Defence Statutory Bodies & Commissions/Committees Closing in 16 days TDR #57100994

Tender For Repair And Maintenance Of Lt Ug Cable ,Earthing Systems, Lt Panels And Misc Items At Mysore Under Age (I) Af Chimney Hills

Issued by Statutory Bodies & Commissions/Committees · Mysuru, Karnataka
Tender Value
9 Lakhs
Estimated cost
Bid Submission
09 Sep 2026
16 days left
EMD
18000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Mysuru → Karnataka
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair And Maintenance Of Lt Ug Cable ,Earthing Systems, Lt Panels And Misc Items At Mysore Under Age (I) Af Chimney Hills

BOQ

Name of Work:- Repair and Maintenance of LT UG Cable ,Earthing systems, LT Panels and misc items at Mysore under AGE (I) AF Chimney Hills
Sl. No. Item Description
1Supply and lay LT under ground cable XLPE insulated armoured heavy duty 1100V grade with multistranded/solid aluminium conductor confirming to relevant IS in trenches, ducts, through pipes fixed to wall etc all as directed including cable gland, terminal socket and connecting up of size 70 sqmm 3.5 core including taking downe of old U/S cable
2All as per item ser No 1 above but of size 50 sqmm 3.5 core
3All as per item ser No 1 above but of size 35 sqmm 3.5 core
4All as per item ser No 1 above but of size 25 sqmm 4 core
5All as per item ser No 1 above but of size 16 sqmm 4 core
6Excavation in trenches n.exc 1.5m wide and n.exc 1.5m deep and getting out in hard/dense soil for laying/repair of cable.
7Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25cm thick.
8Removing excavated materials to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point.
9Supply and laying reiforced precast cable cover class LV, Type Im flat , size 250mmX150 mmX40mm
10M&L for sand cushioning in trenches spreading and consolidation 8cm thick before laying the cable & 15 cm of sand after laying the cable complete all as specified
11Supply and lay in repair GI tubing light grade, 80mm dia in trenches for road crossing/laid in floors etc
12All as per item ser No 11 above but 50mm dia
13M&L for Dehydration and Filtering the transformer oil having the dielectric strength below 40KV and testing of transformer oil after filtration as per IS-335-1972 and removing the moisture contents in the transformer cores/winding as directed by Engr-in-Charge.
14Topping up or replacement of transformer oil with di-electric strength not less than 60 KV in to the conservator tank/ body tank of the transforme etc at various locations complete all as specified and as directed.
15M&L for replacement of silica gel breather assembly for distribution transformers of 200 KVA to 315 KVA capacity including dismantling old one all as specified and as directed
16S&F in repair Danger notice plate of 1.6mm thick mild steel sheet with vitreouse name lled with letter figures and conventional skull and bones insignal red colour and fixed with MS clamps, bolts and nuts of approved size for HT, 25 x 20 cm all as specified and directed.
17M&L in repair Earth continuity conductor or main earthing lead fixed to Panel board /Transformer on recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicatedsituation for loop earthing etc. as required 32 X 6 mm galvanised iron all as specified and directed.
18M&L in repair Earth continuity conductor or main earthing lead fixed to Panel board/ Transformer on recess or chases or buried inground or drawn in conduit/pipe or fixed to poles or any other indicatedsituation for loop earthing etc. as required 20X 3 mm copperstrip all as specified and directed.
19M&L in repair earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground earth pit not less than 2.25m below ground level with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized iron strip 32x6mm as a earthing lead by means of bolts, nuts, checks nuts, washers etc made of galvanized of steel, earth strip including and protected by galvanized iron pipe(light grade) 40 mm dia from plate to Panel Board, galvanized iron pipe light grade 20mm dia bore and funnel watering including test point necessary excavation ,earth work, concrete pit M-10, CI cover, frame and funnel,Charcoal dust,Salt all as specified in plate No 3 of SSR-1991(part-1) complete all as specified and as directed.
20All as per item No 19 Above but using copper plate 60X 60 cm Xb 3.15 mm copper plate and 20X 3mm copper strip
21Supply and fix in repair MCCB, four pole, 400 Amps with thermal magnetic release with range 320 - 400 Amp,, having breaking capacity 36 KA complete all as specified and directed.
22Supply and fix in repair MCCB, four pole, 250 Amps with thermal magnetic release with range 200 - 250 Amp,, having breaking capacity 36 KA complete all as specified and directed. Make : L&T / Havells / Indo Asian
23Supply and fix in repair MCCB, for pole, 200 Amps with thermal magnetic release with range 160 - 200 Amp,, having breaking capacity 36 KA complete all as specified and directed. Make : L&T / Havells / Indo Asian
24Supply and fix in repair MCCB, three pole, 125 Amps with thermal magnetic release with range 100 - 125 Amp,, having breaking capacity 16 KA complete all as specified and directed. Make : L&T / Havells / Indo Asian
25Supplying and making straight through joint with castresin compound including ferrules and other jointingmaterials for following size of PVC insulated and PVCsheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required, for Cable size 35 Sq.mm X 3.5 core
26Supplying and making straight through joint with castresin compound including ferrules and other jointingmaterials for following size of PVC insulated and PVCsheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required, for Cable size 50 Sq.mm X 3.5 core
27Supplying and making straight through joint with castresin compound including ferrules and other jointingmaterials for following size of PVC insulated and PVCsheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required, for Cable size 185 Sq.mm X 3.5 core
28M&L Concrete cutting gound floor and paving not exceeding 15 cm thickness below and above ground level for road cutting to lay pipe.
29M&L for cement concrete type B2 1:2:4 (40m graded aggregate) upto 100mm thickness for making good to areas of concrete road cutting Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57100994
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 9 Lakhs
LAST DATE 09-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair And Maintenance Of Lt Ug Cable ,Earthing Systems, Lt Panels And Misc Items At Mysore Under Age (I) Af Chimney Hills
Basic Detail
Tender No 8989/E8
Bidding Type Tender
Location
City Mysuru
State Karnataka
Key Dates
Publish Date 19 Aug 2026
Submission Date 09 Sep 2026
Open Date 16 Sep 2026
Finance
Tender Value 9 Lakhs
Tender Fee 500
EMD 18000
Exemption Available
Document List
6e248077-e3d4-45bd-ac37-613a9a737946.html
8989Tender.pdf
BOQ_879865.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Sep 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 23 days

Tender Documents

Download All (ZIP) ↓
html

6e248077-e3d4-45bd-ac37-613a9a737946.html

pdf

8989Tender.pdf

xls

BOQ_879865.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail