Petroleum and Natural Gas Boards / Undertakings / PSU Closing in 9 days TDR #57092128

Tender For Replacement Of Existing Underground Power & Controls Cables With Above Ground Cables, Including The Supply & Installation Of The Cable Trays, And Associated Civil & Mechanical Works At Wrpl, Mundra Station.

Issued by Boards / Undertakings / PSU · Kachchh, Gujarat
Tender Value
3.67 Crore
Estimated cost
Bid Submission
02 Sep 2026
9 days left
EMD
92000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kachchh → Gujarat
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Replacement Of Existing Underground Power & Controls Cables With Above Ground Cables, Including The Supply & Installation Of The Cable Trays, And Associated Civil & Mechanical Works At Wrpl, Mundra Station.

BOQ

Name of Work:- Replacement of existing underground Power & Controls Cables with above ground Cables, including the Supply & installation of the Cable trays, and associated Civil & Mechanical works at WRPL, Mundra Station.
Sl. No. Item Description
1GST % for the tenderPlease select the rate of GST in cell AY13. Rate selected shall be applicable for all the items under BoQ.
2SITC of A/G Cable tray with cable laying
3LT CABLE END TERMINATION FOR ARMOURED / PVC INSULATED ALUMINIUM CABLE WITH DOUBLE COMPRESSION FLAME PROOF TYPE BRASS GLANDING (INCL UDING COST OF GLANDS & LUGS): Providing end termination of power/control cable including cutting, stripping, providing & fixing lugs , cable insulation, providing & glanding double compression heavy duty FLAME PROOF TYPE brass cable gland conforming to IS-12943 (Do well's or approved equivalent), wherever specified, providing aluminium lugs, crimping/soldering, as necessary, restoration of insul ation/clamping of cable, tagging with aluminium tag,earthing of armour, connection to the equipment terminals etc. all complete with labour and materials as per standard and direction of the Engineer-in- charge : 3 x 10 sqmm
4LT CABLE END TERMINATION FOR ARMOURED / PVC INSULATED ALUMINIUM CABLE WITH DOUBLE COMPRESSION FLAME PROOF TYPE BRASS GLANDING (INCL UDING COST OF GLANDS & LUGS): Providing end termination of power/control cable including cutting, stripping, providing & fixing lugs , cable insulation, providing & glanding double compression heavy duty FLAME PROOF TYPE brass cable gland conforming to IS-12943 (Do well's or approved equivalent), wherever specified, providing aluminium lugs, crimping/soldering, as necessary, restoration of insul ation/clamping of cable, tagging with aluminium tag,earthing of armour, connection to the equipment terminals etc. all complete with labour and materials as per standard and direction of the Engineer-in- charge : 3 x 95 sqmm
5LT CABLE END TERMINATION FOR ARMOURED / PVC INSULATED ALUMINIUM CABLE WITH DOUBLE COMPRESSION FLAME PROOF TYPE BRASS GLANDING (INCL UDING COST OF GLANDS & LUGS): Providing end termination of power/control cable including cutting, stripping, providing & fixing lugs , cable insulation, providing & glanding double compression heavy duty FLAME PROOF TYPE brass cable gland conforming to IS-12943 (Do well's or approved equivalent), wherever specified, providing aluminium lugs, crimping/soldering, as necessary, restoration of insul ation/clamping of cable, tagging with aluminium tag,earthing of armour, connection to the equipment terminals etc. all complete with labour and materials as per standard and direction of the Engineer-in- charge : 4 x 25 sqmm
6LT CABLE END TERMINATION FOR ARMOURED / PVC INSULATED ALUMINIUM CABLE WITH DOUBLE COMPRESSION FLAME PROOF TYPE BRASS GLANDING (INCL UDING COST OF GLANDS & LUGS): Providing end termination of power/control cable including cutting, stripping, providing & fixing lugs , cable insulation, providing & glanding double compression heavy duty FLAME PROOF TYPE brass cable gland conforming to IS-12943 (Do well's or approved equivalent), wherever specified, providing aluminium lugs, crimping/soldering, as necessary, restoration of insul ation/clamping of cable, tagging with aluminium tag,earthing of armour, connection to the equipment terminals etc. all complete with labour and materials as per standard and direction of the Engineer-in- charge : 3-1/2 x 25 sqmm
7LT CABLE END TERMINATION FOR ARMOURED / PVC INSULATED ALUMINIUM CABLE WITH DOUBLE COMPRESSION FLAME PROOF TYPE BRASS GLANDING (INCL UDING COST OF GLANDS & LUGS): Providing end termination of power/control cable including cutting, stripping, providing & fixing lugs , cable insulation, providing & glanding double compression heavy duty FLAME PROOF TYPE brass cable gland conforming to IS-12943 (Do well's or approved equivalent), wherever specified, providing aluminium lugs, crimping/soldering, as necessary, restoration of insul ation/clamping of cable, tagging with aluminium tag,earthing of armour, connection to the equipment terminals etc. all complete with labour and materials as per standard and direction of the Engineer-in- charge : 3-1/2 x 400 sqmm
8LT CABLE END TERMINATION FOR ARMOURED / PVC INSULATED ALUMINIUM CABLE WITH DOUBLE COMPRESSION FLAME PROOF TYPE BRASS GLANDING (INCL UDING COST OF GLANDS & LUGS): Providing end termination of power/control cable including cutting, stripping, providing & fixing lugs , cable insulation, providing & glanding double compression heavy duty FLAME PROOF TYPE brass cable gland conforming to IS-12943 (Do well's or approved equivalent), wherever specified, providing aluminium lugs, crimping/soldering, as necessary, restoration of insul ation/clamping of cable, tagging with aluminium tag,earthing of armour, connection to the equipment terminals etc. all complete with labour and materials as per standard and direction of the Engineer-in- charge : 2 x 6 sqmm
9LT CABLE END TERMINATION FOR ARMOURED / PVC INSULATED ALUMINIUM CABLE WITH DOUBLE COMPRESSION FLAME PROOF TYPE BRASS GLANDING (INCL UDING COST OF GLANDS & LUGS): Providing end termination of power/control cable including cutting, stripping, providing & fixing lugs , cable insulation, providing & glanding double compression heavy duty FLAME PROOF TYPE brass cable gland conforming to IS-12943 (Do well's or approved equivalent), wherever specified, providing aluminium lugs, crimping/soldering, as necessary, restoration of insul ation/clamping of cable, tagging with aluminium tag,earthing of armour, connection to the equipment terminals etc. all complete with labour and materials as per standard and direction of the Engineer-in- charge : 6 x 2.5 sqmm
10LT CABLE END TERMINATION FOR ARMOURED / PVC INSULATED ALUMINIUM CABLE WITH DOUBLE COMPRESSION FLAME PROOF TYPE BRASS GLANDING (INCL UDING COST OF GLANDS & LUGS): Providing end termination of power/control cable including cutting, stripping, providing & fixing lugs , cable insulation, providing & glanding double compression heavy duty FLAME PROOF TYPE brass cable gland conforming to IS-12943 (Do well's or approved equivalent), wherever specified, providing aluminium lugs, crimping/soldering, as necessary, restoration of insul ation/clamping of cable, tagging with aluminium tag,earthing of armour, connection to the equipment terminals etc. all complete with labour and materials as per standard and direction of the Engineer-in- charge : 4 x 4 Sqmm
11LT CABLE END TERMINATION FOR ARMOURED / PVC INSULATED ALUMINIUM CABLE WITH DOUBLE COMPRESSION FLAME PROOF TYPE BRASS GLANDING (INCLU DING COST OF GLANDS & LUGS): Providing end termination of power/control cable including cutting, stripping, providing & fixing lugs, cable insulation, providing & glanding double compression heavy duty FLAME PROOF TYPE brass cable gland conforming to IS-12943 (Dow ell's or approved equivalent), wherever specified, providing aluminium lugs, crimping/soldering, as necessary, restoration of insula tion/clamping of cable, tagging with aluminium tag,earthing of armour, connection to the equipment terminals etc. all complete with labour and materials as per standard and direction of the Engineer-in- charge: : 12 x 2.5 sqmm LT control cables with copper lugs
12LT CABLE END TERMINATION FOR ARMOURED / PVC INSULATED ALUMINIUM CABLE WITH DOUBLE COMPRESSION FLAME PROOF TYPE BRASS GLANDING (INCLU DING COST OF GLANDS & LUGS): Providing end termination of power/control cable including cutting, stripping, providing & fixing lugs, cable insulation, providing & glanding double compression heavy duty FLAME PROOF TYPE brass cable gland conforming to IS-12943 (Dow ell's or approved equivalent), wherever specified, providing aluminium lugs, crimping/soldering, as necessary, restoration of insula tion/clamping of cable, tagging with aluminium tag,earthing of armour, connection to the equipment terminals etc. all complete with labour and materials as per standard and direction of the Engineer-in- charge: : 16 x 2.5 sqmm LT control cables with copper lugs
13LT CABLE END TERMINATION FOR ARMOURED / PVC INSULATED ALUMINIUM CABLE WITH DOUBLE COMPRESSION FLAME PROOF TYPE BRASS GLANDING (INCLU DING COST OF GLANDS & LUGS): Providing end termination of power/control cable including cutting, stripping, providing & fixing lugs, cable insulation, providing & glanding double compression heavy duty FLAME PROOF TYPE brass cable gland conforming to IS-12943 (Dow ell's or approved equivalent), wherever specified, providing aluminium lugs, crimping/soldering, as necessary, restoration of insula tion/clamping of cable, tagging with aluminium tag,earthing of armour, connection to the equipment terminals etc. all complete with labour and materials as per standard and direction of the Engineer-in- charge:: 19 x 2.5 sqmm LT control cables with copper lugs
14Cable Laying Laying of all type of cables LT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cable rac ks, in trays, in protective pipes, poles,columns, in conduits, in panels and on structures etc.;including the supply and installatio n of all required materials such as fixing clamps ,screws, cable straps, tags etc. as required (other than the supply of the conduit s, cables, pipes, cable racks, trays, poles, structures and panels) complete in all respect, including cost of all labour, tools, co nsumable materials etc. and cutting the cables in required lengths as per drawings, specification and directions of Site Engineer / Engineer-in-Charge : Upto 20 MM dia
15CABLE LAYING : Laying and testing after laying of all type of owner supplied cables (PVC/XLPE/ Armoured/ Unarmoured/ Power control) in trenches, in cable racks, in trays in protective pipes, in poles, on structure, in columns, in conduits, in panels, etc. includin g supply and installation of all required materials such as fixing clamps, screws, cable straps, tags etc. as required (other than t he supply of the conduits, cables, pipes, cable racks, trays, poles, structures and panels), equipments and labour as per specificat ions, drawings and directions of Engineer-in-charge/ site engineer. Cable length shall be measured after laying - 20 to 40 MM dia
16CABLE LAYING : Laying and testing after laying of all type of owner supplied cables (PVC/XLPE/ Armoured/ Unarmoured/ Power control) in trenches, in cable racks, in trays in protective pipes, in poles, on structure, in columns, in conduits, in panels, etc. includin g supply and installation of all required materials such as fixing clamps, screws, cable straps, tags etc. as required (other than t he supply of the conduits, cables, pipes, cable racks, trays, poles, structures and panels), equipments and labour as per specificat ions, drawings and directions of Engineer-in-charge/ site engineer. Cable length shall be measured after laying - 40 to 60 MM dia
17CABLE LAYING : Laying and testing after laying of all type of owner supplied cables (PVC/XLPE/ Armoured/ Unarmoured/ Power control) in trenches, in cable racks, in trays in protective pipes, in poles, on structure, in columns, in conduits, in panels, etc. includin g supply and installation of all required materials such as fixing clamps, screws, cable straps, tags etc. as required (other than t he supply of the conduits, cables, pipes, cable racks, trays, poles, structures and panels), equipments and labour as per specificat ions, drawings and directions of Engineer-in-charge/ site engineer. Cable length shall be measured after laying - above 60 MM dia
18Cable Laying - Laying of all type of cables LT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cable r acks, in trays, in protective pipes, poles, columns, in conduits, in panels and on structures etc.; including the supply and install ation of all required materials such as fixing clamps, screws, cable straps, tags, etc. as required (other than the supply of the co nduits, cables, pipes, cable racks, trays, poles, structures and panels) complete in all respect, including cost of all labour, tool s, consumable materials, etc. and cutting the cables in required lengths as per drawings, specification and directions of Site Engin eer / Engineer-in-Charge: Control cables (T&I) : OD upto 20 mm
19Cable Laying - Laying of all type of cables LT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cable r acks, in trays, in protective pipes, poles, columns, in conduits, in panels and on structures etc.; including the supply and install ation of all required materials such as fixing clamps, screws, cable straps, tags, etc. as required (other than the supply of the co nduits, cables, pipes, cable racks, trays, poles, structures and panels) complete in all respect, including cost of all labour, tool s, consumable materials, etc. and cutting the cables in required lengths as per drawings, specification and directions of Site Engin eer / Engineer-in-Charge: Control cables (T&I) : OD above 20 mm and upto 30 mm
20Cable Laying - Laying of all type of cables LT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cable r acks, in trays, in protective pipes, poles, columns, in conduits, in panels and on structures etc.; including the supply and install ation of all required materials such as fixing clamps, screws, cable straps, tags, etc. as required (other than the supply of the co nduits, cables, pipes, cable racks, trays, poles, structures and panels) complete in all respect, including cost of all labour, tool s, consumable materials, etc. and cutting the cables in required lengths as per drawings, specification and directions of Site Engin eer / Engineer-in-Charge: Control cables (T&I) : OD above 30 mm and upto 40 mm
21Supplying and laying reinforced cement concrete light duty hume pipe, non pressure type (NP3), centrifugally cast conforming to I.S. 458 with 1:3:6 concrete casing at joints as required with necessary slope including excavation, backfilling, supply of collars, join ting of pipes with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement: 2 fine sand), testing of joints, complete in all respects as per specifications, drawing and the direction of the EIC/Site Engineer: 300 mm dia
22EARTH STRIP / WIRE / ROPE / CABLE - Supply, installing and testing of earthing strip/wire/rope/cable for completely making the earth ing grid system by supplying, laying the GI / Cu strip and making all the necessary welding joints, connecting to the earthing elect rodes and existing earthing grid etc., complete as per drawings, specifications and directions of the Site engineer/Engineer-in-char ge, including the cost of all labour, tools, materials, etc. complete in all respect: : 40 mm X 5 mm G.I. earthing strip
231:1.5:3 [1 cement : 1.5 coarse sand (Zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived fr om natural sources]
241:4:8 [1 cement : 4 coarse sand (Zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from n atural sources]
25Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto pli nth level : Thermo-Mechanically Treated bars of grade Fe-500D or more
26Supplying steel structural items at site such as joists, tubes, pipes, channels, angles, beams, plates, flats, square/ rectangular h ollow sections, bars, MS gratings, chequered plates, C.I. Rollers, bolts & nuts, washers, grouting/ foundation bolts, etc., fabricat ion and erection/fixing of structures such as saddle supports, pipe supports, valve supports, platforms, walkways, stairways, crosso vers, struts, chain link fencing posts, gate, collapsible gate, ladders, safety grills, signboards, supports for cable trench, cable racks, cable tray support, push button control posts, supporting structures etc. as per drawing including drilling holes, making sl ots for barbed line, wire hoisting, placing in position, embedding in concrete etc. including surface preparation using abrasive bla st cleaning or power tools cleaning, priming and painting the finished structure by applying one coat of High Build Epoxy Zinc Phosp hate Primer (min. 50 µm), one coat of Self-primed, surface tolerant, High build Epoxy mastic (min. 150 µm) and one finish coat of Is ocyanate Aliphatic Poly-Urethane(PU) Finish Paint (min. 50 µm) (Total DFT: 250 µm), including supply of all inputs such as labour, m aterials, consumables, tools and tackles, welding electrodes, paints of approved make as per vendor list in the tender,cutting to re quired size welding of joints, fixing anchor plates,bolts, theading, nuts, washers, sleeves etc. and necessary lettering of approved pattern on main gate, signboards etc. necessary to perform and complete the work in all respect, in accordance with drawings, speci fications and instructions of the Site Engineer/ EIC. Note: This item is excluding the cost of concrete work.
27Supply, installation & fixing of prefabricated perforated GI cable trays with tray cover of width 150 mm, 300 mm, 450 mm & 600 mm as per site requirement for laying of cables with standard rung spacings. Load for support span of 2.5 meter as 30, 60, 75 & 90 (in Kg /Mtr) respectively with concentric static load as 70 Kg at the centre, with materials, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge.
28Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas including trimming of sides of the trenc hes, dressing, ramming and levelling the bottom of the trenches correct to level, grade etc. including filling in sides of foundatio n trenches, plinth etc. with the excavated earth available and/or depositing the excess earth within station area limits, in layers not exceeding 20 cms. thick, consolidating each deposited layer by ramming, watering, dressing to level and grade , complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of Site Engineer.
29WBM Road/concrete breaking for cable trenches including required shoring strutting etc., and repairing of the road/dyke to original condition and disposing off excess materials (within the work site) job complete in all respects including the cost of labour, tools , materials, load, lift hire charges of equipments, if any, complete as per drawings, specification and directions of Site Engineer / Engineer-in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57092128
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 3.67 Crore
LAST DATE 02-09-2026
Authority
Authority Name Indian Oil Corporation Limited
Work Description Tender for Replacement Of Existing Underground Power & Controls Cables With Above Ground Cables, Including The Supply & Installation Of The Cable Trays, And Associated Civil & Mechanical Works At Wrpl, Mundra Station.
Basic Detail
Tender No PWRJT26604
Bidding Type Tender
Location
City Kachchh
State Gujarat
Key Dates
Publish Date 19 Aug 2026
Submission Date 02 Sep 2026
Open Date 03 Sep 2026
Finance
Tender Value 3.67 Crore
Tender Fee Ref. Documents
EMD 92000
Exemption Not Available
Document List
Annexure.rar
Annexure.xls
Bidders_help_Document_for_1.pdf
BOQ_201340.xls
f0d7960e-d3e2-4091-8501-76ec55a98d0f.html
FAQs-IOCL-Online-EMD.pdf
PWRJT26604.pdf
Special_Instructions_to_t_2.pdf
TechSpecs.pdf
Tender-Acceptance-Format.pdf
Tendernotice_1 (18).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Sep 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
rar

Annexure.rar

xls

Annexure.xls

pdf

Bidders_help_Document_for_1.pdf

xls

BOQ_201340.xls

html

f0d7960e-d3e2-4091-8501-76ec55a98d0f.html

pdf

FAQs-IOCL-Online-EMD.pdf

pdf

PWRJT26604.pdf

pdf

Special_Instructions_to_t_2.pdf

pdf

TechSpecs.pdf

pdf

Tender-Acceptance-Format.pdf

pdf

Tendernotice_1 (18).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders