Power Government Departments Closing in 4 days TDR #57099446

Tender For Supply, Installation, Testing and Commissioning For Thickening Of 33Kv Batote-Patnitop Line From 100Mm2 Dog Conductor To 150Mm2 Wolf Conductor, Re-Aligment/ Shifting Of 33Kv Batote-Patnitop Line At Rakhjarog Area And Rev Ing/Stablisation O

Issued by Government Departments · Udhampur, Jammu and Kashmir
Tender Value
Ref. Documents
Estimated cost
Bid Submission
25 Aug 2026
4 days left
EMD
4.54 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Udhampur → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Supply, Installation, Testing and Commissioning For Thickening Of 33Kv Batote-Patnitop Line From 100Mm2 Dog Conductor To 150Mm2 Wolf Conductor, Re-Aligment/ Shifting Of 33Kv Batote-Patnitop Line At Rakhjarog Area And Rev Ing/Stablisation Of 6.3Mva Receiving Station Patnitop For Smooth Power Supply. Important Note : All Allied And Associated Works Required For Successful Execution Of Above Items Of Works Including Testing And Energisation , Specifically Mentioned Or Not In Above Description But Required At Site Shall Be Deemed To Be Included And Covered In The Quoted Rates.Scheme Code : Important Note : All Allied And Associated Works Required For Successful Execution Of Above Items Of Works Including Testing And Energisation , Specifically Mentioned Or Not In Above Description But Required At Site Shall Be Deemed To Be Included And Covered In The Quoted Rates.

BOQ

Name of Work:- SITC For thickening of 33KV Batote-Patnitop line from 100mm2 Dog conductor to 150mm2 wolf conductor, Re-aligment/ Shifting of 33KV Batote-Patnitop line at RakhJarog area and Rev ing/Stablisation of 6.3MVA Receiving station Patnitop for smooth Power supply. Important Note : All allied and associated works required for successful execution of above items of works including testing and energisation , specifically mentioned or not in above description but required at site shall be deemed to be included and covered in the quoted rates.Scheme Code : Important Note : All allied and associated works required for successful execution of above items of works including testing and energisation , specifically mentioned or not in above description but required at site shall be deemed to be included and covered in the quoted rates.
Sl. No. Item Description
1Survey, Supply, Installation , Testing and Commissioning for 33 kV Line BAY (LILO) of existing Patnitop-Champa (Batote) Line
2Supply, Transportation, Erection of 11 Mtr LongST Poles (ST410-SP56) including excavation of pit and back filling of soil & consolidating by ramming, watering etc.
3Supply, Transportation, Erection of 9 Mtr LongST Poles (ST410-SP33) including excavation of pit and back filling of soil & consolidating by ramming, watering etc.
4GI V cross-arm with top bracket including clamp
5150mm2 ACSR Conductor
6Channel iron Cross arm(100x50x6)mm 10 feet long
7Angle iron braces (65x65x6)mm 12 feet long
8Angle iron belt (65x65x6)mm 8 feet long
9FI Clamps
10FI Ties
11PG clamps for 100mm2 ACSR Dog conductor
1233kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
1333kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
1433KV Disc Fitting for 150mm2 ACSR Wolf Conductor
15Galvinized Nuts and Bolts
16Danger Plates
17Anti-Climbing Device with Clamps
18Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5mtr long through GI Strip.
19Red Oxide
20Aluminium Paint
21Cement bottoming 1:2:4 mix as per REC standards .6cum/pole
22Aluminium Jointing sleeves
23Galvanised Stay Set with 50 x 8 mm stay clamp, guy insulator(2Nos.), anchor plate (300x 300 x 8 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI stranded wire complete
24Guard netting
25Dismantling of old conductor and write back to divisional store
26Erection of 33KV Isolator with earthing blade (36KV,1250 A, outdoor, 3-poles, 25kA)
27Dismantling of 33KV line at Rakhjarog after shifting and carriage of its material to Sub Division Store
289Mtr Long ST Poles (ST-410-SP56)
29ACSR Conductor Dog
30Channel iron Cross arm(100x50x6)mm 8 feet long
31Angleiron Brace (65x65x6)mm 6ft long
3233KV Polymer composite Disc Insulator 36KV,min failing load 70kN,Lighting Impulse 170kV Positive and 180kV Negative,creepage distance 900mm
3333KV Polymer composite Pin Insulator 36KV,10kN,Lighting Impulse 170kV Positive and 180kV Negative,creepage distance 900mm
34Revamping/Stabilization of (6.3) MVA, 33/11KV Receiving Station Patnitop
3533 KV VCB (36 KV, 1250A, 26.2 KA, Outdoor Type)
3633KV C&R Panel along with O/C, E/F relays, mimic diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-Phase Tri-Vector meter- 5 Amps, DLMS Compliant (SCADA COMPATABILE)
3733 KV Voltage Transformer ( 33 KV/110 v, 1Ø, Multi-Core, Outdoor), (1No. per Ø)
3833 KV Current Transformer ( 33 KV, 1Ø, Multi Ratio Multi-Core, Outdoor), (1No. per Ø)
3933 KV Lightening Arrestors (30 KV, 10 KA, Station class, ZnO, Porcelain/Polymer) gap less
4033 KV Isolator without Earthing Blade ( 36 KV, 1250A, Outdoor, 3 poles, 25 KA)
4111 KV VCB Panel Board (12 KV, 1250A, 25 KA, Outdoor)
4211 KV Isolator, double break, 3-pole, 600 A, horizontal Type, with Earth Switch
4311 KV 3-core 185 mm2 Cable, FRLS
4411 KV Heat Shrinkable Cable Termination Kit ( Indoor)
4511 KV Heat Shrinkable Cable Termination Kit (Outdoor)
4611kV, Gapless Surge Arrestor,9 KV ,10 KA ,LA with Polymer housing, Stn. Type (4/5/6 Sets)
47Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI strip
48Galvanised Iron of sorts
49a) Battery bank 30 Vm 100 AH of 15 No. cells of 2V each, sealed maintenance free VRLA type, High Impact Polyprophelene copolymer container flame retardant. b) 30 V, 100 AH, Float-Cum-Charger with full wave rectification for 220 V, 1 Phase 50 Hz AC Input Supply
5012 Core 2.5 mm2 Control Cable copper Armoured, 1.1 KV Grade ISI, FRLS
516 Core 2.5 mm2 Control Cable copper Armoured, 1.1 KV Grade ISI, FRLS
522 Core 2.5 mm2 Control Cable copper Armoured, 1.1 KV Grade ISI, FRLS
53Lugs, Ferrules etc.
54200 mm2 ACSR Conducttor Panther
55T Clamps
56Polymeric composite Disc Insulator 36KV, Lightening Impulse 170kV Positive and 180kV Negative, creepage distance 900mm,min failing load 70kN
57Rubber Mat 1mx2m 19mm thick
58Fire Extinguisher Co2 type of 4.5kg capacity of control rool
59Helmet
60Rubber Gloves for 33kv level
61Safety Belt
62Safety Shoes
63Earthing rods (set of 3 rods)
64HV Detector all voltages
65Yard Lightening with 4 NO 9 MTR long ST Poles including 4 No 150 Street Lights with allied accessories
6633 KV Yard Concreting & Metalling
67Painting of All Equpiment structures /Gantry structures installed in the outdoor yard
68BUILDING (Staff Quarter at Receiving Station Patnitop)
69Staff Quarters with Column and Beam structures including Toilet (complete with WC, Washbasin and fittings), electric fittings(fans, LED tubelights, leds powerpoints and other fixtures) White Washing of entire building Complete in all respectsainting of doors and windows etc. Overhead water Storage tanks . Pantry (Note: The Contractor shall submit the building drawing in all respects i.e. structral / architechural prepared by authorised Architect for approval from the dept for execution of works.)
70Survey, Supply, Installation , Testing and Commissioning for 33 kV Line BAY (LILO) of existing Line
71Ceramic glazed tiles Fixing 1st quality ceramic glazed tiles conforming to IS:13753 of minimum thickness 5 mm of approved make like NITCO , ORIENT ,, SOMANY, KAJARIA or equivlant make in all colours , shades except begundy,bottle green , black of any size as approved by Engineer - in - charge in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
72Applying white cement based putty of average thickness 2 mm,of approved brand and manufacture,over the plastered wall surface to prepare the surface even and smooth complete.
73Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade
74New work ( Two or more coats) over and including priming coat with cement primer
75Exterior Finishing Finishing walls with water proofing cement paint of reuired shade
76Repairing of roof ceiling of control room building by way of supply and replacing damaged (approx 5 CGI sheets heavy duty) , repairing of holding hooks and bitumin washers to stop water leakage Complete job. Please Enable Macros to View BoQ information Compatibility Report for DhunaBOQ.xls Run on 10-07-2021 14:05 The following features in this workbook are not supported by earlier versions of Excel. These features may be lost or degraded when you save this workbook in an earlier file format. Significant loss of functionality # of occurrences This workbook contains data in cells outside of the row and column limit of the selected file format. Data beyond 256 (IV) columns by 65,536 rows will not be saved. Formula references to data in this region will return a #REF! error. 6.0 'BoQ1'!L40 'BoQ1'!F40 Any effects on this object will be removed. Any text that overflows the boundaries of this graphic will appear clipped. 3.0 'BoQ1'!A1:II42 Minor loss of fidelity Some formulas in this workbook are linked to other workbooks that are closed. When these formulas are recalculated in earlier versions of Excel without opening the linked workbooks, characters beyond the 255-character limit cannot be returned. 5Defined Names Some cells or styles in this workbook contain formatting that is not supported by the selected file format. These formats will be converted to the closest format available. 14.0

AI Tender Summary

OUR REF NO 57099446
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 25-08-2026
Authority
Authority Name Power Development Department
Work Description Tender for Supply, Installation, Testing and Commissioning For Thickening Of 33Kv Batote-Patnitop Line From 100Mm2 Dog Conductor To 150Mm2 Wolf Conductor, Re-Aligment/ Shifting Of 33Kv Batote-Patnitop Line At Rakhjarog Area And Rev Ing/Stablisation Of 6.3Mva Receiving Station Patnitop For Smooth Power Supply. Important Note : All Allied And Associated Works Required For Successful Execution Of Above Items Of Works Including Testing And Energisation , Specifically Mentioned Or Not In Above Description But Required At Site Shall Be Deemed To Be Included And Covered In The Quoted Rates.Scheme Code : Important Note : All Allied And Associated Works Required For Successful Execution Of Above Items Of Works Including Testing And Energisation , Specifically Mentioned Or Not In Above Description But Required At Site Shall Be Deemed To Be Included And Covered In The Quoted Rates.
Basic Detail
Tender No 19-C OF 2026-27
Bidding Type Tender
Location
City Udhampur
State Jammu and Kashmir
Key Dates
Publish Date 19 Aug 2026
Submission Date 25 Aug 2026
Open Date 27 Aug 2026
Finance
Tender Value Ref. Documents
Tender Fee 5000
EMD 4.54 Lakhs
Exemption Available
Document List
5e3915f8-5c30-43aa-9caf-6681b870fbf9.html
BOQ_1074251.xls
SBDThickeningPatnitop.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Aug 27, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

5e3915f8-5c30-43aa-9caf-6681b870fbf9.html

xls

BOQ_1074251.xls

pdf

SBDThickeningPatnitop.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail