Tender for Repair And Maintenance Of Lt Ug Cable ,Earthing Systems, Lt Panels And Misc Items At Mysore Under Age (I) Af Chimney Hills
BOQ
| Sl. No. | Item Description |
| 1 | Supply and lay LT under ground cable XLPE insulated armoured heavy duty 1100V grade with multistranded/solid aluminium conductor confirming to relevant IS in trenches, ducts, through pipes fixed to wall etc all as directed including cable gland, terminal socket and connecting up of size 70 sqmm 3.5 core including taking downe of old U/S cable |
| 2 | All as per item ser No 1 above but of size 50 sqmm 3.5 core |
| 3 | All as per item ser No 1 above but of size 35 sqmm 3.5 core |
| 4 | All as per item ser No 1 above but of size 25 sqmm 4 core |
| 5 | All as per item ser No 1 above but of size 16 sqmm 4 core |
| 6 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m deep and getting out in hard/dense soil for laying/repair of cable. |
| 7 | Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25cm thick. |
| 8 | Removing excavated materials to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point. |
| 9 | Supply and laying reiforced precast cable cover class LV, Type Im flat , size 250mmX150 mmX40mm |
| 10 | M&L for sand cushioning in trenches spreading and consolidation 8cm thick before laying the cable & 15 cm of sand after laying the cable complete all as specified |
| 11 | Supply and lay in repair GI tubing light grade, 80mm dia in trenches for road crossing/laid in floors etc |
| 12 | All as per item ser No 11 above but 50mm dia |
| 13 | M&L for Dehydration and Filtering the transformer oil having the dielectric strength below 40KV and testing of transformer oil after filtration as per IS-335-1972 and removing the moisture contents in the transformer cores/winding as directed by Engr-in-Charge. |
| 14 | Topping up or replacement of transformer oil with di-electric strength not less than 60 KV in to the conservator tank/ body tank of the transforme etc at various locations complete all as specified and as directed. |
| 15 | M&L for replacement of silica gel breather assembly for distribution transformers of 200 KVA to 315 KVA capacity including dismantling old one all as specified and as directed |
| 16 | S&F in repair Danger notice plate of 1.6mm thick mild steel sheet with vitreouse name lled with letter figures and conventional skull and bones insignal red colour and fixed with MS clamps, bolts and nuts of approved size for HT, 25 x 20 cm all as specified and directed. |
| 17 | M&L in repair Earth continuity conductor or main earthing lead fixed to Panel board /Transformer on recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicatedsituation for loop earthing etc. as required 32 X 6 mm galvanised iron all as specified and directed. |
| 18 | M&L in repair Earth continuity conductor or main earthing lead fixed to Panel board/ Transformer on recess or chases or buried inground or drawn in conduit/pipe or fixed to poles or any other indicatedsituation for loop earthing etc. as required 20X 3 mm copperstrip all as specified and directed. |
| 19 | M&L in repair earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground earth pit not less than 2.25m below ground level with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized iron strip 32x6mm as a earthing lead by means of bolts, nuts, checks nuts, washers etc made of galvanized of steel, earth strip including and protected by galvanized iron pipe(light grade) 40 mm dia from plate to Panel Board, galvanized iron pipe light grade 20mm dia bore and funnel watering including test point necessary excavation ,earth work, concrete pit M-10, CI cover, frame and funnel,Charcoal dust,Salt all as specified in plate No 3 of SSR-1991(part-1) complete all as specified and as directed. |
| 20 | All as per item No 19 Above but using copper plate 60X 60 cm Xb 3.15 mm copper plate and 20X 3mm copper strip |
| 21 | Supply and fix in repair MCCB, four pole, 400 Amps with thermal magnetic release with range 320 - 400 Amp,, having breaking capacity 36 KA complete all as specified and directed. |
| 22 | Supply and fix in repair MCCB, four pole, 250 Amps with thermal magnetic release with range 200 - 250 Amp,, having breaking capacity 36 KA complete all as specified and directed. Make : L&T / Havells / Indo Asian |
| 23 | Supply and fix in repair MCCB, for pole, 200 Amps with thermal magnetic release with range 160 - 200 Amp,, having breaking capacity 36 KA complete all as specified and directed. Make : L&T / Havells / Indo Asian |
| 24 | Supply and fix in repair MCCB, three pole, 125 Amps with thermal magnetic release with range 100 - 125 Amp,, having breaking capacity 16 KA complete all as specified and directed. Make : L&T / Havells / Indo Asian |
| 25 | Supplying and making straight through joint with castresin compound including ferrules and other jointingmaterials for following size of PVC insulated and PVCsheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required, for Cable size 35 Sq.mm X 3.5 core |
| 26 | Supplying and making straight through joint with castresin compound including ferrules and other jointingmaterials for following size of PVC insulated and PVCsheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required, for Cable size 50 Sq.mm X 3.5 core |
| 27 | Supplying and making straight through joint with castresin compound including ferrules and other jointingmaterials for following size of PVC insulated and PVCsheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required, for Cable size 185 Sq.mm X 3.5 core |
| 28 | M&L Concrete cutting gound floor and paving not exceeding 15 cm thickness below and above ground level for road cutting to lay pipe. |
| 29 | M&L for cement concrete type B2 1:2:4 (40m graded aggregate) upto 100mm thickness for making good to areas of concrete road cutting Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 09, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysSep 16, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender