Tender For special Repair To Bldg No T95 And T-75 At 408 Fd Hosp And Provn Of Toilet Block Consisting 04 X Urinal Pot And 04 X Wc In The Aor Of Age Br-Ii Khaltsi Under Ge Khumbathang.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
10 Sep 2026
18 days left
EMD
55200
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kargil → Jammu And Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special Repair To Bldg No T95 And T-75 At 408 Fd Hosp And Provn Of Toilet Block Consisting 04 X Urinal Pot And 04 X Wc In The Aor Of Age Br-Ii Khaltsi Under Ge Khumbathang.
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling wall and ceiling board of insulation boards/ slabs/ blankets any description and thickness in any posn incl cover fillets complete all as specified and directed. |
| 2 | M&L 9 mm thick, prelaminated particle board, interior grade, prelaminated both side with decorative choice laminated fixed with nails to timber frame work as in ceiling. |
| 3 | M&L 12 mm thick, prelaminated particle board, interior grade, prelaminated both side with decorative choice laminated fixed with nails to timber frame work as in wall. |
| 4 | M&L factory made second class soft wood wooden battens kiln dried spruce or pine profiled lumber, not less than 12mm thick, length 3000 mm & width 110-120 mm insert each other with male and female grooves fixed with nails to timber frame work as in wall/ceiling panelling, shelves etc including dismantling old wall/ceiling board any type and applying under coating and finishing coats of wood polishing complete all as specified and directed (Make-Beliy Ruchey or equivalent |
| 5 | Dismantling timber scantling under 40 Sqcm on flats, rails, posts, rafter, purlins etc.in unframed work complete all as specified and directed. |
| 6 | M&L second class soft wood, plain fillets, square or rectangular in section of area exc 13 and n exc 25 Sqcm, clean sawn, secured with nails or brads complete all as specified and directed. |
| 7 | M&L for 2nd class softwood n exc 3 sq cm section area bull nosed, splayed chamfered or rounded on one edge of fixed to ceiling / wall complete all as specified and directed. |
| 8 | M&L for 2 class softwood moulding as in cornices , picture,rails etc sectional area exc 3 sq cm & n exc 6 sqcm complete all as specified and directed. |
| 9 | Dismantling plain or corrugated steel sheeting, any gauge, thickness including Nanital patterns roof covering. complete all as specified and directed. |
| 10 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed. |
| 11 | S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 12 | Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises. |
| 13 | M&L for non skid coloured ceramic tiles 7 to 8 mm thick (Square/ rectanglar) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc; set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including 15 mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 14 | M&L Vitrified ceramic tiles light shade 10mm thick (Square/rectanglar) area of each tile not exceeding 0.36 sqm in floors etc; set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including 15 mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 15 | Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc 1.5 sq. but n exc 4 Sqm each complete all as specified and directed |
| 16 | Taking down Shutters of any description exc 1 sq. m but n.exc 2 Sqm each complete all as specified and directed |
| 17 | Taking down chowkhats or frames with shutters (without taking off shutter from the frame) wooden/Aluminium/Iron n exc 1.50 Sqm each complete all as specified and directed. |
| 18 | S&F Second class softwood plain , solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered , put together with glue pinned at joints supplied and fixed complete all as specified and directed. |
| 19 | S&F second class soft wood 35 mm thick plain framed panelled shutters (any numbers of panels) with panels of timber flat on both sides (feather edged) or of veneered particles board medium density wood particle board with commercial face veneers,supplied and fitted to chowkats complete all as specified and directed. |
| 20 | M&L for two coat of synthetic enamel paint (finishing coat) over one coat of pink primer to new wooden surfaces of any description over 10 cm width or girth incl prepration of surfaces complete all as specified and directed. |
| 21 | S&F Aluminium powder coated door window frame for door,window / ventilaror/partitions with one or more rebate including joining cleat for fixing etc, complete all as specified and directed. |
| 22 | S&F Anodised aluminium powder coated door shutters, aluminium section weighing not less than 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles (150 mm) 02 Nos in each door, hinges (100 mm ) 03 Nos each door, anodised aluminium snap beading, screws, etc complete all as specified and directed by Engr-in-charge. |
| 23 | S&F Anodised aluminium powder coated window glazed shutters, top hung type without sash bars, aluminium section weighing not less than 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150 mm long (01 Nos), hinges type B-21 100 mm long (02 Nos), suitable handle 125 mm long (01 Nos) etc complete all as specified and directed by Engr-in-charge. |
| 24 | S&F 5.5 mm thick ordinary quality glass sheet in squares exc 0.5 sqm in each pane fixed to door/windows for glazing with and including oil putty or aluminium beads and rubber packing complete all as specified and directed. |
| 25 | S&F 5.5 mm thick ordinary quality glass sheet in squares n.exc 0.5 sqm in each pane fixed to door/windows for glazing with and including oil putty or aluminium beads and rubber packing complete all as specified and directed. |
| 26 | S&F Aluminium alloy anodised sliding door bolt with hasp staple ( bolt type ) 250mm long , staple (bolt type) and fixing bolt with and sliding bolts of extruded sections or cast-aluminum alloy and fixed. |
| 27 | S&F in repair for aluminium mortice lock, vertical type, size 100 mm 02 Lever complete all as specified and directed. |
| 28 | S&F 150 mm aluminium anodised barrel tower bolt of extruded section and fixed. |
| 29 | S&F 100 mm size mild steel butt hinges, medium weight cold rolled (including fixing with nails/screws or welded as required) complete all as specified and directed. |
| 30 | S&F 150 mm size Aluminium handles, cast type, anodised |
| 31 | S&F in repair door closer draulically regulated aluminium (extruded section body), designation No. 1 universal type, suitable for door shutters up to 700 mm in width and of weight not more than 35 kg |
| 32 | S&F in repair Vitreous China wash down pedestal pattern EWC, white water closet pan with intergral trap including seat cover ,making necessary connections to drain and to flushing pipe antisyphonage pipe etc, jointing to PVC/CI and flush pipe including making good to floor complete all as specified and directed. |
| 33 | S&F in repairs PVC flushing cistern dual type 10 Litres capacity incl all accessosaries complete all as specified and directed. |
| 34 | Health faucet (ABS Body) in repair mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 35 | S&F in repairs 15mm bore Bib Tap Chromium plated fancy type complete all as specified and directed. |
| 36 | S&F in repairs in 15mm bore Stop Valve (Angle Valve) chromium plated fancy type complete all as specified and directed. |
| 37 | S&F in repair PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed. |
| 38 | S&F in repair 600x450mm bevelled edge mirror or selected quality galass, mounted on 6mm thick AC bldg board or commercial plywood and fixed to wooden plugs with CP brass screws and cup washers complete all as specified and directed. |
| 39 | M & L PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete in all respect as specified. |
| 40 | S & F PVC water tank three layer 1000 ltr capacity rotational moulded polye thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position complete in all respect as specified. |
| 41 | Taking up or down steel tubing and connections, including cleaning for refixing or removal to store 20 mm bore pipe complete all as specified and directed. |
| 42 | S&F 16mm outer dia 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN-16) UV stablised and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc |
| 43 | S&F 25mm outer dia 3-layer PP-R Polypropylene random copolymer) pipes SDR 7.4 & SDR 11 UV stablised and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc |
| 44 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thick (below or above ground level) complete all as specified and directed. |
| 45 | M&L for 75mm thick in PCC 1:3:6 type C-1 as in plinth protection surface finished even and smooth without using extra cement comlete all as specified and directed |
| 46 | M&L for 100 mm thick cement concrete type D-2 1:4:8 (40mm graded aggregate) as in sub base to floor or for laying of floor finishes or similar works complete all as specified and directed. |
| 47 | M&L coloured chequered cement concrete tiles of size 300mm x 300mm x 20 mm, set, jointed and pointed in neat cement slurry with grey cement and pigment in floors thick laid over and including 20 mm thick screed bed in CM 1:4 bedded and jointed in neat cement slurry complete all as specified and directed. |
| 48 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out hard/dense soil complete all as specified and directed. |
| 49 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundations etc or for shafts, wells cesspits, manholes, pier holes etc n.exc 10 Sqm on plan and n.exc 1.5m in depth and getting out in hard/dense soil complete all as specified and directed. |
| 50 | Returning filling in, including spreading leveling, watering and well ramming in layers not exceeding 25cm in hard dense soil complete all as specified and directed. |
| 51 | Removal of excavated soil to a distance n. exc 50 and depositing where directed at a level n.exc. 1.5 m above the starting point complete all as specified |
| 52 | M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation etc, complete all as specified & directed |
| 53 | M&L for precast cement concrete block masonry with solid block exc 10 cms in width made with PCC 1:3:6 type C-1 (using 20 mm graded aggregate) and set in CM 1:6 complete all as specified and directed. |
| 54 | M&L 12 mm thick rendering on fair faces of brick work or concrete surface in cm 1:6 to be finished even and smooth without using extra cement complete all as specified and directed. |
| 55 | M&L 15 mm thick cement plaster in CM 1:4 on brick work or concrete surface other than fair face or brick work and finished surface even and smooth without using extra cement complete all as specified and directed. |
| 56 | M&L for preparation of newly plastered surfaces of walls including cornices, pillasters etc, and applying two coats of oil emulsion distemper over and including one coat of chalk whiting preparatory to distempering complete all as specified and directed. |
| 57 | M&L for preparation of newly plastered surfaces of walls including cornices, pillasters etc, and applying two coats of cement base paint over a coat of primer complete all as specified and directed. |
| 58 | M&L Hard core broken stone boulders of gauge not exceeding 63mm broken stone deposited spearding and levelled in layers not exceeding 15cm thick watered and well rammed to a ture surfaces complete all as specified and directed. |
| 59 | M&L Glazed ceramic white colour tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 15 mm thick rendering in CM 1:4 complete all as specified and directed |
| 60 | M&L for white non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or Coloured cement to match the existing surface laid over 20mm thick avg screed bed in CM 1:6 complete all as specified and directed. |
| 61 | S&F vitreous China Squatting pan 'Orrisa' pattern size 580x440mm white with integral foot rest, and jointing to PVC/CI bend and flush pipe complete including making good to floor complete all as specified & directed. |
| 62 | S&F 15mm bore size pillar tap cast copper alloy chromium plated fancy type complete all as specified and directed. |
| 63 | S&F vitereous china wash hand basin, white, flat back of size 550 x 400 mm including brackets, cutting for pinning in ends of brackets or erecting stand and including PVC waste pipe complete all as specified and directed. |
| 64 | S & F Soap dish, vitreous China white, approximate size 160x 160x90mm complete in all respect as specified. |
| 65 | S&F PVC (SWR) pipes single socketed in in any length with rubber ting joints, laid in trencehs or in floors 75mm mm dia complete in all respect as specified. |
| 66 | S&F 30 mm thick second class soft wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed. |
| 67 | S&F 75 mm size mild steel butt hinges, medium weight cold rolled (including fixing with nails/screws or welded as required) complete all as specified and directed. |
| 68 | S&F 100 mm aluminium anodised barrel tower bolt of extruded section and fixed.complete all as specified and directed. |
| 69 | S&F 100 mm extruded aluminium alloy handles, fabricated type , anodised complete all as specified and directed. |
| 70 | S&F Roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channelor flat sections) includingdistance pieces, cleats etc complete all as specified and directed. |
| 71 | S & F Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars,stiffeners, gusset plates, etc. |
| 72 | S & F vitreous china urinals bowl ,flat back of size 465 x 355 x 265 mm with grating and union for discharge pipe, complete including providing and fixing plugs , bedding urinal against wall in cement mortar 1:2 , securing urinal to pluigs with and including 60 mm long brass screw , pointing around urinal back in cement incl provn of flush pipe, grating and union for discharge pipe, all as specified and directed. |
| 73 | M & L 110mm bore for PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed. |
| 74 | M & L 100 mm cement Concrete 1:3:6 type C-2 Concrete bed to drain pipes including packing under,and haunching against the sides of pipes after they are laid and tested;in complete all as specified and directed. |
| 75 | S & F PVC (SWR) bends any radius 110mm bore complete all as specified and directed. |
| 76 | S & F PVC (SWR) bends any radius 75mm bore complete all as specified and directed. |
| 77 | S & F PVC (SWR) Single T any radius 110mm bore complete all as specified and directed. |
| 78 | S & F PVC (SWR) Single T any radius 75mm bore complete all as specified and directed. |
| 79 | S&F FRP septic tank designed to carry sewage and sludge water. Capacity (1000Ltr) with upflow filter including media.complete all as specified and directed by Engr-in-Charge. |
| 80 | Taking down old unsv copper/aluminium point wiring concealed / batten (light, fan, socket or power) complete, including fixture and fittings such as switches, sockets, ceiling roses, bell push, bell electric, lamp holder, bulk head fitting, pendants, regulators, sockets, light fitting and any type switch board wooden/iron, round block etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. |
| 81 | Taking down un-serviceable DB of any size and capacity including MCB etc. and removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc., complete all as specified and directed. |
| 82 | Material and labour for point wiring with 1.5 sqmm cable FRLS PVC insulated, unsheathed copper multi stranded conductor, 1100 V grade of size 1.5 sqmm incl 1.5 Sqmm PVC insulated unsheathed FRLS copper conductor as earth wire ( green in colour) and connected to common earthing with PVC heavy duty casing capping/PVC conduit ISI marked concealed in wooden panelling as required at site along with MS/SS modular sunken boxes of size as required at site along with modular cover frame and cover plate for fixing switches , sockets regulators incl accessories and making good the disturbed surfaces of wall/ ceiling etc. for the following : - |
| 83 | One light point/ one fan point/ Bell Point controlled by one switch |
| 84 | One 3 pin socket outlet, 5 Amp independent |
| 85 | One 3 pin socket outlet 5 Amps on same board |
| 86 | S&F modular switch type 5/6 Amps one module all as specified and directed . |
| 87 | S&F modular socket 5 amp 3 pin 02 module type complete all as specified and directed . |
| 88 | S & Fix Ceiling rose 3 terminal flush type 6 Amps,250 volts AC ISI marked |
| 89 | S&F PVC exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm complete all as specified and directed. |
| 90 | All as per item No 82 above but for point wiring for power point with 2.5 Sqmm FRLS PVC insulated unsheathed copper cable 1100 Volt grade drawn through and including PVC casing capping heavy duty ISI marked /heavy duty conduit ISI marked as required at site alongwith with modular cover plate and cover frame of suitable size as required at site incl all accessories with 2.5 Sq mm FRLS PVC insulated unsheathed copper conductor cable as earth wire ( green in colour ) and connected to common earth all as specified. |
| 91 | S & F modular socket 5 pin 16/6 Amp 02 module flush type complete all as specified and directed. |
| 92 | S & F modular switch 15/16 Amps 01 module complete all as specified and directed. |
| 93 | S&F in replace warm white/ white LED luminaire 600X600 mm,35/36 watt,220V recessed type lumen output >= 122 lumen per watts , THD < 10% environmental friendly , new generation , aesthetically designed , ultra modern with high brightness SMD LEDs as light source incl inbuilt drivers with high efficiency PMMA diffuser soft glare free light warm white complete suitable for roof ceiling including connecting up with three core flexible copper conductor of suitable size all as specified and directed. |
| 94 | S & F LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220 V AC decorative type with THD less than 15% very high efficiency suited for T-5 tube luminaire with system efficacy 110 lumen per watts , high quality poly carbonate end cap in white finish and snap fitted to the housing, inbuilt driver incl copper connecting wire three core of suitable size upto connector of ceiling rose complete all as specified and directed. . |
| 95 | S & F decorative ultra slim polycarbonate LED 4 feet long 20/22 watts with THD less than 15% very high efficiency suited for T-8 tube luminaire with system efficacy 110 lumen per watts, high quality poly carbonate end cap in white finish and snap fitted to the housing, inbuilt driver incl copper connecting wire three core of suitable size up to connector of ceiling rose complete all as specified and directed. . |
| 96 | S & F light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 97 | Taking down old u/s submain wiring of any sizes complete incl conduits/PVC casing n caping all as specified & directed. |
| 98 | M&L for sub main wiring with two run of single core PVC insulated copper cable FRLS multi-stranded conductor 6 Sqmm drawn through in and including Non-metallic PVC heavy duty PVC casing capping of suitable size as required at site with all accessories with one run of 6 Sqmm PVC insulated unsheathed copper conductor FRLS as earth wire ( green in colour ) , connected to common earth complete all as specified and directed.Note: 1. Two run of main copper conductor 6 sqmm size, one run of 6 sqmm earth wire and one run of PVC conduit/PVC casing n capping shall be measured as one unit length.2. Proper colour coding shall be maintained as per IS code. |
| 99 | S&F Vertical distribution board double door made out of sheet metal enclosure (CRCA sheet) dust and vermin proof TPN 4 way with suitable copper bus bar neutral bar, earth bar IP 43 protection, Triple pole and neutral 415 volts, flush to wall / fixed on surface incl making good of surface and provision for (modular/MCCB) incomer and SP/TP MCBs outgoing for each phase complete all as specified and directed |
| 100 | S&F distribution board double door made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 8 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 240 volts, flush to wall / fixed on surface incl making good of surface complete all as specified and directed |
| 101 | S&F 4 pole MCCB 125 Amp 24, 50 Hz, 415V with rupturing capacity 16KA for fixing in existing LT panel capacity complete all as specified and directed |
| 102 | S&F MCB single pole, 6 to 32 Amp 240 volt C curve 10 KA breaking capacity complete all as specified and directed |
| 103 | S&F MCB SPN 40 to 63 Amps,10 KA, 240 volt C curve IP 20 complete all as specified and directed |
| 104 | Taking down old u/s any type PVC sheathed in service connections cable of any sizes complete all as specified & directed. (From DB to LT panel) |
| 105 | S&F Cross linked poly ethylene (XLPE) LT cable XLPE insulated, PVC inner sheathed bedded galvanised steel strip or wire armoured heavy duty 1100 volt grade with stranded aluminium conductor having cross sectional area 35 sqmm 4 core and confirming to IS -7098(Part-I 1988 as per latest amendments), fixing on wall with saddle /ducts/through pipes complete all as specified and directed. |
| 106 | S & F Rigid non-metallic PVC conduit 20 mm dia for telephone cable exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. complete all as specified and directed |
| 107 | Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing wire of size 4 mm dia by means of GI bolts/nuts/washers and protected by 15 mm bore GI light grade pipe upto test point or upto main switch board fixing with 02 Nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embedded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and as directed by Engineer-in-charge. |
| 108 | Supply and fix switch piano flush type 5 Amps all as specified and directed . |
| 109 | Supply and fix bell push 6 Amps one module all as specified and directed |
| 110 | Supply and fix socket 5 amp flush type complete all as specified and directed. |
| 111 | S&F batten holder 230 volt all as specified and directed . |
| 112 | S & F LED bulb of 15 watt complete all as specified and directed. |
| 113 | M&L for calling bell AC 230 volt , 50 Hz complete all as specified and directed. |
| 114 | S & F socket 5 pin 16/6 Amp flush type complete all as specified and directed. |
| 115 | S & F switch 15/16 Amps complete all as specified and directed. |
| 116 | S & F LED building security light fitting 30/35 watts made of pressure diecast aluminium housing with acrylic cover as diffuser with IP65 and IK -07 protection , THD<10%, lumen output >= 110 lumen per watts with integrated electronic driver incl copper connecting wire three core of suitable size upto connector of ceiling rose complete incl GI mounting pipe of building security lights of size 32 mm to 40 mm size upto 1.2 mtr length bend into sizes incl mounting clamps made of MS flat saddles, nut bolt and washers all as specified and directed |
| 117 | S&F distribution board double door made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 4 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 250 volts, flush to wall / fixed on surface incl making good of surface complete all as specified and directed |
| 118 | Deduct Credit for Demolished/Dismantled material Rs (-) 36,552.44 (Minus) as listed in Schedule 'A' Part-II (Credit Schedule)Note : Tenderers will not quote against this item being a tentative amount, to be considered to arrive at the 'Contract Sum'. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysSep 11, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender