Tender For Deposit Work Of Dad For Comprehensive Maintenance To Certain Building In Lekha Nagar, special Repair To Bldg No P-04 (01 To 04) Ors Accn And Provn Of 01 X Toilet Cum Bathroom At P-47 (Key Personal Qtr S/S) At 810 Cetc Under Ge Roorkee
Tender Overview
Project Description
Tender for Deposit Work Of Dad For Comprehensive Maintenance To Certain Building In Lekha Nagar, special Repair To Bldg No P-04 (01 To 04) Ors Accn And Provn Of 01 X Toilet Cum Bathroom At P-47 (Key Personal Qtr S/S) At 810 Cetc Under Ge Roorkee
BOQ
| Sl. No. | Item Description |
| 1 | M&L for brick work in CM 1:6 using Sub class ‘B’ Bricks straight or curved on plan exc 6 m mean radius complete all as specified and directed. |
| 2 | M&L for 15 mm thick rendering in cement mortar (1:4) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. |
| 3 | M&L for 75mm thick plane cement concrete (1:3:6) type C-1 (using 20 mm graded stone aggregate) as in flooring, hard standing, plinth protection and the like, laid in alternate bays n.exc 2.50 Sqm and joints filled with mastic filling including finishing even and smooth without using extra cement complete all as specified and directed. |
| 4 | M&L for 75mm thick cement concrete (1:4:8) type D-2, (using 40mm graded stone aggregate) as in sub base/leveling course complete all as specified and directed. |
| 5 | M&L for 60 mm thick Machine pressed precast conctete interlocking paver block of any shape and size, conforming to IS 15658-2006 of M-35 grade with grey cement and pigment & supply and laying clean dry river sand in 25 mm thick layer for cushioning complete all as specified and directed. |
| 6 | M&L for Machine cut kota stone slab flooring 20-22mm thick over15 mm thick screed bed in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. |
| 7 | M&L for Machine cut kota stone slab in riser of steps, skirting, dado and pillar, 20-22mm thick with over and including 10mm thick cement mortar (1:4), set in neat grey cement slurry and jointed with grey cement mixed with pigment to match the shade of the slab including rubbing and polishing with mirror finish complete all as specified and directed. |
| 8 | M&L for granite 14-16 mm thick (table rubbed and polished) in gate, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl molding of front side if required complete all as specified and directed. |
| 9 | M&L for precast reinforced cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate) as in landings, cover slabs for manholes, kitchen platform etc and similar articles with plain fair faces, including chamfers, weathering, throating etc and setting in cement mortar (1:6) with joints to match complete all as specified and directed. |
| 10 | S&F mild steel TMT reinforcement bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 11 | M&L Vitrified tiles 8-10 mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 12 | M&L Vitrified tiles 8-10 mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in dado set and jointed in neat cement slurry and pointed in white or coloured cement to match and incl laid over as on vertical surfaces such as skirting, dados, etc, including 10 mm thick rendring in CM 1:4, complete all as specified and as directed. |
| 13 | M&L for glazed ceramic colour joint free tiles in vertical surface size 450X 350X 7 mm/450x 300 x7mm thick as required set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10 mm thick rendering in CM 1:4 complete all as specified and directed. |
| 14 | M&L Non-skid Ceramic coloured joint free tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl 15 mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 15 | M&L for complete removal of existing treatment on walls, cornices etc by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots incl preparation of old decorated surfaces of walls and applying 1.00mm thick wall care putty of approved makes as on wall surfaces and two coats of oil bound distemper (White or tinted) complete all as specified and directed. |
| 16 | M&L for complete removal of existing treatment on ceiling, and applying two coats of white wash complete all as specified and directed. |
| 17 | M&L for complete removal of existing treatment on wall, cornices etc by brooming down or steel wire brushing, scrapping down incl preparation of old decorated surfaces of wall and applying two coats of white wash complete all as specified and directed. |
| 18 | S&F in repairs GI tubing ISI marked medium grade 15 mm bore with all fittings and fixed complete incl cutting chasing in wall for concealing of pipe if required complete all as specified and directed. |
| 19 | S&F in repairs brass chromium plated bib tap (long body) for iron pipe of 15 mm bore fancy type with crutch or butterfly handle, screwed down high pressure complete all as specified and directed. |
| 20 | S&F in repairs stop/Angle cock ISI marked fancy type, chromium plated, screw down high pressure with crutch or butterfly handle screwed both ends suitable for iron pipe of 15 mm bore complete all as specified and directed. |
| 21 | S&F PVC connection 450 mm long with 2 Nos brass check nuts suitable for 15mm bore of pipe with washer complete all as specified and directed. |
| 22 | S&F in repairs 10 ltrs PVC (White) valve less syphonic action type, flushing cistern low level with inlet ball valve float, handle, Aluminium brackets for bottom support fixing with gitties embedded in wall with drilling machine etc complete all as specified and directed. |
| 23 | S&F in repair vitreous china squatting pan (Orissa pattern) long pan including connection to trap, and to flushing pipe, anti-syphonage pipe etc incl making good to floor fixed in repair size 580x440mm white glazed with integral footrest with 'P' or 'S' trap complete (excluding flushing cistern and flush pipe) complete all as specified and directed. |
| 24 | S&F in repairs vitreous china wash hand basin, white flat back size 550x400mm (excluding tap) but including Waste coupling, waste pipe, porcelain stopper and a pair of MS bracket etc complete all as specified and directed. |
| 25 | S&F in repairs 15mm Fancy type Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed |
| 26 | S&F of stainless steel soap dish complete all as specified and directed. |
| 27 | S&F in repairs PVC (SWR) pipes single socketed (ISI Mark) in any length with rubber ring joints fixed to wall (75 mm bore) including taking down complete all as specified and directed. |
| 28 | S&F in repairs PVC (SWR) bends/elbow 75 mm (ISI Mark) complete all as specified and directed. |
| 29 | S&F in repairs PVC (SWR) 'T' 75mm complete all as specified and directed. |
| 30 | S&F in repairs PVC (SWR) pipes single socketed (ISI Mark) in any length with rubber ring joints fixed to wall (110mm bore) including taking down complete all as specified and directed. |
| 31 | S&F in repairs PVC (SWR) bends/elbow 110 mm (ISI Mark) complete all as specified and directed. |
| 32 | S&F in repairs PVC (SWR) 'T' 110 mm complete all as specified and directed. |
| 33 | Taking down shutters of any description exc 1 sq. m and n exc 2 sq. m each complete all as specified and directed. |
| 34 | Taking down chowkhat or frames with shutters (without taking off shutter from the frame) exc 1.5 Sqm but n exc 4 Sqm each incl cutting hole and making good for disturbed surfaces complete all as specified and directed . |
| 35 | Taking down chowkhat or frames with shutters (without taking off shutter from the frame) not exc 1.5 Sqm each incl cutting hole and making good for disturbed surfaces complete all as specified and directed . |
| 36 | M&L MS Frame work as post struts with angle iron welded together ends of angle shouldered and fixed complete all as specified and directed |
| 37 | M&L for MS Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc (Fe-290 (Gde E-165) complete, drilled for fixing of steel sheeting or other covering. Doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed. |
| 38 | S&F 1mm thick Mild steel, plain, black sheet in hearths covering to door shutters covering to door chowkats (frames) chullah hoods water tanks water troughs ducts urinal troughs and funnels, etc. cut to size edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc, with plain 40 mm lap joints or welded/riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required complete all as specified and directed. |
| 39 | M&L for preparation of newly steel and iron surfaces of any description exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed. |
| 40 | S&F 30 mm thick flush shutters, solid core construction with block board core and plywood face panels, water proof/ weather proof type on both sides complete all as specified and directed. |
| 41 | S&F 30 mm thick 2nd class HW Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkhat complete all as specified and directed . |
| 42 | S&F 250 mm stainless sliding door bolts, plate type, bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and directed. |
| 43 | S&F mild steel 100 mm size of butt hinges, medium weight cold rolled complete for door etc with welding to steel chowkhat at any floor up to four storied bldgs and making it functional complete all as specified and directed. |
| 44 | S&F stainless steel barrel tower bolts, fixed 150mm long bolts, fixed complete all as specified and directed. |
| 45 | S&F stainless steel handles oval type, 150 mm size complete all as specified and directed. |
| 46 | S&F solid PVC door frame of size, 50x47mm, made out of 5mm thick plain colour PVC sheet, reinforced with MS square tube fixed with screw/plugs to brick walls complete all as specified and directed. |
| 47 | S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing complete all as specified and directed. |
| 48 | Providing and fixing factory made uPVC white colour Sliding window Three track (Area not exceeding 2.00 sqm each) made of extruded profiles with wall thickness of 2.3mm (+/- 0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). liding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) 45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc, making arrangement for fixing of hardware. EPDM gasket, 1.2+/-0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 00mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. (Note: The unit rate quoted by contractor includes cost of 6mm thick toughened glass and includes all other connected accessories. Net Opening will be measured for payment purpose) |
| 49 | S&F factory made uPVC white colour fixed glazed window/ventilator made of (small series) frame 47x50mm mullion 47x68mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area upto 0.75 sqm.) omprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, GI fasteners 100x8mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Note: The unit rate quoted by contractor includes cost of 6mm thick toughened glass and includes all other connected accessories. Net Opening will be measured for payment purpose.) |
| 50 | Providing and fixing stainless steel (Grade 304) Hollow tubes, channels, etc, including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete complete all as specified and directed. |
| 51 | Hacking out old broken glass (any thickness, size, quality or description) from wooden/metal frames, glazed with oil putty or fixed with beads including punching or drilling out old glazing pins/spring clips and providing new glazing pins/ spring clips complete all as specified and directed. |
| 52 | S&F of 3 mm thick plain, ordinary quality sheet glass and glazing with oil putty or fixed with wooden beads in square not exc. 0.5 sqm in each pane complete all as specified and directed. |
| 53 | S&F galvanised MS wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tack/galvanised wire staple complete all as specified and directed. |
| 54 | S&F in repairs galvanised MS, wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tack/galvanised wire staple complete all as specified and directed. |
| 55 | M&L for preparation of newly surface of wood and wood based surfaces by knotting, stopping etc of any description exc 10 cm width or girth and applying two coats of synthetic enamel paint over a one coat of pink primer complete all as specified & directed |
| 56 | M&L for preparation of old painted surface of wood and wood based surfaces by knotting, stopping etc of any description exc 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 57 | M&L for preparation of old painted steel and iron surfaces of any description exc 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 58 | S&F in repairs for factory made Pre laminated/plain WPC board of 9mm (+/-0.7) thickness board of density 600 Kg/Cbm using for back side shutter board of shutter and fixed with the frame of kitchen accessory complete all as specified and directed. |
| 59 | S&F in repairs for factory made WPC board of 18mm (+/- 0.7) thickness of density 600 Kg/Cbm desired size of shutter and fixed with the frame of kitchen, cupboard etc accessory at all four edges of shutter using 13/6 size self tapping steel including stainless steel handle, tower bolt, magnet,piano hinges etc complete all as specified and directed. |
| 60 | S&F in repair Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed. |
| 61 | S&F in repair corner sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed. |
| 62 | Dismantling structural steel as in gates or posts any type complete all as specified and directed. |
| 63 | S&F in repair Galvanised 2 strand steel barbed wire 2.24 mm barbed with 2 mm dia barbs @ 75 mm spacing straining and fixing including securing or lying at crossing with and provision of galvanised MS staples or steel pins incl dismantling of old barbed wire complete all as specified and directed. |
| 64 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 meter openable length (total length 90 m), having 50 nos round per 6 metre length, up to 3 m height of wall with existing angle iron \\"Y‟ shaped placed 2.4 m or 3.00 m apart and with 9 horizontal RBT reinforced barbed wire, stud tied with GI staples and GI clips to retain horizontal, including necessary bolts or GI barbed wire tied to angle iron, with reinforced barbed tape (RBT)/ Spring core (2.5 mm thick) wire of high tensile strength of 165kg/ sq. mm with tape (0.52 mm thick) and weight 43.478 gm/metre (cost of MS angle, CC blocks shall be paid separately). complete all as specified and directed. |
| 65 | S&F MS Framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290 Gde-E-165 complete all as specified and directed. |
| 66 | M&L PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and directed. |
| 67 | M&L for brick work with sub class 'B' brick straight curved on plan exceeding 6 metre mean radius with old size bricks built in CM (1:4) for cracked wall of manholes, septic tank, soak pits etc complete including demolition complete all as specified and directed. |
| 68 | M&L Rendering 15mm thick plaster in cement mortar (1:4) on brick or concrete masonry walls, finished even and fair without using extra cement and using water proofing compound complete all as specified and directed.Note- (i) WPC shall be measured and paid for separately. |
| 69 | Supply only integral water proofing compound complete all as specified and directed. |
| 70 | Excavating in trenches, in any soil n exc 1.5 m width n exc 1.5 m depth in any type of soil and getting out all as specified and directed. |
| 71 | M&L SWG drain pipe 150 mm internal dia, grade `A' laid in trenches & jointed in cement mortar (1:1) including demolition and breaking up drain pipes of diameter 150 mm (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed. |
| 72 | M&L SWG drain pipe 200 mm internal dia, grade `A' laid in trenches & jointed in cement mortar (1:1) including demolition and breaking up drain pipes of diameter 200 mm (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed. |
| 73 | M&L PCC (1:3:6) type C-2 150mm dia using 40mm graded aggregate Concrete bed to drain pipes including packing under and for hauching & Benching against the sides of pipes after they are laid and tested complete all as specified and directed. |
| 74 | M&L PCC (1:4:8) type D-2 200mm mm dia using 40 mm graded aggregate concrete bed to drain pipes including packing under and for hauching & Benching against the sides of pipes after they are laid and tested all as specified and directed. |
| 75 | Returning, filling including spreading leveling watering and well ramming in layers n. exc 25 cm in soft/loose soil complete all as specified and directed. |
| 76 | Removing excavated soil to a distance n. exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed. |
| 77 | Demolition of cement concrete (un-reinforced) of any description and laid in any position complete all as specified and directed. |
| 78 | Demolishing RCC work manually/by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead complete all as specified and directed. |
| 79 | Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead complete all as specified and directed. |
| 80 | M&L for brick work with common burnt clay FPS (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1cement:6 coarse sand): complete all as specified and directed. |
| 81 | M&L for brick work 7 cm thick with common burnt clay FPS (non modular) brick of class designation 7.5 in cement mortar 1:3 (1 cement : 3 coarse sand) in superstructure above plinth level and upto floor five level complete all as specified and directed. |
| 82 | M&L for precast reinforced cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) in manhole covers including necessary form work and fixing in position in cement mortar (1:4) complete all as specified and directed. |
| 83 | Providing and fixing 16-18 mm thick granite stone slab of colour black, Cherry/Ruby red Area of slab upto 0.50 sqm gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc complete all as specified and directed |
| 84 | Ditto all as above but area of slab over 0.50sqm |
| 85 | S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor of 150mm long complete all as specified and directed. |
| 86 | S&F factory made gauged shutter shall be made out of angle iron 35x35x5mm (outer frame) and 25x25x5mm (middle rail 2 nos, 100 mm apart from each other) and 1.0mm thick steel sheet covering on middle rail, 10mm Square bars @100mm C/C fixed vertical as grill complete with stainless steel fly proof wire mesh having 0.36mm nominal dia wire and 1.4mm average with aperture, with locking arrangement complete all as specified and directed. |
| 87 | S&F 200mm Mild steel, semi-barrel tower bolt, open cover, with sheet pressed barrel, stove enamelled black with bright bolt and fixed complete all as specified and directed. |
| 88 | S&F for Powder coated aluminium window and ventilator, fixed type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, powder coated aluminium snap beading, screws, 3mm thick plain glass complete all as specified and directed. |
| 89 | Providing and fixing 30mm thick Factory made single extruded WPC (Wood Polymer Composite) solid plain lush door shutter comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screws, complete all as specified and directed. |
| 90 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/Chowkhat Frame size 50 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with termite/borer proof, water/moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete all as specified and directed. |
| 91 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed. |
| 92 | Providing and laying matt finished vitrified tile of size 300x300x9.8 mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc complete all as specified and directed. |
| 93 | Taking down cement plaster (including tiles, if necessary) of any description on Brick walls including racking out Joints, hacking for key scrubbing down with water etc complete all as specified and directed. |
| 94 | M&L for rendering 15 mm Thick in CM (1:6) on Brick surfaces, rendering complete all as specified and directed. |
| 95 | M&L for rendering 5 mm Thick in CM (1:3) on concrete surfaces, rendering is to be finished even and smooth (without using extra lime or cement) all as specified and directed. |
| 96 | Finishing walls with ready mixed Premium acrylic emulsion paint (Company Depot Tinted) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives.New work (Two or more coats applied @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm complete all as specified and directed. |
| 97 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre. applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete all as specified and directed. |
| 98 | M&L Preparation of plastered surfaces of walls and applying two coats of colour wash on walls complete all as specified and directed. |
| 99 | Providing and fixing 25 mm dia chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with CP brass screws and PVC sleeves etc, wherever necessary complete all as specified and directed. |
| 100 | Providing and fixing in repair 20 mm dia nominal bore GI Pipes complete with GI fittings and clamps, including making good the walls etc concealed pipe, (if necessary) cutting chases and making good the wall complete all as specified and directed. |
| 101 | Providing and fixing in repair 15 mm nominal dia CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. |
| 102 | Providing and fixing in repair CP brass shower rose with 15 or 20 mm inlet 150 mm long complete all as specified and directed. |
| 103 | Providing and fixing circular shape 450 mm dia looking mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing complete all as specified and directed. |
| 104 | S&F in repair sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed. |
| 105 | Providing and fixing in repair 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with CP brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etccomplete all as specified and directed. |
| 106 | S&F in repairs towel rail 600 mm long 20 mm dia Brass chromium plated fixed to wall D type with CP steel screws etc complete all as specified and directed. |
| 107 | S&F in repairs 75mm PVC (SWR) floor trap, plain with grating cover including jointing with solvent cement complete all as specified and directed. |
| 108 | Dismantling of RCC water tanks of 500 Ltr capacity and removing to store complete all as specified and directed. |
| 109 | M&L white coloured 500 ltrs Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) incl 20mm PTMT ball valve hoisted and fixed in position all as specified in SSR Part I. |
| 110 | S&F 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed |
| 111 | Taking down old existing water proofing treatment from the top of RCC/arch slab, including taking down existing PCC padding or plaster and hacking the top of RCC slab, cleaning with water and disposal of rubbish off the premises including taking down of existing steel water tubing for water supply and re-fixing the same after application of roof treatment complete all as specified and directed |
| 112 | M&L cement concrete (1:2:4) type B0 (using 12.5mm graded crushed stone agg) as in roof levelling, finished even and fair, complete all as specified and directed |
| 113 | M&L for roof treatment with polymeric membrane (APP based) with non woven polyester mat as reinforcement with following:-(a) M&L for providing & laying a coat of cold applied bitumen 85/25 based primer on entire surface @ 0.30 Ltr/Sqm on dry and clean surface.(b) M&L for providing & laying APP based polymeric membrane of 3 mm thickness of weight of 3.5 Kg/Sqm with non woven polyester fibre as reinforcement on primed surface by torch application with side over laps & joints over laps etc as per manufacturers instruction.(c) M&L for finishing of top surface by two coat of aluminium paint over a coat of blown bitumen 85/25 grade @ 1.2 Kg/Sqm grouted all as specified and as per manufacturers instruction |
| 114 | M&L Cement concrete type B1-1:2:4 (using 12.5 mm graded crushed stone agg) in roof kerbs or mud stop rounded or chamfered on edge,coping etc complete all as specified and directed |
| 115 | M&L for rendering 15mm thick in cement mortar (1:3) mixed with water proofing liquid on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. |
| 116 | M&L for Reinforced concrete pipes, class NP2, with collars laid in trenches and jointed in cement mortar (1:1) complete all as specified and directed. |
| 117 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft / loose soil complete all as specified and directed. |
| 118 | M&L for hardcore of gauge not exceeding 63 mm of broken stone, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 119 | Use and waste formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and as directed. |
| 120 | Use and waste of flat Form work (Rough finished) to sides of concrete beams and similar work, vertical or batter complete all as specified and as directed. |
| 121 | Use and waste of Fair finished flat Form work to soffits of suspended slabs such as roof slabs, floor slabs and similar work not exceeding 200 mm thick complete all as specified and as directed. |
| 122 | M&L Mild steel bar 5mm dia and over up to 8mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips |
| 123 | M&L for RCC Type M20 (using 20mm graded granite stone aggregates) as in Beams, lintels and etc., complete all as specified and as directed. |
| 124 | M&L for RCC Type M20 (using 20mm graded granite stone aggregates) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. |
| 125 | Providing and fixing white vitreous china pedestal type water closet (European type WC pan) with seat and lid, 10 litre low level white PVC flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required WC pan with ISI marked white solid plastic seat and lid complete all as specified and directed. |
| 126 | Providing and fixing wash basin size 630x450 mm with CI brackets, 15 mm CP brass pillar taps, 32 mm CP brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require complete all as specified and directed. |
| 127 | Providing and fixing 32mm dia flexible PVC waste pipe for sink or wash basin including PVC waste fittings complete all as specified and directed. |
| 128 | Providing and fixing CP brass toilet paper holder complete all as specified and directed. |
| 129 | M&L for 100 dia cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed. |
| 130 | Dismantling and taking down carefully U/S copper/aluminium point wiring (light, fan, socket, power) complete fitting such as switches, ceiling roses, pendants, lamp holder, light fitting etc including CI/Pressed steel terminals, switch box, and making good the disturbed surface of wall/floor etc, to match with the existing surfaces of wall/floor complete all as specified and directed |
| 131 | Dismantling and taking down carefully sub-main wiring/ service wire of any size including wooden batten etc and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc complete all as specified and directed |
| 132 | Dismantling and taking down carefully existing DB’s any type and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc complete all as specified and directed |
| 133 | M&L for point wiring with 1.5 sq mm PVC insulated, unsheathed, stranded copper conductor (FRLS-H) cable single core 1100 Volt grade in and including rigid PVC conduit medium grade 20mm dia or more ISI Marked concealed conduit and conduit accessories and cutting chases of suitable girth where required on brick/concrete surface & making good disturbed surface,provision of GI/Pressed steel terminal switch box with plastic laminated sheet 3 mm thick fixed with brass screw and washers along with 1.5 sq mm PVC insulated unsheathed stranded copper conductor cable (FRLS-H) as earth wire connected with main common earth dolly complete all as specified and directed for the following :-One light/fan/bell/exhaust fan point controlled by one, one-way non modular switch 5/6 Amp complete all specified and directed. |
| 134 | One 3pin/5pin 5/6 Amps socket out let on same board controlled by one, one-way non modular switch complete all specified and directed. |
| 135 | One 3pin/5pin 5/6 Amps socket out let on independent board controlled by one, one-way non modular switch complete all specified and directed . |
| 136 | All as per item No 133 here-in-before but wiring with 2.5 sqmm single core multi stranded copper condcutor 1100 V grade PVC insulated FRLS but unsheathed single core for16 Amps power point on independent board and 2.5 sqmm FRLS cable as earthwire complete all specified and directed. |
| 137 | S&F switch piano flush type white finish 5/6 Amps, single pole one way, 230 volts, 50 hz complete all as specified and directed |
| 138 | S &F socket out let 2 pin 5/6 Amps & 3 pin 5/6 Amps flush type, 230 volts, 50 hz complete all as specified and directed |
| 139 | S&F switch piano flush type white finish 15/16 Amps single pole one way, 230 volts, 50 hz complete all as specified and directed |
| 140 | S&F socket out let 5 pin 15/16 Amps & 3 pin 5/6 Amps flush type, 230 volts, 50 hz complete all as specified and directed |
| 141 | S&F fan regulator, stepped type, electronic (socket type), 100 watt compatible with BLDC FAN complete all as specified and directed. |
| 142 | S&F in replacement of bell push switch flush type 6 Amps, 240V, 50Hz, complete all as specified and directed |
| 143 | S&F in replacement of electric call bell ding dong type, AC, 240V, 50Hz, complete all as specified and directed |
| 144 | S&F lamp holder (Angular/Straight), insulated body, with back plate for batten fitting complete all as specified & directed. |
| 145 | S&F LED Bulb 9 Watt (cool day light) having colour temp 6500 K and lumen output 950 suitable for \\"B-22 type to fix on batten holder complete all as specified and directed. |
| 146 | M&L ceiling rose 3 terminal/PVC/polycarbonate, isolated body complete all as specified and directed |
| 147 | S&F sheet metal enclosures with metal socket and plug top Single pole and neutral enclosure with a two pin and earth plug and socket complete ISI marked, 230/240 volts, 50 hz with one single pole MCB SP 25 Amps complete all as specified and directed |
| 148 | S&F MCCB/MCB distribution board, Vertical TPN, 4 way, 415 V, 3 phase, AC with MCCB as incomer and MCBs as outgoing in sheet steel powder painted enclosure double door type with 200 Amps rated busbar minimum IP 43 degree of protection with built in copper bus bar of suitable size, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface including taking down existing unserviceable MCB DB of any description complete all as specified and directed. Note: MCCB/MCBs shall be measured and paid separately. |
| 149 | S&F of MCB distribution board, SPN, 8 way, 230 V, 1 phase, AC and MCBs as outgoing in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface including taking down existing unserviceable MCB DB of any description complete all as specified and directed.Note: MCBs shall be measured and paid separately. |
| 150 | S&F MCB, SP, AC, 240 volts of 06 to 32 Amps capacity 10KA, 'B' series and making connections with suitable size of copper lugs complete all as specified & directed.Note: MCBs should be of same make as of DB 8 way |
| 151 | S&F MCB, SPN, AC, 240 volts of 40 Amps capacity 10KA, 'B' series and making connections with suitable size of copper lugs complete all as specified & directed.Note: MCBs should be of same make as of VTPN 4 way and DB 8 way |
| 152 | S&F MCCB 100A, 16 KA, 4 Pole, 415 V, 50 Hz, Ics=100% Icu with fixed thermal magnetic release fixed in Vertical TPN complete all as specified and directed.Note: MCCB should be of same make as of VTPN 4 way |
| 153 | S&F in replacement of old unserviceable LED T5 tube light fitting 20 watts full white and warm white dual with polycarbonate housing and polycarbonate diffuser with integrated electronic driver with all accessories including connecting up with PVC insulated and PVC sheathed twisted three core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting complete all as specified and directed. |
| 154 | S&F LED 25 watt Building security light fitting mounting type made out of one piece in pressure die-cast aluminium housing with high efficient LED as lighting source and PC Cover separate compartment for driver,including bracket clamp and fixing accessories complete with electronic driver and all accessories. The fitting shall IP 66 protection, duly prewired complete all as specified and directed. |
| 155 | S&F in replacement of old unserviceable LED mirror light fitting Integral slim LED batten Integral 9/10 watts of 2 feet long internally prewired complete with all accessories and including connecting up with pvc insulated and pvc sheathed twisted two core wire of suitable size complete all as specified. |
| 156 | S&F sub main wiring two single core 6 sq mm PVC insulated unsheathed stranded copper conductor cable (FRLS) 1100Volts grade drawn in & including rigid PVC conduit 20mm dia or more medium grade concealed in wall along with 6.00 Sq mm PVC insulated unsheathed copper conductor cable (FRLS) as earth wire and wire connected with main earth dolly including cutting chasing and making good disturbed portion all as specified and directed. |
| 157 | Ditto all as above but 4sqmm size |
| 158 | S&F in repair BLDC Ceiling fan with regulator complete with three blades down rod, accessories 230 V, 1200mm sweep, copper winding, BEE 5 star white/warm white with squirrel cage induction motor, minimum air delivery 210 CFM complete all as specified and directed.Note: Old Ceiling fan to be deposited in MES store Yard |
| 159 | S&F in repair Exhaust fan Steel body AC single phase 230/240 Volt of size 300 mm sweep, complete with louvers including making whole and grouting of nut bolts etc and making good the disturbed sufaces of wall all as specified and directed .Note: Old Exhaust fan to be deposited in MES store Yard |
| 160 | S&F in repair Exhaust fan PVC body AC single phase 230/240 Volt of size 250 mm sweep, RPM not less than 1100 RPM complete with louvers shutter including making whole and grouting of nut bolts etc and making good the disturbed sufaces of wall all as specified and directed .Note: Old Exhaust fan to be deposited in MES store Yard |
| 161 | S&F in repair electric water heater, storage type steel body with stainless steel inner tank and heating element upto 1.5/ 2 KW capacity 25 litre, BEE 5 Star rated, ISI Marked, 240 V, 50 Hz complete with all accessories such as safety valve, thermostate, NRV, Hot and cold water connection pipe all as specified and directed.Note: Old Water heater to be deposited in MES store Yard |
| 162 | S&F in replacement of 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor twin core, 16 sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections including connecting on LT OH line/energy meter/DB etc complete all as specified and directed. |
| 163 | Supply, Installed & fix maintenance free earthing copper bonded steel earth rod of 10 feet long having diameter of 17.2mm with copper bonding thickness of 250 micron, UL listed,CPRI Tested at 25 KA fault current for one second and is provided with universal clamp made of SS earth enhancing compound shall be of 50kg/pit(resistivity is less than 0.12 Ohm meter) tested as per IEC 62561-7. The above arrangements shall be provided with heavy duty earth poly plastic pit cover of 6000 kg load bearing capacity (Size:270 x 240 x 200mm) and FRLS insulated copper conductor of size 6 sqmm, single core cable drawn through and including light grade GI pipe of size 15 mm upto 7 mtr incl cutting and chases on wall and floor and aking good using PCC complete all as specified and directed.Note : On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. |
| 164 | Dismantling & taking out old unserviceable LT UG cable & Supplying & laying in replacement of LT UG cable (Conforming to IS 1554) ISI marked 1.1 KV grade XLPE insulated PVC sheathed steel armoured aluminum stranded conductor in trenches/ducts/through HDPE pipe under roads of size 25 sqmm 4 core complete all as specifed and directed. |
| 165 | M&L for Double wall corrugated HDPE pipe, ISI marked of outer dia 50mm, inner dia 38mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts complete all as specified and directed. |
| 166 | S&F GI tubing light grade ISI marked of 50 mm bore dia complete all as specified and directed. |
| 167 | Drilling and tapping GI water mains 50mm bore (in position) for branch connections of the internal dia 20mm, complete all as specified and directed. |
| 168 | S&F straight plain brass ferrules (or connecting screws) screwed both ends and fixed to water mains for tapping branch connection of 20 mm bore pipe, complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender