Tender For Water Proofing Treatment To Certain Bldgs In Tech Area And 256 Su Kaluchak At Af Stn Jammu Under Ge Af Jammu
Tender Value
16 Lakhs
Estimated cost
Bid Submission
10 Sep 2026
18 days left
EMD
32000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jammu → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Water Proofing Treatment To Certain Bldgs In Tech Area And 256 Su Kaluchak At Af Stn Jammu Under Ge Af Jammu
BOQ
| Sl. No. | Item Description |
| 1 | M&L for Taking down of old roof treatment of any description including demolition of mud phuska, lime concrete, tile, cement plaster, padding upto 30cm depth for roof surfaces and preparation of surface by scrapping and properly cleaning the surface to remove loose particles/ existing vegetation/ roots etc with wire brushes and filling of cracks with smart care Hybrid PU Sealent wherever required and for rendering plastering work 10 mm thick in CM 1:3 on PCC padding and finishing the surface without using extra cement for application of roof treatment. (A) Apply first coat of fibre reinforced elastomeric liquid water proofing membrane formulated with PU hybrid polymers and reinforcing acrylic fibres with sun reflectivity index (SRI) of 100-110, having minimum elongation of 350%, tensile strength 2.9 MPa and shall have crack bridging ability upto 2.5mm and shall resist 10 bars of hydrostatic pressure , reduce surface temperature upto 10 degree celsius with 33% dilution as primming coat.(B) Laying of fibre mesh of 0.3mm thickness weaven in leno pattern having weight 45 gm/Sqm and pasting it properly with overlap of 50mm and allow it to dry.(C) Apply second undiluted coat @ 0.450 ltr/Sqm (D) Apply third and final coat undiluted @ 0.450Ltr/Sqm as directed by Engr-in-charge. Note : Application of water proofing treatment will be done Authorised applicator only/ or in presence of authorised rep. Certificate in this regard shall be submitted to Engr-in-charge. Shifting/removal of any wire/ cable/AC unit etc as per the site requirement and refixing of the same if needed is deemed to be included in rates quoted by contractor.Removing of all rubbish outside MOD land complete also included without any extra payment. |
| 2 | All as per item No 1 above but in patches,chajjas,fascia or near spouts complete all as specified and directed by Engr-in-charge. |
| 3 | Taking down cement plaster on brick or concrete surfaces any description including raking out joints hacking for key scrubbing down with water complete all as specified and directed by Engr-in-charge. |
| 4 | M&L for Rendering 15mm thick in cement mortar 1:4 over Stone /brick/concrete wall surfaces finishing the surfaces even and smooth without using extra cement from top of roof level/parapet wall upto chajja level including scaffolding for plastering workscomplete all as specified and directed by Engr-in-charge. NOTE: THE RATE QUOTED BY CONTRACTOR SHALL BE INCLUSIVE OF SCAFFOLDING UPTO G+2 HEIGHT OF BUILDING. |
| 5 | M&L Preparing new surfaces plastered or unplastered/ roof surfaces and Finishing walls with applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade/ camoflage pattern (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces as specified and approved by Engr-in-Charge complete all as specified and directed by Eng-in-Charge. |
| 6 | M&L for preparing damaged irregular surface of chajjas,roof projections,ceiling,facia etc average 15mm thick in Cement Mortar 1:4 over cement slurry coat thick @ 3 Kg/sqm making the surface even followed by 5mm thick rendering in Cement Mortar 1:3 furnished even & smooth all as specified and as directed by Engr-in-charge. Note :Rate for form work / scaffolding if required to be included in the rate quoted by the contractor. |
| 7 | M&L for providing cement concrete type B0, 1:2:4 (20mm graded crushed stone aggregate) set in cement mortar 1:4 in coping , kneelers and in similarly works including necessary form work all as specified and as directed by Engr-in-charge |
| 8 | M&L brick work with sub class B bricks straight or curved on plan 6m mean radius built in Cement Mortar 1:6 including Demolition of brick work stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc all as specified and as directed by Engr-in-charge |
| 9 | M&L PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) as in cement concrete in sub-floors, sub-bases, floors and pavings, padding over roof slab and average thickness of 25 mm as per site requirement for receiving top layer over roof surface treated with bonding chemical on old surface as per manufacturers instruction, etc similar workscomplete all as specified and directed by Engr-in-charge. |
| 10 | Demolition of cement concrete(unreinforced)/lime concrete/brick tiles of any description and in any position not specifically provided including removal of debris from MOD land at contractor own expensecomplete all as specified and directed by Engr-in-charge. |
| 11 | S&F in repair 110mm dia PVC (SWR) pipes single socketed in any length fixed to wall including clamps as required complete all as specified and as directed by Engr-in-charge.Note: All arrangements to fix the pipe upto height of 30m will be done by contractor at no extra cost. |
| 12 | S&F for in Repair PVC (SWR) bend & shoes etc for 110mm dia pipe fixed in repair complete all as specified and directed by Engr-in-charge. |
| 13 | Disconnecting existing tanks, setting aside for (or lowering if required) cleaning and removing all scale and dirt etc. from tanks and from mouths and circulating pipes and hoisting in same position with PCC/ Brick base repair if required at site for tanks of capacity upto and including 500 ltr and endorsed the word \\"CLEANED ON WITH DATE\\" .(Tank should be marked with stencil letter cutting Complete Date and Year with enamel paint. including replacement of broken/ unserviceable fitting such as Elbow Tee, socket, nipple of any size complete all as specified and directed by Engr-in-charge. |
| 14 | Disconnecting existing tanks, setting aside for (or lowering if required) cleaning and removing all scale and dirt etc. from tanks and from mouths and circulating pipes and hoisted in same position with PCC/ Brick base repair if required at site for tanks of capacity above 500 ltrs and upto and including 1000 ltr and endorsed the word \\"CLEANED ON WITH DATE\\" .(Tank should be marked with stencil letter cutting Complete Date and Year with enamel paint. including replacement of broken/ unserviceable fitting such as Elbow Tee, socket, nipple of any size complete all as specified and directed by Engr-in-charge. |
| 15 | S&F PVC rotational moulded polyethiene water storage tanks triple layered of capacity 500 litres Blue/White/Black colour as specified, (cylindrical vertical with closed top) hoisted including PCC/ Bk repair if required (measured separately) , and fixed in position including S&F necessary GI fittings, inlet/outlet washout, overflow pieces long nipples, checknuts & washer ,brass valve 20mm high pressure with polythene float and fly nut etc complete including dismantling existing water tanks Rcc/Iron/Pvc complete all as specified and directed by Engr-in-charge. Tank should be marked with stencil letter cutting Date and Year with enamel paint. |
| 16 | S&F PVC rotational moulded polyethiene water storage tanks triple layered of capacity 1000 litres , Blue/White/Black colour as specified , (cylindrical vertical with closed top) hoisted including PCC/ Brick Base repair if required(will be measured separately) and fixed in position including S & F necessary GI fittings, inlet/outlet washout, overflow pieces long nipples, checknuts & washer ,brass valve 20mm high pressure with polythene float and fly nut etc complete including dismantling existing water tanks Rcc/Iron/Pvc complete all as specified and directed by Engr-in-charge. Tank should be marked with stencil letter cutting Date and Year with enamel paint. |
| 17 | M&L taking down 15/20 mm bore GI tubing ,fitting and connections etc complete all as specified and as directed by Engr-in-charge |
| 18 | Refixing of old steel tubing 15/20 mm medium grade galvanized with all fittings short pieces, joints sealed and fixed complete to walls, floor etc all as specified and as directed by Engr-in-charge |
| 19 | S&F 15mm bore medium grade galvanised tube with all fittings and fixed complete to walls and ceilings or laid in floors including taking down pipe all as specified and directed by Engr-in-Charge. |
| 20 | S&F 20mm bore medium grade galvanised tube with all fittings and fixed complete to walls and ceilings or laid in floors including taking down pipe all as specified and directed by Engr-in-Charge. |
| 21 | S&F in repair PVC lid for poly water storage tanks of capacity 500L including PVC hinges and PVC locking/ threaded type both complete all as specified and directed by Engr-in-charge. |
| 22 | S&F in repair PVC lid for poly water storage tanks of capacity 1000L including PVC hingesand PVC locking both complete all as specified and directed by Engr-in-charge. |
| 23 | S&F in repair 20mm Ball brass valves, high pressure, with polythenefloat and flynut complete, screwed for iron pipe or brass ferrule and fixedcomplete all as specified and directed by Engr-in-Charge. |
| 24 | SCHEDULE 'A' PART-II (Schedule of credit) Credit amount of Rs (Refer schedule of credit) for retrieved material mentioned in Sch 'A' Part-II of Tender documents in PDF form will be deducted offline during acceptance of tender of lowest bidder. + Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 20, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysSep 17, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 25 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender