Tender for Provn Of Approach Path For Swt At 27 End At Afs Yelahanka.
BOQ
| Sl. No. | Item Description |
| 1 | Excavation over area n.exc 1.5m deep and getting out in Hard/dense soil complete all as specified and as directed. |
| 2 | Excavation in trenches in hard/dense soil not exceeding 1.5 mtr width and not exc 1.5 mtr deep for laying of pipe in Hard/dense soil etc and getting out and surface dressing if required complete all as specified and as directed. |
| 3 | Returning and filling of trenches in two parts (i) using riddled soil obtained from excavated soil upto depth of 30cm (8cm below cable and remaining above cable) for cushioning of cable and (ii) refilling the trench of remaining depth with normal excavated soil all as specified and directed. Note: - Excavated soil shall be riddled by using sieve to separate composite particles etc as per IS 1255-1983 and refilling in trenches as in cable cushioning complete all as specified and as directed. (for laying of cable ) |
| 4 | Returning, filling including spreading levelling watering and well ramming in layers not exceeding 25 cm thick in hard soil complete all as specified and as directed. |
| 5 | Removing excavated material to a distance n exc.50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed. |
| 6 | Removing excavated material to a distance exc.1.50 Km but n exc 5 Km and depositing where directed complete all as specified and directed. |
| 7 | M&L for Hard core of gauge n exc 63mm in broken stone or boulders, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface etc complete all as specified and directed. |
| 8 | M&L for Rolling and consolidating formation surfaces in cutting with power roller exc 8 tonne but not exc 12 tonne complete all as specified and as directed. |
| 9 | M&L for 100mm thick Plain Cement concrete type D-2, 1:4:8 (using 40mm graded stone aggregates) as in sub-floors, sub bases, floors and pavings etc complete all as specified and directed. |
| 10 | M&L for Cement concrete work in pavement/hard standing of flexural strength 40 Kg/Sqcm in field using 400 Kg of cement per cubic meter thickness of concrete 25 cm complete all as specified and as directed. |
| 11 | M&L for Forming 12mm thick expansion joints in the thickness of concrete slab 250mm joint filled with preformed bituminous filler and top 30 mm primed and sealed with sealing compound , Grade 'A' complete all as specified and as directed. |
| 12 | M&L for Forming construction joint(Dummy) 65mm deep x 10mm wide and sealed with sealing compound Grade 'A' complete all as specified and as directed. |
| 13 | M&L for Finishing surface of concrete roads, pavements, by brooming complete all as specified and directed. |
| 14 | Supply, install, testing and commissioning of LT Panel board ,CPRI approved ,outdoor type, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars duly insulated by insulation of RYB colour 200 Amps rating mounted on porcelain insulators .The panels shall be factory made, double door, made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof front operated, front and rear opening with locking arrangement fixed with MS angle iron frame of size 50X50X5 mm duly embedded in PCC platform and duly powder coated with 7 tank process with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable all as directed at site and comprising of the following including dismantling of old LT Panel.INCOMER:(a) MCCB 100 Amp 4 Pole, 50 Hz, 415 V, 25KA -1 NoOUTGOING:(b) MCCB 63 Amp 4 Pole, 50 Hz, 415 V , 16 KA -1 Nos(c) MCB TPN 40A- 2Nos(d) MCB TPN 32A-1No(c) Three Phase Multifunction meter(V,I,PF) with suitable capacity of CTs-1No(d) Indicating Lamps (R-Y-B) Set LED Type with -one set(e) Fully automatic Star delta starter suitable 20HP -2NosNote: The Contractor Shall submit the drawing for approval of GE Before executing the work |
| 15 | M&L for Earthing complete with galvanised earth plate electrode of size 600x600x6mm thick burried directly in ground earth pit not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 mtrs below ground level connected to galvanised iron strip of size 32mm x 6mm as earth lead upto a length of 7.5 metre long by means of bolts, nuts, washers etc. and protected by GI pipe medium grade 40mm dia and 20mm dia GI tubing light grade with funnel for watering, all as shown in electrical plate No 3 of SSR Part-I, back-fill with salt and charcoal, provision of test point including connected to earth test point and necessary earth work excavation in any type of soil PCC (1:3:6) type C2 bed and chamber RCC (1:2:4) type B1, iron grill including PCC cover with hinge and funnel watering pipe etc all as specified and directed.Note :(a) Earthing value should be less than 5 ohms.(b) If desired value of earth resistance not achieved during testing, the earthing work shall be redone by the contractor at free of cost to achieve the desire value of earthing resistance. The rate quoted by the contractor deemed to be inclusive of the provision. |
| 16 | M&L for Disconnecting the existing incoming power cable from LT panel, carefully rerouting/looping the cable to suit the new panel position, and re-termination of the cable with suitable glands and lugs, including insulation checking, proper dressing and testing of the cable complete as required with suitable glands and lugs including ferruling, dressing, insulation testing and commissioning complete all as specified and directed. |
| 17 | Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 with peak, size 250 mm x 150mm x 40mm complete all as specified and directed. |
| 18 | Cutting of road/hard standing not exc 30cm in width and not exc 60cm in depth for laying of water tubing including returning filling and making good the disturbed surfaces using PCC 1:2:4 type B1 using 20mm graded stone aggregate on top 120 mm layer and fair finishing the surface without using any extra cement complete all as specified and directed. |
| 19 | Taking down existing LED light fitting along with the Cable of any size with bracket from PCC pole/MS pole complete all as specified and directed. |
| 20 | Refixing the retrived serviceable street light fitting of any watt along with the Cable and bracket complete all as specified and directed. |
| 21 | Dismantling and taking out MS pole/struts of any length, any size and complete all as specified and directed. |
| 22 | Supply and fix steel tubular swaged poles type 410 SP-22 (8.5 meter long) with cast iron base plate, finial taper plug, bolts, nuts and screws complete all as specified and directed. |
| 23 | M&L for Plain Cement Concrete1:4:8 type D2 using 40mm graded stone aggregate in foundation complete all as specified and directed. |
| 24 | M&L for Plain Cement Concrete 1:3:6 type C1 using 20mm graded stone aggregate for stay and couping for poles including necessary form work to exposed surface finished smooth and even complete all as specified and directed. |
| 25 | Supply, laying and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm 2 Core complete all as specified and directed. |
| 26 | Dismantling and taking out carefully XLPE LT UG Cable of 10 sqmm 2 core including earth work / RCC complete all as specified and directed. |
| 27 | Taking up/down 20mm steel tubing and disconnections of fitting, joints from tubing where required complete all as specified and directed. |
| 28 | Taking up/down 25mm steel tubing and disconnections of fitting, joints from tubing where required complete all as specified and directed. |
| 29 | Taking up/down 50mm steel tubing and disconnections of fitting, joints from tubing where required complete all as specified and directed. |
| 30 | Supply and laying of 25mm steel water tubing in trenches medium grade ISI marked incl all types of fittings such as bends, elbows, tees, short pieces, connectors, backnuts, diminishing pieces, caps, plugs and unions etc and accessories complete all as specified and directed. |
| 31 | Supply and laying of 50mm steel water tubing in trenches medium grade ISI marked incl all types of fittings such as bends, elbows, tees, short pieces, connectors, backnuts, diminishing pieces, caps, plugs and unions etc and accessories complete all as specified and directed. |
| 32 | Supply and laying of 20mm steel water in trenches light grade ISI marked incl all types of fittings such as bends, elbows, tees, short pieces, connectors, backnuts, diminishing pieces, caps, plugs and unions etc and accessories complete all as specified and directed. |
| 33 | Dismantling the existing unserviceable valve chamber in complete and Construction of valve chamber of Internal size 900mm x 900mm x 900mm deep with 200mm thick PCC block masonry walls built in CM 1:6 over 100 mm thick foundation concrete in PCC 1:4:8 type D2, (Using 40 mm graded coarse aggregate) with 100 mm off sets, 15mm thick complete internal plaster and external plaster up to a depth of 15 cm below GL in CM (1:6), 3 mm thick MS sheet cover, double door welded to 50 mm x 50 mm x 6mm MS angle frame fixed with hold fasts, 20mm x 6mm flat iron hinges with locking arrangement including lock sixty five mm, brass and keys (Make : Godrej / Shell), MS handles and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer to all steel surfaces including excavation & earth work in any type of soil /soft disintegrated rock and disposal of surplus soil to a distance not exceeding 50 Mtr complete all as specified and directed. |
| 34 | Supply and fixing in repairs 25mm Gun metal gate valve/globe valve of ISI marked with Iron wheel head screwed both end for GI tubing complete all as specified and directed. |
| 35 | Supply and fixing in repairs 50mm Gun metal gate valve/globe valve of ISI marked with Iron wheel head screwed both end for GI tubing complete all as specified and directed. |
| 36 | S&F in repairs flat cable PVC insulated and sheathed multi-stranded copper conductor water proof suitable for submersible pump set of size 6 Sqmm 3 core complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 20, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedSep 17, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender