Bids Are invited for Renovation And Alteration Of Internal Wiring With All Fitting In Gym Pcda
Tender Overview
Project Description
Bids Are invited for Renovation And Alteration Of Internal Wiring With All Fitting In Gym Pcda Taking Down Existing Point Wiring - Taking Down Existing Point Wiring Of Light Point Exhaust Fan Ceiling Fan Switch Socket Any Size With Due Care And Refixing Cleaning Painting If Required Including Connecting Item All Complete As Specified And Directed , One Light Point Controlled By One Switch - One Light Point Controlled By One Switch. , One Wall Fan Exhaust Fan Ceiling Fan - One Wall Fan Exhaust Fan Ceiling Fan Point Controlled By One Switch. , One 3 Pin Socket Outlet Point - One 3 Pin Socket Outlet Point 5 S On Independent With Cables 1.5 Sqmm Size . , One 3 Pin Socket Outlet Point 5 S - One 3 Pin Socket Outlet Point 5 S On The Same Board With Other Switches. , One 3 Pin Socket Outlet Point 15 S On Independent - One 3 Pin Socket Outlet Point 15 S On Independent With Cables 4 Sqmm Size . , Taking Down Existing Tube Light Bulb - Taking Down Existing Tube Light Bulb With Due Care And Refixing Cleaning Painting If Required Including Connecting Item All Complete As Specified And Directed By Eng In Charge. , Supply And Fixing For Energy Saving Environmental - Supply And Fixing For Energy Saving Environmental Friendly Led Tubelight Fittings 20 Watts 1200 Mm Aluminium Body Long Life Impact Proof Surface Wall Mounting Ip 20 95 Luminaries Per Watt Extruded Aluminium Housing With Frosted Pmpa Diffuser High Brightness Leds Complete With All Accessories Pre-Wired Twin Core Twisted Flexible Copper Conductor Cable With Suitable Size With Ceiling Rose Complete All As Specified And Directed. , Supply And Fixing Led Light Fitting Mirror Type - Supply And Fixing Led Light Fitting Mirror Type With High Out Put Diffuser 2 Feet 10 Watt 220 V Ac Decorative Type With Driver Holder And Led L Including Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size Complete , Supply And Fixing Led Luminaire 600 Mm - Supply And Fixing Led Luminaire 600 Mm X 600 Mm 35 By 36 Watt 220 V Ac Recessed Type With High Efficiency Pmma Diffuser Soft Glare Free Light Complete With Driver Holders And Led L Suitable For Roof Ceiling Including Connecting Up With Driver Three Core Flexible Copper Conductor Cases Of Suitable Size Complete. , Material And Labour L Holder Pvc P - Material And Labour L Holder Pvc Polycarbonate Type With Back Plate Suitable For Batten Fittings , Supply And Fixing Modular Switch - Supply And Fixing Modular Switch 1 Way 6A 1 Module , Supply And Fixing Modular Switch 1 Way - Supply And Fixing Modular Switch 1 Way 16A 1 Module , Supply And Fixing Modular Socket 6A - Supply And Fixing Modular Socket 6A 2 By 3 Pin Combined 2 Module Independent Socket Specified And Directed By Eng In Charge. , Supply And Fixing Modular Socket - Supply And Fixing Modular Socket 6A By 16A 2 By 3 Pin Combined 2 Module , Supply And Fixing Modular Fan - Supply And Fixing Modular Fan Regulator Fan Step Regulator 120W 2Module , Supply And Fixing Modular White Cover Plate With - Supply And Fixing Modular White Cover Plate With Frame White Cover Plate With Frame 3 Module , Supply And Fixing Modular White Cover Plate - Supply And Fixing Modular White Cover Plate With Frame White Cover Plate With Frame 6 Module , Supply And Fixing Modular White Cover - Supply And Fixing Modular White Cover Plate With Frame White Cover Plate With Frame 8 Module , Supply And Fixing Modular - Supply And Fixing Modular White Cover Plate With Frame White Cover Plate With Frame 12 Module , Material And Labour Ceiling Rose 3 Phase Pvc - Material And Labour Ceiling Rose 3 Phase Pvc Polycarbonate Isolated Body , Material And Labour Boxes Junctions Plastic - Material And Labour Boxes Junctions Plastic Round Four Terminals , Material And Labour For Sub Main - Material And Labour For Sub Main Wiring With Two Single Core Frls Pvc Insulated Stranded Unsheathed Cable Copper Conductor With Size 10 Sqmm And Drawing Through And Including Non Metallic Pvc Conduit Concealed In Wall Including Earth Continuity Conductor Of Size 10 Sqmm Pvc Insulated Unsheathed Stranded Copper Conductor Cable And Connected To Earth Dolly To Be Drawn In Ccocealed Pvc Conduit Including Connecting To Main Board Complete All As Specified And Directed By Engineer In Charge. , Material And Labour For Sub Main Wiring With Two Single - Material And Labour For Sub Main Wiring With Two Single Core Frls Pvc Insulated Stranded Unsheathed Cable Copper Conductor With Size 06 Sqmm And Drawing Through And Including Non Metallic Pvc Conduit Concealed In Wall Including Earth Continuity Conductor Of Size 06 Sqmm Pvc Insulated Unsheathed Stranded Copper Conductor Cable And Connected To Earth Dolly To Be Drawn In Ccocealed Pvc Conduit Including Connecting To Main Board Complete All As Specified And Directed By Engineer In Charge. , Supply And Fixing Sheet Metal Enclosures - Supply And Fixing Sheet Metal Enclosures With Socket Plug Top And 20 Mcb 240 Volts Double Pole And Neutral Enclosures With Two Pin And Earth Plug And Socket Complete Double Door Type Complete All As Specified And Directed By Engineer In Charge. , Material And Labour For Shifting Of Split Type Ac - Material And Labour For Shifting Of Split Type Ac Window Type Ac Capacity Upto 2 Ton From Old Position And Refixing To New Position Including Drilling Cutting Chasing And Making Good On Existing Surface Of Pcc Concreting White Cement Plastering And All Necessary Items Including Transporting Of Acs From One Location To Other Location In Pcda (Nc) Jammu And Handing Over The Machine Equipment In Serviceable Condition To The User Including Fixing To New Location And Supply And Fixing Drain Pipe Where Not Present All As Specified And Directed By Engineer In Charge. , Taking Down Existing Exhaust Fan - Taking Down Existing Exhaust Fan Ceiling Fan Any Size With Due Care And Refixing With New Lock Bolt Where Required And New Fan Rod Upto 03 Ft So That Fan Mob Can Hang Beyond False Ceiling After Servicing And Cleaning Painting If Required Including Connecting Electrically Using Pvc Insulated Overall Sheathed Flexible Copper Conductor Cable 0.75 Mm All As Required And Directed. , Taking Down Existing Dbs Box Mccb - Taking Down Existing Dbs Box Mccb Mcb Tpn Spn Sp Any Size With Due Care And Refixing Cleaning Painting If Required Including Connecting Item All Complete As Specified And Directed By Eng In Charge. , Supply And Fixing Mcb Double Door - Supply And Fixing Mcb Double Door Distribution Board Single Pole And Neutral 240 Volt 12 Way With 200 S Bus Bar Complete All As Specified And Directed. , Supply And Fixing Sheet Metal Encloser - Supply And Fixing Sheet Metal Encloser Distribution Board Vtpn Double Door 415 Volt 8 Way With Main Incomming Mccb And Outgoing Mcb Dbs Box All Complete As Specified And Directed By Eng In Charge. , Sp 6 To 32 , Spn 40 To 63 , Supply Laying Commissioning Ug Cable Xlpe - Supply Laying Commissioning Ug Cable Xlpe Insulated Screened Pvc Bedded Galvanized Steel Strip Or Wire Armoured Electric Power Cables Heavy Duty 1100 Volts Grade With Stranded Aluminium Conductor Of Size 70 Sqmm 3.5 Core Cable Complete All As Specified And Directed By Engr In Charge. , Excavation In Trenches Not Exceeding - Excavation In Trenches Not Exceeding 1.5M Wide And Not Exceeding 1.5M In Depth And Getting Out In Any Type Of Soil For Laying Of Lt Ug Cables Complete All As Specified And Directed By Eng In Charge. , Returning Filling In Including Spreading Levelling - Returning Filling In Including Spreading Levelling Watering And Well Ramming In Layers Not Exceeding 25 Cm Thick In Hard Dense Soil Complete All As Specified And Directed By Eng In Charge. , Removing Excavated Material Not Exceeding - Removing Excavated Material Not Exceeding 50M And Depositing Where Directed At A Level Not Exceeding 1.5M Above The Starting Point Complete All As Specified And Directed By Eng In Charge. , Material And Labour For Sand Cushioning - Material And Labour For Sand Cushioning Below And Around Cable In Trenches With Rever Sand All As Specified . , Material And Labour For Unreinforced Precast - Material And Labour For Unreinforced Precast Concrete Cable Cover Class Lv Type 1 Flat Of Size 250 X 150 X 40 Mm For Cable Protection Complete All As Specified And As Directed By Eic
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Taking down existing point wiring | Taking down existing point wiring of light point exhaust fan ceiling fan switch socket any size with due care and refixing cleaning painting if required including connecting item all complete as specified and directed |
| 2 | One light point controlled by one switch | One light point controlled by one switch. |
| 3 | One wall fan exhaust fan ceiling fan | One wall fan exhaust fan ceiling fan point controlled by one switch. |
| 4 | One 3 pin socket outlet point | One 3 pin socket outlet point 5 amps on independent with cables 1.5 sqmm size . |
| 5 | One 3 pin socket outlet point 5 amps | One 3 pin socket outlet point 5 amps on the same board with other switches. |
| 6 | One 3 pin socket outlet point 15 amps on independent | One 3 pin socket outlet point 15 amps on independent with cables 4 sqmm size . |
| 7 | Taking down existing tube light bulb | Taking down existing tube light bulb with due care and refixing cleaning painting if required including connecting item all complete as specified and directed by Eng in Charge. |
| 8 | Supply and fixing for energy saving environmental | Supply and fixing for energy saving environmental friendly LED tubelight fittings 20 watts 1200 mm Aluminium body long life impact proof surface wall mounting IP 20 95 luminaries per watt extruded aluminium housing with frosted PMPA diffuser high brightness LEDs complete with all accessories pre-wired twin core twisted flexible copper conductor cable with suitable size with ceiling rose complete all as specified and directed. |
| 9 | Supply and fixing LED light fitting mirror type | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete |
| 10 | Supply and fixing LED luminaire 600 mm | Supply and fixing LED luminaire 600 mm x 600 mm 35 by 36 watt 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver holders and LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. |
| 11 | Material and Labour Lamp holder PVC P | Material and Labour Lamp holder PVC Polycarbonate type with back plate suitable for batten fittings |
| 12 | Supply and fixing Modular switch | Supply and fixing Modular switch 1 way 6A 1 module |
| 13 | Supply and fixing Modular switch 1 way | Supply and fixing Modular switch 1 way 16A 1 module |
| 14 | Supply and fixing Modular Socket 6A | Supply and fixing Modular Socket 6A 2 by 3 pin combined 2 module Independent socket specified and directed by Eng in Charge. |
| 15 | Supply and fixing Modular Socket | Supply and fixing Modular Socket 6A by 16A 2 by 3 pin combined 2 module |
| 16 | Supply and fixing modular fan | Supply and fixing modular fan regulator Fan step regulator 120W 2module |
| 17 | Supply and fixing modular white cover plate with | Supply and fixing modular white cover plate with frame White cover plate with frame 3 module |
| 18 | Supply and fixing modular white cover plate | Supply and fixing modular white cover plate with frame White cover plate with frame 6 module |
| 19 | Supply and fixing modular white cover | Supply and fixing modular white cover plate with frame White cover plate with frame 8 module |
| 20 | Supply and fixing modular | Supply and fixing modular white cover plate with frame White cover plate with frame 12 module |
| 21 | Material and Labour Ceiling rose 3 phase PVC | Material and Labour Ceiling rose 3 phase PVC polycarbonate isolated body |
| 22 | Material and Labour Boxes junctions plastic | Material and Labour Boxes junctions plastic round four terminals |
| 23 | Material and Labour for sub main | Material and Labour for sub main wiring with two single core FRLS PVC insulated stranded unsheathed cable copper conductor with size 10 Sqmm and drawing through and including Non metallic PVC conduit concealed in wall including earth continuity conductor of size 10 Sqmm PVC insulated unsheathed stranded copper conductor cable and connected to earth dolly to be drawn in ccocealed PVC conduit including connecting to main board complete all as specified and directed by Engineer in Charge. |
| 24 | Material and Labour for sub main wiring with two single | Material and Labour for sub main wiring with two single core FRLS PVC insulated stranded unsheathed cable copper conductor with size 06 Sqmm and drawing through and including Non metallic PVC conduit concealed in wall including earth continuity conductor of size 06 Sqmm PVC insulated unsheathed stranded copper conductor cable and connected to earth dolly to be drawn in ccocealed PVC conduit including connecting to main board complete all as specified and directed by Engineer in Charge. |
| 25 | Supply and fixing sheet metal enclosures | Supply and fixing sheet metal enclosures with socket plug top and 20 Amp MCB 240 Volts double pole and neutral enclosures with two pin and earth plug and socket complete double door type complete all as specified and directed by Engineer in Charge. |
| 26 | Material and Labour for shifting of split type AC | Material and Labour for shifting of split type AC window type AC capacity upto 2 ton from old position and refixing to new position including drilling cutting chasing and making good on existing surface of PCC concreting white cement plastering and all necessary items including transporting of ACs from one location to other location in PCDA (NC) Jammu and handing over the machine equipment in serviceable condition to the user including fixing to new location and supply and fixing drain pipe where not present all as specified and directed by Engineer in Charge. |
| 27 | Taking down existing exhaust fan | Taking down existing exhaust fan ceiling fan any size with due care and refixing with new lock bolt where required and new fan rod upto 03 ft so that fan mob can hang beyond false ceiling after servicing and cleaning painting if required including connecting electrically using PVC insulated overall sheathed flexible copper conductor cable 0.75 mm all as required and directed. |
| 28 | Taking down existing DBs box MCCB | Taking down existing DBs box MCCB MCB TPN SPN SP any size with due care and refixing cleaning painting if required including connecting item all complete as specified and directed by Eng in Charge. |
| 29 | Supply and fixing MCB Double door | Supply and fixing MCB Double door distribution board single pole and neutral 240 volt 12 way with 200 Amps bus bar complete all as specified and directed. |
| 30 | Supply and fixing sheet metal encloser | Supply and fixing sheet metal encloser distribution board VTPN Double door 415 Volt 8 way with main incomming MCCB and outgoing MCB DBs box all complete as specified and directed by Eng in Charge. |
| 31 | SP 6 To 32 AMP | SP 6 To 32 AMP |
| 32 | SPN 40 to 63 AMP | SPN 40 to 63 AMP |
| 33 | Supply laying commissioning UG cable XLPE | Supply laying commissioning UG cable XLPE Insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables Heavy duty 1100 Volts grade with stranded aluminium conductor of size 70 sqmm 3.5 core cable complete all as specified and directed by Engr in Charge. |
| 34 | Excavation in trenches not exceeding | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in any type of soil for laying of LT UG cables complete all as specified and directed by Eng in Charge. |
| 35 | Returning filling in including spreading levelling | Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm thick in hard dense soil complete all as specified and directed by Eng in Charge. |
| 36 | Removing excavated material not exceeding | Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Eng in Charge. |
| 37 | Material and labour for sand cushioning | Material and labour for sand cushioning below and around cable in trenches with rever sand all as specified . |
| 38 | Material and Labour for unreinforced precast | Material and Labour for unreinforced precast concrete cable cover class LV type 1 flat of size 250 x 150 x 40 mm for cable protection complete all as specified and as directed by EIC |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender