Defence Statutory Bodies & Commissions/Committees Closing in 18 days TDR #57100997

Tender For Addition/Alteration Of False Ceiling And Light Fitting Work At The Ground Floor Of Pcda (O) Office Under Age B/R-I Of Ge (S) Pune

Issued by Statutory Bodies & Commissions/Committees · Pune, Maharashtra
Tender Value
40.05 Lakhs
Estimated cost
Bid Submission
09 Sep 2026
18 days left
EMD
80100
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Addition/Alteration Of False Ceiling And Light Fitting Work At The Ground Floor Of Pcda (O) Office Under Age B/R-I Of Ge (S) Pune

BOQ

Name of Work:- ADDITION/ALTERATION OF FALSE CEILING AND LIGHT FITTING WORK AT THE GROUND FLOOR OF PCDA (O) OFFICE UNDER AGE B/R-I OF GE (S) PUNE
Sl. No. Item Description
1M&L for dismantling ceiling and wall boards with frame (fibre, pulp, insulation, etc) or insulation boards/ slab / blankets, any thickness, including cover fillets complete all as specified and directed.
2M&L for false ceiling with 9 to 9.5mm thick glass fibre reinforced Gypsum ceiling tiles of size 595 x 595 mm prima fine fissured micro look white coloured laid over including grid work 600 x0600mm using GI powder coated `T` section grid as Main `T` 38 x25mm, cross `T` 25 x 25 mm and wall angle 25 x 25mm grid and 4mm dia GI suspension wire etc complete all as specified and directed.
3Supply and fix 6mm thick PVC hollow wall paneling plain/coloured/printed fixed with screws to wall and corner on pvc battens, edges of panels be sealed with appropriate arrangement, corner with silicone sealant or specialized construction adhesive match to colour and pattern as approved Complete all as specified and as directed.
4Taking down carefully the existing unserviceable batten/conduit/concealed type aluminium point wiring for light, fan, socket 5 Amps and15 Amps complete removing the same including fittings/fixtures and making good the disturbed surfaces of walls, floors, ceiling etc.
5Taking down unserviceable main switch/DB, Teak wood boards etc
6Taking down submain wiring of any size complete all as directed.
7M&L point wiring surface type with 1.5 Sqmm (nominal area), PVC insulated, multistranded, single core unsheathed, copper conductor cable (FRLS) drawn through and including PVC Conduits with all accessories complete fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) PVC insulated, unsheathed, stranded, single core, copper cable (FRLS) green in colour as earth continuity wire connecting to common earth point including 1.6 mm thick MS/GI Modular Metal flush box of suitable size for mounting switches, sockets, regulators etc complete for one light/bell point /ceiling fan/ exhaust fan controlled by one ,one way switches complete all as specified and as directed by Engineer-in charge.
8All as per item No 07 above but for one 3/2 Pin 5 Amp socket out let point on the independent board.
9All as per item No 07 above but for one socket outlet 3/2 pin, 5 Amp, point on the same board with other switches.
10All as per item no 07 here-in-before but with cable 2.5 sqmm including 2.5 sqmm cable as earth wire for 15/16 amp socket point.
11M&L point wiring with 1.5 Sqmm (nominal area), PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point including 1.6 mm thick MS/GI Modular Metal flush box of suitable size for mounting switches, sockets, regulators etc complete for one light/bell point /ceiling fan/ exhaust fan controlled by one ,one way switches complete all as specified and as directed by Engineer-in charge.
12All as per item No 11 above but for one call bell point controlled by one bell switch.
13All as per item No 11 above but for one ceiling fan point controlled by one switch.
14All as per item No 11 above but for one light point controlled by two 2-way switches.
15All as per item No 11 here-in-before but one 5 Amps 3/5 pin socket outlet on the same board with other switch.
16All as per item No 11 here-in-before but one 5 Amps 3/5 pin socket outlet on independent board.
17All as per item No. 11 above but wiring with 2.5 sqmm copper cables with 2.5 Sqmm copper cable as continuous earth wire for one 5/15 Amps switch socket outlet on independent board.
18All as per item No. 11 here-in-before but wiring with 4 sqmm copper cables with 4 Sqmm copper cable as continuous earth wire for one 5/15 Amps switch socket outlet on indipendent board.
19Supply and fix single pole and neutral enclosures with a two pin and earth plug and socket complete with one double pole MCB 10 A ,240 V complete all as specified and as directed.
20S&F Modular switch 1 way 6A, 1 module complete all as specified and directed.
21S&F Modular switch 2 way 6A, 1 module complete all as specified and directed.
22S&F Modular switch 1 way 16A, 1 module complete all as specified and directed.
23S&F Socket, 6A - 2/3 pin combined 2 module, complete all as specified and directed.
24S&F Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and directed.
25S&F modular type fan regulator 120 Watts , 2 module , complete all as specified and directed.
26S&F modular type bell push switch , 1 module , complete all as specified and directed.
27S & F modular white cover plate with frame, 2 module complete all as specified and as directed.
28All as per item No 27 above but 3 module
29All as per item No 27 above but 6 module
30All as per item No 27 above but 8 module
31Supply and fix ceiling rose surface bakelite 65x50 mm two to three terminals complete all as specified and directed.
32Supply and fix call bell AC, 230 volts single pole complete all as specified and directed.
33S&F in repair MCB single pole, 240 volts 6 to 32 Amps, 'C' curve complete all as specified and directed.
34S&F in repair v MCB single pole and neutral 06 to 32 Amps, 240 Volts, 'C' curve complete all as specified and directed.
35S & F in repair MCB TPN 40 to 63 Amps, 415 Volts 'C' curve complete all as specified and directed.
36S&F sheet metal enclosure, (for DB's when MCBs to be used), flushed in wall single pole and neutral Double door, 8 way, 240 Volts with PVC MCB blanking plates, stove enamelled, dust and vermin proof suitable for incorporation of MCB's and isolators etc complete all as specified and as directed.
37Supply and fixing load line distribution board TPN vertical, 4 way double door type, fixed on wall semi flush with incoming MCCB 4 poles 125 Amps, 10 KA, busbars , neutral link, blanking plates with IP 43 protection and door earthing complete with all accessories all as specified and as directed by Engineer-in-Charge.Make : Indoasian Cat No 811888 or equivalent in C&S/ Havells//Legrand/ABB/SchneiderNote: Outgoing MCBs shall be measured and paid separately.
38Removing the existing ceiling fans (before carrying out ceiling repair work) and keeping them in safe custody and refixing at the same or an locaton after proper cleaning and with new 'U'clamp set with nut bolt washer, split pin and rubber bush, down rod if required and new capacitor 2.5 mfd complete and connecting with PVC cable with stranded copper conductor of size 0.75 Sqmm, complete all as specified and directed. Note: The rate quoted deemed to be included the cost of U clamp set, down rod, capacitor and PVC copper cable for connection.
39Supplying and fixing of ceiling fan , five star rating, (BLDC) white/ivory 1200 mm sweep, 3 wings suitable for operating on AC 220/230 volts single phase, 50hz supply with down road complete, including necessary PVC insulated flexible wire 3 core for connecting from ceiling rose to connector etc complete all as specified and as directed.
40S&F mild steel fan hook / U clamp made out of mild steel flat iron of suitable section & size bend to required shape including necessary welding as per site requirements suitable for hanging the ceiling fans with fastener / bolts, washers and nuts etc complete all as directed by Engr-in-Charge
41M&L sub main wiring concealed type with two runs of single core, PVC insulated, unsheathed multi standard copper conductor cable of size 6 Sqmm, 1100 volts grade (FRLS) and one run o f 6 Sqmm PVC insulated multi stranded copper conductor for earth continuity conductor drawn through and including suitable size ISI marked rigid PVC conduit with all necessary accessories such as bends, tees, junction boxes, elbows complete all as specified and as directed. (Note :- Two runs of 6 Sqmm cable, one run of 6 Sqmm continuity earth wire and one run of PVC conduit with all necessary accessories will be measured as one length).
42M&L sub main wiring surface type/conealed type as required at site with four runs of single core, PVC insulated, unsheathed multi standard copper conductor cable of size 10 Sqmm, 1100 volts grade (FRLS) and one run of 10 Sqmm PVC insulated multi stranded copper conductor for earth continuity conductor drawn through and including suitable size ISI marked rigid PVC casing and capping with all necessary accessories complete all as specified and as directed. (Note :- Four runs of 10 Sqmm cable, one run of 10 Sqmm continuity earth wire and one run of PVC conduit with all necessary accessories will be measured as one length).
43Supply and fix recess mounted low glare LED panellight 2'X2' size 36 watt white/warm white for armstrong/grid ceiling or similar ceiling mounting system complete prewired using 1.5 Sqmm FRLS PVC insulated (Unsheathed) 3 core copper conductor cable, 1100V grade including taking down old complete all as specified and directed.
44S & F LED batten suitble for indoor application 20 W, 4' length , wall mounted with polycarbonate housing, end cap made of ABS plastic of white colour finish and high efficiency translucence (HET) diffuser and integral electronic driver including two point surface mounting on wall/ ceiling and connecting up with twin core twisted flexible copper conductor cable of suitable size including taking down old complete all as specified and as directed by Engr-in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57100997
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 40.05 Lakhs
LAST DATE 09-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Addition/Alteration Of False Ceiling And Light Fitting Work At The Ground Floor Of Pcda (O) Office Under Age B/R-I Of Ge (S) Pune
Basic Detail
Tender No 8889 GE SOUTH PUNE
Bidding Type Tender
Location
City Pune
State Maharashtra
Key Dates
Publish Date 19 Aug 2026
Submission Date 09 Sep 2026
Open Date 16 Sep 2026
Finance
Tender Value 40.05 Lakhs
Tender Fee 500
EMD 80100
Exemption Available
Document List
4e0de7ef-f5ac-421e-b0ad-b42b4d13b85e.html
8889TenderDocs.pdf
BOQ_879760.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Sep 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 25 days

Tender Documents

Download All (ZIP) ↓
html

4e0de7ef-f5ac-421e-b0ad-b42b4d13b85e.html

pdf

8889TenderDocs.pdf

xls

BOQ_879760.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders