Tender For Special Structural Repair And Retrofitting Work In Rajasthan High Court Building, Jodhpur (Electrical Works)
Tender Overview
Project Description
Tender for Special Structural Repair And Retrofitting Work In Rajasthan High Court Building, Jodhpur (Electrical Works)
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 21-Aug-2026 | Corrigendum | Other | 27-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Note : The Rates of all BOQ items are Exculsive of GST. GST shall be paid separately @18%, or as applicable |
| 2 | S&F following sizes of ISI marked ( IS:14927 P - II ) uPVC trunking along with accessories like coupler, inner, outer, elbow, square box, tee, end cap etc. on surface with screws, expansion fasteners etc. as required. |
| 3 | 20 mm x 12 mm |
| 4 | 25 mm x 12 mm |
| 5 | 32 mm x 12 mm |
| 6 | Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) with CM/L no. printed and made out of unbreakable and fire retardant virgin UV Stabilized Polycarbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating ,minimum width of switch toggle( PUSH PART ) should not less then 20mm, including making connections, testing etc as required. |
| 7 | 10 A one way switch |
| 8 | 16 A one way switch 1M |
| 9 | 16 Amp. 2 Module switch With Led Indicator |
| 10 | 32 Amp. 2 Module switch With Led Indicator |
| 11 | Providing & Fixing of IS:1293 marked modular type lockable feature socket with CM/L no. printed duly made out of unbreakable and fire retardant virgin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating, including making connections, testing etc as required. |
| 12 | 6 A 3 pin shuttered socket |
| 13 | 6/16 A shuttered socket |
| 14 | Providing & Fixing of following size mounting grid plates with cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect. |
| 15 | 1/2 Module |
| 16 | 3 Module |
| 17 | 4 Module |
| 18 | 6 Module |
| 19 | 8 Module |
| 20 | 10 Module |
| 21 | 12 Module |
| 22 | Providing & Fixing of Hot dipped Galvanized metal box of 1.2 mm thick with earthing terminal and adjustable floating clamp in recess/ surface suitable for modular accessories as required. |
| 23 | 1-2 Module |
| 24 | 3 Module |
| 25 | 4-5 Module |
| 26 | 6-8 Module |
| 27 | 10-12 Module |
| 28 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanism , energy limiting of class 3 as per IEC, minimum phase termination capacity of 25 sq.mm., conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating, 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. |
| 29 | Single pole MCB (With B / C curve tripping characteristics) |
| 30 | 6 A to 32 A rating |
| 31 | Double pole MCB (With B / C curve tripping characteristics) |
| 32 | 40 A rating |
| 33 | 50/63 A rating |
| 34 | Triple pole MCB (With B / C curve tripping characteristics) |
| 35 | 40 A rating |
| 36 | 50/63 A rating |
| 37 | Four pole MCB (With B / C curve tripping characteristics) |
| 38 | 50/63 A rating |
| 39 | 80 A rating |
| 40 | Providing & Fixing of 240/415 V factory fitted RCBO with overload, short-circuit and earth leakage protection with ISI marked (IS12640-2)/ conforming to IEC 61009-1, breaking capacity 10 KA, provision for pad lock, min. Electrical operation 10,000 upto 63 A rating , minimum phase termination capacity of 25 sq.mm. , IP 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required. |
| 41 | Two pole 100/300mA sensitivity |
| 42 | 63 A rating |
| 43 | Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door (Metal / Glazed / Acrylic) Distribution board with Metal end box made out from Galvanized steel / CRCA sheet, powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, complete with 100 amp. insulated copper bus bar/shorting link , brass neutral link with shrouds, brass earth link , door earthing arrangement, color coded interconnecting wire set of minimum 10.0 sqmm size and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. |
| 44 | Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box |
| 45 | 6Way {8 Incomer + 6 Sub Incomer (2+2+2) + 18 out going } |
| 46 | 8Way. {8 Incomer + 6 Sub Incomer (2+2+2) + 24 out going } |
| 47 | Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for 3/4 pole MCCB and SP / TP MCB up to 63 Amps. as outgoing ,made out from Galvanized steel / CRCA sheet , powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. complete with insulated 125/160/200/250 Amp. copper bus bar, brass neutral bars with shrouds, brass earth bar , color coded interconnecting wire set of suitable rating and din bar, door earthing arrangement, masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. |
| 48 | Double door IP-43 & IK-09 with Provision of Incomer MCCB up to 125 A Rating with Metal end box |
| 49 | 4 Way |
| 50 | 6 Way |
| 51 | Providing & Fixing of modular type 100W Step Fan regulator duly ISI marked (IS 11037) with CM/L no. printed made out of unbreakable and fire retardant virgin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , including making connections, testing etc as required. |
| 52 | 5 step fan regulator 2 Module |
| 53 | Providing & Fixing of following modular accessories, made out of unbreakable and fire retardant virgin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating, including making connections, testing etc as required. |
| 54 | Blanking plate |
| 55 | Modular MCB 6 A to 32 A DP |
| 56 | Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as required complete in all respect. . |
| 57 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level |
| 58 | 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 59 | Plaster on new surface on wall in cement sand mortar 1:4 including racking of joints etc. complete fine finish : |
| 60 | 20mm thick |
| 61 | Gravelling of Transformer / RMU Yard with 100 mm Height Gravels of Size 20 to 25 mm including leveling, Dressing etc. as Required. |
| 62 | Supplying and drawing FRLS PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR And Also Following the guideline of Fire Safty Audit Report Issue By CE PWD Jodhpur |
| 63 | 3x 1.5 sq.mm |
| 64 | 2 x 2.5 sq. mm. + 1x1.5sqmm |
| 65 | 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. |
| 66 | 2 x 6.0 sq. mm. + 1 x 4.0 sq. mm. |
| 67 | 4 x 6.0 sq.mm |
| 68 | S&F following sizes (dia.) of ISI marked virgin material HMS fire-retardant heavy-duty ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR And Also Following the guideline of Fire Safty Audit Report Issue By CE PWD Jodhpur |
| 69 | 20 mm |
| 70 | 25 mm |
| 71 | 32 mm |
| 72 | Removing /removing and refixing of Electric Accessories Like Ceiling fan, Exaust fan, Wall Fan, Down light, Tubelight, 2x2 Panel Light, And Other Items Which Is not Included But Connetced At Site and Refixing With Good and Running Condition With Issue Safty Certificate as per requirement. With Properly Removed Before Renovation work Start. And Deposite Under Own Custody, After Finishing All Renovation work Of Court Block (Like Court Room , Chambers, Offices, Corridors, section office, registry office and common area etc ) Refixing All Removed Articals And Making In Workable Condition As Before of Removing All These Accessories. All Works Done As Per IS, NBC And PWD Specification. |
| 73 | Dismentaling of Electric Accessories Like Ceiling Rose,Switch, Plug Point , MS Switch box, Switch Plate, Conduiting(PVC/MS),Wire Etc With Properly Removed Before Renovation work Start. And Deposite Under Own Custody, After Finishing All Renovation work Of Court Block (Like Court Room , Chambers, Offices, Corridors , section office, registry office and common area etc ) Refixing All Removed Articals And Making In Workable Condition As Before of Removing All These Accessories. All Works Done As Per IS, NBC And PWD Specification. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 3 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender