Tender For Laying Of Ht Line And Lt Line At Different Locations In The Jurisdiction Of Electric Division-Iii, Jammu Under Ut Capex Having Scheme Code Pddss2627100487
Tender Value
Ref. Documents
Estimated cost
Bid Submission
11 Sep 2026
19 days left
EMD
60000
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jammu → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Laying Of Ht Line And Lt Line At Different Locations In The Jurisdiction Of Electric Division-Iii, Jammu Under Ut Capex Having Scheme Code Pddss2627100487
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Executive Engineer Electric Division-III , JPDCL Jammu Name of Work : Laying of HT Line and LT Line at different locations in the jurisdiction of Electric Division-III, Jammu under UT Capex having Scheme Code PDDSS2627100487 Contract No: e-NIT No. 39 of 2026-27 dt. 19.08.2026. Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # |
| 2 | Item Description |
| 3 | Laying of 0.100 LT line at Ward no 66 Sharika Vihar Roop Nagar , Jammu Sh. Madan Lal 9086289605 with 120 mm sq LT line ABC on 8 mtrs PCC poles , Janipur approved under UT Capex Budget having scheme PDDSS2627100487 ( Providing/Supplying, Erection/Installation, Testing & commissioning comp Job) |
| 4 | PCC Poles 8 Mtr Long (WL: 200 Kg) |
| 5 | 120 mm sq AB Cable |
| 6 | Tension Clamp |
| 7 | Stright Through Cable Joinkit |
| 8 | Galvanized nuts & Bolts |
| 9 | Danger Plates |
| 10 | Anti Climbing Devices with Clamps |
| 11 | Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm 2.5 mtr long through GI Strip |
| 12 | Stone Pad |
| 13 | Insulating Piercing Connectors |
| 14 | PG Clamps |
| 15 | Laying of 0.120 mtr LT line at Village Seora , Jammu , 7006658670 Smt Veena sharma w/o Rk sharma with 120 mm sq LT line ABC on 8 mtrs PCC poles , approved under UT Capex Budget having scheme PDDSS2627100487 , Canal ( Providing/Supplying, Erection/Installation, Testing & commissioning comp Job) |
| 16 | PCC Poles 8 Mtr Long (WL: 200 Kg) |
| 17 | 120 mm sq AB Cable |
| 18 | Tension Clamp |
| 19 | Stright Through Cable Joinkit |
| 20 | Galvanized nuts & Bolts |
| 21 | Danger Plates |
| 22 | Anti Climbing Devices with Clamps |
| 23 | Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm 2.5 mtr long through GI Strip |
| 24 | Stone Pad |
| 25 | Insulating Piercing Connectors |
| 26 | PG Clamps |
| 27 | Laying of 0.180 LT line at vaski Vihar Bantalab Jammu 8803162910 with 120 mm sq LT line ABC on 8 mtrs PCC poles , approved under UT Capex Budget having scheme PDDSS2627100487 ( Providing/Supplying, Erection/Installation, Testing & commissioning comp Job) |
| 28 | PCC Poles 8 Mtr Long (WL: 200 Kg) |
| 29 | 120 mm sq AB Cable |
| 30 | Tension Clamp |
| 31 | Stright Through Cable Joinkit |
| 32 | Galvanized nuts & Bolts |
| 33 | Danger Plates |
| 34 | Anti Climbing Devices with Clamps |
| 35 | Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm 2.5 mtr long through GI Strip |
| 36 | Stone Pad |
| 37 | Insulating Piercing Connectors |
| 38 | PG Clamps |
| 39 | Laying of 0.060 mtr LT line at w no 1 Priyadrashan Lane Talab tillo for sh. Pawan Kumar 9419789674 with 120 mm sq LT line ABC on 8 mtrs PCC poles , approved under UT Capex Budget having scheme PDDSS2627100487 ( Providing/Supplying, Erection/Installation, Testing & commissioning comp Job) |
| 40 | PCC Poles 8 Mtr Long (WL: 200 Kg) |
| 41 | 120 mm sq AB Cable |
| 42 | Tension Clamp |
| 43 | Stright Through Cable Joinkit |
| 44 | Galvanized nuts & Bolts |
| 45 | Danger Plates |
| 46 | Anti Climbing Devices with Clamps |
| 47 | Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm 2.5 mtr long through GI Strip |
| 48 | Stone Pad |
| 49 | Insulating Piercing Connectors |
| 50 | PG Clamps |
| 51 | Laying of 0.090 mtr LT line at Lower muthi Akalpur road W no m57 8744847211 for sh. sohan Lal with 120 mm sq LT line ABC on 8 mtrs PCC poles , approved under UT Capex Budget having scheme PDDSS2627100487 ( Providing/Supplying, Erection/Installation, Testing & commissioning comp Job) |
| 52 | PCC Poles 8 Mtr Long (WL: 200 Kg) |
| 53 | 120 mm sq AB Cable |
| 54 | Tension Clamp |
| 55 | Stright Through Cable Joinkit |
| 56 | Galvanized nuts & Bolts |
| 57 | Danger Plates |
| 58 | Anti Climbing Devices with Clamps |
| 59 | Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm 2.5 mtr long through GI Strip |
| 60 | Stone Pad |
| 61 | Insulating Piercing Connectors |
| 62 | PG Clamps |
| 63 | Laying of 0.180 mtr LT line at mishriwala , 8492882075 lower muthi sh Sham Lalas/o Surya Verma with 120 mm sq LT line ABC on 8 mtrs PCC poles , approved under UT Capex Budget having scheme PDDSS2627100487 ( Providing/Supplying, Erection/Installation, Testing & commissioning comp Job) |
| 64 | PCC Poles 8 Mtr Long (WL: 200 Kg) |
| 65 | 120 mm sq AB Cable |
| 66 | Tension Clamp |
| 67 | Stright Through Cable Joinkit |
| 68 | Galvanized nuts & Bolts |
| 69 | Danger Plates |
| 70 | Anti Climbing Devices with Clamps |
| 71 | Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm 2.5 mtr long through GI Strip |
| 72 | Stone Pad |
| 73 | Insulating Piercing Connectors |
| 74 | PG Clamps |
| 75 | Galvanized Stay Set with 50X8mm Stay clamp, Guy insulator (2 Nos), anchor plate (200X200X6mm) Nuts & Bolts, 2 nos turn buckles,1.8mm long, 16mm diameter solid GS stay rod and 7/3.15mm dia GI standard wire complete |
| 76 | Laying of 0.100 LT line at Gurha Brahamana Patoli C/O Sh Mohinder Mob no 8167486696 with 120 mm sq LT line ABC on 8 mtrs PCC poles , Janipur approved under UT Capex Budget having scheme PDDSS2627100487 ( Providing/Supplying, Erection/Installation, Testing & commissioning comp Job) |
| 77 | PCC Poles 8 Mtr Long (WL: 200 Kg) |
| 78 | 120 mm sq AB Cable |
| 79 | Tension Clamp |
| 80 | Stright Through Cable Joinkit |
| 81 | Galvanized nuts & Bolts |
| 82 | Danger Plates |
| 83 | Anti Climbing Devices with Clamps |
| 84 | Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm 2.5 mtr long through GI Strip |
| 85 | Stone Pad |
| 86 | Insulating Piercing Connectors |
| 87 | PG Clamps |
| 88 | Laying of 0.150 km LT line at village Jungwari P/O Domana (9070830126) recommended by Hon'ble MLA Sh. Sham sharma AC North on 8 mtrs PCC poles with 120 m Sq AB cable , approved under UT Capex Budget having scheme PDDSS2627100487 ( Providing/Supplying, Erection/Installation, Testing & commissioning comp Job) |
| 89 | PCC Poles 8 Mtr Long (WL: 200 Kg) |
| 90 | 120 mm sq AB Cable |
| 91 | Tension Clamp |
| 92 | Galvanized nuts & Bolts |
| 93 | Danger Plates |
| 94 | Anti Climbing Devices with Clamps |
| 95 | Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm 2.5 mtr long through GI Strip |
| 96 | Stone Pad |
| 97 | Insulating Piercing Connectors |
| 98 | PG Clamps |
| 99 | Galvanized Stay Set with 50X8mm Stay clamp, Guy insulator (2 Nos), anchor plate (200X200X6mm) Nuts & Bolts, 2 nos turn buckles,1.8mm long, 16mm diameter solid GS stay rod and 7/3.15mm dia GI standard wire complete |
| 100 | Laying of 0.150 LT line on 8 mtr PCC poles with 120 mm sq at Udheywala , Canal approved under UT Capex Budget having scheme PDDSS2627100487 ( Providing/Supplying, Erection/Installation, Testing & commissioning comp Job) |
| 101 | PCC Poles 8 Mtr Long (WL: 200 Kg) |
| 102 | 120 mm sq AB Cable |
| 103 | Tension Clamp |
| 104 | Galvanized nuts & Bolts |
| 105 | Danger Plates |
| 106 | Anti Climbing Devices with Clamps |
| 107 | Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm 2.5 mtr long through GI Strip |
| 108 | Stone Pad |
| 109 | Insulating Piercing Connectors |
| 110 | PG Clamps |
| 111 | Galvanized Stay Set with 50X8mm Stay clamp, Guy insulator (2 Nos), anchor plate (200X200X6mm) Nuts & Bolts, 2 nos turn buckles,1.8mm long, 16mm diameter solid GS stay rod and 7/3.15mm dia GI standard wire complete |
| 112 | Laying of 0.25 km LT line extension at Nather Kothian Nr. army school Barani C/O Sh Rattan Lal sangral 7051079329 of 50 mm sq LT line ABC on 8 mtrs PCC poles , Canal approved under UT Capex Budget having scheme PDDSS2627100487 ( Providing/Supplying, Erection/Installation, Testing & commissioning comp Job) |
| 113 | PCC Poles 8 Mtr Long (WL: 200 Kg) |
| 114 | 50 mm sq AB Cable |
| 115 | Tension Clamp |
| 116 | Stright Through Cable Joinkit |
| 117 | Galvanized nuts & Bolts |
| 118 | Danger Plates |
| 119 | Anti Climbing Devices with Clamps |
| 120 | Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm 2.5 mtr long through GI Strip |
| 121 | Stone Pad |
| 122 | Insulating Piercing Connectors |
| 123 | PG Clamps |
| 124 | Galvanized Stay Set with 50X8mm Stay clamp, Guy insulator (2 Nos), anchor plate (200X200X6mm) Nuts & Bolts, 2 nos turn buckles,1.8mm long, 16mm diameter solid GS stay rod and 7/3.15mm dia GI standard wire complete |
| 125 | Laying of 0.200 LT line at Tikri Khani for Sh. Ganesh Kumar S/o Parmanand 7780988946 with 50 mm sq LT line ABC on 8 mtrs PCC poles , canal approved under UT Capex Budget having scheme PDDSS2627100487 ( Providing/Supplying, Erection/Installation, Testing & commissioning comp Job) |
| 126 | PCC Poles 8 Mtr Long (WL: 200 Kg) |
| 127 | 50 mm sq AB Cable |
| 128 | Stright Through Cable Joinkit |
| 129 | Tension Clamp |
| 130 | Galvanized nuts & Bolts |
| 131 | Danger Plates |
| 132 | Anti Climbing Devices with Clamps |
| 133 | Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm 2.5 mtr long through GI Strip |
| 134 | Stone Pad |
| 135 | Insulating Piercing Connectors |
| 136 | PG Clamps |
| 137 | Galvanized Stay Set with 50X8mm Stay clamp, Guy insulator (2 Nos), anchor plate (200X200X6mm) Nuts & Bolts, 2 nos turn buckles,1.8mm long, 16mm diameter solid GS stay rod and 7/3.15mm dia GI standard wire complete |
| 138 | Laying of .200 LT line at Mohalla Yogiraj Swami Nand lal ji , Tikkiri ashram lower Pooni Chak w no 32 Jammu , Mob no 8825057053 with 50 mm sq LT line ABC on 8 mtrs PCC poles , Canal approved under UT Capex Budget having scheme PDDSS2627100487 ( Providing/Supplying, Erection/Installation, Testing & commissioning comp Job) |
| 139 | PCC Poles 8 Mtr Long (WL: 200 Kg) |
| 140 | 50 mm sq AB Cable |
| 141 | Stright Through Cable Joinkit |
| 142 | Tension Clamp |
| 143 | Galvanized nuts & Bolts |
| 144 | Danger Plates |
| 145 | Anti Climbing Devices with Clamps |
| 146 | Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm 2.5 mtr long through GI Strip |
| 147 | Stone Pad |
| 148 | Insulating Piercing Connectors |
| 149 | PG Clamps |
| 150 | Galvanized Stay Set with 50X8mm Stay clamp, Guy insulator (2 Nos), anchor plate (200X200X6mm) Nuts & Bolts, 2 nos turn buckles,1.8mm long, 16mm diameter solid GS stay rod and 7/3.15mm dia GI standard wire complete |
| 151 | Laying of 0.100 LT line at village Patyala chak Nagbani smt Kamlesh Kumari W.O Sh. Yograj sharma ( 7889648046) with 50 mm sq LT line ABC on 8 mtrs PCC poles , Janipur approved under UT Capex Budget having scheme PDDSS2627100487 ( Providing/Supplying, Erection/Installation, Testing & commissioning comp Job) |
| 152 | PCC Poles 8 Mtr Long (WL: 200 Kg) |
| 153 | 50 mm sq AB Cable |
| 154 | Tension Clamp |
| 155 | Stright Through Cable Joinkit |
| 156 | Galvanized nuts & Bolts |
| 157 | Danger Plates |
| 158 | Anti Climbing Devices with Clamps |
| 159 | Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm 2.5 mtr long through GI Strip |
| 160 | Stone Pad |
| 161 | Insulating Piercing Connectors |
| 162 | PG Clamps |
| 163 | Laying of 0.25 LT line at Bandral kalan 9 Jarnail singh 90706034341 with 50 mm sq LT line ABC on 8 mtrs PCC poles , Akhnoor approved under UT Capex Budget having scheme PDDSS2627100487 ( Providing/Supplying, Erection/Installation, Testing & commissioning comp Job) |
| 164 | PCC Poles 8 Mtr Long (WL: 200 Kg) |
| 165 | 50 mm sq AB Cable |
| 166 | Tension Clamp |
| 167 | Stright Through Cable Joinkit |
| 168 | Galvanized nuts & Bolts |
| 169 | Danger Plates |
| 170 | Anti Climbing Devices with Clamps |
| 171 | Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm 2.5 mtr long through GI Strip |
| 172 | Stone Pad |
| 173 | Insulating Piercing Connectors |
| 174 | PG Clamps |
| 175 | Galvanized Stay Set with 50X8mm Stay clamp, Guy insulator (2 Nos), anchor plate (200X200X6mm) Nuts & Bolts, 2 nos turn buckles,1.8mm long, 16mm diameter solid GS stay rod and 7/3.15mm dia GI standard wire complete |
| 176 | Laying of 0.150 LT line at Parkhoo Near Royal Farm Sh. Raspaul singh, 6005547004 with 50 mm sq LT line ABC on 8 mtrs PCC poles , Janipur approved under UT Capex Budget having scheme PDDSS2627100487 ( Providing/Supplying, Erection/Installation, Testing & commissioning comp Job) |
| 177 | PCC Poles 8 Mtr Long (WL: 200 Kg) |
| 178 | 50 mm sq AB Cable |
| 179 | Tension Clamp |
| 180 | Stright Through Cable Joinkit |
| 181 | Galvanized nuts & Bolts |
| 182 | Danger Plates |
| 183 | Anti Climbing Devices with Clamps |
| 184 | Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm 2.5 mtr long through GI Strip |
| 185 | Stone Pad |
| 186 | Insulating Piercing Connectors |
| 187 | PG Clamps |
| 188 | Galvanized Stay Set with 50X8mm Stay clamp, Guy insulator (2 Nos), anchor plate (200X200X6mm) Nuts & Bolts, 2 nos turn buckles,1.8mm long, 16mm diameter solid GS stay rod and 7/3.15mm dia GI standard wire complete |
| 189 | Laying .350 km LT line at old Mandir Babaji , Bus Stand Kalyar Mathwar 9906793355 (1 Phase 2 Wire) on 8 Mtr. PCC poles using weasel ACSR approved under UT Capex Budget having scheme PDDSS2627100487 ( Providing/Supplying, Erection/Installation, Testing & commissioning comp Job) |
| 190 | PCC Poles 8 Mtr Long (WL: 200 Kg) |
| 191 | GI U-Clamps for Shakle Insulators |
| 192 | ACSR Weasel conductor(30 mm²) |
| 193 | 16 KN polymer shackle insulators |
| 194 | Galvanized nuts & Bolts |
| 195 | Danger Plates |
| 196 | Anti Climbing Devices with Clamps |
| 197 | Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm 2.5 mtr long through GI Strip |
| 198 | Stone Pad |
| 199 | Aluminium jointing sleeves |
| 200 | LT line spacers |
| 201 | Galvanized Stay Set with 50X8mm Stay clamp, Guy insulator (2 Nos), anchor plate (200X200X6mm) Nuts & Bolts, 2 nos turn buckles,1.8mm long, 16mm diameter solid GS stay rod and 7/3.15mm dia GI standard wire complete |
| 202 | laying of 1.30 km LT line at Mohalla sarmala , Mohalla Patayari , Mohalla Naryani,Pyt. Upper Narayana pahariwala on 8 mtr alongwith weasel conductor (1 Phase 2 Wire) approved under UT Capex Budget having scheme PDDSS2627100487 ( Providing/Supplying, Erection/Installation, Testing & commissioning comp Job) |
| 203 | PCC Poles 8 Mtr Long (WL: 200 Kg) |
| 204 | GI U-Clamps for Shakle Insulators |
| 205 | ACSR Weasel conductor(30 mm²) |
| 206 | 16 KN polymer shackle insulators |
| 207 | Galvanized nuts & Bolts |
| 208 | Danger Plates |
| 209 | Anti Climbing Devices with Clamps |
| 210 | Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm 2.5 mtr long through GI Strip |
| 211 | Stone Pad |
| 212 | Aluminium jointing sleeves |
| 213 | LT line spacers |
| 214 | Galvanized Stay Set with 50X8mm Stay clamp, Guy insulator (2 Nos), anchor plate (200X200X6mm) Nuts & Bolts, 2 nos turn buckles,1.8mm long, 16mm diameter solid GS stay rod and 7/3.15mm dia GI standard wire complete |
| 215 | Laying of .500 km LT line at pyt chowki Choura (1 Phase 2 Wire) on 8 Mtr. PCC poles using weasel ACSR approved under UT Capex Budget having scheme PDDSS2627100487 , Jourian ( Providing/Supplying, Erection/Installation, Testing & commissioning comp Job) |
| 216 | PCC Poles 8 Mtr Long (WL: 200 Kg) |
| 217 | GI U-Clamps for Shakle Insulators |
| 218 | ACSR Weasel conductor(30 mm²) |
| 219 | 16 KN polymer shackle insulators |
| 220 | Galvanized nuts & Bolts |
| 221 | Danger Plates |
| 222 | Anti Climbing Devices with Clamps |
| 223 | Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm 2.5 mtr long through GI Strip |
| 224 | Stone Pad |
| 225 | Aluminium jointing sleeves |
| 226 | LT line spacers |
| 227 | Galvanized Stay Set with 50X8mm Stay clamp, Guy insulator (2 Nos), anchor plate (200X200X6mm) Nuts & Bolts, 2 nos turn buckles,1.8mm long, 16mm diameter solid GS stay rod and 7/3.15mm dia GI standard wire complete |
| 228 | Laying of 0.100 km LT line at Village Kapai De Ban Akhnoor in Favour Ram lal (1 Phase 2 Wire) on 8 Mtr. PCC poles using weasel ACSR approved under UT Capex Budget having scheme PDDSS2627100487 ( Providing/Supplying, Erection/Installation, Testing & commissioning comp Job) |
| 229 | PCC Poles 8 Mtr Long (WL: 200 Kg) |
| 230 | GI U-Clamps for Shakle Insulators |
| 231 | ACSR Weasel conductor(30 mm²) |
| 232 | 16 KN polymer shackle insulators |
| 233 | Galvanized nuts & Bolts |
| 234 | Danger Plates |
| 235 | Anti Climbing Devices with Clamps |
| 236 | Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm 2.5 mtr long through GI Strip |
| 237 | Stone Pad |
| 238 | Aluminium jointing sleeves |
| 239 | LT line spacers |
| 240 | Laying of 0.100 km LT line at village Jadh in favour of Doulat Ram (1 Phase 2 Wire) on 8 Mtr. PCC poles using weasel ACSR approved under UT Capex Budget having scheme PDDSS2627100487 , Akhnoor ( Providing/Supplying, Erection/Installation, Testing & commissioning comp Job) |
| 241 | PCC Poles 8 Mtr Long (WL: 200 Kg) |
| 242 | GI U-Clamps for Shakle Insulators |
| 243 | ACSR Weasel conductor(30 mm²) |
| 244 | 16 KN polymer shackle insulators |
| 245 | Galvanized nuts & Bolts |
| 246 | Danger Plates |
| 247 | Anti Climbing Devices with Clamps |
| 248 | Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm 2.5 mtr long through GI Strip |
| 249 | Stone Pad |
| 250 | Aluminium jointing sleeves |
| 251 | LT line spacers |
| 252 | Laying of 0.350 LT line at Village w no 1 Bhadore , Sh Harbans lal ,9682590437 (3 Phase 4 Wire) on 8 Mtr. PCC poles using weasel ACSR , canal approved under UT Capex Budget having scheme PDDSS2627100487 ( Providing/Supplying, Erection/Installation, Testing & commissioning comp Job) |
| 253 | PCC Poles 8 Mtr Long (WL: 200 Kg) |
| 254 | GI U-Clamps for Shakle Insulators |
| 255 | ACSR Weasel conductor(30 mm²) |
| 256 | 16 KN polymer shackle insulators |
| 257 | Galvanized nuts & Bolts |
| 258 | Danger Plates |
| 259 | Anti Climbing Devices with Clamps |
| 260 | Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm 2.5 mtr long through GI Strip |
| 261 | Stone Pad |
| 262 | Aluminium jointing sleeves |
| 263 | LT line spacers |
| 264 | Galvanized Stay Set with 50X8mm Stay clamp, Guy insulator (2 Nos), anchor plate (200X200X6mm) Nuts & Bolts, 2 nos turn buckles,1.8mm long, 16mm diameter solid GS stay rod and 7/3.15mm dia GI standard wire complete |
| 265 | Laying of 0.300 km LT line at Graveyard Nadwal wno 1 Bhalwal ( C/o sarpanch ) 6005181711 (3 Phase 4 Wire) on 8 Mtr. PCC poles using weasel ACSR approved under UT Capex Budget having scheme PDDSS2627100487 , Janipur( Providing/Supplying, Erection/Installation, Testing & commissioning comp Job) |
| 266 | PCC Poles 8 Mtr Long (WL: 200 Kg) |
| 267 | GI U-Clamps for Shakle Insulators |
| 268 | ACSR Weasel conductor(30 mm²) |
| 269 | 16 KN polymer shackle insulators |
| 270 | Galvanized nuts & Bolts |
| 271 | Danger Plates |
| 272 | Anti Climbing Devices with Clamps |
| 273 | Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm 2.5 mtr long through GI Strip |
| 274 | Stone Pad |
| 275 | Aluminium jointing sleeves |
| 276 | LT line spacers |
| 277 | Galvanized Stay Set with 50X8mm Stay clamp, Guy insulator (2 Nos), anchor plate (200X200X6mm) Nuts & Bolts, 2 nos turn buckles,1.8mm long, 16mm diameter solid GS stay rod and 7/3.15mm dia GI standard wire complete |
| 278 | Laying of .500 km LT line at house of Ab. Rashid S/O Farman Ali R/O Ranjan Thathi (3 Phase 4 Wire) on 8 Mtr. PCC poles using weasel ACSR approved under UT Capex Budget having scheme PDDSS2627100487 , Janipur( Providing/Supplying, Erection/Installation, Testing & commissioning comp Job) |
| 279 | PCC Poles 8 Mtr Long (WL: 200 Kg) |
| 280 | GI U-Clamps for Shakle Insulators |
| 281 | ACSR Weasel conductor(30 mm²) |
| 282 | 16 KN polymer shackle insulators |
| 283 | Galvanized nuts & Bolts |
| 284 | Danger Plates |
| 285 | Anti Climbing Devices with Clamps |
| 286 | Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm 2.5 mtr long through GI Strip |
| 287 | Stone Pad |
| 288 | Aluminium jointing sleeves |
| 289 | LT line spacers |
| 290 | Galvanized Stay Set with 50X8mm Stay clamp, Guy insulator (2 Nos), anchor plate (200X200X6mm) Nuts & Bolts, 2 nos turn buckles,1.8mm long, 16mm diameter solid GS stay rod and 7/3.15mm dia GI standard wire complete |
| 291 | Laying of 0.250 km LT line on 8 mtr PCC poles with weasel conductor at Village Garkhal Jajyal Jammu Sh. Jankar singh 9541839174 (3 Phase 4 Wire) on 8 Mtr. PCC poles using weasel ACSR approved under UT Capex Budget having scheme PDDSS2627100487 , Janipur( Providing/Supplying, Erection/Installation, Testing & commissioning comp Job) |
| 292 | PCC Poles 8 Mtr Long (WL: 200 Kg) |
| 293 | GI U-Clamps for Shakle Insulators |
| 294 | ACSR Weasel conductor(30 mm²) |
| 295 | 16 KN polymer shackle insulators |
| 296 | Galvanized nuts & Bolts |
| 297 | Danger Plates |
| 298 | Anti Climbing Devices with Clamps |
| 299 | Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm 2.5 mtr long through GI Strip |
| 300 | Stone Pad |
| 301 | Aluminium jointing sleeves |
| 302 | LT line spacers |
| 303 | Erection of 0.4 Km 11KV Line on 9 meter PCC Poles, 30mm2 ACSR Conductor at Rama Colony Tehsil Akhnoor from Sh Girdhari Lal Sharma ( Sub Major) 9906292762( Providing/Supplying, Erection/Installation, Testing & commissioning comp Job) |
| 304 | PCC Poles 9.0 Mtr long (WL:300Kg ) |
| 305 | GI V Cross arm with top bracket including clamp |
| 306 | GI Channel X-arm including clamp and braces |
| 307 | ACSR weasel Conductor(30 mm²) |
| 308 | PG Clamps for ACSR Weasel Conductor |
| 309 | 11 KV Polymer composite Pin Insulators 12KV,5KN, Lighting impulse 75KV positive and 80KV negative, creepage distance 320mm |
| 310 | 11 KV Polymer composite Disc nsulators 12KV, min falling load 45KN, Lighting impulse 75KV positive and 80KV negative, creepage distance 320mm |
| 311 | Galvanized nuts & Bolts |
| 312 | Danger Plates with Clamps |
| 313 | Anti Climbing Device with Clamps |
| 314 | Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm 2.5 mtr long through GI Strip |
| 315 | Stone Pad |
| 316 | Aluminium Jointing sleeves |
| 317 | Galvanized Stay Set with 50X8mm Stay clamp, Guy insulator (2 Nos), anchor plate (200X200X6mm) Nuts & Bolts, 2 nos turn buckles,1.8mm long, 16mm diameter solid GS stay rod and 7/3.15mm dia GI standard wire complete Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information Compatibility Report for BOQe-NIT68.xls Run on 05-03-2024 17:31 If the workbook is saved in an earlier file format or opened in an earlier version of Microsoft Excel, the listed features will not be available. Significant loss of functionality # of occurrences Version Any effects on this object will be removed. Any text that overflows the boundaries of this graphic will appear truncated. 3.0 Excel 97-2003 Some cells in this workbook contain data validation rules, which refer to values on other worksheets. These rules won't be saved. 4.0 Excel 97-2003 Minor loss of fidelity Some cells or styles in this workbook contain formatting that is not supported by the selected file format. These formats will be converted to the closest format available. 4.0 Excel 97-2003 |
AI Tender Summary
Tender Timeline
Aug 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 11, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysSep 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender