Tender For Supply Installation Testing and Commissioning of Motor Pump Set Along With Allied Works At East Of Kailash Sps In Constituency Ac-51
Tender Overview
Project Description
Tender for Supply Installation Testing and Commissioning of Motor Pump Set Along With Allied Works At East Of Kailash Sps In Constituency Ac-51 , Providing Of Non-Clog Sewage Handling Pump / Solid Handling Pump Set With Ci Impeller, Ci Body, Ss Shaft & Sleeve, Discharge: 410 M³/Hr, Head: 15-20 Mtr, . Make: Wilo M&P/Kbl/Jyoti/Djb Approved Make. Supply Of Suitable Hp, Standard Totally Enclosed Fan Cooled (Tefc) Squirrel Cage Motors (Enclosure Conforming To Protection Ip55, Horizontal Foot Mounted Induction Motors, Continuously Rated Suitable For Operation On 415±10%, 3‐Phase, 50Hz±5%, Ac Supply With Class F Insulation For An Ambient Of 50 Deg.C And Altitude Less Than 1000M Above Msl And Confirming To Iec: 60034-1 & Is 12615:2018 For Above Specification Pump; Make: Cg/Kirloskar/Abb/Djb Approved Make. Providing Coupling & Coupling Guard For Above Pump Set. The Complete System (I.E. Motor, Pump, Coupling & Coupling Guard Etc.) Should Be Mounted On Fixed- Platform As Per Site Requirement & Direction Of Engineer In Charge. , Providing And Fixing Of Suitable Hp Star Delta (Push Button Start) Starter With Panel Enclosure For Ac Induction Motor And Complete Fitting, Indications And Its Control Circuit, Mccb-3P (125-150A), Mcb, Contactor, Spreader Link, Ct, Timer, Motor Protection Relay, Bus Bars, Voltmeter And Ammeter Etc As Required At Site To Make The Above Pump Set At S. No.1 Fully Operated/Functional. The Panel To Be Fitted In The Panel Room By Using 16 Sq. Mm Copper Cable 3 Core As Per Site Requirement & Direction Of Engineer In Charge. Make: All Components/Wiring In The Panel & For As Required For All Connections Should Be Djb Approved , Fabrication, Supply, Installation And Fixing Of Weather-Proof Ms Canopy For Protection Of Pump Set Against Rainwater, Sunlight And Other Weather Effects, Comprising Ms Square Pipe Frame, Ms Sheet Roofing (Minimum 1.6 Mm Thick), Necessary Supports, Foundation Bolts, Welding, Cutting, Grinding & Other Accessories Complete In All Respects As Per Site Requirement & Direction Of Engineer-In-Charge. , Providing Of Cidf Swing Type, Nrv 150 Mm Dia Confirming To Is 5312, Having Body, Door In Cl To Is, 210 Gr. Fg. 260, Body Ring And Door Ring Of Ltb2. Hinge Pin Of Ss 410, Bearing Block Of Ltb2 As Per Is. 318. Valves Inbuilt With Non Slam Characteristic Flange As Per Is 1538, Pn 1.0. Sor (2024-25) E&M Item Code 4.30.4 Make : Ivc/ Kirloskar/Djb Approved. , Providing Of Cidf Sluice Valve 150 Mm Dia Generally Conforms To Is. 14846 Having Body, Door, Dome Gland In Cl To Is 210 Gr. Fg. 260, Four Faces And Spindle Nut Of Ltb2 As Per 15.318. Non Rising Spindle Of Ss Aisi 410, Pn 1 Rating. Flange Drilled As Per Is 1538, Ipn 1.0 Rating. Sor (2024-25) E&M Item Code 4.29.4 Make: Ivc/ Kirloskar/ Djb Approved . , Providing Of Ms Pipe B Class 150 Mm Dia, Thickness 6 Mm Conforming To Is 1239 Part 1 (2004) Make : Tata/Jindal/ Djb Approved. (Payment Will Be Paid As Per Actual) , Providing Of 150 Mm Dia Ms Bend 90 Degree Of Suitable Thickness, As Per Site Requirement And Direction Of Engineer Incharge. , Providing Of Ms Flanges For 150 Mm Dia Pipe Of Suitable Thickness, As Per Site Requirement And Direction Of Engineer Incharge. , Providing Of High Pressure Packing, As Per Site Requirement And Direction Of Engineer Incharge. , Providing Suitable Nut Bolts & Washer As Required For Installation Of Pump Set And Valve Etc. (Payment Will Be Done As Per Actual Work At Site). , Fabrication/Supply Of Heavy Duty Ms Clamp As Per Requirement At Site For Holding The Suction Line Of Pump At Inlet Sump, As Per Site Requirement And Direction Of Engineer Incharge. , Making Of Reinforced Cement Concrete Foundation Of Size 6.5 Feet X 3 Feet X 3 Feet Height And 3.5 Feet Depth Below Ground For Pump Set, 1:2:4 In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). Work Including Supply And Making Heavy Ms Jaal For Foundation Size As Per Required At Site And Direction Of Engineer Incharge. , Supply Of New Ss Of Size 25 X 300 Mm Foundation Bolt Of Size As Per Sample As Per Site Requirement And Direction Of Engineer Incharge. , Fixing Of The New Foundation Bolt By Proper Welding To Ms Jall Of Reinforced Cement Concrete With Proper Support And Filling Of cement concrete In Ratio 1:2:4 For Grip Of Foundation Bolt In cement concrete Structure And Also Making Wet Layer Of Cement In cement concrete Structure For Proper Mixing And Required Civil Work With Proper Levelling. As Per Site Requirement And Direction Of Engineer Incharge. , Making M.S. Base Frame Size As Per Actual Site Requirement, Made Out Of M.S. Channel Of Size 150 X 75 X 5.7 Mm With Necessary Vertical And Horizontal Supports As Directed By Engineer-In-Charge. The Motor & Pump Shall Hold On Base M.S. Plate 8 Mm Thick M.S Plate For Side Covering From Motor Side, Angle & Flat Etc. And Applying A Priming Coat Of Approved Steel Primer All Complete, As Per Site Requirement And Direction Of Engineer Incharge. , Fixing Of New Base Frames On Foundation With Foundation Bolts. The Job Also Includes Fixing Of Pump And Motor On Foundation Frame And Making Proper Alignment With Suction And Delivery Line Of The Existing System, Fixing Of Delivery Taper And Other Parts With New Nut Bolts And Packing Etc. The Job Also Includes Proper Alignment On M S Frame, As Per Site Requirement And Direction Of Engineer Incharge. , Installation Of All Fittings (Pipe/Nrv/Valve/Bend/ Flange With Tightening Of Nut Bolt & Washer), Including Work Of Making Electrical Connection Of Motor Pump Set. The Work Will Be Executed Through Expert Electrician, Heavy Beldar, Helper, Welder, Cutter, Fitter, Supervisor Chowkidar And Welding Machine, Cutter Set I/C Oxygen Cylinder, Tools & Tackles As Per Site Requirement And Direction Of Engineer Incharge. , Painting Work Of All Above Complete Systems By Using Primer & Minimum 2 Coats Of Enamel Paint Of Required Shade & Colour As Per Site Requirement And Direction Of Engineer Incharge. , Testing And Commissioning Of All The Above At Site At Full Load And No Load With Vibration Free Smooth Operation,As Per Site Requirement And Direction Of Engineer Incharge.
BOQ
| Sl. No. | Item Description |
| 1 | Providing of Non-clog sewage handling pump / solid handling pump set with CI Impeller, CI Body, SS Shaft & Sleeve, Discharge: 410 m³/hr, Head: 15-20 mtr, . Make: WILO M&P/KBL/JYOTI/DJB approved make. Supply of suitable HP, Standard Totally Enclosed Fan Cooled (TEFC) Squirrel Cage Motors (Enclosure Conforming to protection IP55, Horizontal Foot Mounted Induction motors, continuously rated suitable for operation on 415±10%, 3‐Phase, 50Hz±5%, AC Supply with class 'F' insulation for an ambient of 50 Deg.C and altitude less than 1000M above MSL and confirming to IEC: 60034-1 & IS 12615:2018 for above specification pump; Make: CG/Kirloskar/ABB/DJB approved make. Providing coupling & coupling guard for above pump set. The complete system (i.e. Motor, Pump, Coupling & Coupling Guard etc.) should be mounted on fixed- platform as per site requirement & direction of engineer in charge. |
| 2 | Providing and fixing of suitable HP Star Delta (Push Button Start) starter with panel enclosure for AC induction motor and complete fitting, indications and its control circuit, MCCB-3P (125-150A), MCB, Contactor, spreader link, CT, timer, motor protection relay, bus bars, voltmeter and ammeter etc as required at site to make the above pump set at S. No.1 fully operated/functional. The panel to be fitted in the panel room by using 16 sq. mm copper cable 3 core as per site requirement & direction of engineer in charge. Make: All components/wiring in the panel & for as required for all connections should be DJB approved |
| 3 | Fabrication, supply, installation and fixing of weather-proof MS canopy for protection of pump set against rainwater, sunlight and other weather effects, comprising MS square pipe frame, MS sheet roofing (minimum 1.6 mm thick), necessary supports, foundation bolts, welding, cutting, grinding & other accessories complete in all respects as per site requirement & direction of Engineer-in-Charge. |
| 4 | Providing of CIDF swing type, NRV 150 mm dia confirming to IS 5312, having body, door in Cl to IS, 210 Gr. FG. 260, Body ring and door ring of LTB2. Hinge pin of SS 410, Bearing Block of LTB2 as per IS. 318. Valves inbuilt with non slam characteristic Flange as per IS 1538, PN 1.0. SOR (2024-25) E&M Item Code 4.30.4 Make : IVC/ Kirloskar/DJB approved. |
| 5 | Providing of CIDF sluice valve 150 mm dia generally conforms to IS. 14846 having body, door, dome gland in Cl to IS 210 Gr. Fg. 260, four faces and spindle nut of LTB2 as per 15.318. Non Rising spindle of SS AISI 410, PN 1 rating. Flange drilled as per IS 1538, IPN 1.0 rating. SOR (2024-25) E&M Item Code 4.29.4 Make: IVC/ Kirloskar/ DJB approved . |
| 6 | Providing of MS Pipe \\"B\\" Class 150 mm dia, thickness 6 mm conforming to IS 1239 Part 1 (2004) Make : Tata/Jindal/ DJB Approved. (Payment will be paid as per actual) |
| 7 | Providing of 150 mm dia MS Bend 90 degree of suitable thickness, as per site requirement and direction of Engineer Incharge. |
| 8 | Providing of MS Flanges for 150 mm dia pipe of suitable thickness, as per site requirement and direction of Engineer Incharge. |
| 9 | Providing of High pressure packing, as per site requirement and direction of Engineer Incharge. |
| 10 | Providing suitable nut bolts & washer as required for installation of pump set and valve etc. (Payment will be done as per actual work at site). |
| 11 | Fabrication/Supply of heavy duty MS Clamp as per requirement at site for holding the suction line of pump at inlet sump, as per site requirement and direction of Engineer Incharge. |
| 12 | Making of RCC foundation of size 6.5 feet X 3 feet X 3 feet height and 3.5 feet depth below ground for pump set, 1:2:4 in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources). Work including supply and making heavy MS jaal for foundation size as per required at site and direction of Engineer Incharge. |
| 13 | Supply of new SS of size 25 x 300 mm foundation bolt of size as per sample as per site requirement and direction of Engineer Incharge. |
| 14 | Fixing of the new Foundation bolt by proper welding to MS Jall of RCC with proper support and filling of CC in ratio 1:2:4 for grip of foundation bolt in CC structure and also making wet layer of cement in CC Structure for Proper mixing and required civil work with proper levelling. as per site requirement and direction of Engineer Incharge. |
| 15 | Making M.S. Base frame size as per actual site requirement, made out of M.S. Channel of size 150 x 75 x 5.7 mm with necessary vertical and horizontal supports as directed by engineer-in-charge. The motor & pump shall hold on base M.S. plate 8 mm thick M.S plate for side covering from motor side, angle & flat etc. and applying a priming coat of approved steel primer all complete, as per site requirement and direction of Engineer Incharge. |
| 16 | Fixing of new base frames on foundation with foundation bolts. The job also includes fixing of Pump and motor on foundation frame and making proper alignment with suction and delivery line of the existing system, fixing of delivery taper and other parts with new nut bolts and packing etc. The job also includes proper alignment on M S Frame, as per site requirement and direction of Engineer Incharge. |
| 17 | Installation of all fittings (Pipe/NRV/Valve/Bend/ Flange with tightening of Nut bolt & washer), including work of making electrical connection of motor pump set. The work will be executed through expert electrician, heavy beldar, helper, welder, cutter, fitter, supervisor chowkidar and welding machine, cutter set i/c oxygen cylinder, tools & tackles as per site requirement and direction of Engineer Incharge. |
| 18 | Painting work of all above complete systems by using primer & minimum 2 coats of enamel paint of required shade & colour as per site requirement and direction of Engineer Incharge. |
| 19 | Testing and commissioning of all the above at site at full Load and no Load with Vibration free smooth operation,as per site requirement and direction of Engineer Incharge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender