Tender For Repairs To Manglore Pattern Tiles, Galvalium Sheet, Roof Over Roof, Puf Sheet Roof And Reinforced Cement Concrete Roof In Zone C Under Age B/R-1 At installation Shivaji Lonavla (8485/E8)
Tender Value
48 Lakhs
Estimated cost
Bid Submission
12 Sep 2026
20 days left
EMD
96000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repairs To Manglore Pattern Tiles, Galvalium Sheet, Roof Over Roof, Puf Sheet Roof And Reinforced Cement Concrete Roof In Zone C Under Age B/R-1 At installation Shivaji Lonavla (8485/E8)
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling mangalore pattern roofing tiles single layer including ridge tiles laid, bedded in cm complete all as specified and as directed. |
| 2 | M&L for mangalore pattern roof tiles inter locking at side and joints laid dry complete all as specified and as directed. |
| 3 | .-Ditto- all as per item No-2 here-in-before but except tile complete all as specified and directed. |
| 4 | Dismantling timber Scantling in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section complete all as specified and as directed. |
| 5 | Dismantling timber Scantling 40 sqcm and over in section, in any position complete all as specified and as directed. |
| 6 | S&F Tubular sections of in rafters fixed with self tapping screw of size not less than 75mm and 25X25 mm thick for battens fixed on rafters over CGI sheet roof with necessary fittings and welding for supporting mangalore pattern roof tiles complete (Fe 410-W, Grade-E-250 quality A) |
| 7 | Dismantling of CGI/PGI sheet roofing any gauge and any thickness including ridge, valley gutter etc complete all as specified and as directed. |
| 8 | S&F CGI sheeting 0.63 mm thick with two corrugation side lap fixed with L or J type bolts in roof walls etc with grade of zinc coating 275 gm/sqm complete all as specified and as directed. |
| 9 | .-Ditto- all as per item No-09 here-in-before but except sheets complete all as specified and directed. |
| 10 | S&F 0.63 mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with L or J type bolt, grade of zinc coating 275 gm/sqm complete all as specified and as directed. |
| 11 | .-Ditto- all as per item No-11 here-in-before but except sheets complete all as specified and directed. |
| 12 | Demolition of brick work or stone boulder masonry,built in cement mortar or cement lime mortar including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stone work and precast concrete articles etc complete all as specified and directed.. |
| 13 | M&L for Ridge or hip tiles to suit Mangalore pattern roofing tiles, bedded and jointed in cement mortar 1:6 complete all as specified and as directed. |
| 14 | .-Ditto- all as per item No-14 here-in-before but except Ridge or hip tile complete all as specified and directed. |
| 15 | M&L for Filleting in any position and to any shape in cement mortar 1:6 sectional area exc 25 but n. exc 50 Sqcm complete all as specified and as directed. |
| 16 | Dismantling wall and ceiling boards(fibre,pulp, unsulation etc) or unsulation board/slab/beam kob, any thickness including cover gillet complete all as specified and directed |
| 17 | S&F Arm Gyp-FB ceiling snow Frost vinyl face, washable metallized polyester foil backing ,vinyl covered edges, suspended ceiling on suspension system. Panels shall be of Size 600 mm x 600 mm x 9 mm, having 7 kg/SQM, including providing Grid system for fixing ceiling tiles shall comprise of suspension system with true horizontal level, suspended on inter locking tegular “Select” system with 15mm black flanges incorporating a 4mm central reveal in black colour and a load carrying capacity of minimum 14.50 kg/m2 with birdsmouth notches metal grid of hot dipped galvanized steel sections consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 15x32 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 15mmx25mm made of 0.30 mm thick (minimum) sheet, 1200mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200mmx600 mm and secondary cross \\"T\\" of length 600 mm and size 15mmx25mm made of 0.30 m thick (minimum) sheet to be interlocked at middle of the 1200mmx600 mm panel to form grids of 600mmx600mm and wall angle of size 20mmx15mmx0.3 mm and laying false ceiling tiles of approved texture in the grid including, required fitting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85mm x 30mm x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 15 mm of all T-sections all complete for all heights as per specifications, drawings incl dismantling of old ceiling, all as specified and directed. |
| 18 | Surface Preparation: Remove Existing water proffing treatment which includes membrane,plaster & Padding concrete and removing the waste material / debris to a distance exc. 1500m n.exc. 2000m etc & All loose and de-bonded concrete/ screed, loose particles, dirt & should be removed. Roof substrates must be pressure-washed with water with a minimum working pressure of 1,400 psi to be used to and/or remove all dirt, dust, chalking and waste products. complete all as specified and directed by engr.-in-charge. |
| 19 | Screed Repair: concrete padding should be done with concrete mix ratio 1:2:4 not less than 40mm and top surface should be prepared with plaster of 1:3 ratio along with water proofing material complete all as specified and directed by Engg-in-Charge. |
| 20 | Waterproofing Application: Premix Dr. Fixit Wonderproof 100 Components A and B using an electric double-paddle mixer for 2–3 minutes at low speed. Apply the first coat of Dr. Fixit Wonderproof 100 at a rate of 0.80–0.90 kg/m² without dilution, using a lamb’s wool or cloth roller. While the coating is still wet, roll and embed a 225 gsm Fiberglass Chopped Strand Mat, ensuring full bonding without air bubbles or wrinkles. Allow the first coat to dry for 3–4 hours. Apply the second coat at a 90° angle to the first. Overlap the chopped strand mat by at least 5 cm at the joints, ensuring the overlaps are sufficiently wet to achieve proper bonding. Once the surface is dry enough to walk on, apply the second coat at 0.70–0.80 kg/m². Apply additional coats as needed to achieve a total dry film thickness of 900–1000 microns, with a total system material consumption of 1.50 - 1.60 kg/m² over 2–3 coats. Note – Coating should be terminated below the drip mould on the vertical surface. The material has followed technical properties: Attains a Tensile Strength ≥ 18 N/mm2 as per ASTM D 2370; Crack bridging ability, Tear Strength ≥ 160 N/mm as per ASTM D 624, Dynamic Crack bridging as per EN 13251:2016 - No Cracks after 20000 sinusoidal cycles, Dynamic Crack bridging as per ASTM C 1305-2016 - Pass, No Crack, Pass Low Temperature Flexibility (-20 after 1000 Hrs. UV as per ASTM D 1970-2021, Shore A as per ASTM D2240 – 85 , Peel Adhesion to Concrete under wet Condition -24 Hrs. – N As per ASTM C 794 – 11.4 , Abrasion resistance (CS 17 Wheel -1000 Cycle, 1.0 Kg) as per ASTM D 4060 - 7 mg , Depth of Water Permeability @ 10 Bar as per EN 12390-8-2019 – Nil , Water Migratlon Resistance as per ASTM D 7281,-2007 - No Leakage, Pass Spread of flame Class A. Complies with the requirements of EN 13251:2016 for a 25-year service life when used with a 225 gsm Fiberglass Chopped Strand Mat as fleece. The system comes with 10 Years’ waterproofing warranty from M/S Pidilite Industries LTD. For vertical surfaces and parapet walls should be enveloped & coated / painted with Dr. Fixit Raincoat Classic or Dr. Fixit Raincoat Select Waterproof coating system. |
| 21 | Disconnecting existing tanks of any capacity(in ltrs) , setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position after carrying out Roof treatment with all accessories all as specified and directed |
| 22 | Demolition of Reinforced cement Concrete water tanks of any size and any height over roof slab and making roof surface good including removing debrisposition not otherwise specifically provided for |
| 23 | Removing building materials etc. (other than spoil payable under items 03028 to 03031 in Section-3—Earthwork) to a distance of 100m but n exc. 5 km beyond the lead included in the rates, including loading, unloading and stacking at the destination |
| 24 | Complete removal of existing treatment and applying Water proofing treatment of External walls by applying two coats of elastomeric coating material after cleaning the surface thoroughly and sealing all cracks with acrylic sealing compound as per the manufacturer's specifications and applying two coats of anti fungal exterior paint as directoris of Engg-in-charge.Make Pidilite, Buildcore chemicals or equivalent NOTE: The Treatment should be carried out through Authorised applicator only |
| 25 | S&F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall/Shed, fixed with self tapping screws all as specified and as directed. |
| 26 | S&F Pre painted galvalume aluminium zinc coating GI based plain sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified. |
| 27 | Dismantling wrought iron or mild steel work of any description not otherwise provided for as specified and as directed. |
| 28 | S&F Framed work as in doors Window Grill, Grating, ladder ,Hand rail, or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete.Fe 410 W(Gde)-E-250 Quality-A Complete all as Specified and directed by Engineer-in-charge |
| 29 | M&L for preparation of new/old steel surfaces of any descriplain, over 10cm width or girth and applying two coat of anticorrosive epoxy paint over a coat of epoxy primer all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 20, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 12, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysSep 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender