Bids Are invited for Spl Repair Replacement Of Exhaust Fans And Geysers Against Ber
Tender Overview
Project Description
Bids Are invited for Spl Repair Replacement Of Exhaust Fans And Geysers Against Ber Taking Down Carefully Copper-Aluminium Point Wiring Exhaust Fan Point, Power Point Complete, Including Fixtures And Fittings Such As Switches, Ceiling Roses, Sockets. - Taking Down Carefully Copper-Aluminium Point Wiring Exhaust Fan Point, Power Point Complete, Including Fixtures And Fittings Such As Switches, Ceiling Roses, Sockets, And Including Making Good The Disturbed Surfaces To Match With Existing Surface And Colour Shade With Putty At Necessary Holes For Smooth Finishing Complete All As Specified And Directed Complete All As Specified And Directed. , Material And Labour For Point Wiring Complete With 1.5 Sqmm Pvc Insulate, Isi Marked Is-694-1990, 1 Core, Copper Conductor Cable 1100 V Gd For 1 Exhaust Fan Point Controlled By 1 Switch - Colour Code Cables And Including Cutting Work At Any Height And All Accessories Casing Caping In Walls-Roofs -Floors Ceiling Etc. Flush Mounting Ms Box With Top, Bottom, Side-Back Wall Knockout For Casing Caping Entry From Any Direction Made Out Of 1.60Mm Thick Suitable For Fixing Of And Including White-Silver-Dark Bronze Colour Modular Blanking Plate As Per Number Of Switch Modules Flush Mounted For Fixing Of Modular Switches, Sockets, Fan Regulators, Blank Plate Etc And Including Above Mentioned Colour Modular Plate Cover Of Required Modules And Including 1.5 Sqmm Complete All As Specified And Directed , Supply And Fixing Modular Type Switch 6 S, Single Pole, 1Way, 1 Module.240V, Ac Isi Marked Complete All As Specified And Directed. , Supply And Fix Ceiling Rose, 3 Terminal, Pvc-Polycarbonate Body Isi Marked Complete All As Specified And Directed , Cleaning And Modification Of Wall Cutting As Per Size Of The New Exhaust Fan Deplastring The Nearest Area Approx Area 0.6M X 0.6 M And Plastering Again 1 Ratio 6. - Cleaning And Modification Of Wall Cutting As Per Size Of The New Exhaust Fan Deplastring The Nearest Area Approx Area 0.6M X 0.6 M And Plastering Again 1 Ratio 6. Fixing 4 Nos Nut And Bolt For Hanging The Exhaust Fan Including T And P And Scaffholding As Required Max Upto 10M Height Making Good The Disturbed Surface Area With Cement And Putty Match With Existing Colour Shade Complete All As Specified And Directed. , Taking Down Existing Old Exhaust Fan And Lauers Of Any Type-Size From Any Height Max Upto Two Storage Bldg And Deposited To Mes Store Yard For Further Na Pl. , Supply And Fixing Exhaust Fan Steel Body Ac Single Phase, 230V Of Size 230Mm Sweep With Blade, Frame, Louvers Etc. Complete All As Specified And Directed. , Taking Down Old Electric Water Heater Of Any Type And Capacity, Storage Type Steel Body And Deposit To Mes Store For Further Na Pl Incl Taking Out Old - Taking Down Old Electric Water Heater Of Any Type And Capacity, Storage Type Steel Body And Deposit To Mes Store For Further Na Pl. Incl Taking Out Old Rusted Bolts, Cleaning And Plastering In Broken Portion As Existing And Fixing New Fastner All As Specified And Directed Rate Quoted In Inclusive Material, Labour And Tpn Reqd For The Same Work.
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Taking down carefully copper-aluminium point wiring exhaust fan point, power point complete, including fixtures and fittings such as switches, ceiling roses, sockets. | Taking down carefully copper-aluminium point wiring exhaust fan point, power point complete, including fixtures and fittings such as switches, ceiling roses, sockets, and including making good the disturbed surfaces to match with existing surface and colour shade with putty at necessary holes for smooth finishing complete all as specified and directed complete all as specified and directed. |
| 2 | Material and labour for point wiring complete with 1.5 sqmm PVC insulate, ISI marked IS-694-1990, 1 core, copper conductor cable 1100 V Gd for 1 exhaust fan point controlled by 1 switch | colour code cables and including cutting work at any height and all accessories casing caping in walls-roofs -floors ceiling etc. flush mounting MS box with top, bottom, side-back wall knockout for casing caping entry from any direction made out of 1.60mm thick suitable for fixing of and including white-Silver-Dark bronze colour modular blanking plate as per number of switch modules flush mounted for fixing of modular switches, sockets, fan regulators, blank plate etc and including above mentioned colour modular plate cover of required modules and including 1.5 Sqmm complete all as specified and directed |
| 3 | Supply and fixing modular type switch 6 Amps, single pole, 1way, 1 module.240V, AC ISI Marked complete all as specified and directed. | Supply and fixing modular type switch 6 Amps, single pole, 1way, 1 module.240V, AC ISI Marked complete all as specified and directed. |
| 4 | Supply and fix ceiling rose, 3 terminal, PVC-polycarbonate body ISI marked complete all as specified and directed | Supply and fix ceiling rose, 3 terminal, PVC-polycarbonate body ISI marked complete all as specified and directed |
| 5 | Cleaning and modification of wall cutting as per size of the new exhaust fan Deplastring the nearest area approx area 0.6m x 0.6 m and plastering again 1 ratio 6. | Cleaning and modification of wall cutting as per size of the new exhaust fan Deplastring the nearest area approx area 0.6m x 0.6 m and plastering again 1 ratio 6. Fixing 4 nos nut and bolt for hanging the exhaust fan including T and P and scaffholding as required max upto 10m height making good the disturbed surface area with cement and putty match with existing colour shade complete all as specified and directed. |
| 6 | Taking down existing old exhaust fan and lauers of any type-size from any height max upto two storage bldg and deposited to MES Store yard for further na pl. | Taking down existing old exhaust fan and lauers of any type-size from any height max upto two storage bldg and deposited to MES Store yard for further na pl. |
| 7 | Supply and fixing Exhaust fan steel body AC single phase, 230V of size 230mm sweep with blade, frame, louvers etc. complete all as specified and directed. | Supply and fixing Exhaust fan steel body AC single phase, 230V of size 230mm sweep with blade, frame, louvers etc. complete all as specified and directed. |
| 8 | Taking down old electric water heater of any type and capacity, storage type steel body and deposit to MES store for further na pl Incl taking out old | Taking down old electric water heater of any type and capacity, storage type steel body and deposit to MES store for further na pl. Incl taking out old rusted bolts, cleaning and plastering in broken portion as existing and fixing new fastner all as specified and directed rate quoted in inclusive material, labour and TPN reqd for the same work. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender