Metro Rail Boards / Undertakings / PSU Closing in 15 days TDR #57103429

Tender For Maintenance Contract For Controlling Leakage & Seepage In Underground/Elevated Section Including Tunnel, Stations, Ancillary Buildings, Viaduct And Depot Etc. Of Line-8 From Botanical Garden To Krishna Park Extension & Line-8 Extension Sta

Issued by Boards / Undertakings / PSU · New Delhi, Delhi
Tender Value
2.09 Crore
Estimated cost
Bid Submission
09 Sep 2026
15 days left
EMD
1 Lakhs
Bank guarantee accepted
Document Fee
23600
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Maintenance Contract For Controlling Leakage & Seepage In Underground/Elevated Section Including Tunnel, Stations, Ancillary Buildings, Viaduct And Depot Etc. Of Line-8 From Botanical Garden To Krishna Park Extension & Line-8 Extension Stations.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 20-Aug-2026 Addendum 1 Technical Bid 09-Sep-2026

BOQ

Name of Work:- Maintenance contract for controlling leakage & seepage in Underground/Elevated section including Tunnel, Stations, Ancillary buildings, Viaduct and Depot etc. of Line-8 from Botanical Garden to Krishna Park Extension & Line-8 Extension stations.
Sl. No. Item Description
1Total of Schedule-A (DSR Civil items-2023) and Schedule-B (NDSR Items)
2Total of Schedule-A (DSR Civil items-2023)
3Total of Schedule-B(NDSR items) OCM-2283 APPENDIX- 3A PROFORMA FOR STATEMENT OF MINOR DEVIATIONS (Refer Clause C 2.2(d) and C 15.1 of ITT) 1. The following are the particulars of minor deviations from the requirements of the Tender Document: Sr. No Clause Deviations Price reduction for each deviation/s Note : 1. The Tenderer shall indicate price reduction against each deviation in Appendix-3A of BOQ. This price is the price which the tenderer shall reduce from this tender price if deviation(s) is/are accepted by the Employer. 2. Where there is no deviation, the statement should be returned duly signed with an endorsement indicating ‘No Deviations’. In case, Performa of deviations is not submitted or submitted as blank, it will be construed that the tenderer has not proposed any deviations from tender documents. 3. It shall be noted that in case Nil/Zero/NA Price quoted by Tenderer in Appendix-3A then it shall mean that contractor has quoted same price for deviation and undeviation bid. 4. If the tenderer proposes deviations in tender documents, and/or any other terms and conditions of the tender, other than in this Appendix, it will have no effect. Signature of authorized signatory On behalf of Tenderer OCM-2283 S. No. Preamble
4The Bill of Quantities shall be read in conjunction with Notice Inviting Tenders, Instructions to Tenderers, General and Special Conditions of Contract, Employer's Requirement, Technical Specifications and other relevant documents.
5BoQ1 consists of two schedules i.e. Schedule ‘A’ for DSR Civil Items-2023, Schedule 'B' for NDSR Items.
6Tenderers shall quote their offer in Indian Rupees (₹) only. Tenderers are required to quote percentage (%) Excess/Less for Schedule-A and Schedule-B in figures in the appropriate highlighted cells in the BoQ1 sheet.
7The rates and prices to be tendered in the unit Priced Bill of Quantities are for completed and finished items of works and complete in all respect. It will be deemed to include Duties, Taxes, Octroi, Royalty etc., cost of all plants, labour, supervision, materials, transport, all temporary works, erection, maintenance, utility identification, contractor’s profit and establishment/overheads, together with preparation of design and drawings, all general risks, insurance liabilities, compliance of labour laws and obligations set out or implied in the contracts. For taxes and duties refer clause C2.4 & C2.5 of ITT & relevant clause of SCC.
8The price offer in the BOQ shall be given without considering any deviation mentioned in Appendix-3 of FOT i.e. price in the box shall be quoted as per tender conditions without any deviation.
9If the tenderer fails to quote rates against any item, the tender may be treated as incomplete and non-responsive and shall be rejected.
10Errors will be corrected by the employer for any arithmetical errors in computation or summation as per contract conditions.
11The Financial Proposal (as per BOQ) shall be uploaded online on the website http://etenders.gov.in/eprocure/app. The rates shall be quoted in the excel file provided in the bid documents. The tenderer shall download the excel file and quote the percentage/rates in BoQ1. After quoting their percentage/rates the excel file shall be uploaded accordingly. The rates shall not be offered/quoted elsewhere in the technical submission/ tender submission.
12The actual work executed against all the BOQ as detailed in tender document would be paid on measurement basis.
13The contractor may raise their “On Account” payments on monthly basis as per the status of work on the last day of the respective month as per clause 12 of SCC.
14In case of DSR item the description is given in brief and detailed description of item should be as given in DSR Civil items-2023 published by CPWD. Please Enable Macros to View BoQ information Bill of Quantity (BoQ) Name of Work- OCM-2283: \\"Maintenance contract for controlling leakage & seepage in Underground/Elevated section including Tunnel, Stations, Ancillary buildings, Viaduct and Depot etc. of Line-8 from Botanical Garden to Krishna Park Extension & Line-8 Extension stations\\". Item Code Description of Item Unit Quantity Rate (₹) Amount (₹) SCHEDULE-A (DSR Civil items-2023)
15Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done.
16Providing and injecting approved grout in proportion recommendedby the manufacturer into cracks/honey-comb area of concrete/masonry by suitable gun/pump at required pressure including cuttingof nipples after curing etc. complete as per directions of Engineer-in-Charge.(The payment shall be made on the basis of actual weight of approved grout injected.) 26.35.1 Stirrer mixed Acrylic Polymer of approved make @ 2%of weight of cement used) modified Cement slurry madewith non shrink compound in concrete/RCC work kg 18000.0 119.3 2147400.0 26.35.2 Stirrer mixed SBR Polymer (of approved make) modifiedCement slurry made with Shrinkage Compensating Cement in concrete/RCC work. kg 5000.0 124.0 620000.0 26.35.3 Epoxy injection grout in concrete/RCC work of approved make kg 1000.0 553.4 553400.0
17Providing and inserting 12 mm dia galvanised steel injection nipple in honey comb area and along crack line including drilling of holes of required diametre (20 mm to 30 mm) up to depth from 30 mm to 80 mm at required spacing and making the hole & crack dust free by blowing compressed air, sealing the distance between injection nipple with adhesive chemical of approved make and allow it to cure complete as per direction of Engineer-In-Charge. Any Other DSR Item 2023 800000.0 Total of Schedule-A 4763725.0 Multiplied by correction factor of 0.973 (As per CPWD guidelines) 4635104.43 Total of Schedule-A (after apply of correction factor) (Inclusive of GST@18%) 4635104.43 Total of Schedule-A (Exclusive of GST@18%) 3928054.6 SCHEDULE-B (NDSR Items) NDSR - 1 Providing and injecting microfine injecting grout pagel ZL 10 or equivalent under high pressure up to 30 bar or as per requirement during non traffic hours. Rate inclusive of providing,fixing, cutting of non return packers of required size and repairing the surface with polymer mortar complete at all height. Per kg 3000.0 512.7 1538100.0 NDSR - 2 Core cutting in RCC 100 mm dia and upto 200 mm depth complete including all man, materials, machine etc. complete Each 50.0 2937.72 146886.0 NDSR - 3 GI Sheet tray: Supplying,fabricating,fitting & fixing of GI sheet 18 SWG sheet tray fixing with dash fastner of 100x100 mm with the help of supporting MS flat clamp 50x4 mm and clamp will be fixed on beam by desh fastner Tray will be made/fabricated by the way of rivets NUt/bolts m-seal sealent throughly provided to make the join of tray perfect water proof, rate are inclusive of all tools and plants such as cutter welding set power hammer driller drilling machine etc scaffolding transportation of materials to the site of work and rate also inclusive of all skilled and unskilled labours. Work shall be carried out as per direction of Engineer. Rate are also inclusive of all lead lift ascent and descent etc. complete as per instruction of Engineer-In-Charge. Sqm 100.0 1917.19 191719.0 NDSR - 4 Providing and injecting one-component, solvent-free, low-viscosity, semi-flexible/rigid, minimum 95% closed-cell content as per ASTM D2842:2012b, hydrophobic, polyurethane injection grout i.e. 1C 115 Eco (manufactured by ADCOS ASIA) or HA CUT CFL AF manufactured by Deneef(Saint-Gobain) or equivalent having specification as per manufacturer data sheet for permanent arresting of active water leakages structural concrete members. The injection material shall be applied using high-pressure injection pumps after Identification and preparation of leakage points, Drilling of holes (14 mm diameter or as required) at specified spacing and angles for effective resin penetration, fixing of NRV (Non-Return Valve) injection packers, properly fixed and sealed using rapid-setting plugging mortar, Removal of packers post-injection, grouting of drilled holes with suitable non-shrink grout or epoxy mortar, and making good the surface to match the parent concrete. All work to be done as per manufacturer’s specifications. Rate are inclusive of all labour, materials, drilling, packers, high-pressure equipment, rapid setting mortar, surface restoration, cleaning, taxes, levies, scaffolding, consumables including catalyst if any, carriage of material at site, safety provisions works complete in all respects at all heights and levels. Nothing shall be paid Extra. Per kg 4000.0 1600.0 6400000.0 NDSR - 5 Providing and injecting single-component, low-viscosity, solvent-free, flexible, hydrophilic and possessing 100% solids, polyurethane injection resin i.e. 1C Hydrofoam manufactured by ADCOS ASIA or HA safefoam NF manufactured by Deneef(Saint-Gobain) or equivalent having specification as per manufacturer data sheet for the effective sealing of water ingress in segment joints and other non-structural concrete joints of structure. Application shall be carried out using a high-pressure injection pump after Identification and preparation of leakage points, Drilling of holes (14 mm diameter or as required) at specified spacing and angles for effective resin penetration, fixing of NRV (Non-Return Valve) injection packers, properly fixed and sealed using rapid-setting plugging mortar, removal of packers post-injection, grouting of drilled holes with suitable non-shrink grout or epoxy mortar, and making good the surface to match the parent concrete. All work to be done as per manufacturer’s specifications. Rate are inclusive of all labour, materials, drilling, packers, high-pressure equipment, rapid setting mortar, surface restoration, cleaning, taxes, levies, scaffolding, consumables, carriage of material at site/location, safety provisions works complete in all respects at all heights and levels. Nothing shall be paid Extra. Per kg 5000.0 1600.0 8000000.0 Total of Schedule-B (Inclusive of GST@18%) 16276705.0 Total of Schedule-B (Exclusive of GST@18%) 13793817.8 Grand total of Schedule-A and Schedule-B (Inclusive of all, GST@18%) 20911809.43

AI Tender Summary

OUR REF NO 57103429
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 2.09 Crore
LAST DATE 09-09-2026
Authority
Authority Name Delhi Metro Rail Corporation Limited
Work Description Tender for Maintenance Contract For Controlling Leakage & Seepage In Underground/Elevated Section Including Tunnel, Stations, Ancillary Buildings, Viaduct And Depot Etc. Of Line-8 From Botanical Garden To Krishna Park Extension & Line-8 Extension Stations.
Basic Detail
Tender No OCM-2283
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 20 Aug 2026
Submission Date 09 Sep 2026
Open Date 01 Jan 0001
Finance
Tender Value 2.09 Crore
Tender Fee 23600
EMD 1 Lakhs
Exemption Not Available
Document List
8d6510b0-e0b1-486b-adec-dc7c0f804873.html
BOQ_333892.xls
TenderDoc.rar
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 09, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 15 days
Sep 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
html

8d6510b0-e0b1-486b-adec-dc7c0f804873.html

xls

BOQ_333892.xls

rar

TenderDoc.rar

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders