Tender For Repair And Maintenance Of External Water Supply Distribution Lines Valve Set At Zone-Ii Under Ge Brichgunj, Sri Vijay Puram
Tender Value
45 Lakhs
Estimated cost
Bid Submission
10 Sep 2026
18 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
South Andamans → Andaman And Nicobar Islands
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair And Maintenance Of External Water Supply Distribution Lines Valve Set At Zone-Ii Under Ge Brichgunj, Sri Vijay Puram
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.5 m wide and n.exc. 1.5 m deep and getting out for taking out or laying of pipes / cable of any size in soft/loose of soil complete all as specified and as directed. |
| 2 | All as per Item Ser No.1.00 but hard /dense soil complete all as specified and as directed. |
| 3 | Returning filling in including spreading leveling watering and well ramming in layers n.exc. 25cm in each layer, any type of soil complete all as specified and as directed. |
| 4 | Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed. |
| 5 | Supply and laying in trenches or on pedestal wherever required ,jointing ,testing and commissioning, of HDPE pipes,ISI marked of Pressure rating 6 kgf/cm2 of 50 mm outer dia including taking down of existing unserviceable pipes complete all as specified and as directed. |
| 6 | All as per Item Ser No.4.00 but 40 mm dia, complete all as specified and as directed. |
| 7 | Supply and laying in trenches or on pedestal wherever required ,jointing ,testing and commissioning of HDPE pipes PN 10 of 65 mm bore, ISI marked including taking down of existing unserviceable pipes complete all as specified and as directed. |
| 8 | All as per Item Ser No.5.00 but 75 mm bore complete all as specified and as directed. |
| 9 | All as per Item Ser No.5.00 but 100 mm bore complete all as specified and as directed. |
| 10 | All as per Item Ser No.5.00 but 150 mm bore complete all as specified and as directed. |
| 11 | Supply, laying in trenches, connect, joint, test and commission of 250 mm dia Ductile Iron Pressure Pipes, Centrifugally Cast [Spun], Class \\"K-9\\" with Socket and Spigot ends conforming to IS-8329 in standard lengths suitable for Push-On Rubber Gasket Jointing with inside mortar lining and black bitumen external coating complete including taking down of existing unserviceable pipes complete all as specified and as directed. |
| 12 | All as per Item Ser No.6.00 but 200 mm dia complete all as specified and as directed. |
| 13 | All as per Item Ser No.6.00 but 150 mm dia complete all as specified and as directed. |
| 14 | All as per Item Ser No.6.00 but 100 mm dia complete all as specified and as directed. |
| 15 | All as per Item Ser No.6.00 but 80 mm dia complete all as specified and as directed. |
| 16 | All as per Item Ser No.6.00 but 300 mm dia complete all as specified and as directed. |
| 17 | Material and labour for Cutting Road as required for Jointing / Laying / taking down GI / CI / DI Pipeline and making good disturbed as per site surface with 20/40mm graded stone aggregate and bitumen after repair work complete all as specified and as directed. |
| 18 | Material and labour for detecting leakage in HDPE 200/160 mm dia of pipe in any location, any depth and repairing and arresting leakage by Jointing of pipes, Flanged Clamps, Nuts, Washers & Bolts and necessary excavation etc. complete all as specified and as directed. Note: Rate deemed to be inclusive of rate of all fittings required at site and jointing of pipes using machinery & rate of HDPE pipe shall be measured under relavant item. |
| 19 | All as per Item Ser Item No.8.00 here-in-before but of size 110/80 mm dia complete all as specified and as directed. |
| 20 | All as per Item Ser Item No.8.00 here-in-before but of size 65/50 mm dia complete all as specified and as directed. |
| 21 | M&L for detecting leakage in CI/DI pipe by cocking and inserting spurn yarn and Run lead joint, making good/ leakless the joint for pipes of 80 mm dia and necessary excavation complete all as specified and as directed :- Note: Rate deemed to be inclusive of rate of all fittings required at site and jointing of pipes. |
| 22 | All as per Item Ser No.9.00 but 100 mm dia complete all as specified and as directed. |
| 23 | All as per Item Ser No.9.00 but 150 mm dia complete all as specified and as directed. |
| 24 | All as per Item Ser No.9.00 but 200 mm dia complete all as specified and as directed. |
| 25 | All as per Item Ser No.9.00 but 250 mm dia complete all as specified and as directed. |
| 26 | All as per Item Ser No.9.00 but 300 mm dia complete all as specified and as directed. |
| 27 | Material and labour for detecting leakage in GI Water Supply GI Lines of size 20mm dia to 25 mm dia by necessary excavation, returning /filling as required, tightening of loose joints of union ,elbow, socket nipple as per site requirement including replacement of all fittings such as GI union ,socket, nipple, any other jointing material etc as required at site complete all as specfied and as directed. |
| 28 | All as per Item Ser No.10.00 but size 40 mm bore complete all as specified and as directed. |
| 29 | All as per Item Ser No.10.00 but size 50 mm bore complete all as specified and as directed. |
| 30 | All as per Item Ser No.10.00 but size 80 mm bore complete all as specified and as directed. |
| 31 | All as per Item Ser No.10.00 but size 100 mm bore complete all as specified and as directed. |
| 32 | Material and labour for detecting leakage in CPVC/UPVC Pipes Lines of size 20mm dia to 25 mm dia by necessary excavation, returning /filling as required, tightening of loose joints of union ,elbow, socket nipple as per site requirement including replacement of all fittings such as CPVC/UPVC union ,socket, nipple, any other jointing material etc as required at site complete all as specified and as directed. |
| 33 | All as per Item Ser No.11.00 but size 40 mm bore complete all as specified and as directed. |
| 34 | All as per Item Ser No.11.00 but size 50 mm bore complete all as specified and as directed. |
| 35 | Excavation and earth work in mud/hard soil etc by using machinary/labour to any length to attend pipe line breakdown as per site conditions and forming bund with excavated soil to avoid water entering into the working area including pumping/bailing out water by using portable diesel engine driven pump set including the following complete all as specified and as directed :- (i) Cutting of unserviceable CI/DI pipe of size 300 mm dia after thorough inspection for the damage including bailing out water using portable pump set. (ii) Taking out damaged/ unserviceable pipe after removing from rubber tyton joint/burning out lead joints at both ends & replacing new 300 mm dia DI pipe line in lieu of existing in to trenches using machinary / labour as required complete all as specified and as directed by Engineer-in-Charge. (iii) Transportation of DI pipe / fittings of size 300 mm dia to work site and cutting the pipe to required length to suit site conditions.(iv) Jointing pipe by using rubber tyton rings 300mm dia to the corresponding socket and spigot ends of the existing pipe line after aligning the pipe line as per site condition, inserting the CI collar of size 300dia, complete all as specified and as directed by Engineer-in-Charge. (v) Making run lead joints in CI collar 300 mm dia or in any other specials of any size and any type, caulking of joints and testing for leakages if any, complete all as specified and as directed by Engineer-in-Charge. (vi) Returning filling in including removal of surplus mud/excavated materials with the help of earthmoving machinery (Hitachi), complete all as specified and as directed by Engineer-in-Charge. |
| 36 | All as per Item Ser Item No.12.00 here-in-before but of size 250/200 mm dia complete all as specified and as directed. |
| 37 | S & F in Replacement of Sluice Valve, Cast Iron body, Stainless Steel Spindle, Gun Metal Rings including Wheel for operation, Flanged and Drilled, 80 mm bore of pipe, confirming to IS - 14846, Class PN -1.6, Long Body type including all Joints with Rubber Gasket and Jointing Materials, Bolts, Nuts, Washer complete all as specified and as directed. |
| 38 | All as per Item Ser No.13.00 here-in-before, but 100mm bore, complete all as specified and as directed. |
| 39 | All as per Item Ser No.13.00 here-in-before, but 150mm bore, complete all as specified and as directed. |
| 40 | All as per Item Ser No.13.00 here-in-before, but 200mm bore, complete all as specified and as directed. |
| 41 | All as per Item Ser No.13.00 here-in-before, but 250mm bore, complete all as specified and as directed. |
| 42 | S&F in Replacement of CPVC pipes 20mm outer dia SDR 13.5 & Plain CPVC SDR 13.5 grade with all types of fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc as required at site, fittings on walls/ceiling or laying in floors complete all as specified and as directed . |
| 43 | All as per Item Ser Item No.14.00 here-in-before but of 25mm CPVC pipes, complete all as specified and as directed. |
| 44 | All as per Item Ser Item No.14.00 here-in-before but of 40 mm CPVC pipes, complete all as specified and as directed. |
| 45 | All as per Item Ser Item No.14.00 here-in-before but of 50 mm CPVC pipes, complete all as specified and as directed. |
| 46 | Material and labour for opening of unserviceable sluice valves, cleaning the serviceable parts, adjusting of moving parts , greasing , re-assembling of valve and fixing to the desired position with and including replacement of rubber gaskets, nuts ,bolts, washers , gland packing,Brass Checknuts and SS Spindle suitable for following 80 mm bore dia of sluice valve complete all as specified and as directed. |
| 47 | All as per Item Ser Item No.15.00 here-in-before but of size 100 mm dia, complete all as specified and as directed. |
| 48 | All as per Item Ser Item No.15.00 here-in-before but of size 150 mm dia, complete all as specified and as directed. |
| 49 | All as per Item Ser Item No.15.00 here-in-before but of size 200 mm dia, complete all as specified and as directed. |
| 50 | All as per Item Ser Item No.15.00 here-in-before but of size 250 mm dia, complete all as specified and as directed. |
| 51 | All as per Item Ser Item No.15.00 here-in-before but of size 300 mm dia, complete all as specified and as directed. |
| 52 | M&L for Repairs to dismantling and taking up CI Foot Valve, 200mm dia at various Pump Houses, opening, cleaning with wire brush, removing deposited scales / foreign materials, rubbing with emery paper and replacing unserviceable Gasket, Bolts, Nuts, Washers and Worn-out Parts etc, and refixing in original position complete all as specified and as directed. |
| 53 | All as per Item Ser No.16.00 here-in-before, but of size 150mm dia, complete all as specified and as directed. |
| 54 | All as per Item Ser No.16.00 here-in-before, but of size 100mm dia, complete all as specified and as directed. |
| 55 | All as per Item Ser No.16.00 here-in-before, but of size 80mm dia, complete all as specified and as directed. |
| 56 | S&F in Replacement of butterfly valve heavy duty flanged ends drilled ISI marked confirming to IS: 14846 suitable for 200 mm dia pipe including nuts, bolts and jointing with jointing materials complete all as specified and as directed. |
| 57 | All as per Item Ser No.17.00 here-in-before, but of size 150mm dia, complete all as specified and as directed. |
| 58 | All as per Item Ser No.17.00 here-in-before, but of size 100mm dia, complete all as specified and as directed. |
| 59 | All as per Item Ser No.17.00 here-in-before, but of size 80mm dia, complete all as specified and as directed. |
| 60 | All as per Item Ser No.17.00 here-in-before, but of size 65 mm dia, complete all as specified and as directed. |
| 61 | All as per Item Ser No.17.00 here-in-before, but of size 50 mm dia, complete all as specified and as directed. |
| 62 | S&F in Repalacement of non return valve with flanged ends of any pattern with bypass arrangement and ISI marked including jointing materials and necessary joints and nut bolts with washer for flanged ends of size 200 mm complete all as specified and as directed. |
| 63 | All as per Item Ser No.18.00 here-in-before, but of size 150 mm dia, complete all as specified and as directed. |
| 64 | All as per Item Ser No.18.00 here-in-before, but of size 100 mm dia, complete all as specified and as directed. |
| 65 | All as per Item Ser No.18.00 here-in-before, but of size 80 mm dia, complete all as specified and as directed. |
| 66 | All as per Item Ser No.18.00 here-in-before, but of size 65 mm dia, complete all as specified and as directed. |
| 67 | All as per Item Ser No.18.00 here-in-before, but of size 50 mm dia, complete all as specified and as directed. |
| 68 | M&L for Construction of valve chamber of size 600mmx600mm x600mm internal size suitable for sluice valve with PCC 1:3:6 type C2, (using 40mm graded stone aggregate) as in foundation, one hollow block masonry wall in cement mortar 1:4, 40mm thick PCC 1:2:4, type B1, (using 20mm graded stone aggregate) as in coping, rendering in cement mortar 1:4, 15mm thick including provision of mild steel sheet cover of 3mm thick on 40cmx40cmx6 mm angle iron frame work emmbedded in concrete with suitable hinges and locking arrangements including two coats of black synthetic enamel black paint over a coat of red oxide zinc chrome primer to steel surfaces and including necessary excavation earth work on any type of soil etc. including removal of surplus soil and rubbish not exceeding 50m distance, including demolition of old valve chambers complete all as specified and as directed. |
| 69 | All as per Item Ser No.19.00 here-in-before but of internal size 900 x 900x 900mm, complete all as specified and as directed. |
| 70 | All as per Item Ser No.19.00 here-in-before but of internal size 1200 x 1200x 1200mm , complete all as specified and as directed. |
| 71 | M & L for Plain cement concrete 1:3:6, type C1, (using 20mm graded stone aggregate) as in foundation, mass concrete etc (including necessary form work) complete all as specified and as directed. |
| 72 | S&F in Replacement Gun metal gate valve with iron wheel head screwed both ends for pipe of size 20 mm complete all as specified and as directed. |
| 73 | All as per Item Ser No.21.00 here-in-before but of size 25 mm, complete all as specified and as directed. |
| 74 | All as per Item Ser No.21.00 here-in-before but of size 40 mm, complete all as specified and as directed. |
| 75 | All as per Item Ser No.21.00 here-in-before but of size 50 mm, complete all as specified and as directed. |
| 76 | Supplying, fixing and testing of Cast Iron, heavy duty, Specials of any size, radius and length confirming to IS - 1538 Part - I to XXIII: 1976 such as bends [any type, radius and angle], tapers any type [straight, bend, increasing, decreasing or double socket etc], sockets, tail pieces, connecting pieces, tee pieces, single branch, \\"Y\\" junction, double branch, cross, [all sockets or socket and spigot or Flanged], collars, caps and plugs, ( required for shape as per site ) adopters etc suitable for CI Spigot and Socket or Flanged pressure pipes complete all as specified and as directed. |
| 77 | All as per Item Ser No.22.00 here in before but DI fittings of any size complete all as specified and as directed. |
| 78 | M&L for Repairs to Air Release Valve, of 80mm bore of pipe and refixing the same after replacing the unserviceable HDPE Float, Nuts, Bolts and jointing materials complete all as specified and as directed. |
| 79 | S&F in Replacement of Induction mono block pumpset complete with head range 18 to 26 mtr, disch 1.5 LPS, single phase, 2700 rpm (capacity not less than 1HP) alongwith with suitable starter and complete all as specified and as directed. |
| 80 | S& F in Replacement of steel water tubes medium grade (ISI marked) galvanised with all fittings and fixed to walls or laid on floor or in ceilings of size 20 mm bore pipe including taking out of old pipelines complete all as specified and as directed. |
| 81 | All as per Item Ser No.25.00 but of size 25 mm dia, complete all as specified and as directed. |
| 82 | All as per Item Ser No.25.00 but of size 40 mm dia, complete all as specified and as directed. |
| 83 | All as per Item Ser No.25.00 but of size 50 mm dia , complete all as specified and as directed. |
| 84 | All as per Item Ser No.25.00 but of size 80 mm dia , complete all as specified and as directed. |
| 85 | S&F in Replacement of rotational moulded polyethylene water storage tanks with tank cover (top), tank nipple and fixed in position complete after dismantling and taking down the existing unserviceable PVC water tank of size 300 ltrs capacity from terrace complete all as specified and as directed. |
| 86 | All as per Item Ser Item No.26.00 here-in-before but of size 500 ltrs capacity, complete all as specified and as directed. |
| 87 | All as per Item Ser Item No.26.00 here-in-before but but of size 1000 ltrs capacity, complete all as specified and as directed. |
| 88 | S&F in Replacement of 20mm dia ball valves, Union Type, high pressure, CPVC polythene gate and fly-nut complete all as specified and as directed. |
| 89 | All as per Item Ser No.27.00 but of size 25mm bore, complete all as specified and as directed. |
| 90 | All as per Item Ser No.27.00 but of size 40mm bore, complete all as specified and as directed. |
| 91 | All as per Item Ser No.27.00 but of size 50mm bore, complete all as specified and as directed. NOTES :-1. The contractor or his authorised representative shall report to water supply complaint cell /JE E/M or Engineer-in-Charge at 0900 hours daily on all working days to receive order/instructions of the work or regular complaints. A register shall be maintained to record all orders & instructions and their complaints and is to be signed by the contractor/his representative and the JE EM/ Engr-in -Charge.2. In case the contractor fails to attend/rectify the defects within the above time limit, penalty will the imposed as Rs 500/- per day in case of complaints/jobs. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysSep 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender