Tender For Electrical Renovation Work In Wing C, D & E Of Tta Guest House At Barc Staff Colony, Tarapur.
Tender Value
52 Lakhs
Estimated cost
Bid Submission
03 Sep 2026
10 days left
EMD
1.04 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Palghar → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Electrical Renovation Work In Wing C, D & E Of Tta Guest House At Barc Staff Colony, Tarapur.
BOQ
| Sl. No. | Item Description |
| 1 | Removal of complete concealed/surface switch boards, Celling Fans and other electrical fittings in each room of C, D & E wing of TTA Guest House in BARC Staff Colony, Tarapur. |
| 2 | Modification and replacement of Distribution board |
| 3 | Supplying and fixing 8 way , Double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on recess, complete with tinned copper bus bar, Short links for MCB's, neutral bus bar, earthbar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). Civil work required for concelead the DB box is in scope of the contractor. |
| 4 | Supplying and fixing Cable End Box (Loose Wire Box) suitable For 8 way, Double door SPN MCBDB, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. Civil work required for concelead the DB box is in scope of the contractor. |
| 5 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, SP MCB suitable for inductive load of in the above mention DB. complete with connections, testing and commissioning etc. as required. |
| 6 | Supply installation, testing and commissioning of 40A , 2 pole, 2M RCCB(30mA) in the above mention DB. |
| 7 | Supply, installation, testing and commissioning of 1.1KV grade, FRLS PVC insulated wire of following size and laying through casing caping or pulling through conduit pipe safely with out any joint in wire. All wires should be confirm IS:694 with latest amendments. (Red/Yellow/Blue, Black, Green colour) |
| 8 | Supply of 1.5 mm², flexible Multistrand single core copper wire |
| 9 | Installation |
| 10 | 2.5 mm², flexible Multistrand single core copper wire |
| 11 | Supply of 2.5 mm², flexible Multistrand single core copper wire |
| 12 | Installation |
| 13 | 4 mm², flexible Multistrand single core copper wire |
| 14 | Supply of 4 mm², flexible Multistrand single core copper wire |
| 15 | Installation |
| 16 | 0.5mm solid anealed copper Telephone Cable |
| 17 | Supply of 0.5mm solid anealed copper Telephone Cable 1 Pair |
| 18 | Installation |
| 19 | RG-06 Co-axial TV Cable |
| 20 | Supply of RG-06 Co-axial TV Cable |
| 21 | Installation |
| 22 | Replacement of Concealed type Switch boxes :Supply, installation of Modular Concealed type switch boxes with cover plated of following sizes for installation of plate type switches/sockets/telephone sockets/data point junction boxes etc. Civil work required, if any for removal of old concealed boxes and make the surface normal level after refixing of new boxes are in scope of the contractor. |
| 23 | 8 module box with Cover Plate |
| 24 | 6 module box with Cover Plate |
| 25 | 4 module box with Cover Plate |
| 26 | 2 module box with Cover Plate |
| 27 | 1 module box with Cover Plate |
| 28 | Controlling switch & socketsSupply Installation, testing and commissioning of electrical control switche/socket/Regulator etc of following rating. |
| 29 | 6 A switch |
| 30 | 6 A socket |
| 31 | Bell Push with indicator |
| 32 | Blank Plate -1M |
| 33 | Telephone Socket with shutter(RJ 11) -1M |
| 34 | TV Socket -1M |
| 35 | Bell Ding DongSuppy and fixing of Ding Dong bell . |
| 36 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 37 | Lighting FixturesSupply Installation ,testing and commissioning of following lighting fixtures with all control accessories including interconnection from existing boxes. |
| 38 | 0.5 Watt LED Plug-in Night light |
| 39 | 12 Watt LED Square surface mounting fittings |
| 40 | 1200MM BLDC Ceiling FansSupply Installation, testing and commissioning of 1200MM Sweep , BLDC ceiling fan with regulator modular type to be installed on exsisting fan hook operate on 140-285V , 50Hz, AC supply, conforming to relavent IS as per tender specification. |
| 41 | Supply |
| 42 | Installation |
| 43 | 1400MM BLDC Ceiling FansSupply Installation, testing and commissioning of 1400MM Sweep , BLDC ceiling fan with regulator modular type to be installed on exsisting fan hook operate on 140-285V , 50Hz, AC supply, conforming to relavent IS as per tender specification. |
| 44 | Supply |
| 45 | Installation |
| 46 | Exhaust Fan Supply Installation, testing and commissioning of 200mm sweep, High speed, PVC body, Automatic operated shutter Exhaust fan operate on 230V , 50Hz, AC supply, conforming to relavent IS. |
| 47 | Supply |
| 48 | Installation |
| 49 | Air Conditioner Unit Supplying , Installation, Testing and Commissioning of 1.5 TR with 5 Star BEE Rating Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/ R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% ofthe rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS/International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). |
| 50 | Supplying and fixing 20 A rating, 240/415 V, 10 kA, \\"C\\" curve, DP MCB suitable for inductive load with suitable enclosure of complete with connections, testing and commissioning etc. as required. |
| 51 | Electric GeyserSupply, installation, testing and commissioning of 1 ltr, instantaneous type 3KW Geyser, including supply and installation interconnection pipe with 24-Inch long Stainless steel 304 Braided Pipe. |
| 52 | Supply and installation of 20A SP MCB & 2 pin & E Socket with box. |
| 53 | Supply of 1KW,1.5L Stainless Steel Electric Kettle as per IS 367 |
| 54 | PVC ConduitSupply, Installation of medium class(MMS) 25 mm dia. PVC conduit for ceiling/wall/column with all accessories like coupler bend junction boxes. Civil work required for Concealed of conduit pipe is in scope of the contractor. |
| 55 | Supply and Installation of 32 mm x 12 mm x 1.2mm PVC Casing Caping with all accessories such as T, inner outer bend, coupling, junction etc of following Size. Installation of Casing Caping by drilling hole and fixing with 35/8 screw and rawl plug. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 20, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysSep 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender