Defence Statutory Bodies & Commissions/Committees Closing in 18 days TDR #57101009

Tender For special Repair To Sewage Line Manholes And Safety Tanks From Otm-79 Of 19 Sikh Li At Barrackpore Under Ge Barrackpore

Issued by Statutory Bodies & Commissions/Committees · 24 Paraganas North, West Bengal
Tender Value
47.76 Lakhs
Estimated cost
Bid Submission
09 Sep 2026
18 days left
EMD
95520
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
24 Paraganas North → West Bengal
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for special Repair To Sewage Line Manholes And Safety Tanks From Otm-79 Of 19 Sikh Li At Barrackpore Under Ge Barrackpore

BOQ

Name of Work:- SPL REPAIR TO SEWAGE LINE MANHOLES AND SAFETY TANKS FROM OTM-79 OF 19 SIKH LI AT BARRACKPORE UNDER GE BARRACKPORE
Sl. No. Item Description
1Excavation in trenches not exc 1.50 m wide and not exc 1.50 m deep for foundation, laying of pipe or for shafts, wells cesspits, man holes, pier holes, laying of cable etc not exc 10 Sqm on plan and n exc 1.5m in depth and getting out in soft / loose soil complete all as specified and as directed.
2Excavation in trenches not exceeding 1.5 m wide for foundation or for shafts, wells, cesspits, manholes, pier holes etc. not exc 10 sqm on plan and exceeding 1.50 in depth but not exc 3.0 m and getting out soft/loose soil complete all as specified and directed
3Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm in soft / loose soil complete all as specified and as directed.
4Removing excavated soil to distance not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point etc complete all as specified and as directed.
5Demolition of plain cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed.
6M & L for PCC 1:4:8 Type D-2 ( Using 40 mm graded crushed stone aggregate) as in foundation , filling, and mass concrete complete all as specified and directed.
7M & L for PCC 1:2:4, type B1 (using 20 mm graded crushed stone aggregate) as in coping, cills, hold fasts, fixing of post, water trough etc. including necessary formwork (straight or curved) complete all as specified and as directed.
8M&L for extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and as directed.
9Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for all as specified and as directed.
10M & L for precast RCC cover slab, 1:1.5:3 type A-1,(Using 20 mm graded crushed stone aggregate ) as in drain/manhole cover slab etc., and set in cement mortar 1:4 including necessary form work complete all as specified and as directed. Note : Reinforcement will be measured and paid seperately.
11M&L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape as required including cranking, bending spirally for hooping for columns,hooking ends and binding with mild steel wire(annealed) not less than 0.9mm dia as in reinforcement bar complete all as specified and as directed.
12M & L for mild steel TMT bars 8 mm dia cut to length, bent to shape as required including cranking, bending spirally for hooping for columns,hooking ends and binding with mild steel wire(annealed) not less than 0.9mm dia as in reinforcement bar complete all as specified and as directed.
13Demolition of brick or stone masonry work built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed.
14M&L for brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:4 complete all as specified and as directed.
15M&L for brick work with subclass ‘B’ bricks, (locally available best quality) straight or curved on plan to any radius in half brick thick wall, built in cement mortar (1:4) complete all as specified and directed.
16Taking down cement plaster on walls, chajja surfaces, etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
17M & L for rendering 15 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed.
18M&L for 15mm thick rendering in cement mortar (1:4), in two layers, under coat of 10 mm thick & top of 5 mm thick, to other than fair faces of brick or concrete wall surfaces, top layer 5 mm thick mixed with water proofing compound @ 100Ml per bag(50Kg) of cement or as per manufacture's instructions, finished even and smooth without using extra cement complete all as specified and as directed. Note : Water proofing compound will be measured and paid separately as \\"Supply only\\".
19Supply only liquid water proofing compound complete all as specified and as directed.
20S&F DWCPE (SN8) pipes, nominal dia 150 mm laid in trenches or in floor for sewer network, fixed and jointed with integral socket or coupler and EPDM sealing ring (depending on pipe ends) as per manufacturer including dismantling of old drain pipe of any description instructions complete all as specified and as directed. Note: For item No 21 to 23, Make: (DWCPE Pipe): Supreme, Prince, Berlia
21S&F DWCPE (SN8) pipes, nominal dia 200 mm laid in trenches or in floor for sewer network, fixed and jointed with integral socket or coupler and EPDM sealing ring (depending on pipe ends) as per manufacturer including dismantling of old drain pipe of any description instructions complete all as specified and as directed.
22S&F DWCPE (SN8) pipes, nominal dia 300 mm laid in trenches or in floor for sewer network, fixed and jointed with integral socket or coupler and EPDM sealing ring (depending on pipe ends) as per manufacturer including dismantling of old drain pipe of any description instructions complete all as specified and as directed.
23M & L for concrete bed in cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) for drain pipes 150 mm bore including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed.
24M & L for concrete bed in cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) for drain pipes 200 mm bore including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed.
25M & L for concrete bed in cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) for drain pipes 300 mm bore including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed.
26S&F 110 mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints and laid in trenches or in floor/wall including dismantling of old drain pipe of any description instructions complete all as specified and as directed.
27S&F 75 mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints and laid in trenches or in floor/wall including dismantling of old drain pipe of any description instructions complete all as specified and as directed.Note : For item No 21, 22, 23, 26 & 27 Earth work shall be measured and paid separately under respective item.
28S & F 110 mm dia PVC (SWR) bends of any radius complete all as specified and as directed.
29S&F 110 mm dia PVC (SWR) bends with access door any radius complete all as specified and as directed
30S&F 75 mm dia PVC (SWR) bends with access door any radius complete all as specified and as directed
31S & F 75 mm dia PVC (SWR) bends of any radius complete all as specified and as directed.
32S&F 110mm dia PVC (SWR) junction single, (single T) equal or unequal provided complete all as specifiec and as directed.
33S&F 110mm dia PVC (SWR) junction single, (single T) equal or unequal provided with access door complete all as specifiec and as directed.
34S&F 75mm bore PVC (SWR) vent cowl complete all as specified and as directed.
35S&F irepairs, 75 mm dia PVC(SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed.
36M&L for Cutting into existing manholes for connecting new drains of 150 mm internal dia of pipe, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished, and reforming benching as required complete all as specified and as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57101009
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 47.76 Lakhs
LAST DATE 09-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for special Repair To Sewage Line Manholes And Safety Tanks From Otm-79 Of 19 Sikh Li At Barrackpore Under Ge Barrackpore
Basic Detail
Tender No 8290/E8
Bidding Type Tender
Location
City 24 Paraganas North
State West Bengal
Key Dates
Publish Date 19 Aug 2026
Submission Date 09 Sep 2026
Open Date 11 Sep 2026
Finance
Tender Value 47.76 Lakhs
Tender Fee 500
EMD 95520
Exemption Available
Document List
3ae6cd4e-7e6e-4ef6-8893-261fb8bedb9e.html
BOQ_879962.xls
Tenderdoc_8290.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Sep 11, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 20 days

Tender Documents

Download All (ZIP) ↓
html

3ae6cd4e-7e6e-4ef6-8893-261fb8bedb9e.html

xls

BOQ_879962.xls

pdf

Tenderdoc_8290.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender