single-phase, 50 Hz AC supply, complete with all accessories such as down rod of standard/required length, canopy, shackle kit, blades, capacitor, regulator (electronic step type/modular type), and necessary hardware as required; the fan shall be of aerodynamic design with high-quality aluminium blades, dynamically balanced for vibration-free and low-noise operation, driven by a heavy-duty copper motor including iron hook complete. USHA Striker Galaxy/Havells Oyster matalic/Crompton Aura/OR OEMs/firms holding ISO 9001 certification (Quality Management System) and as directed by engineer incharge
153Supply, installation, testing and commissioning of ceiling fan of 1 star, 900 mm sweep suitable for 230 V, single-phase, 50 Hz AC supply, complete with all accessories such as down rod of standard/required length, canopy, shackle kit, blades, capacitor, regulator (electronic step type/modular type), and necessary hardware as required; the fan shall be of aerodynamic design with high-quality aluminium blades, dynamically balanced for vibration-free and low-noise operation, driven by a heavy-duty copper motor including iron hook complete. USHA Striker Galaxy/Havells Oyster matalic/Crompton Aura/OR OEMs/firms holding ISO 9001 certification (Quality Management System) and as directed by engineer incharge.
154Supply and fixing of 6 amp/250 V A.C fan dimmer step type 2 module with cover plate Anchor Roma plus/SSK NV/ equivalent make as directed by engineer incharge.
155Supply installation testing and comm. of flood light 100 W (warm, white), Epoxy powder coated die-cast aluminium housing (LM24) with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant. PG9 gland is used for cable entry and provision for loopin-loopout class 1, IP66, IK 07,, with high power LED's as light source with Built-In Potted IP67 electronic LED driver with APFC, lower THD, toughned glass and secondary lens, Open Circuit Protection, Over Voltage Protection, Surge Voltage Protection upto 10kV With Built In SPD & other safety test as per IS 15885 Part-2/Sec 13, IEC60598-1. Preferred make: Philips/Havell/Wipro/Crompton make. the job also includes the angle iron stand of suitable size to be grouted in cement concrete with hold fasteners complete job.
156S/Laying ( partly overhead/ partly underground) , testing and commissioning of XLPE aluminium armoured cable 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments.Havell/Eq. standard make as directed by engineer incharge and making end termination with brass compression gland and aluminium lugs of required size. 16 sq.mm 2 core ( Armoured)
157Supply, installation, testing and commissioning (SITC) of minimum 2.0 kVA, 230 V AC, 50 Hz, Pure Sine Wave Power Inverter with inbuilt automatic changeover, overload, short-circuit, over-voltage, low-voltage and reverse polarity protection, suitable for generator compatibility, complete with 02 Nos. 12 V, 200 Ah tall tubular lead-acid batteries of Exide/Microtek/Luminous or equivalent approved make, housed in a heavy-duty PVC battery trolley/stand. The item shall include all interconnections, battery terminals, input/output copper cables of suitable size and length, lugs, ferrules, insulation, earthing connections, fixing accessories, testing, commissioning, carriage, loading/unloading, and all taxes as applicable, complete in all respects.
158Supply of 1.5 Ton Capacity Wall mounted Split Air conditioners, Rated cooling capacity in Watts as per IS:1391 (Part 2) 3 star rating inverter type fitted with hermetically sealed Rotary type compressor (INVERTER rotary compressor (Variable Speed) ) operating on 230V ±10%, 50Hz single phase AC supply with evaporator and condensing unit made of copper tubes with aluminum fins, cordless remote control, copper piping for both suction and discharge of three(03) meters length with protection covering for piping rubber insulation, of suitable size of medium PVC pipe, power and control cabling as per site requirement, comprising of following etc. complete as per requirement. a) Insulated copper pipe lines liquid and suction lines as per manufacturer recommendation with OEM standard Eco-friendly Refrigerant Gas. b) Flexible copper cable between indoor & outdoor Unit of suitable size as per Manufacturer recommendation 3Cx2.5Sq.mm copper flexible Minimum 3 meters Length c) PVC Drain Pipe as per the OEM standard and Site conditions d) Suitable size of Rubber Insulation & protective covering of refrigerant line. DAIKIN/ MITSUBISHI/ CARRIER/HITACHI / IFB/BLUESTAR/VOLTAS/LG make . The job includes repairs to walls wherever the same are cut and the AMC of AC for a period of one year from date of successful commissioning. 1.5 ton with a Rated cooling capacity of 5000 ≤ 5200 (in Watts)
159Installation, Testing & commissioning of 1.5 Ton Capacity Wall mounted Split Air conditioners including all necessary accessories, fixing of indoor Unit, fixing of Outdoor Unit on Dully painted suitable size MS Stand including grouting/mounting of stand, Including first charging of refrigerant with laying of Insulated copper pipe lines liquid and suction lines and Installation of Drain pipe etc. complete for above item as per site requirement
160Supply of wall Mounting type 4 KVA capacity, Metal body, single phase, Automatic line Voltage stabilizers with copper wound coil having an input voltage 135 to 275V and a balanced/steady output voltage of 220 V +_ 3% , single phase, 50Hz AC with built in time delay, cut off and low voltage cut-off, i/p, o/p/trip indications, metal clad top etc., with connecting 3 core cable of 1 meter length complete etc. as per site requirement. EVEREST/ V GUARD/ PREMIER Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57107520
AUTHORITY Government Departments
TENDER VALUE 55.73 Lakhs
LAST DATE 02-09-2026
Authority
Authority Name Public Works Department
Work Description Tender for Augmentation/Restoration Of Trout Rearing Fish Farm Chawalgam Adv Cost Rs. 55.734 Lacs Incld: 18% Gst
Basic Detail
Tender No 57/2026-27/RnB/Kul/5576-86 Dtd 19-08-2026
Bidding Type Tender
Location
City Kulgam
State Jammu and Kashmir
Key Dates
Publish Date 20 Aug 2026
Submission Date 02 Sep 2026
Open Date 03 Sep 2026
Finance
Tender Value 55.73 Lakhs
Tender Fee 1600
EMD 1.11 Lakhs
Exemption Not Available
Document List
85c25663-2436-4fd4-807f-f7427bcf5636.html
BOQ_1074258.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Sep 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

85c25663-2436-4fd4-807f-f7427bcf5636.html

xls

BOQ_1074258.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders