Defence Statutory Bodies & Commissions/Committees Closing in 18 days TDR #57100963

Tender For Repair/Replacement To Flooring, Plastering, Joinery, Galvalume Sheets, False Ceiling, Int/Ext Periodical Services And Other Misc B/R Works In Otm Accn Of 226 Supply Depot Under Age B/R-I Of Ge (North) Delhi Cantt-10

Issued by Statutory Bodies & Commissions/Committees · New Delhi, Delhi
Tender Value
45 Lakhs
Estimated cost
Bid Submission
09 Sep 2026
18 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Replacement To Flooring, Plastering, Joinery, Galvalume Sheets, False Ceiling, Int/Ext Periodical Services And Other Misc B/R Works In Otm Accn Of 226 Supply Depot Under Age B/R-I Of Ge (North) Delhi Cantt-10

BOQ

Name of Work:- REPAIR/REPLACEMENT TO FLOORING, PLASTERING, JOINERY, GALVALUME SHEETS, FALSE CEILING, INT/EXT PERIODICAL SERVICES AND OTHER MISC B/R WORKS IN OTM ACCN OF 226 SUPPLY DEPOT UNDER AGE B/R-I OF GE (NORTH) DELHI CANTT-10
Sl. No. Item Description
1Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc 1.50 sqm eachand n exc 4 sqm and removing from site,complete all as specified and directed.
2Supply and fix Aluminium door with powder coated standard aluminium sections of medium size and weight not less than 1.50 Kg/Rm and conforming to catalogue of Jindal or equivalent. The door shall be of side hung type fixed at bottom with standard floor door spring, pintals etc. The bottom panel of the door shall be fitted with 12 mm thick prelaminated particle board decorated on both sides of approved colour and 5.0 mm thick tinted glass in top panel complete including all necessary fittings such as 02 Nos handles of approved size and shape, 02 Nos Aluminium anodised tower bolts 200 mm long and 01 No mortice lock per shutter. The shutter frame shall be with one or more rebates including jointing cleats, glazing clips, standard rubber beading complete all as specified and directed.Note:- Floor door spring shall be measured and paid separately under relvant items of these schedule.
3S&F Double action floor spring hydraulically regulated made up of min 1.25mm thick stainless steel foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty suitable for toughen glass shutters complete.
4Taking down PVC door shutter with PVC chowkats including all fittings area exc 1.00 Sqm but n.exc 2.00 Sqm all as directed.
5S&F Factory made solid PVC door frame (chowkhat) of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, S&F in opening as per specification & drg as per manufacturer instrutions.
6S&F factory made PVC solid panel door shutter 30mm thick (style) connecting of frame made out of MS tube for top and bottom rail. MS frame shall be coverd withheat moulded plain coour PVC 'C' channel having a PVC sheet strips of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail of either side and as gap insert for toprail and bottom rail panellinn of plain colour PVC to be fitted in the ms frame welded/ sealed in the stiles and rail with suitable PVC sheet and loading and jointed together with solvent cement, supplying and fixing in the frame at site all as directed by Engineer -in -charge.
7S&F butt hinges, 100 mm size medium weight, cold rolled mild steel complete
8S&F 150 mm size Aluminium anodised,barrel tower bolts of extruded section and fixed
9S&F 150 mm size Extruded aluminium alloy handles, fabricated type, anodised
10S&F Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed
11Dismantling of AC sheet / CGI sheet roof corrugated/semi corrugated of any description including ridges/gutters etc at height upto 15 mtr complete all as specified and directed.
12Dismantling wrought iron or mild steel work of any description not otherwise provided for .
13Dismantling of wall and ceiling boards any thickness including cover fillets, grid work complete as required and directed.
14S&F structural steel work for rolled sections as in main and cross beams, hips and jack rafters, purlins, running rails and guides for sliding doors, fixed with angles and angle cleats or other connecting plates gde Fe-410-W at any height complete all as spd and directed.
15S&F of 0.50mm thick (including coated thickness) pre-colour pre- profiled (Galvalume/zinkalume) corrugated/plain sheets of required colour and design having tensile strength of 550 Mpa as in roof sheeting/sunshade/ wall cladding, north light curves, fixed with zinc coated self drilling fastener including EPDM washer complete laid with one corrugation side laps and min 150mm end lap laid to slope all as per manufacturer / profile maker instruction complete all as specified and as directed.
16S&F 2mm thick fibre glass reinforced translucent corrugated/plain sheetings with two corrugations side lap fixed with coach screw and washer in roof, wall etc complete all as specified and directed.
17S&F in repair for Gypsum ceiling board for ceiling prepainted, perforated finish, 600 x 600 x 9 to 9.5mm thick in size, of approved brand/make, laid over and including grid work of size 600 x 600mm, made out of 0.5mm thick G.I. tee 32 x 24 mm for main, 25x24mm for cross tee and 20 x 20mm angle fixed on wall, powder coated finish on exposed faces of tee and angle. hung from ceiling using 2 mm thick G.I. Suspension wires spaced at 1200 mm on main runners including making niches for fans/light complete all as specified and directed.
18S&F in repairs false ceiling at all heights with GRG (Glass fibre Reinforced Gypsum) false ceiling tiles of size 595x595mm of approved texture, design and patterns having moisture content less than 2% humidity resistance of 99% NRCO.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 476 (part 4)-1970 and light reflectance of 85% (min) to be laid in true horizontal level suspended on inter locking metal T-grid of hot dipped galvanized iron section of 0.33mm thick ( galvanized @ 12a grams per sqm incl both sides ) comprising of main T runners of size 15x32mm of length 3000mm, cross T of size 15x32mm of length 1200mm and secondary intermediate cross T of size 15x32mm of length 600mm to form grid module of size 600x600mm, suspended from ceiling usung galvanized mild steel items (galvanizing @ 80 grams per Sqm) ie 50mm long 8mm outer diater M-6 dash fasteners 6mm dia fully threaded hanger rod upto 1000mm length and L shape level adjuster of size 85x25x2mm galvanised iron perimeter wall angle of size 24x24x0.40mm of length 3000mm to be fixed on periphery wall / partition with the help
19M&L for E-board tiles ceiling on GI powder coated channel/Tee/Grid of make (Armstrong or equivalent) frame work with the following specifiecation including cutting holes in brick wall built in cement mortar & making good in cement concrete 1:2:4 type B0/Cement mortar 1:3 complete all as specified and directed with following:-(a) M&L Plugging to wall around the rooms & supplying & fixing GI powder coated angle of make (Armstrong or equivalent) of size 25x25mm.(b) S&F 1.60 mm dia GI wire suspenders with adjustable clamps including fixing to ceiling with dash free fasteners.(c) S&F GI powder coated tee as in main & cross members at 595 mm centre to centre supported suspenders alongwith adjustable clamp to maintain level.(d) S&F E-board ceiling tiles of size 595 mm x 595mm x 4mm thickness, confirming to relevant IS in squares of GI powder coated tee with clips made to shape, shade and pattern of tiles shall be as approved by GE.
20S&F PVC sheet wall lining consisting of 5mm thick colour / printed PVC sheet inclusive of solvent cement and fixing at site including PVC frame as per specifications, complete all as specified and directed.
21Preparation of newly steel surfaces, of any description, over 10 cm width or girth, and applying two coats of synthetic enamel paint over a coat of red oxide complete complete all as specified and as directed.
22Hacking out old broken glass (any thickness, size , quality or description) from metal frame including punching or drilling out old glazing pins/ spring clips, nut bolts & fillets at ht upto 15 mtr complete all as specified and directed.
23S&F for MS work in Bands, straps, supports or stays for RWP, ventilating pipes, gutters including bolts, if reqd hooks (stay), clamps, holdfasts, wall ties, nosing angles, hooks for hanging fans and similar small articles conforming to Fe-290 gde E-165 hight up to 15 mtrs
24S&F sheet glass ordinary quality, 3 mm thick and glazing with oil putty in square n.exc. 0.5 Sqm in each pane at ht upto 15 mtr complete all as specified and directed.
25Demolition of Brickwork or stone/ boulders masonry built in cement or cement lime mortar incl all quions, arches, pillars, etc but excluding ashlar facing, dressed stone work and precast concrete articles complete all as specified and directed.
26Material and labour for Brick work with sub class B bricks of old size, straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6 complete all as specified and directed.
27Taking down cement plaster of any description & thickness from brick/concrete sufaces of wall/ceiling etc including racking out joints, hacking for keys scrubbing down with water etc. complete all as specified and directed.
28M&L for rendering 10 mm thick in CM ( 1:6 ) on wall/ concrete surfaces finish even and smooth without using extra cement complete all as specified and directed.
29M&L for rendering 15 mm thick in CM ( 1:4 ) on wall/ concrete surfaces finish even and smooth without using extra cement using WPC compound at any description with necessary scaffolding of any height bldgs etc complete all as specified and directed.Note:WPC shall be measured and paid separetly)
30M&L for 5mm thick plaster on ceiling in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and as directed .
31Supply only Liquid water proofing compound complete all as spesified and directed.
32M&L for preparation of wall surfaces and applying waterproof cement based putty, one coat primer and two coats Oil Bound Distemper by Airless Spray Technology on new/old plastered wall surfaces complete all as specified and directed.Preparing new or old plastered/previously painted wall surfaces by scrapping and mechanical sanding to obtain an even, smooth and dust-free surface and applying waterproof cement based wall putty of approved make @ 1.00 Kg per Sqm (undiluted) for average thickness of 1 mm, followed by one coat of alkali resistant water-based wall primer and two coats of Oil Bound Distemper by fully automatic airless spray application complete.The work shall comprise the following operations:-Surface preparation including removal of loose particles, scrapping of old painted surfaces wherever required and mechanical sanding using wall sander having speed between 1500 and 2700 RPM with inbuilt vacuum dust extraction system and sanding pads of minimum 240 grit and 7\\"/9\\" diameter or equivalent approved equipment. Mixing of waterproof cement based putty by adding 40% to 50% clean water using mechanical putty mixer having minimum 1400 W power and capable of mixing not less than 2.5 Kg of putty per minute. Applying waterproof cement based wall putty by fully automatic airless spray machine having minimum 3.30 KW DC electric motor, maximum flow rate of 6 litres per minute, working pressure not less than 230 bar and tip size up to 0.041 inch or equivalent approved equipment, to achieve an average thickness of 1 mm and consumption of 1 Kg per Sqm. Allowing the putty surface to dry for 6 to 8 hours and carrying out mechanical sanding using vacuum-assisted wall sander to achieve a smooth and uniform finish free from dust and surface imperfections. Applying one coat of alkali resistant water-based wall primer over the prepared putty surface by airless spray machine complete, ensuring uniform coverage and manufacturer's recommended spreading rate. Applying two coats of Oil Bound Distemper over the primed surface by Airless Spray Technology using airless spray machine having maximum working pressure of 3300 PSI or higher, capable of operating a single spray gun with material hose length up to 30 metres and suitable extension accessories for hard-to-reach locations to ensure uniform penetration and superior finish with minimum wastage and manpower. The airless spray machine shall be of reputed make and shall be equipped with ProGuard or equivalent technology, pressure monitoring system and paint usage tracking facility and shall be certified or recommended by the paint manufacturer for application of wall finishes. The rate quoted shall include all labour, materials, scaffolding, mechanical sanding equipment with dust extraction system, airless spray machines, hoses, spray guns, mixers, primers, putty, Oil Bound Distemper, consumables and all incidental charges necessary for complete execution of the work.
33M&L for preparing new surfaces of wall and applying two coats of white wash on ceiling and cornices complete all as specified and directed.
34M&L for preparation of new plastered surfaces of wall and applying two or more coat of 100% Premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489;2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 sm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm using auto-roller and airless paint sprayer complete all as specifiec and as directed.
35M&L for two coats of cement base paint on new plastered surface of wall using auto-roller and airless paint sprayer over one coat of acrylic water based interior grade primer @ 0.8 ltr (undiluted)/10 sq mtrs diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine of paint application of asian Paints Trucare graco or equivalent having an electric motor of min. 1 HP with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface for painting of subsequent quotes complete all as specifiec and as directed.
36S&F in repair steel rolling shutters, without ball bearing as specified including top covers anchoring rod, hasp & staple and one shop coat of red oxide primer gear operated type with bevel gear box and crank handle and errected in position complete thickness of laths 1.25mm complete all as specified and directed.
37S&F for ball bearing for rolling shutters all as specified and directed.
38S&F in repairs 1.25 mm thick laths in any type of rolling shutter and in any length complete all as specified and directed.
39M&L for APP modified roof treatment over existing accessible RCC roof slab / chajjah / canopy / parapet wall with following specification complete all as specified and directed :-(a) Removing of existing water proofing membrane, damage plaster, vegitation/plants, PCC any thickness, Tar-felt, loose particles and all forgin materials over the roof and shifting the debris from site to out-side area as directed by authority on factory garbage area. (b) removing and Cleaning existing damaged APP membrane from roof surface and clean all cement mortar and vegitation, plants with roots properly.(c) Applying oil bound bitumen primer @ 0.40 Kg/Sqm over 10mm thick plastering in CM (1:4) with WPC @ 3% by weight of the cement.(d) Apply a coat of hot bitumen 85/25 grade @ 1.60 kg/sqm.(e) Apply standard quality APP modified polymeric memrane minimum 3mm thick over the bitumen coat joints to be touched hot and width of overlaps shall e 75 mm length wise and 100mm widthwise of the membrane.(f) APP membrane shall be laid using butane torch by Torch application with minimum 10cm side overlap and 15cm end lap.(g) Top of membrane shall be provide with solar reflective bituminous aluminum paint @ 0.1 Kg/Sqm as prescribed by manufacture of membrane.
40Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar; barred iron doors; ladder; framed balusters; railing;frame work for water tanks and similar work conforming to Fe 290. Gde-E-165 all as specified .
41M&L in repair for 60mm thick machine pressed precast concrete interlocking paver block (glossy finish) of M-35 Gde of approved shape, size and colour conferming to IS 15658-2006 and laid over and including 25mm sand cushion and demolition of interlocking paver blocks complete all as specified and as directed.
42S&F in repair for precast cement concrete type B-1 (1:2:4)(20mm graded stone aggregate ) as in kerb and edging to road and footh path, etc including chamfered,weathering, throating etc and setting in CM (1:4) c complete all as specified and as directed.
43M&L for preparation of wall surfaces and applying waterproof cement based putty, one coat primer and two coats Oil Bound Distemper by Airless Spray Technology on new/old plastered wall surfaces complete all as specified and directed. Preparing new or old plastered/previously painted wall surfaces by scrapping and mechanical sanding to obtain an even, smooth and dust-free surface and applying waterproof cement based wall putty of approved make @ 1.00 Kg per Sqm (undiluted) for average thickness of 1 mm, followed by one coat of alkali resistant water-based wall primer and two coats of Oil Bound Distemper by fully automatic airless spray application complete.The work shall comprise the following operations:-Surface preparation including removal of loose particles, scrapping of old painted surfaces wherever required and mechanical sanding using wall sander having speed between 1500 and 2700 RPM with inbuilt vacuum dust extraction system and sanding pads of minimum 240 grit and 7\\"/9\\" diameter or equivalent approved equipment. Mixing of waterproof cement based putty by adding 40% to 50% clean water using mechanical putty mixer having minimum 1400 W power and capable of mixing not less than 2.5 Kg of putty per minute. Applying waterproof cement based wall putty by fully automatic airless spray machine having minimum 3.30 KW DC electric motor, maximum flow rate of 6 litres per minute, working pressure not less than 230 bar and tip size up to 0.041 inch or equivalent approved equipment, to achieve an average thickness of 1 mm and consumption of 1 Kg per Sqm. Allowing the putty surface to dry for 6 to 8 hours and carrying out mechanical sanding using vacuum-assisted wall sander to achieve a smooth and uniform finish free from dust and surface imperfections. Applying one coat of alkali resistant water-based wall primer over the prepared putty surface by airless spray machine complete, ensuring uniform coverage and manufacturer's recommended spreading rate. Applying two coats of Oil Bound Distemper over the primed surface by Airless Spray Technology using airless spray machine having maximum working pressure of 3300 PSI or higher, capable of operating a single spray gun with material hose length up to 30 metres and suitable extension accessories for hard-to-reach locations to ensure uniform penetration and superior finish with minimum wastage and manpower. The airless spray machine shall be of reputed make and shall be equipped with ProGuard or equivalent technology, pressure monitoring system and paint usage tracking facility and shall be certified or recommended by the paint manufacturer for application of wall finishes. The rate quoted shall include all labour, materials, scaffolding, mechanical sanding equipment with dust extraction system, airless spray machines, hoses, spray guns, mixers, primers, putty, Oil Bound Distemper, consumables and all incidental charges necessary for complete execution of the work.
44M&L for preparation of old plastered surfaces of wall and applying two or more coat of 100% Premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489;2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 sm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm using auto-roller and airless paint sprayer incl Complete removing of existing treatment by scrapping with Asian Paints TruCare Wall Sander: L- 01/H-01 (having mechanical vacuum mechanism) or equivalent having RPM not less than 1500, sanding pad of 80 Grit having dia of 7\\" to 9\\" to make the surface free from dust, loose paint etc. by skilled labour complete all as specifiec and as directed.
45M&L for three coat of white wash on old surface on ceiling including preparation of surface complete all as specified and directed.
46M&L for two coats of cement base paint on old plastered/unplastered surface of wall using auto-roller and airless paint sprayer over one coat of acrylic water based interior grade primer @ 0.8 ltr (undiluted)/10 sq mtrs diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine of paint application of asian Paints Trucare graco or equivalent having an electric motor of min. 1 HP with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface for painting of subsequent quotes incl Complete removing of existing treatment by scrapping with Asian Paints TruCare Wall Sander: L- 01/H-01 (having mechanical vacuum mechanism) or equivalent having RPM not less than 1500, sanding pad of 80 Grit having dia of 7\\" to 9\\" to make the surface free from dust, loose paint etc. by skilled labour complete all as specifiec and as directed.
47Complete removal of existing treatment and applying two coat of synthetic enamel paint on wooden surfaces of any description over 10 cm width or girth complete all as specified and as directed.
48Complete removal of existing treatment and applying two coats of synthetic enamel paint on steel surfaces of any description over 10 cm width or girth complete all as specified and as directed.
49S& F in repair Rotational moulded Polyethylene water storage tank 500 liters capacity (cylidrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I incl brass float valve 20mm dia and dismantling water tank.
50S&F in repairs rotational moulded plythene water storage tank multilayer of capacity 1000 ltr hoisted and fixed position all as specified in SSR Part I.
51Cleaning and removing all dirts and scales from service water tanks and from mouth of circulating pipes etc capacity of tank exceeding 250 ltr but not exceeding 500 ltr complete all as specified and directed.
52All as per the description of srl item No 51 above but exceeding 500 ltr but not exceeding 1000 ltr capacity complete all as specified and directed.
53Taking up or down 15 mm dia old serviceable / unserviceable steel tubing any grade and connections cleaning for re-fixing or removal to store complete all as specified and directed .
54All as per the description of srl item No 513 above but 20mm bore complete all as specified and as directed.
55S&F steel tubing medium grade ,galvanized with all fitting such as bend ,elbow, socket,tees,and fixed complete to wall or in ceiling or in floors including cutting threading and making forged bends on pipes MS hooks etc ,for 15mm bore pipes complete all as specified and as directed.
56All as per the description of srl item No 55 above but 20mm bore complete all as specified and as directed.
57Supply, laying and fixing of 20mm outer dia of CPVC pipe SDR 11 and plain CPVC SDR 11 fittings on wall/ceiling or laying in floors complete including brass CPVC fittings (i.e elbow, Tee, MTA/MBTA,FTA/FBTA, Tank adaptor, Union, etc suitable for 15mm bore bath fittings). Note- length of pipe with fittings to be measured for payment, no extra payment should be made for fittings).
58Supply and laying of 25mm outer dia of CPVC pipe SDR 11 and plain CPVC SDR 11 fittings on wall/ceiling or laying in floors complete including brass CPVC fittings (i.e elbow, Tee, MTA/MBTA,FTA/FBTA, Tank adaptor, Union, etc).Note- length of pipe with fittings to be measured for payment, no extra payment should be made for fittings).
59S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls or in floor 75mm bore including demolition/taking down PVC/ drain/Rain water pipe complete.
60S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls 110 mm bore including demolition/taking down PVC/ drain/Rain water pipe complete.
61S&F PVC (SWR) bends with access door any radius, 75 mm bore, complete.
62S&F PVC (SWR) bends with access door any radius, 110 mm bore, complete.
63S&F PVC (SWR) branch piece equal or unequal of 110mm bore complete
64S&F PVC (SWR) branch piece equal or unequal of 75mm bore complete
65Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing), and rubbish off the premises complete all as specified and directed.
66M&L for virified ceramic coloured tiles 8 to 10 mm thick (square / recetangular ) polished, area of each tiles not exc 0.36 sqm, in floors etc, over 15mm thick screed bed in cement mortar 1:6 set and jointed in neat cement slurry and pointed in coloured cement.including dismantling floor, hearth or wall tiling including cement mortar bedding all as specified and directed.
67Ditto- as per item No 69 but in vertical surface as skirting, dado and risers to steps over and including10 mm thick rendering/backing coat in cement mortar 1:4 etc.
68M&L for non skid ceramic coloured tiles 7 to 8 mm thick joint free area of each tile exceeding 0.09 sqm but not exceeding 0.18 sqm as in floors over 15mm thick screed bed in cement mortar 1:6 set and jointed in neat cement slurry and pointed in coloured cement.including dismantling floor, hearth or wall tiling including cement mortar bedding removing serviceable tiles to store and rubbish off the premises all as specified and directed.
69M&L glazed ceramic coloured tiles in vertical surface 350x250x7mm / 450x350x7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match incl backing coat 10mm thick in CM (1:4) and finished rough, complete including dismantling wall tiling including cement mortar bedding (but not backing), all as specified & directed.
70M&L 18 to 20 mm thick pre-polished machine cut Kota stone slab as in flooring over and including 15mm thick screed bed in cement mortar 1:6, laid over cement slurry @ 3 Kg/Sqm and jointed with grey cement slurry mixed with pigment to match with shade of slab including molding the edge of slab and dismantling of old kota stone slabs including molding the edge complete all as specified and as directed.
71M&L 18 to 20 mm thick pre-polished machine cut Kota stone slab as in riser or vertical surface over and including 10 mm thick rendering in cement mortar 1:4, and jointed with grey cement slurry mixed with pigment to match with shade of slab including molding the edge of slab and dismantling of old kota stone slabs including molding the edge Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57100963
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 45 Lakhs
LAST DATE 09-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Replacement To Flooring, Plastering, Joinery, Galvalume Sheets, False Ceiling, Int/Ext Periodical Services And Other Misc B/R Works In Otm Accn Of 226 Supply Depot Under Age B/R-I Of Ge (North) Delhi Cantt-10
Basic Detail
Tender No GE/NORTH-112/2026-27
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 19 Aug 2026
Submission Date 09 Sep 2026
Open Date 12 Sep 2026
Finance
Tender Value 45 Lakhs
Tender Fee 500
EMD 90000
Exemption Available
Document List
2b122d35-8cc1-4152-b204-d18938fb93f6.html
BOQ_880004.xls
Gen112.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Sep 12, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
html

2b122d35-8cc1-4152-b204-d18938fb93f6.html

xls

BOQ_880004.xls

pdf

Gen112.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender