Tender For Repairs / Replacement Of Ht Cables, Jointing Kits, Ht Switch Gear System, Control Panels, 02/04 Pole Structure And Connected External Electrification Network System At Army Area Under Ge Avadi

Issued by Statutory Bodies & Commissions/Committees · Thiruvallur, Tamil Nadu
Tender Value
56 Lakhs
Estimated cost
Bid Submission
16 Sep 2026
26 days left
EMD
1.09 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Thiruvallur → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repairs / Replacement Of Ht Cables, Jointing Kits, Ht Switch Gear System, Control Panels, 02/04 Pole Structure And Connected External Electrification Network System At Army Area Under Ge Avadi

BOQ

Name of Work:- REPAIRS / REPLACEMENT OF HT CABLES, JOINTING KITS, HT SWITCH GEAR SYSTEM, CONTROL PANELS, 02/04 POLE STRUCTURE AND CONNECTED EXTERNAL ELECTRIFICATION NETWORK SYSTEM AT ARMY AREA UNDER GE AVADI
Sl. No. Item Description
1Item Rate BoQ BoQ_Ver4.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: COMMANDER WORKS ENGINEER,CHENNAI Name of Work: REPAIRS / REPLACEMENT OF HT CABLES, JOINTING KITS, HT SWITCH GEAR SYSTEM, CONTROL PANELS, 02/04 POLE STRUCTURE AND CONNECTED EXTERNAL ELECTRIFICATION NETWORK SYSTEM AT ARMY AREA UNDER GE AVADI Contract No: CWE/AVD/ OF 2026-2027 Name of the Bidder/ Bidding Firm / Company : SCHEDULE 'A'(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of items Item Code / Make Quantity Unit Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT With Taxes TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words
2Earthwork excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out in soft / loose soil for laying cables / pipes / erection of poles etc. complete all as specified and as directed. Note:- Excavation shall be carried out manually at site where directed by the Engineer-in-Charge to avoid breakage of existing Electrical water connections. Rate quoted by the contractor shall deemed to be include for the manual excavation.
3All as per item No 01 above but depth exceeding 1..5 m but not exceeding 3.0m
4Removing excavated material (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
5Returning filling in soil including spreading levelling watering well ramming in layers not exceeding 25 cm each all as directed.
6Supply and laying reinforced precast concrete cable cover, class HV, type 1, Flat, of size 300 mm x 180 mm x 40 mm thick , laid flat in trenches over the cable with length of cover perpendicular to the direction of cable adjacent/abutting each other complete all as specified and as directed.
7Laying only old precast concrete cable cover slab of any description and size laid flat in trenches over the cable with length of cover perpendicular to the direction of cable adjacent/abutting each other complete all as specified and as directed.NOTE: Serviceable cable cover slab obtained during excavation shall be cleaned and relaid
8Supply and laying HT UG Cable XLPE insulated with multistranded aluminium conductor armoured with galvanised steel wire / taps 11000 volts grade conforming to IS in trenches/poles/wall etc of following sizes including taking down the existing unserviceable cable complete all as specified and as directed :-
9HT UG Cable of size 3 core x 95 sqmm .
10HT UG Cable of size 3 core x 120 sqmm .
11HT UG Cable of size 3 core x 185 sqmm .
12HT UG Cable of size 3 core x 240 sqmm .
13M&L for finding of fault from HT cables by using of high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position/location of fault, disconnecting faulty 11 KV HT cable and taking out from trenches/Poles/HT equipments of different sizes from both ends, removal of fault, Re-connections including testing of cables after removal of fault complete all as specified and directed by Engineer-in-Charge.Note: (a) Cable & joints shall be measured and paid separately under respective items (b) Quoted rate shall be inclusive of hiring charges for HT fault Locater equipments. (c) Rate quoted inclusive of all material and labour required for emergency maintenance work of HT/LT cable line during breakdown by deploying skilled persons at faulty site including transportation and other tools and plant required at site for fault rectification.(d) Contractor or his representative shall come to the site and attend and rectify the breakdown / complaints within two hours of receipt of the incident/complaint of notification of breakdown.If fails to rectify the complaints within two hours, a penalty of Rs 500 per fault per hour shall be imposed and shall be deduct from the due payment against the contractor .
14S&F in repairs indoor termination cold shrink type joint for 11 KV(Earthed) grade underground cable including jointing materials and accessories including labour complete for making joint suitable for HT, UG, 3 core, XLPE / armoured heavy duty cable with aluminium conductor of following sizes complete all as specified and as directed :-
15HT UG Cable of size 3 core x 95 sqmm .
16HT UG Cable of size 3 core x 120 sqmm .
17HT UG Cable of size 3 core x 185 sqmm .
18HT UG Cable of size 3 core x 240 sqmm .
19S&F in repairs outdoor termination heat shrink type joint for 11 KV(Earthed) grade underground cable including jointing materials and accessories including labour complete for making joint suitable for HT, UG, 3 core, XLPE / armoured heavy duty cable with aluminum conductor of following sizes complete all as specified and as directed :-
20HT UG Cable of size 3 core x 95 sqmm .
21HT UG Cable of size 3 core x 120 sqmm .
22HT UG Cable of size 3 core x 185 sqmm .
23HT UG Cable of size 3 core x 240 sqmm .
24Supply and fixing in repairs Straight through heat shrink type joint for 11 KV(Earthed) grade underground cable including jointing materials and accessories including labor complete for making joint suitable for HT, UG, 3 core, XLPE / armoured heavy duty cable with aluminium conductor of following sizes complete all as specified and as directed :-
25HT UG Cable of size 3 core x 95 sqmm .
26HT UG Cable of size 3 core x 120 sqmm .
27HT UG Cable of size 3 core x 185 sqmm .
28HT UG Cable of size 3 core x 240 sqmm .
29M&L for disconnection and removing the unserviceable Aluminium conductor / jumper wires from the HT 2/4/6 Pole structure and provision of new Aluminium overhead conductor jumpers surrounded by PVC insulation sleeves with R,Y& B color code complete all as specified and directed.Note :(a) All the jumper wires should be replaced with new jumper wires(b) Type of conductor used for jumper should be RABBIT.(c) Quoted rate shall deemed to be inclusive for all the misc work such as Nut, bolts, washers, welding etc. for satisfactory completion of job .(d) Minimum clearance should be maintained among the conductors as per the Electricity Regulations.(e) Zero percent sag should be maintained for each jumper wire to avoid short circuits.
30Supply and install polymer Switch Air Break gang operated triple pole, mechanically operated mounted on polymer insulator and steel frame with operating mechanism worked from ground level complete with 9 number polymer insulators of rating up to 200 Amp, 11000 volts including necessary length of down pipe made up of galvanized iron medium grade 20mm bore with operation handle and locking arrangements including taking down the old unserviceable one complete all as specified and as directed .
31S&F in repairs polymer Lightening arrester expulsion type complete with all fitting transmission class ,discharge capacity 200-800 Amp 11000 Volts rating complete all as specified and as directed.
32Supply and lay galvanized iron tubing of 80 mm dia ,light grade in trenches / fixed on poles complete including all necessary fittings including taking down the old unserviceable one complete all as specified and as directed .
33S&F in repairs pin type insulator ,polymer, including one galvanized mild steel spindle ,two galvanized iron washers and one galvanized iron nut for 11000 volts grade complete all as specified and directed.
34S&F in repairs Disc type polymer insulators, creepage distance 120 mm, T&C and B&S end fitting type suitable for high tension over head conductors working pressure 11000 volts grade complete all as specified and as directed .
35S&F in repairs loop type porcelain insulator vitreous white, brown, or green with over all dimension 90 x 140 mm clearance of hole 25.5 mm complete all as specified and as directed .
36S&F ACSR conductor of any size for HT over head line including jumpers on PCC/RCC/Steel pole and binding wires for line connecting up etc of any size including taking down the old unserviceable ACSR conductor complete all as specified and as directed .
37S&F Anti climbing device, spikes type, fabricated out of MS bars round square and flat including nuts, bolts, washers and welding into two halves made to shape to suit to the cross section of the pole of any size including taking down the old unserviceable Anti climbing device complete all as specified and as directed.
38S&F Mild steel cross arms ,bracing supports clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding ,bending, cold or hot drilling holes for insert bolts in any shape or size as indicated and as directed including applying one coat of red oxide primer and one finishing coat of aluminum paint and taking down old unserviceable cross arms etc complete all as specified and as directed.
39S&F in repairs danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled white with letters, figures and conventional skull and bones in signal red color and fixed with MS clamps, bolts and nuts suitable for HT of approved of size 25x20 cm complete all as specified and as directed.
40Supply and lay synthetic rubber insulated mat of 2 mm thick for voltage 11 KV for electrical purpose as per IS 15652-2006 suitable for electrical shock safety of size 2.0 m x1.0 m including taking down old unserviceable mat complete all as specified and as directed.
41Supply and lay synthetic rubber insulated mat of 2.50 mm thick for voltage 11 KV for electrical purpose as per IS 15652-2006 suitable for electrical shock safety of size 2.0 m x1.0 m including taking down old unserviceable mat complete all as specified and as directed.
42Supply and spreading hard core with broken stone of gauge not exceeding 63mm, deposited, spread and leveled in layers not exceeding 15cm thick watered and rammed to a true surfaces complete all as specified and as directed.
43S&F in repairs Horn Gap type Fuse unit, 11000 volts grade, mounted on polymer insulators and steel frame, single pole, fixed on DP structures complete all as specified and as directed.
44S&F in repairs Expulsion type drop out fuse element 10 Amps and up to 100 Amps suitable for 11KV Horn Gap type fuse unit complete all as specified and as directed.
45M&L for overhauling and calibration by using suitable testing kits of under mentioned capacities HT equipments (i.e. VCB, RMUs, Compact Sub Stn Units) by drawing out the draw-out module of the breaker, carrying out complete cleaning with clean cloth & cleaning agent, lubrication of the mechanism & greasing with high temperature molly grease, testing for smoother ON/OFF operation, carrying out relay calibration of protection relay by secondary current injection methods to check trip time characteristic of relays, checking of healthiness of CTs & points ,checking of IR value of interrupters, healthiness of protection tripping of circuit breaker etc. choking and servicing switchgear interlocks and safety like Mechanical - 1. Positive Interlock, 2.Negative Interlock, 3. Spring Discharge Interlock, 4. Padlocks, 5. Key Interlocking 6. Safety Roll in Stop, 7. Safety Roll - out Stop,8. Rating Interference Interlock. Electrical - Interlock Switches), checking of electrical operations of the breaker for ON/OFF & Trip operation for Incomer and Outgoing including submission of service & test reports. Make: Crompton Greaves/ABB or any other equivalent make/model approved by Accepting Officer . Note: (a) The servicing should be carried out through Authorized service provider of original Manufacturer. (b) Any minor items which are not covered in above description but required for successful operation of the panel shall be provided by the contractor and quoted rate shall be inclusive for the same and nothing extra shall be paid .
46Supply and replacement of following items of 400 Amps to 800 Amp capacity, 11 KV, 3 phase, 50 Hz, HT VCB/RMU/CSS of any quantity during servicing of HT equipments as stated in above item including taking down old unserviceable items complete all as specified and as directed.
47Charging Gear
48Rack in and out Gear
49Rack in and out mechanism complete. Make: ABB or other euivalent as per site requirement
50Charging Rod
51Rocker Lever
52Charging Bush
53Spring charging mechanism
54630A Vacuum Interrupter
55Tripping Relay
56Tripping coil
57Over current earth fault relay, Phase and earth current input 1/5A,ICE version.
58Breaker control switch
59Manual spring charging handle
60S&F in repairs push buttons (Closing/Tripping) of any type / model / capacity in HT equipments / panels complete all as specified and as directed.
61S&F in repairs indicating lamp of any type / model / capacity in HT VCB/SFU panels complete all as specified and as directed. Make: Siemens or other equivalent as per site requirement
62S&F in repairs multifunction meter with RS port of any type / model / capacity in HT equipments /panels complete all as specified and as directed.
63S&F in repairs TNC switch of any type / model / capacity in HT equipments / panels complete all as specified and as directed.
64S&F in repairs heating element 250 Watts with thermostat including necessary wiring of any type / model / capacity in HT equipments / panels complete all as specified and as directed.
65S&F in repairs power pack unit suitable for 220 volts AC input & 24 volts DC, 4 Amps output complete suitable for operation of HT Panel all as specified and directed.
66S&F in repairs of insulators of any size / model suitable for HT eqpts/panels complete all as specified.
67S&F in repairs of cable boots suitable for HT cables of any size and model complete all as specified and as directed.
68S&F in repairs of Tulip contact assembly for suitable finger type complete all as specified and as directed.
69S&F in repairs of 64 Pin plug for unigear system with control wiring complete all as specified and as directed.
70M&L for rectifying fault after inspecting HT equipments / panels of any type / model complete all as specified and as directed by engineer-in-Charge. Note: (a) The fault finding should be carried out through Authorized service provider of original Manufacturer. (b) Spares shall be measured and paid separately under relevant items. (c) Any minor items which are required for operation and smooth functioning of equipments shall be provided by the contractor and quoted rate shall be inclusive for the same (d) Contractor should attend and rectify the breakdown / complaints within two hours of receipt of the complaint, if not a penalty of Rs 500 per fault per hour shall be imposed and shall be deduct from the due payment against the contractor
71M&L in repairs for RMU mechanical locking system complete all as specified and directed.
72M&L for replacement of existing Current Transformer (CT) of 11 KV rating with new indoor epoxy cast,11 KV,50Hz,100-0/5A suitable for operation in existing HT panel as per site condition complete all as specified and as directed.
73M&L for carrying out complete servicing of AB Switch by lubricating the mechanical parts including greasing with petroleum jelly complete all as specified and as directed. Note: Minimum spares /lubricants and tools required for the job shall be deemed to be included in the quoted rates.
74Labour only for stringing of ACSR conductor from pole to pole upto 3 conductors by maintaining sag as per HT specification complete all as specified and as directed by Engineer-in-Charge. Note :- (a). One unit RM of stringing consists of tightning of 3 conductor of 1 RM length. Note: (b). Minimum spares and tools required for the job shall be provided be be deemed to be included in the quoted rates.
75S&F in repairs HT 11 KV Phase/Line Separator for fixing OH ACSR conductor 11 KV range complete all as specified and as directed.
76M&L for preparation of old painted surface by removing dust and other deposited materials by scraping from HT tubular pole of 11 metre long, painting of pole with one coat of black paint up to 1.0 m from bottom and painting the rest of the pole including cross arms cable protection pipe,clamps , with one coat of aluminium paint complete all as specified and as directed.
77M&L for servicing of four pole structure including checking / tightening / making free for operating of AB switches, insulators, lightning arresters, changing of nut / bolts if required including painting of RYB paint / tape at strip including preparation of old painted surfaces ,removing dust and other deposited materials by scraping from HT tubular pole of 11 metre long, painting of pole with one coat of black paint upto 1.0m from bottom and painting the rest of the pole including cross arms cable protection pipe clamps, bracket with one coat of aluminum paints complete all as specified and as directed .
78M&L for servicing of two pole structure including checking / tightening / making free for operating of AB Switches, insulators, lightning arresters, changing of nut/bolts if required including painting of RYB paint/tape at strip including preparation of old painted surfaces ,removing dust and other deposited materials by scraping from HT tubular pole of 11.0 metre long, painting of pole with one coat of black paint upto 1.0 m from bottom and painting the rest of the pole including cross arms cable protection pipe clamps, bracket with one coat of aluminium paints complete all as specified and as directed.
79M&L for disconnecting the transformer of capacity up to 200KVA from the electrical system, taking out and shifting the same for repairing to work shop, drain out old transformer oil, opening the top cover of the transformer with conservator and taking out core with limbs and primary & secondary windings after disconnecting and removing iron core, removing damaged primary & secondary windings etc as per requirement and rewinding, re insulating and removal of moisture on oven heating & re-assembling transformer winding and core heating including insulating and packing material in order to take out all moisture from the transformer assembly complete, lowering the core assembly with winding in transformer body, connection work and re-assembling in position top cover, conservator, breather with relay control wiring complete including transportation of transformer back from workshop to site, installation of transformer on foundation, commissioning and testing complete all as specified and directed.Note:- (a) Necessary T&P items as required for shifting of transformer from site to workshop and back shall deemed to be included in the quoted rate.(b) Copper winding wire for rewinding shall be measured in Kg and paid separately under relevant of items .(c) Draining of transformer oil, filtering & dehydrating of oil and filling back if found usable in to the transformer shell and gasket and miscellaneous items as required for smooth functioning shall deemed to be inclusive in the quoted rate
80All as per item No 49 here-in-above but of capacity exceeding 200 KVA to 500 KVA complete all as specified and as directed
81M&L for copper winding, paper insulated wire complete as per existing gauge for existing number of turns for LV/HV coil/leg rewinding of transformer of any capacity complete all as specified and as directed
82M&L for disconnection and removing the unserviceable/ burnt out Primary 11 KV bushing units from transformer of any capacity/model complete and replace the same with same size and capacity of bushing with brass Studs along with suitable nut bolt and washers complete all as specified and directed.
83M&L for disconnection and removing the unserviceable/ burnt out Secondary LT bushing units from transformer of any capacity/model complete and replace the same with same size and capacity of bushing with brass Studs along with suitable nut bolt and washers complete all as specified and directed.
84M&L for replacement of fiber gasket sheet 3 mm thick to prevent leakage from transformer 11/0.433 KV ratio, up to 500 KVA capacity complete
85M&L for replacement of porcelain insulator with suitable rubber 'O' ring for HT side bushing of transformer up to 630 KVA complete
86All as per above item No 55 here in before but for LT side bushing
87Supply and filling Silica Gel from transformer breather of any type / model / capacity including taking down old unserviceable complete all as specified and as directed.
88S&F Breather assembly of size 50 mm dia,minimum 250mm long suitable for transformer of any type / model / capacity including taking down old unserviceable complete all as specified and as directed.
89S&F oil temperature indicator dial type having temperature range 0 to 120 degree Celsius suitable for transformer of any type / model / capacity including taking down old unserviceable complete all as specified and as directed.
90M&L for disconnecting the transformer/VCB/RMU connections HT/LT of any capacity/model, pole/plinth mounted shifting the same in AOR of GE Avadi and connect to the exist HT/LT cables properly complete all as specified and directed by Engr-in-charge. Note:- (a). Necessary T&P items as required for shifting of transformer shall deemed to be included in the quoted rate. (b) During shifting if any damage accured to the transformer/VCB/RMU ,the same shall be repaired by the contractor without any extra cost
91M&L for painting outer surfaces of transformers of capacity 63 to 500 KVA, any type / make / model, pole or plinth mounted, installed at various sub stations with one coat of synthetic enamel paint of approved color, after cleaning all surfaces including writing SM / MES numbers, capacity, make, date of oil testing etc.,in paint complete all as specified and as directed.
92M&L for ON load centrifuging and dehydration including filtration, heating, re-circulation and cleaning of transformer oil by dehydration machine for 11/0.433 KV transformers Indoor/Outdoor type up to 500 KVA capacity installed at different sub stations/locations (i.e. AOR of GE Avadi) for improving di-electric strength of the oil to with stand 40 KV for one minute including testing of oil complete all as specified and as directed. Note :- (a) Deficient quantity of Transformer oil required for topup shall be measured and paid separately under relevant items. (b) Centrifuging Machine with all T&P & testing machine of oil required for dehydration shall be arranged by the contractor. (c)Transformer oil test kit shall be provided by the contractor at site for testing of oil.
93Supply and filling / topping up new transformer oil conforming to IS Specification for transformers installed at various sub stations complete all as specified. (Make:-HP/Castrol/Power oil)
94M&L for cutting/clearing and removing the vegetation/bush/creepers growth any nature/type around/on the electric poles/stays/two and four pole structures/installations / substation, so as to keep clean the area for easy access to carry out repair/maintenance works on poles etc, removing from site and throwing out at a place where directed at distance not exceeding 250 m away complete all as specified and as directed by Engineer-in-Charge.
95M&L for pruning of tree branches and making clear HT line to the minimum distance of 30 m span for 3/6 conductors and removing from site and throwing out at a place where directed at distance not exceeding 250mtr away complete all as specified and as directed.
96M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x6 mm thick burried directly in ground (earth plate not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level, connecting to the Galvanized iron earth strip 25x4mm by means of bolts, nuts, check nuts and washers of galvanized iron and earth wire protected by provision of GI medium grade pipe 40 mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25x25x6mm and handle of 6mm dia MS bar made to shape, GI light grade 20mm bore pipe for watering of suitable length placed on top edge of earth plate, charcoal and common salt filling, with fixing arrangement, funnel, wire mesh and earth work in soft/loose soil, returning filling in and removal of surplus soil to a distance not exceeding 50 meters, complete all as directed and connecting to existing earth test point all as specified or indicated including testing on completion.
97All as per above item 66 here in before but using copper earth plate of size 60cm×60cm ×3 mm thick electrode and 20×3mm thick copper earth strip complete all as specified and directed.
98M&L for Earth continuity conductor or main earthing lead of GI strip of size 25x4mm , fixed to wall or burried in ground or drawn in conduit/pipe or any other indicated situation for loop earthing etc. as required complete all as specified and as directed. Note :- Eathing continuity conductor beyond 7.5m for Earthing shall be measured under this item.
99All as per above item No 68 here in before but for copper strip of size 20x3mm thick
100M&L for disconnection and removing the unserviceable steel tubular poles ,supply and erect Steel tubular swaged poles 11.00 meters long ISI marked complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55 complete all specified and as directed.Note:- Excavation, PCC foundation , returning filling, pole painting and numbering shall be measured and paid separately under relevant item
101M&L for plain cement concrete 1:3:6 type C2 using 40 mm graded stone aggregate as in foundations, filling and mass concrete complete all specified and directed.
102M&L for plain cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in coping, filling and mass concrete including necessary form work as required complete all specified and directed.
103M&L for Sand cushioning to underground cables by filling river sand upto top of the cable in 11 KV Sub stations complete all as specified. Note :- Thickness shall be measured after punning
104Hiring of transformer of capacity 200KVA as and when the existing transformer shifted to work shop for repairing /maintenance works complete all as specified and directed by Engineer-in-charge.Note:- (a) Hiring of transformer for 24 Hours shall be measured as one job (b) Necessary T&P and transport etc as required for shifting of transformer from site to workshop and back and necessary connection etc shall deemed to be included in quoted rate.
105Taking out HT XLPE UG Cable / PVC Sheathed aluminium conductor 95 to 185 sqmm x3 core armoured from trenches/poles/wall etc and relaying/rerouting in trenches/Poles/Wall etc after attending fault / rectification and duly tested after relaying complete all as specified and directed. Note: Necessary Earth Work and connected items, jointing kit etc shall be measured and paid separately under relevant Item
106M&L for dismantling of old broken platform and construction of platform for mounting of transformer using brick masonary with sub class 'B' old size bricks ,plateform of size is 3000mmx2500mmx1800mm including foundation depth of 500mm below ground level including provision of chain link fencing all around the transformer plateform ,1.5 m high above the platform , top made out of 4mm thick mild steel plain wire supported with angle iron of 50mm x50mm x 6mm including provision of one opening gate of size 1 m wide and 1.5m in height with locking arrangement fixed to fencing with angle iron including applying two coats of cement base paint over a coat of primer on plateform walls and applying two coats of synthetic paint over a coat of red oxide paint on all steel surfaces of fencing including fencing wire , fixing of two Nos of MS channel of size MC 80 at the centre of plateform, top for moving of transformer wheels, including of 4 x danger notice board for HT 11000 volt fixed to each side of transformer fencing all as specidfied and directed by Engineer-in-Charge.Note: - Earth work excavation and PCC foundation etc shall be deemed to be included in the unit rate quoted
107M&L for shifting of transformer of any capacity from existing unserviceable platform to new platform incluidng disconnecting and reconnecting all connection of transformer and other switchgear and connection or earth strips etc complete all as specified and all as directed by Engineer in charge.Note:- T&P and other accessories as required for lifting and shifting of Transformer shall be included in the quoted rate.
108Excavation in post holes (or similar holes) each not exc 0.5 cum, getting out, in soft/loose soil including returning, filling in and ramming earth or broken rubble mixed with earth around in layers n.exc 25 cm, watering and removing surplus soil to a distance n.exc 50m and making good surfaces complete all as specified and directed.
109S&F in repairs chain link fencing including line wires, any mesh, size and type to any type of standards, rails straining bolts, etc including provision of binding wire complete all as specified and directed. Note: supply only chain link fencing, MS 10mm dia round bars as line wire and MS flat iron shall be measured and paid separately under respective item of this schedule.
110Supply only mild steel galvanised chain link fencing of 50mmx50mm mesh size and 3mm dia wire complete all as specified and directed.
111S&F in repairs galvanised, 2 strand, steel barbed wire, 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of strandard rails straining bolts, including securing and tying at crossing with and provisioning of galvanised mild steel wire, staples or steel pins, etc.complete all as specified and directed. Note: Each line wire shall be measured for payment
112S&F in epairs for replacement of mild steel posts and struts in fencing cutting top to shape as directed, drilling holes, notching for wire etc. flat iron fillets (for securing wire mess etc.) including all necessary drilling, bolting or reveting etc. and similar work conforming to Fe-290 (Gde E-165) complete all as specified and directed.
113S&F in repairs mild steel framed work such as grills, grating etc with end of bars shouldered and or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, wlk ways, raailing, framed ork of water tanks and similar work confirming to FE 290 Gde E-165 mild steel flat iron, round bars etc. in available length complete conforming to Fe-290 (Gde E-165) complete all as specified and directed. Note:- 10mm dia MS rods 3 Nos shall be provided horizontally by inter wewaving in the chain link and welded with MS flat iron complete all as specified
114S&F in repais mild steel screw bolts 5 mm to 10mm dia (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, not exc. 5cm long complete all as specified and directed.
115S&F in repairs Mild steel plates, plain or chequered, 5mm thick or over in thickness in available sizes Fe 410-W (Gde-E-250) quality-complete all as specified and directed.
116M&L for preparation of new steel surface of any description over 10 cm in width or grith and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified
117M&L for preparation of new steel surface of any description not exceeding 10cm in width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57107070
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 56 Lakhs
LAST DATE 16-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repairs / Replacement Of Ht Cables, Jointing Kits, Ht Switch Gear System, Control Panels, 02/04 Pole Structure And Connected External Electrification Network System At Army Area Under Ge Avadi
Basic Detail
Tender No 87787/E8
Bidding Type Tender
Location
City Thiruvallur
State Tamil Nadu
Key Dates
Publish Date 20 Aug 2026
Submission Date 16 Sep 2026
Open Date 18 Sep 2026
Finance
Tender Value 56 Lakhs
Tender Fee 1000
EMD 1.09 Lakhs
Exemption Available
Document List
02ed5e6f-1b45-47ca-9837-1c8bb27e3277.html
87787Tender.pdf
BOQ_880092.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 26 days
Sep 18, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 28 days

Tender Documents

Download All (ZIP) ↓
html

02ed5e6f-1b45-47ca-9837-1c8bb27e3277.html

pdf

87787Tender.pdf

xls

BOQ_880092.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders