Housing Urban and Rular Development Government Departments Closing in 9 days TDR #57104163

Tender For Deposit-Providing Ups And Replacing Damaged Fittings At Director Room , Animal Husbandary Department, Vikas Bhavan Thiruvananthapuram-Providing Ups-General Electrical Work

Issued by Government Departments · Thiruvananthapuram, Kerala
Tender Value
Ref. Documents
Estimated cost
Bid Submission
02 Sep 2026
9 days left
EMD
4658
Bank guarantee accepted
Document Fee
555
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Thiruvananthapuram → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Deposit-Providing Ups And Replacing Damaged Fittings At Director Room , Animal Husbandary Department, Vikas Bhavan Thiruvananthapuram-Providing Ups-General Electrical Work

BOQ

Name of Work:- DEPOSIT-Providing UPS and Replacing damaged fittings at Director Room , Animal Husbandary Department, Vikas Bhavan Thiruvananthapuram-Providing UPS-General Electrical Work
Sl. No. Item Description
1providing UPS
2OD119724/2026-2027:Supply, installation, and commissioning of 2kva UPS Single phase in and out. with indoor (IP20) Input pf >0.99, double conversion technology with input voltage range 176-300 @ full load, 50Hz Single Phase, THD of input current should be < 3% at full linear load. output 230V, 50Hz Single phase, It shall be 100% generator compatible, with Efficiency > 92% and output power factor unity ( 2kVA=2kW), Eco mode Efficiency 97% and including all accessories etc as required. The acoustic noise at 1m of the system should be <55dB.The systemshall comply to IEC /EN 62040-1, EN/IEC 62040-2, EN/IEC 62040-3, CE, BIS, ROHS, and relevant IS standards. The system shall be true online double - conversion DSP based UPS system and also UPS shallbe with automatic bypass builtin. The system shall have IGBT rectifier and inverter. warranty 3 years for UPS and batteries. The system shall have a battery back up using 5400 VAH C10 tubular battery system (6 numbers 12V 75AH or equivalent) along with battery stand (UPS make - Numeric/APC/Vertiv - Emerson/Hykon/Delta/Eaton or equivalent) (Battery - Exide EL/Amaron)
31.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
41.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
51.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
61.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
71.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
81.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
91.26:Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
101.28.4:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module
111.28.1:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module
1290.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
1390.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator
142.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)8 way, Double door
152.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole
162.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
172.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required.
182.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
1990.9.2.1:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid
2090.9.2.11:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Cable retainer
2190.9.2.13:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.4 to 5 module mounting box
2290.9.2.12:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.1 to 3 module mounting box
2390.9.2.2:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Cable devider
2490.9.2.4:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Flat angle 90 degree
2590.9.2.8:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.End cap
26OD311429/2024-2025:supply and fixing of 20 mm Corrugated PVC flexible conduit as required
27OD119723/2026-2027:Supply and fixing 3600 lumen square (2ft X 2ft) recessed fitting made of crca sheet of thickness 0.5mm, having efficacy not less than 100l/w, pf greater than 0.95, THD less than or equal to 10%, Chip make Cree/Osram/lumilled/Nichea complete with all accessories and fluorescent lamps etc. suspended from ceiling using 4 nos steel chain (16 SWG or nearest) of length not exceeding 30 cm properly hooked to steel hooks anchored to the ceiling and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required. (Philips FullGlow / Crompton POLARIS NIO / Wipro Immaculate or equivalent)
28OD291745/2024-2025:Supply, Conveyance and fixing charges of recess mounting down light fittings of following type complete with all accessories in the existing opening of false ceiling, giving connections with the existing wire etc., as required.1200 lumen round/ square(1X1) recessed fitting made of diecast aluminium, havingefficacy not less than 110l/w, pf greater than 0.95, THD less than or equal to 10%, Chip makeCree/Osram/lumilled/Nichea Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57104163
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 02-09-2026
Authority
Authority Name Public Works Department
Work Description Tender for Deposit-Providing Ups And Replacing Damaged Fittings At Director Room , Animal Husbandary Department, Vikas Bhavan Thiruvananthapuram-Providing Ups-General Electrical Work
Basic Detail
Tender No PWD/BLDG/TR/3728/2025
Bidding Type Tender
Location
City Thiruvananthapuram
State Kerala
Key Dates
Publish Date 20 Aug 2026
Submission Date 02 Sep 2026
Open Date 03 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee 555
EMD 4658
Exemption Not Available
Document List
39eec341-b03e-453f-a304-a6b184b4da49.html
affi.pdf
agree.pdf
BOQ_1465914.xls
epayment.pdf
form.pdf
IP.pdf
make.pdf
Tendernotice_1.pdf
viewsbd.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Sep 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
html

39eec341-b03e-453f-a304-a6b184b4da49.html

pdf

affi.pdf

pdf

agree.pdf

xls

BOQ_1465914.xls

pdf

epayment.pdf

pdf

form.pdf

pdf

IP.pdf

pdf

make.pdf

pdf

Tendernotice_1.pdf

pdf

viewsbd.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders