Tender For Provision Of Air Conditioning At Certain Location At Af Stn Bkt
Tender Value
4.93 Lakhs
Estimated cost
Bid Submission
08 Sep 2026
16 days left
EMD
10000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Lucknow → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provision Of Air Conditioning At Certain Location At Af Stn Bkt
BOQ
| Sl. No. | Item Description |
| 1 | Supply, installation,commissioning and testing of hi wall split type air conditioner inverter type of capacity 1.5 TR (4500 k Cal/hr) single phase suitable for 230 V + 10 %, 50Hz AC supply complete with cordless remote control unit using Non CFC refrigerant Gas, 5 star rating and energy efficient complete as comprising of following :-(a) indoor unit with three speed blower fan with motor of appropriate capacity including PCB,thermostatic control,air filter and drain for condensing water(b) Outdoor unit comprising compressor ,air cooled copper condensor with fan and motor unit shall be installed outside the building / on roof(c) Refrigerant copper pipe for suction and discharge line with insulation (up to 3.0 Mtrs) ,condensing water drain pipe & protected by suitable size of flexible PVC conduit with control valves & safty accessories including control wiring for evaporator & condensing Unit with suitable size of copper cable.Make- Daikin/ O General/ Mitsubishi/ HitachiNote :- (i). Cutting holes in walls/window of any thickness with cutting machine for installation of AC etc, connection and making good the disturbed surface to match with the existing surface after work shall be done and rate is included in above rate .(ii) Electrical cable required to connect outdoor unit wih indore unit and indore unit to voltage stabilizer inclusive in above rate. (iii) Refrigerant copper pipe for suction and discharge line with insulation beyond 3.0 Mtrs will measured and paid seperately. |
| 2 | S & F Powder coated MS bracket/wall stand for fixing out door unit in wall or rooftop with necessary grouting MS hold fast, bolts etc complete all as specified and directed. |
| 3 | Supply only of Copper Pipe of size 1/4\\"( with sleeves) |
| 4 | Supply only of Copper Pipe of size 1/2\\"( with sleeves) |
| 5 | S&F electronic wall mounted digital display(Input & output) voltage stabilizer for automatic voltage correction single phase, naturally air cooled, indoor type, mettalic body designed for input voltage between 140 Volt to 270 Volts and out put voltage 230Volt and High / low voltage cut off capacity 5 KVA complete all as specified and directed.Make : V-Guard/ Volina/ Microtek/ Blue Bird/ Everest |
| 6 | S& F Sheet metal enclosure, powder coated single pole and neutral with two pin and earth plug and socket (Mettalic) complete with one single pole MCB for 240 volts 20 Amps rating rupturning capacity 10 KA complete all as specified and directed. |
| 7 | S&F Sheet metal enclosure SPN 4 way double door distribution board ,415 volt complete all as specified and directed |
| 8 | S&F MCB SPN 63 Amps 240 volt,50 hz,10 KA breaking capacity \\"C\\" curved type complete all as specified and directed. |
| 9 | S&F MCB single pole, 6 to 32 Amps, 240 Volts 50 HZ, 10 KA breaking capacity complete all as specified and directed. |
| 10 | S&F Submain wiring with two single core PVC insulated FRLSH multistrand copper conductor cable of size 4 Sq mm drawn into and including non metallic heavy duty rigid concealed PVC conduit not less than 25 mm size ISI marked with all fittings / accessories and 04 Sq mm FRLSH multistrand copper conductor cable as continuous earth wire complete all as specified & directed. Note :- (i). Cutting holes in walls/window of any thickness with cutting machine for installation of AC etc, connection and making good the disturbed surface to match with the existing surface after work shall be done and rate is included in above rate .(ii) Electrical cable required to connect outdoor unit wih indore unit and indore unit to voltage stabilizer inclusive in above rate. (iii) Refrigerant copper pipe for suction and discharge line with insulation beyond 3.0 Mtrs will measured and paid seperately. |
| 11 | S&F Submain wiring with two single core PVC insulated FRLSH multistrand copper conductor cable of size 6 Sq mm drawn into and including non metallic heavy duty rigid concealed PVC conduit not less than 25 mm size ISI marked with all fittings / accessories and 04 Sq mm FRLSH multistrand copper conductor cable as continuous earth wire complete all as specified & directed. Note :- (i). Cutting holes in walls/window of any thickness with cutting machine for installation of AC etc, connection and making good the disturbed surface to match with the existing surface after work shall be done and rate is included in above rate .(ii) Electrical cable required to connect outdoor unit wih indore unit and indore unit to voltage stabilizer inclusive in above rate. (iii) Refrigerant copper pipe for suction and discharge line with insulation beyond 3.0 Mtrs will measured and paid seperately. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 08, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysSep 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender