Defence Statutory Bodies & Commissions/Committees Closing in 5 days TDR #57092418

Bids Are invited for Spl Repair Replacement Of Exhaust Fans And Geysers Against Ber

Issued by Statutory Bodies & Commissions/Committees · North 24 Parganas, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
29 Aug 2026
5 days left
EMD
22000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
North 24 Parganas → West Bengal
EMD Exemption
Available
Quantity
438

Project Description

Bids Are invited for Spl Repair Replacement Of Exhaust Fans And Geysers Against Ber Taking Down Carefully Copper-Aluminium Point Wiring Exhaust Fan Point, Power Point Complete, Including Fixtures And Fittings Such As Switches, Ceiling Roses, Sockets. - Taking Down Carefully Copper-Aluminium Point Wiring Exhaust Fan Point, Power Point Complete, Including Fixtures And Fittings Such As Switches, Ceiling Roses, Sockets, And Including Making Good The Disturbed Surfaces To Match With Existing Surface And Colour Shade With Putty At Necessary Holes For Smooth Finishing Complete All As Specified And Directed Complete All As Specified And Directed. , Material And Labour For Point Wiring Complete With 1.5 Sqmm Pvc Insulate, Isi Marked Is-694-1990, 1 Core, Copper Conductor Cable 1100 V Gd For 1 Exhaust Fan Point Controlled By 1 Switch - Colour Code Cables And Including Cutting Work At Any Height And All Accessories Casing Caping In Walls-Roofs -Floors Ceiling Etc. Flush Mounting Ms Box With Top, Bottom, Side-Back Wall Knockout For Casing Caping Entry From Any Direction Made Out Of 1.60Mm Thick Suitable For Fixing Of And Including White-Silver-Dark Bronze Colour Modular Blanking Plate As Per Number Of Switch Modules Flush Mounted For Fixing Of Modular Switches, Sockets, Fan Regulators, Blank Plate Etc And Including Above Mentioned Colour Modular Plate Cover Of Required Modules And Including 1.5 Sqmm Complete All As Specified And Directed , Supply And Fixing Modular Type Switch 6 S, Single Pole, 1Way, 1 Module.240V, Ac Isi Marked Complete All As Specified And Directed. , Supply And Fix Ceiling Rose, 3 Terminal, Pvc-Polycarbonate Body Isi Marked Complete All As Specified And Directed , Cleaning And Modification Of Wall Cutting As Per Size Of The New Exhaust Fan Deplastring The Nearest Area Approx Area 0.6M X 0.6 M And Plastering Again 1 Ratio 6. - Cleaning And Modification Of Wall Cutting As Per Size Of The New Exhaust Fan Deplastring The Nearest Area Approx Area 0.6M X 0.6 M And Plastering Again 1 Ratio 6. Fixing 4 Nos Nut And Bolt For Hanging The Exhaust Fan Including T And P And Scaffholding As Required Max Upto 10M Height Making Good The Disturbed Surface Area With Cement And Putty Match With Existing Colour Shade Complete All As Specified And Directed. , Taking Down Existing Old Exhaust Fan And Lauers Of Any Type-Size From Any Height Max Upto Two Storage Bldg And Deposited To Mes Store Yard For Further Na Pl. , Supply And Fixing Exhaust Fan Steel Body Ac Single Phase, 230V Of Size 230Mm Sweep With Blade, Frame, Louvers Etc. Complete All As Specified And Directed. , Taking Down Old Electric Water Heater Of Any Type And Capacity, Storage Type Steel Body And Deposit To Mes Store For Further Na Pl Incl Taking Out Old - Taking Down Old Electric Water Heater Of Any Type And Capacity, Storage Type Steel Body And Deposit To Mes Store For Further Na Pl. Incl Taking Out Old Rusted Bolts, Cleaning And Plastering In Broken Portion As Existing And Fixing New Fastner All As Specified And Directed Rate Quoted In Inclusive Material, Labour And Tpn Reqd For The Same Work.

BOQ

Sl. No. Item TitleItem Description
1Taking down carefully copper-aluminium point wiring exhaust fan point, power point complete, including fixtures and fittings such as switches, ceiling roses, sockets.Taking down carefully copper-aluminium point wiring exhaust fan point, power point complete, including fixtures and fittings such as switches, ceiling roses, sockets, and including making good the disturbed surfaces to match with existing surface and colour shade with putty at necessary holes for smooth finishing complete all as specified and directed complete all as specified and directed.
2Material and labour for point wiring complete with 1.5 sqmm PVC insulate, ISI marked IS-694-1990, 1 core, copper conductor cable 1100 V Gd for 1 exhaust fan point controlled by 1 switchcolour code cables and including cutting work at any height and all accessories casing caping in walls-roofs -floors ceiling etc. flush mounting MS box with top, bottom, side-back wall knockout for casing caping entry from any direction made out of 1.60mm thick suitable for fixing of and including white-Silver-Dark bronze colour modular blanking plate as per number of switch modules flush mounted for fixing of modular switches, sockets, fan regulators, blank plate etc and including above mentioned colour modular plate cover of required modules and including 1.5 Sqmm complete all as specified and directed
3Supply and fixing modular type switch 6 Amps, single pole, 1way, 1 module.240V, AC ISI Marked complete all as specified and directed.Supply and fixing modular type switch 6 Amps, single pole, 1way, 1 module.240V, AC ISI Marked complete all as specified and directed.
4Supply and fix ceiling rose, 3 terminal, PVC-polycarbonate body ISI marked complete all as specified and directedSupply and fix ceiling rose, 3 terminal, PVC-polycarbonate body ISI marked complete all as specified and directed
5Cleaning and modification of wall cutting as per size of the new exhaust fan Deplastring the nearest area approx area 0.6m x 0.6 m and plastering again 1 ratio 6.Cleaning and modification of wall cutting as per size of the new exhaust fan Deplastring the nearest area approx area 0.6m x 0.6 m and plastering again 1 ratio 6. Fixing 4 nos nut and bolt for hanging the exhaust fan including T and P and scaffholding as required max upto 10m height making good the disturbed surface area with cement and putty match with existing colour shade complete all as specified and directed.
6Taking down existing old exhaust fan and lauers of any type-size from any height max upto two storage bldg and deposited to MES Store yard for further na pl.Taking down existing old exhaust fan and lauers of any type-size from any height max upto two storage bldg and deposited to MES Store yard for further na pl.
7Supply and fixing Exhaust fan steel body AC single phase, 230V of size 230mm sweep with blade, frame, louvers etc. complete all as specified and directed.Supply and fixing Exhaust fan steel body AC single phase, 230V of size 230mm sweep with blade, frame, louvers etc. complete all as specified and directed.
8Taking down old electric water heater of any type and capacity, storage type steel body and deposit to MES store for further na pl Incl taking out oldTaking down old electric water heater of any type and capacity, storage type steel body and deposit to MES store for further na pl. Incl taking out old rusted bolts, cleaning and plastering in broken portion as existing and fixing new fastner all as specified and directed rate quoted in inclusive material, labour and TPN reqd for the same work.

AI Tender Summary

OUR REF NO 57092418
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 29-08-2026
Authority
Authority Name Indian Army
Work Description Bids Are invited for Spl Repair Replacement Of Exhaust Fans And Geysers Against Ber Taking Down Carefully Copper-Aluminium Point Wiring Exhaust Fan Point, Power Point Complete, Including Fixtures And Fittings Such As Switches, Ceiling Roses, Sockets. - Taking Down Carefully Copper-Aluminium Point Wiring Exhaust Fan Point, Power Point Complete, Including Fixtures And Fittings Such As Switches, Ceiling Roses, Sockets, And Including Making Good The Disturbed Surfaces To Match With Existing Surface And Colour Shade With Putty At Necessary Holes For Smooth Finishing Complete All As Specified And Directed Complete All As Specified And Directed. , Material And Labour For Point Wiring Complete With 1.5 Sqmm Pvc Insulate, Isi Marked Is-694-1990, 1 Core, Copper Conductor Cable 1100 V Gd For 1 Exhaust Fan Point Controlled By 1 Switch - Colour Code Cables And Including Cutting Work At Any Height And All Accessories Casing Caping In Walls-Roofs -Floors Ceiling Etc. Flush Mounting Ms Box With Top, Bottom, Side-Back Wall Knockout For Casing Caping Entry From Any Direction Made Out Of 1.60Mm Thick Suitable For Fixing Of And Including White-Silver-Dark Bronze Colour Modular Blanking Plate As Per Number Of Switch Modules Flush Mounted For Fixing Of Modular Switches, Sockets, Fan Regulators, Blank Plate Etc And Including Above Mentioned Colour Modular Plate Cover Of Required Modules And Including 1.5 Sqmm Complete All As Specified And Directed , Supply And Fixing Modular Type Switch 6 S, Single Pole, 1Way, 1 Module.240V, Ac Isi Marked Complete All As Specified And Directed. , Supply And Fix Ceiling Rose, 3 Terminal, Pvc-Polycarbonate Body Isi Marked Complete All As Specified And Directed , Cleaning And Modification Of Wall Cutting As Per Size Of The New Exhaust Fan Deplastring The Nearest Area Approx Area 0.6M X 0.6 M And Plastering Again 1 Ratio 6. - Cleaning And Modification Of Wall Cutting As Per Size Of The New Exhaust Fan Deplastring The Nearest Area Approx Area 0.6M X 0.6 M And Plastering Again 1 Ratio 6. Fixing 4 Nos Nut And Bolt For Hanging The Exhaust Fan Including T And P And Scaffholding As Required Max Upto 10M Height Making Good The Disturbed Surface Area With Cement And Putty Match With Existing Colour Shade Complete All As Specified And Directed. , Taking Down Existing Old Exhaust Fan And Lauers Of Any Type-Size From Any Height Max Upto Two Storage Bldg And Deposited To Mes Store Yard For Further Na Pl. , Supply And Fixing Exhaust Fan Steel Body Ac Single Phase, 230V Of Size 230Mm Sweep With Blade, Frame, Louvers Etc. Complete All As Specified And Directed. , Taking Down Old Electric Water Heater Of Any Type And Capacity, Storage Type Steel Body And Deposit To Mes Store For Further Na Pl Incl Taking Out Old - Taking Down Old Electric Water Heater Of Any Type And Capacity, Storage Type Steel Body And Deposit To Mes Store For Further Na Pl. Incl Taking Out Old Rusted Bolts, Cleaning And Plastering In Broken Portion As Existing And Fixing New Fastner All As Specified And Directed Rate Quoted In Inclusive Material, Labour And Tpn Reqd For The Same Work.
Basic Detail
Tender No GEM/2026/B/7916150
Bidding Type Tender
Location
City North 24 Parganas
State West Bengal
Key Dates
Publish Date 19 Aug 2026
Submission Date 29 Aug 2026
Open Date 29 Aug 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 22000
Exemption Available
Document List
04c5eb32-4f78-4678-8431-9abe1d97587c.pdf
9754341_Boq_1.xlsx
specification_files_eg_0001_2026-08-13-18-47-12_2af38e8e65e492d872e4b7f6151e1bd7.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Aug 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
pdf

04c5eb32-4f78-4678-8431-9abe1d97587c.pdf

xlsx

9754341_Boq_1.xlsx

pdf

specification_files_eg_0001_2026-08-13-18-47-12_2af38e8e65e492d872e4b7f6151e1bd7.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender