Petroleum and Natural Gas Boards / Undertakings / PSU Closing in 21 days TDR #57101691

Bids Are invited for Custom Bid For Services - Hiring Of Electrical Works At Various Surface Installations Of Rajahmundry Asset - Laying And Jointing Pvc Pipe. Heading , Fabrication Of Vcb Panel With Suitable Mounting Structures And Associated Civil

Issued by Boards / Undertakings / PSU · East Godavari, Andhra Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
10 Sep 2026
21 days left
EMD
93000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
East Godavari → Andhra Pradesh
EMD Exemption
Not Available
Quantity
1

Project Description

Bids Are invited for Custom Bid For Services - Hiring Of Electrical Works At Various Surface Installations Of Rajahmundry Asset - Laying And Jointing Pvc Pipe. Heading , Fabrication Of Vcb Panel With Suitable Mounting Structures And Associated Civil Workssupply, Installation, Testing And Comissioning Of 11Kv 630 S 3 Phase 3Pole 50Hz Outdoor Type Vaccum Circuit Breaker, Along With Protection As Per Is:3427 : 1969, Breaker Including Cts/Pts, Tripping, Closing Coils And Spring Charge Mechanism Etc., As Per Required For Incoming Of The Transformer. The Breaker Unit Shall Consist Of Protective Relay Having Over Current, Over Load, Earth Fault And Other Protections, Built In Power Pack Suitable To Supply Power For Tripping And Closing Mechanism Of The Circuit Breaker. The Breaker Should Be Rack Out Type. Necessary Civil Works For Safe Placement &.Mounting Of Vcb Panel At Site Will Be In The Scope Of The Contractor. Make: Preferably Abb/Siemens/Ge/L&T , Construction Of Earthpitsconstruction Of Earth Pit Shall Be Carried Out Involving Excavation Of Soil, Providing & Fixing Of Earth Electrode Of 3 Meters Length Gi Pipe (Class-B) Having 50 Mm Diameter. Job Shall Also Include Filling Up Of Earth Pit With Earth Enhancement Materials (Viz. Charcoal, Sand, Salt Etc) After Placing The Earth Electrode In The Eaxcavated Earth Pit, Construction Of The Earth Pit Chamber By Providing Bricks, Sand, Cement Etc, Providing & Fixing Of Ms Frame With 6Mm Thick Cover (Chequered Plate) Over Earth Pit, Providing Suitable Funnel With 50Mm To 25Mm Gi Reducer On The Earth Pipe For Water Including Painting, Connection, Tightening Of Earthing Strip With Ss Nut Bolts, Washers Etc And Connecting The Same To Earth Strip/ Earth Grid Etc As Per The Drawings, Specifications And Instructions Of Engineer In –Charge. Measurement Of Earth Pit Resistance And Writing The Resistance Value, Pit Nos. And Date Of Measurement On A Display Board Of Size 15X8, 5Mm Thickness M.S Plate With 35X35x5mm L Angular 2-Ft Long Leg Fixed In Ground Painted Yellow With Letters In Black As Per Instruction Of Engineer In-Charge , Providing, Laying, Fixing And Connecting Of 50X6mm Thick G.I Flat From Earth Pit To Electrical Equipment For Earthing Of Equipment Nearby To Maintain Double Earthing For Each Equipment And As Per Instruction Of Eic , Fabrication And Fixing Of Danger Board Size: 2F X 2F And Name Plate For Transformer. The Danger Board Is To Be Firmly Fixed On Transformer Yard Fencing Gate , Making Power Connections To Vcb And Transformer Ht Terminals By Providing Of 3Cx300 Sqqmm Alu Arm Ht Cable 11Kv (E) Using Suitable Lugs And Necessary Accessories. , Replacement Of Damaged Insulator Of Ht Lines/Structure With A New Insulator 11Kv Along With All The Suitable Accesoroies. , Providing And Fixing Of Heat Shrinkable End Termination Kit Suitable For 300Sqmm Cable , Replacement Of Damaged Lightning Arresters With A New 11 Kv, 10 Ka Line Type Lightning Arresters Along With All The Suitable Accesoroies. , Fabrication Of Vcb Panel With Suitable Mounting Structures And Associated Civil Workssupply, Installation, Testing And Comissioning Of 11Kv 630 S 3 Phase 3Pole 50Hz Outdoor Type Vaccum Circuit Breaker, Along With Protection As Per Is:3427 : 1969, Breaker Including Cts/Pts, Tripping, Closing Coils And Spring Charge Mechanism Etc., As Per Required For Incoming Of The Transformer. The Breaker Unit Shall Consist Of Protective Relay Having Over Current, Over Load, Earth Fault And Other Protections, Built In Power Pack Suitable To Supply Power For Tripping And Closing Mechanism Of The Circuit Breaker. The Breaker Should Be Rack Out Type. Necessary Civil Works For Safe Placement &.Mounting Of Vcb Panel At Site Will Be In The Scope Of The Contractor. Make: Preferably Abb/Siemens/Ge/L&T , Construction Of Earthpitsconstruction Of Earth Pit Shall Be Carried Out Involving Excavation Of Soil, Providing & Fixing Of Earth Electrode Of 3 Meters Length Gi Pipe (Class-B) Having 50 Mm Diameter. Job Shall Also Include Filling Up Of Earth Pit With Earth Enhancement Materials (Viz. Charcoal, Sand, Salt Etc) After Placing The Earth Electrode In The Eaxcavated Earth Pit, Construction Of The Earth Pit Chamber By Providing Bricks, Sand, Cement Etc, Providing & Fixing Of Ms Frame With 6Mm Thick Cover (Chequered Plate) Over Earth Pit, Providing Suitable Funnel With 50Mm To 25Mm Gi Reducer On The Earth Pipe For Water Including Painting, Connection, Tightening Of Earthing Strip With Ss Nut Bolts, Washers Etc And Connecting The Same To Earth Strip/ Earth Grid Etc As Per The Drawings, Specifications And Instructions Of Engineer In –Charge. Measurement Of Earth Pit Resistance And Writing The Resistance Value, Pit Nos. And Date Of Measurement On A Display Board Of Size 15X8, 5Mm Thickness M.S Plate With 35X35x5mm L Angular 2-Ft Long Leg Fixed In Ground Painted Yellow With Letters In Black As Per Instruction Of Engineer In-Charge , Providing, Laying, Fixing And Connecting Of 50X6mm Thick G.I Flat From Earth Pit To Electrical Equipment For Earthing Of Equipment Nearby To Maintain Double Earthing For Each Equipment And As Per Instruction Of Eic , Fabrication And Fixing Of Danger Board Size: 2F X 2F And Name Plate For Transformer. The Danger Board Is To Be Firmly Fixed On Transformer Yard Fencing Gate. , Making Power Connections To Vcb And Transformer Ht Terminals By Providing Of 3Cx300 Sqqmm Alu Arm Ht Cable 11Kv (E) Using Suitable Lugs And Necessary Accessories. , Replacement Of Damaged Insulator Of Ht Lines/Structure With A New Insulator 11Kv Along With All The Suitable Accesoroies. , Providing And Fixing Of Heat Shrinkable End Termination Kit Suitable For 300Sqmm Cable , Replacement Of Damaged Lightning Arresters With A New 11 Kv, 10 Ka Line Type Lightning Arresters Along With All The Suitable Accesoroies. , Supply, Installation, Testing And Commissioning Of Ngr Panel.Ngr & Relay With Double Door Outdoor Panel Of 2 Mm Thick Ms Sheet Steel (Crca) Enclosure (Powder Coated) Of Approx. Dimensions 600 X 1025 X 600 Mm With Canopy And 35 X 35 X 5 Mm Ms L-Angular Stand Of 2Ft Length Of Which 1Ft Below Ground Along With Cement Concrete Foundation For Legs Consist Of Following Components:1.System Particulars: Voltage : 415V + 10%, Frequency : 50Hz, Phase : 3Ph., 4-Wire2.Resistor Specifications:Current: 750 Ma, Rated Resistance: 333.3 Ω Silicon Coated Wire Wound Resistor. Resistor Type: Wire Wound Ni-Cr, Duty Cycle: 10 Sectemperature Rise: 375 °C, Location: Outdoor.Resistance Tolerance : + / -5 %, Standard Followed : Ieee-32 Std3.Cable Gland:From Bottom (High End & Low End), Removable Cable Gland Plate, Gland Plate 2.0Mm4. 10 Sq. Mm Body Stud For Body Earthing5. Wiring: Control Wiring: Shall Be With Min 1 Sq Mm Frls Cu Wire Of Grey Color, Power Wiring: Shall Be With 2.5 Sq Mm Frls Cu. Wire Of Grey Color (1100V Range), Wire Ends To Be Properly Crimped With Copper Lugs And Shall Have Ferrule Numbers.415 V, 750Ma Neutral Grounding Resistor Panel Out Of 14/16 Swg Crca Sheet Steel, Powder Coated & Painted With 631 Shade Of Is:5 With Resistance: 333.3 Ω, Tolerance + 5% With Ngr Monitoring Relay With Suitable Mcb For Control Supply Incoming Along With Emergency Battery Power Pack System (Make: Jvs/Bender Or Equivalent) , Copper Plate Earthingproviding Earth Pit With 600X600x3mm Size Copper Plate (Copper Plate Earth Pit Connected With 2 Runs Of 25X6mm Copper Strip Interconnected At The Top By 50X6mm Thick As Per Drawing) Along With 50Mm Dia 2.5 Mtrs Long Gi Pipe Along With Funnel For Watering Including Filling Of Charcoal And Salt By Alternative Layers As Per Is 3043. The Earth Pit Shall Be Made Of 18X18 Inch Size Of Cast Iron Manhole Cover Including Suitable Brick Wall Chamber Along With Masonry Work Finishing And Painted Green As Per Instructions Of Eic. , Supply, Laying And Termination With Proper Glanding Of Single Core, 70Sq. Mm Copper Flexible Cable Confirming To Relevant Is.From Transformer Neutral To Ngr: Two Runsngr To Two Different Earth Pits: One Run Eachmake Of Cable: Preferably Polycab/ Kei/ Finolex , Control Cable For 230V, 50Hz 1-Phase:Supply, Laying And Termination With Proper Glanding Of 2C X 1.5 Sq.Mm Armoured Copper Cable Confirming To Relevant Is.From Transformer Mccb Incoming To Ngr. , Supply, Installation, Testing And Commissioning Of Ngr Panel.Ngr & Relay With Double Door Outdoor Panel Of 2 Mm Thick Ms Sheet Steel (Crca) Enclosure (Powder Coated) Of Approx. Dimensions 600 X 1025 X 600 Mm With Canopy And 35 X 35 X 5 Mm Ms L-Angular Stand Of 2Ft Length Of Which 1Ft Below Ground Along With Cement Concrete Foundation For Legs Consist Of Following Components:1.System Particulars: Voltage : 415V + 10%, Frequency : 50Hz, Phase : 3Ph., 4-Wire2.Resistor Specifications:Current: 750 Ma, Rated Resistance: 333.3 Ω Silicon Coated Wire Wound Resistor. Resistor Type: Wire Wound Ni-Crduty Cycle: 10 Sectemperature Rise: 375 °C, Location: Outdoor.Resistance Tolerance : + / -5 %Standard Followed : Ieee-32 Std3.Cable Gland: From Bottom (High End & Low End)Removable Cable Gland Plategland Plate 2.0Mm4.10 Sq. Mm Body Stud For Body Earthing5.Wiring: Control Wiring: Shall Be With Min 1 Sq Mm Frls Cu Wire Of Grey Colorpower Wiring: Shall Be With 2.5 Sq Mm Frls Cu. Wire Of Grey Color (1100V Range)Wire Ends To Be Properly Crimped With Copper Lugs And Shall Have Ferrule Numbers.415 V, 750Ma Neutral Grounding Resistor Panel Out Of 14/16 Swg Crca Sheet Steel, Powder Coated & Painted With 631 Shade Of Is:5 With Resistance: 333.3 Ω, Tolerance + 5% With Ngr Monitoring Relay With Suitable Mcb For Control Supply Incoming Along With Emergency Battery Power Pack System (Make: Jvs/Bender Or Equivalent) , Copper Plate Earthingproviding Earth Pit With 600X600x3mm Size Copper Plate (Copper Plate Earth Pit Connected With 2 Runs Of 25X6mm Copper Strip Interconnected At The Top By 50X6mm Thick As Per Drawing) Along With 50Mm Dia 2.5 Mtrs Long Gi Pipe Along With Funnel For Watering Including Filling Of Charcoal And Salt By Alternative Layers As Per Is 3043. The Earth Pit Shall Be Made Of 18X18 Inch Size Of Cast Iron Manhole Cover Including Suitable Brick Wall Chamber Along With Masonry Work Finishing And Painted Green As Per Instructions Of Eic. , Supply, Laying And Termination With Proper Glanding Of Single Core, 70Sq. Mm Copper Flexible Cable Confirming To Relevant Is.From Transformer Neutral To Ngr: Two Runsngr To Two Different Earth Pits: One Run Eachmake Of Cable: Preferably Polycab/ Kei/ Finolex , Control Cable For 230V, 50Hz 1-Phase:Supply, Laying And Termination With Proper Glanding Of 2C X 1.5 Sq.Mm Armoured Copper Cable Confirming To Relevant Is.From Transformer Mccb Incoming To Ngr. , Supply, Installation, Testing And Commissioning Of Ngr Panel.Ngr & Relay With Double Door Outdoor Panel Of 2 Mm Thick Ms Sheet Steel (Crca) Enclosure (Powder Coated) Of Approx. Dimensions 600 X 1025 X 600 Mm With Canopy And 35 X 35 X 5 Mm Ms L-Angular Stand Of 2Ft Length Of Which 1Ft Below Ground Along With Cement Concrete Foundation For Legs Consist Of Following Components:1.System Particulars: Voltage : 415V + 10%, Frequency : 50Hz, Phase : 3Ph., 4-Wire2.Resistor Specifications:Current: 750 Ma, Rated Resistance: 333.3 Ω Silicon Coated Wire Wound Resistor. Resistor Type: Wire Wound Ni-Cr, Duty Cycle: 10 Sectemperature Rise: 375 °C, Location: Outdoor.Resistance Tolerance : + / -5 %Standard Followed : Ieee-32 Std3.Cable Gland:From Bottom (High End & Low End), Removable Cable Gland Plate, Gland Plate 2.0Mm4.10 Sq. Mm Body Stud For Body Earthing5.Wiring: Control Wiring: Shall Be With Min 1 Sq Mm Frls Cu Wire Of Grey Colorpower Wiring: Shall Be With 2.5 Sq Mm Frls Cu. Wire Of Grey Color (1100V Range)Wire Ends To Be Properly Crimped With Copper Lugs And Shall Have Ferrule Numbers.415 V, 750Ma Neutral Grounding Resistor Panel Out Of 14/16 Swg Crca Sheet Steel, Powder Coated & Painted With 631 Shade Of Is:5 With Resistance: 333.3 Ω, Tolerance + 5% With Ngr Monitoring Relay With Suitable Mcb For Control Supply Incoming Along With Emergency Battery Power Pack System (Make: Jvs/Bender Or Equivalent) , Copper Plate Earthingproviding Earth Pit With 600X600x3mm Size Copper Plate (Copper Plate Earth Pit Connected With 2 Runs Of 25X6mm Copper Strip Interconnected At The Top By 50X6mm Thick As Per Drawing) Along With 50Mm Dia 2.5 Mtrs Long Gi Pipe Along With Funnel For Watering Including Filling Of Charcoal And Salt By Alternative Layers As Per Is 3043. The Earth Pit Shall Be Made Of 18X18 Inch Size Of Cast Iron Manhole Cover Including Suitable Brick Wall Chamber Along With Masonry Work Finishing And Painted Green As Per Instructions Of Eic. , Supply, Laying And Termination With Proper Glanding Of Single Core, 70Sq. Mm Copper Flexible Cable Confirming To Relevant Is.From Transformer Neutral To Ngr: Two Runsngr To Two Different Earth Pits: One Run Eachmake Of Cable: Preferably Polycab/ Kei/ Finolex , Control Cable For 230V, 50Hz 1-Phase:Supply, Laying And Termination With Proper Glanding Of 2C X 1.5 Sq.Mm Armoured Copper Cable Confirming To Relevant Is.From Transformer Mccb Incoming To Ngr. , Supply, Installation, Testing And Commissioning Of Ngr Panel.Ngr & Relay With Double Door Outdoor Panel Of 2 Mm Thick Ms Sheet Steel (Crca) Enclosure (Powder Coated) Of Approx. Dimensions 600 X 1025 X 600 Mm With Canopy And 35 X 35 X 5 Mm Ms L-Angular Stand Of 2Ft Length Of Which 1Ft Below Ground Along With Cement Concrete Foundation For Legs Consist Of Following Components:1.System Particulars: Voltage : 415V + 10%, Frequency : 50Hz, Phase : 3Ph., 4-Wire2.Resistor Specifications:Current: 750 Marated Resistance: 333.3 Ω Silicon Coated Wire Wound Resistor. Resistor Type: Wire Wound Ni-Cr, Duty Cycle: 10 Sec, Temperature Rise: 375 °C, Location: Outdoor.Resistance Tolerance : + / -5 %Standard Followed : Ieee-32 Std3.Cable Gland:From Bottom (High End & Low End)Removable Cable Gland Plategland Plate 2.0Mm4.10 Sq. Mm Body Stud For Body Earthing5.Wiring: Control Wiring: Shall Be With Min 1 Sq Mm Frls Cu Wire Of Grey Colorpower Wiring: Shall Be With 2.5 Sq Mm Frls Cu. Wire Of Grey Color (1100V Range)Wire Ends To Be Properly Crimped With Copper Lugs And Shall Have Ferrule Numbers.415 V, 750Ma Neutral Grounding Resistor Panel Out Of 14/16 Swg Crca Sheet Steel, Powder Coated & Painted With 631 Shade Of Is:5 With Resistance: 333.3 Ω, Tolerance + 5% With Ngr Monitoring Relay With Suitable Mcb For Control Supply Incoming Along With Emergency Battery Power Pack System (Make: Jvs/Bender Or Equivalent) , Copper Plate Earthingproviding Earth Pit With 600X600x3mm Size Copper Plate (Copper Plate Earth Pit Connected With 2 Runs Of 25X6mm Copper Strip Interconnected At The Top By 50X6mm Thick As Per Drawing) Along With 50Mm Dia 2.5 Mtrs Long Gi Pipe Along With Funnel For Watering Including Filling Of Charcoal And Salt By Alternative Layers As Per Is 3043. The Earth Pit Shall Be Made Of 18X18 Inch Size Of Cast Iron Manhole Cover Including Suitable Brick Wall Chamber Along With Masonry Work Finishing And Painted Green As Per Instructions Of Eic. , Supply, Laying And Termination With Proper Glanding Of Single Core, 70Sq. Mm Copper Flexible Cable Confirming To Relevant Is.From Transformer Neutral To Ngr: Two Runsngr To Two Different Earth Pits: One Run Eachmake Of Cable: Preferably Polycab/ Kei/ Finolex , Control Cable For 230V, 50Hz 1-Phase:Supply, Laying And Termination With Proper Glanding Of 2C X 1.5 Sq.Mm Armoured Copper Cable Confirming To Relevant Is.From Transformer Mccb Incoming To Ngr. , Supply, Installation, Testing And Commissioning Of Ngr Panel.Ngr & Relay With Double Door Outdoor Panel Of 2 Mm Thick Ms Sheet Steel (Crca) Enclosure (Powder Coated) Of Approx. Dimensions 600 X 1025 X 600 Mm With Canopy And 35 X 35 X 5 Mm Ms L-Angular Stand Of 2Ft Length Of Which 1Ft Below Ground Along With Cement Concrete Foundation For Legs Consist Of Following Components:1.System Particulars: Voltage : 415V + 10%, Frequency : 50Hz, Phase : 3Ph., 4-Wire2.Resistor Specifications: Current: 750 Marated Resistance: 333.3 Ω Silicon Coated Wire Wound Resistor. Resistor Type: Wire Wound Ni-Cr, Duty Cycle: 10 Sec, Temperature Rise: 375 °C, Location: Outdoor.Resistance Tolerance : + / -5 %Standard Followed : Ieee-32 Std3.Cable Gland:From Bottom (High End & Low End)Removable Cable Gland Plategland Plate 2.0Mm4.10 Sq. Mm Body Stud For Body Earthing5.Wiring: Control Wiring: Shall Be With Min 1 Sq Mm Frls Cu Wire Of Grey Colorpower Wiring: Shall Be With 2.5 Sq Mm Frls Cu. Wire Of Grey Color (1100V Range)Wire Ends To Be Properly Crimped With Copper Lugs And Shall Have Ferrule Numbers.415 V, 750Ma Neutral Grounding Resistor Panel Out Of 14/16 Swg Crca Sheet Steel, Powder Coated & Painted With 631 Shade Of Is:5 With Resistance: 333.3 Ω, Tolerance + 5% With Ngr Monitoring Relay With Suitable Mcb For Control Supply Incoming Along With Emergency Battery Power Pack System (Make: Jvs/Bender Or Equivalent) , Copper Plate Earthingproviding Earth Pit With 600X600x3mm Size Copper Plate (Copper Plate Earth Pit Connected With 2 Runs Of 25X6mm Copper Strip Interconnected At The Top By 50X6mm Thick As Per Drawing) Along With 50Mm Dia 2.5 Mtrs Long Gi Pipe Along With Funnel For Watering Including Filling Of Charcoal And Salt By Alternative Layers As Per Is 3043. The Earth Pit Shall Be Made Of 18X18 Inch Size Of Cast Iron Manhole Cover Including Suitable Brick Wall Chamber Along With Masonry Work Finishing And Painted Green As Per Instructions Of Eic. , Supply, Laying And Termination With Proper Glanding Of Single Core, 70Sq. Mm Copper Flexible Cable Confirming To Relevant Is.From Transformer Neutral To Ngr: Two Runsngr To Two Different Earth Pits: One Run Eachmake Of Cable: Preferably Polycab/ Kei/ Finolex , Control Cable For 230V, 50Hz 1-Phase:Supply, Laying And Termination With Proper Glanding Of 2C X 1.5 Sq.Mm Armoured Copper Cable Confirming To Relevant Is.From Transformer Mccb Incoming To Ngr. , Supply, Installation, Testing And Commissioning Of Ngr Panel.Ngr & Relay With Double Door Outdoor Panel Of 2 Mm Thick Ms Sheet Steel (Crca) Enclosure (Powder Coated) Of Approx. Dimensions 600 X 1025 X 600 Mm With Canopy And 35 X 35 X 5 Mm Ms L-Angular Stand Of 2Ft Length Of Which 1Ft Below Ground Along With Cement Concrete Foundation For Legs Consist Of Following Components:1.System Particulars: Voltage : 415V + 10%, Frequency : 50Hz, Phase : 3Ph., 4-Wire2.Resistor Specifications: Current: 750 Marated Resistance: 333.3 Ω Silicon Coated Wire Wound Resistor. Resistor Type: Wire Wound Ni-Cr, Duty Cycle: 10 Sec, Temperature Rise: 375 °C, Location: Outdoor.Resistance Tolerance : + / -5 %Standard Followed : Ieee-32 Std3.Cable Gland:From Bottom (High End & Low End)Removable Cable Gland Plategland Plate 2.0Mm4.10 Sq. Mm Body Stud For Body Earthing5.Wiring: Control Wiring: Shall Be With Min 1 Sq Mm Frls Cu Wire Of Grey Colorpower Wiring: Shall Be With 2.5 Sq Mm Frls Cu. Wire Of Grey Color (1100V Range)Wire Ends To Be Properly Crimped With Copper Lugs And Shall Have Ferrule Numbers.415 V, 750Ma Neutral Grounding Resistor Panel Out Of 14/16 Swg Crca Sheet Steel, Powder Coated & Painted With 631 Shade Of Is:5 With Resistance: 333.3 Ω, Tolerance + 5% With Ngr Monitoring Relay With Suitable Mcb For Control Supply Incoming Along With Emergency Battery Power Pack System (Make: Jvs/Bender Or Equivalent) , Copper Plate Earthingproviding Earth Pit With 600X600x3mm Size Copper Plate (Copper Plate Earth Pit Connected With 2 Runs Of 25X6mm Copper Strip Interconnected At The Top By 50X6mm Thick As Per Drawing) Along With 50Mm Dia 2.5 Mtrs Long Gi Pipe Along With Funnel For Watering Including Filling Of Charcoal And Salt By Alternative Layers As Per Is 3043. The Earth Pit Shall Be Made Of 18X18 Inch Size Of Cast Iron Manhole Cover Including Suitable Brick Wall Chamber Along With Masonry Work Finishing And Painted Green As Per Instructions Of Eic. , Supply, Laying And Termination With Proper Glanding Of Single Core, 70Sq. Mm Copper Flexible Cable Confirming To Relevant Is.From Transformer Neutral To Ngr: Two Runsngr To Two Different Earth Pits: One Run Eachmake Of Cable: Preferably Polycab/ Kei/ Finolex , Control Cable For 230V, 50Hz 1-Phase:Supply, Laying And Termination With Proper Glanding Of 2C X 1.5 Sq.Mm Armoured Copper Cable Confirming To Relevant Is.From Transformer Mccb Incoming To Ngr.

AI Tender Summary

OUR REF NO 57101691
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 10-09-2026
Authority
Authority Name Oil And Natural Gas Corporation Limited
Work Description Bids Are invited for Custom Bid For Services - Hiring Of Electrical Works At Various Surface Installations Of Rajahmundry Asset - Laying And Jointing Pvc Pipe. Heading , Fabrication Of Vcb Panel With Suitable Mounting Structures And Associated Civil Workssupply, Installation, Testing And Comissioning Of 11Kv 630 S 3 Phase 3Pole 50Hz Outdoor Type Vaccum Circuit Breaker, Along With Protection As Per Is:3427 : 1969, Breaker Including Cts/Pts, Tripping, Closing Coils And Spring Charge Mechanism Etc., As Per Required For Incoming Of The Transformer. The Breaker Unit Shall Consist Of Protective Relay Having Over Current, Over Load, Earth Fault And Other Protections, Built In Power Pack Suitable To Supply Power For Tripping And Closing Mechanism Of The Circuit Breaker. The Breaker Should Be Rack Out Type. Necessary Civil Works For Safe Placement &.Mounting Of Vcb Panel At Site Will Be In The Scope Of The Contractor. Make: Preferably Abb/Siemens/Ge/L&T , Construction Of Earthpitsconstruction Of Earth Pit Shall Be Carried Out Involving Excavation Of Soil, Providing & Fixing Of Earth Electrode Of 3 Meters Length Gi Pipe (Class-B) Having 50 Mm Diameter. Job Shall Also Include Filling Up Of Earth Pit With Earth Enhancement Materials (Viz. Charcoal, Sand, Salt Etc) After Placing The Earth Electrode In The Eaxcavated Earth Pit, Construction Of The Earth Pit Chamber By Providing Bricks, Sand, Cement Etc, Providing & Fixing Of Ms Frame With 6Mm Thick Cover (Chequered Plate) Over Earth Pit, Providing Suitable Funnel With 50Mm To 25Mm Gi Reducer On The Earth Pipe For Water Including Painting, Connection, Tightening Of Earthing Strip With Ss Nut Bolts, Washers Etc And Connecting The Same To Earth Strip/ Earth Grid Etc As Per The Drawings, Specifications And Instructions Of Engineer In –Charge. Measurement Of Earth Pit Resistance And Writing The Resistance Value, Pit Nos. And Date Of Measurement On A Display Board Of Size 15X8, 5Mm Thickness M.S Plate With 35X35x5mm L Angular 2-Ft Long Leg Fixed In Ground Painted Yellow With Letters In Black As Per Instruction Of Engineer In-Charge , Providing, Laying, Fixing And Connecting Of 50X6mm Thick G.I Flat From Earth Pit To Electrical Equipment For Earthing Of Equipment Nearby To Maintain Double Earthing For Each Equipment And As Per Instruction Of Eic , Fabrication And Fixing Of Danger Board Size: 2F X 2F And Name Plate For Transformer. The Danger Board Is To Be Firmly Fixed On Transformer Yard Fencing Gate , Making Power Connections To Vcb And Transformer Ht Terminals By Providing Of 3Cx300 Sqqmm Alu Arm Ht Cable 11Kv (E) Using Suitable Lugs And Necessary Accessories. , Replacement Of Damaged Insulator Of Ht Lines/Structure With A New Insulator 11Kv Along With All The Suitable Accesoroies. , Providing And Fixing Of Heat Shrinkable End Termination Kit Suitable For 300Sqmm Cable , Replacement Of Damaged Lightning Arresters With A New 11 Kv, 10 Ka Line Type Lightning Arresters Along With All The Suitable Accesoroies. , Fabrication Of Vcb Panel With Suitable Mounting Structures And Associated Civil Workssupply, Installation, Testing And Comissioning Of 11Kv 630 S 3 Phase 3Pole 50Hz Outdoor Type Vaccum Circuit Breaker, Along With Protection As Per Is:3427 : 1969, Breaker Including Cts/Pts, Tripping, Closing Coils And Spring Charge Mechanism Etc., As Per Required For Incoming Of The Transformer. The Breaker Unit Shall Consist Of Protective Relay Having Over Current, Over Load, Earth Fault And Other Protections, Built In Power Pack Suitable To Supply Power For Tripping And Closing Mechanism Of The Circuit Breaker. The Breaker Should Be Rack Out Type. Necessary Civil Works For Safe Placement &.Mounting Of Vcb Panel At Site Will Be In The Scope Of The Contractor. Make: Preferably Abb/Siemens/Ge/L&T , Construction Of Earthpitsconstruction Of Earth Pit Shall Be Carried Out Involving Excavation Of Soil, Providing & Fixing Of Earth Electrode Of 3 Meters Length Gi Pipe (Class-B) Having 50 Mm Diameter. Job Shall Also Include Filling Up Of Earth Pit With Earth Enhancement Materials (Viz. Charcoal, Sand, Salt Etc) After Placing The Earth Electrode In The Eaxcavated Earth Pit, Construction Of The Earth Pit Chamber By Providing Bricks, Sand, Cement Etc, Providing & Fixing Of Ms Frame With 6Mm Thick Cover (Chequered Plate) Over Earth Pit, Providing Suitable Funnel With 50Mm To 25Mm Gi Reducer On The Earth Pipe For Water Including Painting, Connection, Tightening Of Earthing Strip With Ss Nut Bolts, Washers Etc And Connecting The Same To Earth Strip/ Earth Grid Etc As Per The Drawings, Specifications And Instructions Of Engineer In –Charge. Measurement Of Earth Pit Resistance And Writing The Resistance Value, Pit Nos. And Date Of Measurement On A Display Board Of Size 15X8, 5Mm Thickness M.S Plate With 35X35x5mm L Angular 2-Ft Long Leg Fixed In Ground Painted Yellow With Letters In Black As Per Instruction Of Engineer In-Charge , Providing, Laying, Fixing And Connecting Of 50X6mm Thick G.I Flat From Earth Pit To Electrical Equipment For Earthing Of Equipment Nearby To Maintain Double Earthing For Each Equipment And As Per Instruction Of Eic , Fabrication And Fixing Of Danger Board Size: 2F X 2F And Name Plate For Transformer. The Danger Board Is To Be Firmly Fixed On Transformer Yard Fencing Gate. , Making Power Connections To Vcb And Transformer Ht Terminals By Providing Of 3Cx300 Sqqmm Alu Arm Ht Cable 11Kv (E) Using Suitable Lugs And Necessary Accessories. , Replacement Of Damaged Insulator Of Ht Lines/Structure With A New Insulator 11Kv Along With All The Suitable Accesoroies. , Providing And Fixing Of Heat Shrinkable End Termination Kit Suitable For 300Sqmm Cable , Replacement Of Damaged Lightning Arresters With A New 11 Kv, 10 Ka Line Type Lightning Arresters Along With All The Suitable Accesoroies. , Supply, Installation, Testing And Commissioning Of Ngr Panel.Ngr & Relay With Double Door Outdoor Panel Of 2 Mm Thick Ms Sheet Steel (Crca) Enclosure (Powder Coated) Of Approx. Dimensions 600 X 1025 X 600 Mm With Canopy And 35 X 35 X 5 Mm Ms L-Angular Stand Of 2Ft Length Of Which 1Ft Below Ground Along With Cement Concrete Foundation For Legs Consist Of Following Components:1.System Particulars: Voltage : 415V + 10%, Frequency : 50Hz, Phase : 3Ph., 4-Wire2.Resistor Specifications:Current: 750 Ma, Rated Resistance: 333.3 Ω Silicon Coated Wire Wound Resistor. Resistor Type: Wire Wound Ni-Cr, Duty Cycle: 10 Sectemperature Rise: 375 °C, Location: Outdoor.Resistance Tolerance : + / -5 %, Standard Followed : Ieee-32 Std3.Cable Gland:From Bottom (High End & Low End), Removable Cable Gland Plate, Gland Plate 2.0Mm4. 10 Sq. Mm Body Stud For Body Earthing5. Wiring: Control Wiring: Shall Be With Min 1 Sq Mm Frls Cu Wire Of Grey Color, Power Wiring: Shall Be With 2.5 Sq Mm Frls Cu. Wire Of Grey Color (1100V Range), Wire Ends To Be Properly Crimped With Copper Lugs And Shall Have Ferrule Numbers.415 V, 750Ma Neutral Grounding Resistor Panel Out Of 14/16 Swg Crca Sheet Steel, Powder Coated & Painted With 631 Shade Of Is:5 With Resistance: 333.3 Ω, Tolerance + 5% With Ngr Monitoring Relay With Suitable Mcb For Control Supply Incoming Along With Emergency Battery Power Pack System (Make: Jvs/Bender Or Equivalent) , Copper Plate Earthingproviding Earth Pit With 600X600x3mm Size Copper Plate (Copper Plate Earth Pit Connected With 2 Runs Of 25X6mm Copper Strip Interconnected At The Top By 50X6mm Thick As Per Drawing) Along With 50Mm Dia 2.5 Mtrs Long Gi Pipe Along With Funnel For Watering Including Filling Of Charcoal And Salt By Alternative Layers As Per Is 3043. The Earth Pit Shall Be Made Of 18X18 Inch Size Of Cast Iron Manhole Cover Including Suitable Brick Wall Chamber Along With Masonry Work Finishing And Painted Green As Per Instructions Of Eic. , Supply, Laying And Termination With Proper Glanding Of Single Core, 70Sq. Mm Copper Flexible Cable Confirming To Relevant Is.From Transformer Neutral To Ngr: Two Runsngr To Two Different Earth Pits: One Run Eachmake Of Cable: Preferably Polycab/ Kei/ Finolex , Control Cable For 230V, 50Hz 1-Phase:Supply, Laying And Termination With Proper Glanding Of 2C X 1.5 Sq.Mm Armoured Copper Cable Confirming To Relevant Is.From Transformer Mccb Incoming To Ngr. , Supply, Installation, Testing And Commissioning Of Ngr Panel.Ngr & Relay With Double Door Outdoor Panel Of 2 Mm Thick Ms Sheet Steel (Crca) Enclosure (Powder Coated) Of Approx. Dimensions 600 X 1025 X 600 Mm With Canopy And 35 X 35 X 5 Mm Ms L-Angular Stand Of 2Ft Length Of Which 1Ft Below Ground Along With Cement Concrete Foundation For Legs Consist Of Following Components:1.System Particulars: Voltage : 415V + 10%, Frequency : 50Hz, Phase : 3Ph., 4-Wire2.Resistor Specifications:Current: 750 Ma, Rated Resistance: 333.3 Ω Silicon Coated Wire Wound Resistor. Resistor Type: Wire Wound Ni-Crduty Cycle: 10 Sectemperature Rise: 375 °C, Location: Outdoor.Resistance Tolerance : + / -5 %Standard Followed : Ieee-32 Std3.Cable Gland: From Bottom (High End & Low End)Removable Cable Gland Plategland Plate 2.0Mm4.10 Sq. Mm Body Stud For Body Earthing5.Wiring: Control Wiring: Shall Be With Min 1 Sq Mm Frls Cu Wire Of Grey Colorpower Wiring: Shall Be With 2.5 Sq Mm Frls Cu. Wire Of Grey Color (1100V Range)Wire Ends To Be Properly Crimped With Copper Lugs And Shall Have Ferrule Numbers.415 V, 750Ma Neutral Grounding Resistor Panel Out Of 14/16 Swg Crca Sheet Steel, Powder Coated & Painted With 631 Shade Of Is:5 With Resistance: 333.3 Ω, Tolerance + 5% With Ngr Monitoring Relay With Suitable Mcb For Control Supply Incoming Along With Emergency Battery Power Pack System (Make: Jvs/Bender Or Equivalent) , Copper Plate Earthingproviding Earth Pit With 600X600x3mm Size Copper Plate (Copper Plate Earth Pit Connected With 2 Runs Of 25X6mm Copper Strip Interconnected At The Top By 50X6mm Thick As Per Drawing) Along With 50Mm Dia 2.5 Mtrs Long Gi Pipe Along With Funnel For Watering Including Filling Of Charcoal And Salt By Alternative Layers As Per Is 3043. The Earth Pit Shall Be Made Of 18X18 Inch Size Of Cast Iron Manhole Cover Including Suitable Brick Wall Chamber Along With Masonry Work Finishing And Painted Green As Per Instructions Of Eic. , Supply, Laying And Termination With Proper Glanding Of Single Core, 70Sq. Mm Copper Flexible Cable Confirming To Relevant Is.From Transformer Neutral To Ngr: Two Runsngr To Two Different Earth Pits: One Run Eachmake Of Cable: Preferably Polycab/ Kei/ Finolex , Control Cable For 230V, 50Hz 1-Phase:Supply, Laying And Termination With Proper Glanding Of 2C X 1.5 Sq.Mm Armoured Copper Cable Confirming To Relevant Is.From Transformer Mccb Incoming To Ngr. , Supply, Installation, Testing And Commissioning Of Ngr Panel.Ngr & Relay With Double Door Outdoor Panel Of 2 Mm Thick Ms Sheet Steel (Crca) Enclosure (Powder Coated) Of Approx. Dimensions 600 X 1025 X 600 Mm With Canopy And 35 X 35 X 5 Mm Ms L-Angular Stand Of 2Ft Length Of Which 1Ft Below Ground Along With Cement Concrete Foundation For Legs Consist Of Following Components:1.System Particulars: Voltage : 415V + 10%, Frequency : 50Hz, Phase : 3Ph., 4-Wire2.Resistor Specifications:Current: 750 Ma, Rated Resistance: 333.3 Ω Silicon Coated Wire Wound Resistor. Resistor Type: Wire Wound Ni-Cr, Duty Cycle: 10 Sectemperature Rise: 375 °C, Location: Outdoor.Resistance Tolerance : + / -5 %Standard Followed : Ieee-32 Std3.Cable Gland:From Bottom (High End & Low End), Removable Cable Gland Plate, Gland Plate 2.0Mm4.10 Sq. Mm Body Stud For Body Earthing5.Wiring: Control Wiring: Shall Be With Min 1 Sq Mm Frls Cu Wire Of Grey Colorpower Wiring: Shall Be With 2.5 Sq Mm Frls Cu. Wire Of Grey Color (1100V Range)Wire Ends To Be Properly Crimped With Copper Lugs And Shall Have Ferrule Numbers.415 V, 750Ma Neutral Grounding Resistor Panel Out Of 14/16 Swg Crca Sheet Steel, Powder Coated & Painted With 631 Shade Of Is:5 With Resistance: 333.3 Ω, Tolerance + 5% With Ngr Monitoring Relay With Suitable Mcb For Control Supply Incoming Along With Emergency Battery Power Pack System (Make: Jvs/Bender Or Equivalent) , Copper Plate Earthingproviding Earth Pit With 600X600x3mm Size Copper Plate (Copper Plate Earth Pit Connected With 2 Runs Of 25X6mm Copper Strip Interconnected At The Top By 50X6mm Thick As Per Drawing) Along With 50Mm Dia 2.5 Mtrs Long Gi Pipe Along With Funnel For Watering Including Filling Of Charcoal And Salt By Alternative Layers As Per Is 3043. The Earth Pit Shall Be Made Of 18X18 Inch Size Of Cast Iron Manhole Cover Including Suitable Brick Wall Chamber Along With Masonry Work Finishing And Painted Green As Per Instructions Of Eic. , Supply, Laying And Termination With Proper Glanding Of Single Core, 70Sq. Mm Copper Flexible Cable Confirming To Relevant Is.From Transformer Neutral To Ngr: Two Runsngr To Two Different Earth Pits: One Run Eachmake Of Cable: Preferably Polycab/ Kei/ Finolex , Control Cable For 230V, 50Hz 1-Phase:Supply, Laying And Termination With Proper Glanding Of 2C X 1.5 Sq.Mm Armoured Copper Cable Confirming To Relevant Is.From Transformer Mccb Incoming To Ngr. , Supply, Installation, Testing And Commissioning Of Ngr Panel.Ngr & Relay With Double Door Outdoor Panel Of 2 Mm Thick Ms Sheet Steel (Crca) Enclosure (Powder Coated) Of Approx. Dimensions 600 X 1025 X 600 Mm With Canopy And 35 X 35 X 5 Mm Ms L-Angular Stand Of 2Ft Length Of Which 1Ft Below Ground Along With Cement Concrete Foundation For Legs Consist Of Following Components:1.System Particulars: Voltage : 415V + 10%, Frequency : 50Hz, Phase : 3Ph., 4-Wire2.Resistor Specifications:Current: 750 Marated Resistance: 333.3 Ω Silicon Coated Wire Wound Resistor. Resistor Type: Wire Wound Ni-Cr, Duty Cycle: 10 Sec, Temperature Rise: 375 °C, Location: Outdoor.Resistance Tolerance : + / -5 %Standard Followed : Ieee-32 Std3.Cable Gland:From Bottom (High End & Low End)Removable Cable Gland Plategland Plate 2.0Mm4.10 Sq. Mm Body Stud For Body Earthing5.Wiring: Control Wiring: Shall Be With Min 1 Sq Mm Frls Cu Wire Of Grey Colorpower Wiring: Shall Be With 2.5 Sq Mm Frls Cu. Wire Of Grey Color (1100V Range)Wire Ends To Be Properly Crimped With Copper Lugs And Shall Have Ferrule Numbers.415 V, 750Ma Neutral Grounding Resistor Panel Out Of 14/16 Swg Crca Sheet Steel, Powder Coated & Painted With 631 Shade Of Is:5 With Resistance: 333.3 Ω, Tolerance + 5% With Ngr Monitoring Relay With Suitable Mcb For Control Supply Incoming Along With Emergency Battery Power Pack System (Make: Jvs/Bender Or Equivalent) , Copper Plate Earthingproviding Earth Pit With 600X600x3mm Size Copper Plate (Copper Plate Earth Pit Connected With 2 Runs Of 25X6mm Copper Strip Interconnected At The Top By 50X6mm Thick As Per Drawing) Along With 50Mm Dia 2.5 Mtrs Long Gi Pipe Along With Funnel For Watering Including Filling Of Charcoal And Salt By Alternative Layers As Per Is 3043. The Earth Pit Shall Be Made Of 18X18 Inch Size Of Cast Iron Manhole Cover Including Suitable Brick Wall Chamber Along With Masonry Work Finishing And Painted Green As Per Instructions Of Eic. , Supply, Laying And Termination With Proper Glanding Of Single Core, 70Sq. Mm Copper Flexible Cable Confirming To Relevant Is.From Transformer Neutral To Ngr: Two Runsngr To Two Different Earth Pits: One Run Eachmake Of Cable: Preferably Polycab/ Kei/ Finolex , Control Cable For 230V, 50Hz 1-Phase:Supply, Laying And Termination With Proper Glanding Of 2C X 1.5 Sq.Mm Armoured Copper Cable Confirming To Relevant Is.From Transformer Mccb Incoming To Ngr. , Supply, Installation, Testing And Commissioning Of Ngr Panel.Ngr & Relay With Double Door Outdoor Panel Of 2 Mm Thick Ms Sheet Steel (Crca) Enclosure (Powder Coated) Of Approx. Dimensions 600 X 1025 X 600 Mm With Canopy And 35 X 35 X 5 Mm Ms L-Angular Stand Of 2Ft Length Of Which 1Ft Below Ground Along With Cement Concrete Foundation For Legs Consist Of Following Components:1.System Particulars: Voltage : 415V + 10%, Frequency : 50Hz, Phase : 3Ph., 4-Wire2.Resistor Specifications: Current: 750 Marated Resistance: 333.3 Ω Silicon Coated Wire Wound Resistor. Resistor Type: Wire Wound Ni-Cr, Duty Cycle: 10 Sec, Temperature Rise: 375 °C, Location: Outdoor.Resistance Tolerance : + / -5 %Standard Followed : Ieee-32 Std3.Cable Gland:From Bottom (High End & Low End)Removable Cable Gland Plategland Plate 2.0Mm4.10 Sq. Mm Body Stud For Body Earthing5.Wiring: Control Wiring: Shall Be With Min 1 Sq Mm Frls Cu Wire Of Grey Colorpower Wiring: Shall Be With 2.5 Sq Mm Frls Cu. Wire Of Grey Color (1100V Range)Wire Ends To Be Properly Crimped With Copper Lugs And Shall Have Ferrule Numbers.415 V, 750Ma Neutral Grounding Resistor Panel Out Of 14/16 Swg Crca Sheet Steel, Powder Coated & Painted With 631 Shade Of Is:5 With Resistance: 333.3 Ω, Tolerance + 5% With Ngr Monitoring Relay With Suitable Mcb For Control Supply Incoming Along With Emergency Battery Power Pack System (Make: Jvs/Bender Or Equivalent) , Copper Plate Earthingproviding Earth Pit With 600X600x3mm Size Copper Plate (Copper Plate Earth Pit Connected With 2 Runs Of 25X6mm Copper Strip Interconnected At The Top By 50X6mm Thick As Per Drawing) Along With 50Mm Dia 2.5 Mtrs Long Gi Pipe Along With Funnel For Watering Including Filling Of Charcoal And Salt By Alternative Layers As Per Is 3043. The Earth Pit Shall Be Made Of 18X18 Inch Size Of Cast Iron Manhole Cover Including Suitable Brick Wall Chamber Along With Masonry Work Finishing And Painted Green As Per Instructions Of Eic. , Supply, Laying And Termination With Proper Glanding Of Single Core, 70Sq. Mm Copper Flexible Cable Confirming To Relevant Is.From Transformer Neutral To Ngr: Two Runsngr To Two Different Earth Pits: One Run Eachmake Of Cable: Preferably Polycab/ Kei/ Finolex , Control Cable For 230V, 50Hz 1-Phase:Supply, Laying And Termination With Proper Glanding Of 2C X 1.5 Sq.Mm Armoured Copper Cable Confirming To Relevant Is.From Transformer Mccb Incoming To Ngr. , Supply, Installation, Testing And Commissioning Of Ngr Panel.Ngr & Relay With Double Door Outdoor Panel Of 2 Mm Thick Ms Sheet Steel (Crca) Enclosure (Powder Coated) Of Approx. Dimensions 600 X 1025 X 600 Mm With Canopy And 35 X 35 X 5 Mm Ms L-Angular Stand Of 2Ft Length Of Which 1Ft Below Ground Along With Cement Concrete Foundation For Legs Consist Of Following Components:1.System Particulars: Voltage : 415V + 10%, Frequency : 50Hz, Phase : 3Ph., 4-Wire2.Resistor Specifications: Current: 750 Marated Resistance: 333.3 Ω Silicon Coated Wire Wound Resistor. Resistor Type: Wire Wound Ni-Cr, Duty Cycle: 10 Sec, Temperature Rise: 375 °C, Location: Outdoor.Resistance Tolerance : + / -5 %Standard Followed : Ieee-32 Std3.Cable Gland:From Bottom (High End & Low End)Removable Cable Gland Plategland Plate 2.0Mm4.10 Sq. Mm Body Stud For Body Earthing5.Wiring: Control Wiring: Shall Be With Min 1 Sq Mm Frls Cu Wire Of Grey Colorpower Wiring: Shall Be With 2.5 Sq Mm Frls Cu. Wire Of Grey Color (1100V Range)Wire Ends To Be Properly Crimped With Copper Lugs And Shall Have Ferrule Numbers.415 V, 750Ma Neutral Grounding Resistor Panel Out Of 14/16 Swg Crca Sheet Steel, Powder Coated & Painted With 631 Shade Of Is:5 With Resistance: 333.3 Ω, Tolerance + 5% With Ngr Monitoring Relay With Suitable Mcb For Control Supply Incoming Along With Emergency Battery Power Pack System (Make: Jvs/Bender Or Equivalent) , Copper Plate Earthingproviding Earth Pit With 600X600x3mm Size Copper Plate (Copper Plate Earth Pit Connected With 2 Runs Of 25X6mm Copper Strip Interconnected At The Top By 50X6mm Thick As Per Drawing) Along With 50Mm Dia 2.5 Mtrs Long Gi Pipe Along With Funnel For Watering Including Filling Of Charcoal And Salt By Alternative Layers As Per Is 3043. The Earth Pit Shall Be Made Of 18X18 Inch Size Of Cast Iron Manhole Cover Including Suitable Brick Wall Chamber Along With Masonry Work Finishing And Painted Green As Per Instructions Of Eic. , Supply, Laying And Termination With Proper Glanding Of Single Core, 70Sq. Mm Copper Flexible Cable Confirming To Relevant Is.From Transformer Neutral To Ngr: Two Runsngr To Two Different Earth Pits: One Run Eachmake Of Cable: Preferably Polycab/ Kei/ Finolex , Control Cable For 230V, 50Hz 1-Phase:Supply, Laying And Termination With Proper Glanding Of 2C X 1.5 Sq.Mm Armoured Copper Cable Confirming To Relevant Is.From Transformer Mccb Incoming To Ngr.
Basic Detail
Tender No GEM/2026/B/7937657
Bidding Type Tender
Location
City East Godavari
State Andhra Pradesh
Key Dates
Publish Date 20 Aug 2026
Submission Date 10 Sep 2026
Open Date 10 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 93000
Exemption Not Available
Document List
b133a7f2-f31f-4b8d-a22f-6016c6f850bf.pdf
1787138768.xlsx
1787138795.pdf
1787138799.pdf
1787138805.pdf
1787138810.pdf
1787138817.pdf
1787138839.pdf
1787138851.pdf
1787138880.pdf
1787138888.pdf
1787138895.pdf
1787138916.pdf
SLA_GCC_d08b12dc-f8b0-4078-ac801787199778834_buyer17.ongc.rjy.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 20, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Sep 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 21 days
Sep 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
pdf

b133a7f2-f31f-4b8d-a22f-6016c6f850bf.pdf

xlsx

1787138768.xlsx

pdf

1787138795.pdf

pdf

1787138799.pdf

pdf

1787138805.pdf

pdf

1787138810.pdf

pdf

1787138817.pdf

pdf

1787138839.pdf

pdf

1787138851.pdf

pdf

1787138880.pdf

pdf

1787138888.pdf

pdf

1787138895.pdf

pdf

1787138916.pdf

ongc

SLA_GCC_d08b12dc-f8b0-4078-ac801787199778834_buyer17.ongc.rjy.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders