Tender For Hvac Works For Dr. Amartyas Lab Ks-210 Sf Cri Actrec
Tender Value
4.04 Lakhs
Estimated cost
Bid Submission
08 Sep 2026
15 days left
EMD
8083
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Raigad → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Hvac Works For Dr. Amartyas Lab Ks-210 Sf Cri Actrec
BOQ
| Sl. No. | Item Description |
| 1 | Variable Refrigerant Flow (VRF)/Variable Refrigerent Volume (VRV) |
| 2 | SITC of Variable Refrigerant Flow (VRF)/Variable Refrigerent Volume (VRV) modular type air-conditioning Equipment complete with indoor and out door units Individual controllers also provide for each indoor units and should be capable of integration with the Computer System based Building Management System of HVAC. |
| 3 | Outdoor Unit (cooling Only) |
| 4 | Supply of Modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s),minimum two compressors (with individual seperate PCB) for above 14HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or any eco friendly gas, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condensor fan shall be capable to operate at different speed with respect to load.The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and CPWD Specifications and work even at 50°C ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 39 Degree Celcius.The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. The Indian Seasonal Energy Efficiency Ratio (ISEER) of the unit shall be as per Energy Conservation and Sustainable Building Code (ECSBC) 2024 as below and complete as per specification, connections, inter connections etc. as required. (For capacity<40 kWr ISEER 7.4, Capacity > 40 and <70 ISEER 7.5, Capacity > 70 ISEER 7.6 for Super ECSBC Building)Note:- Out door unit stand also included in the price. |
| 5 | Supply of following minimum capacity High wall type Indoor unit equipped with and comfort washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC supply, complete as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals. The system shall be capable to adjust air flow as per room requirement automatically. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. (Make will be same as of Outdoor) |
| 6 | Min capacity 2.0TR Hiwall Unit |
| 7 | Refnet joints and other fittings (Per Outdoor) |
| 8 | Design, Supply and Installation of 1.2mm thickness Copper tubing insulated with 19 mm thick class \\"O\\" Nitrile rubber insulation with GC cloth Insulation for 10HP Outdoor units shall be provided with weather proof additional cover for exposed areas. For indoor units tubing of appropriate diameter to be provided. All piping inside the room shall be properly supported with hanger and all internal and external piping shall run in covered cable tray. Piping quantity is mentioned is for pair of suction and discharge pipes. |
| 9 | SITC of communication cable from indoor to outdoor units as per the requirment and as per instructed and as directed by OIC-ES |
| 10 | SITC of power cable for 8HP units from indoor armoured to main MCB as per the requirment and as per the requirment and as per instructed and as directed by OIC-ES |
| 11 | SITC PVC drain pipe having pressure holding of 6kg/cm2 Drain piping complete with all accessories with 9mm Nitrile Rubber Insulation. |
| 12 | 40 mm |
| 13 | Dismantling and safe removal of existing 2 TR Chilled Water Hi-Wall FCU unit including chilled water piping, insulation, drain piping, control wiring, supports and accessories, complete with shifting of dismantled material to designated location and making good of dismantled area as per site conditions and instructions of Engineer-in-Charge. |
| 14 | Reinstallation, testing and commissioning of existing 2 TR Chilled Water Hi-Wall FCU unit including fixing of unit, alignment, electrical reconnection, drain piping connection, valve connection, testing and balancing complete with necessary supports, clamps and accessories as required as per site conditions and instructions of Engineer-in-Charge. Note:- If any additional piping/cable/Insulation up to 5 Mtr require to be consider in the price. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 08, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysSep 09, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓