Defence Statutory Bodies & Commissions/Committees Closing in 20 days TDR #57091631

Tender For Repair To Electrical Supply And Repair To E/M Installation Of Zone A And B At Af Stn Bikaner

Issued by Statutory Bodies & Commissions/Committees · Bikaner, Rajasthan
Tender Value
29.99 Lakhs
Estimated cost
Bid Submission
09 Sep 2026
20 days left
EMD
59980
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bikaner → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair To Electrical Supply And Repair To E/M Installation Of Zone A And B At Af Stn Bikaner

BOQ

Name of Work:- REPAIR TO ELECTRICAL SUPPLY AND REPAIR TO E/M INSTALLATION OF ZONE A AND B AT AF STN BIKANER
Sl. No. Item Description
1Dismantling and taking out the old stay assembly complete including demolition of plain cement concrete foundation complete all as specified and directed. Note : (i) Unit rate of this item includes the loose/disconnect the all accessories which are connected to stay assy includng necessary excavation as directed. (ii) Existing stay assy are fixed on the LT/HT pole of PCC or steel tubular pole, nothing extra shall be paid on this account.
2Material and Labour for Stay assembly complete with accessories as shown in electrical plate No 1 including GI Adjustable Stay Rod of 16 mm Dia, GI Stay wire of size 7/4 mm incl stay clamps, loop type insulator, excavation in any strata and PCC 1:3:6 concrete all as specified and directed. Note:- Unit rate of this item includes the cost of earthwork, loop type insulator, PCC and stay wire.
3Material and labour for painting with synthetic enamel paint of two coats of post office red/white paint on HT PCC pole upto 1.5mtr height from coping in alternative red and white, strip of 30cm each and writing pole numbers with black paint.
4All as per item No 03 above but for two pole structure and altenatively red and white strips on HT pole
5All as per item No 03 above but for four pole structure and altenatively red and white strips on HT pole
6Material and labour for painting with two coats of synthetic enameled paint on PCC pole upto 1.5 mtr above the GL in alternatively black and white strap of 30 cm each after scrapping/removing the existing paint and the preparation the surface of PCC LT pole complete.
7Material and labour for painting above the copping upto 1.5 mtr in alternatively black and white strips of 30 cm each & rest of the portion with two coats of silver/aluminium paint on steel tubular LT pole of any height after scrapping/removing the existing paint and the preparation the surface of steel tubular pole LT including painting of the channel cross arms, nut, bolts & washer, street light bracket and clamps complete all as specified and directed
8Material and Labour for removing old stone aggregate of any size from 4 pole structures and resurfacing with new stone aggregate 40mm after making good to the existing surface upto 15cm height complete all as spefied and directed
9Taking down/removing all connections of four pole structure including all jumpers and complete rejumpering using new ACSR connectors of adequate length and connections using aluminium lugs/sleeves of directed sizes and treating with conducting jelly and testing of structure before charging with electric supply all to the satisfaction of Engr in charge.
10Supply, install, test and commission LT feeder pilar box/panel board, outdoor type, fabricate with 3.15mm CRCA sheet mounted on 50x50x6mm MS angle, 3 phase 4 wire, 440v, AC, 50 Hz, with TPN aluminium bus bar of capacity 400 Amps with pvc heat shrink colour code sleeves, mounted on porcelin insulators complete volt and amp meter, selecter switch with all accessories and consist of the foloowing switch gear: -(a) Aluminium bus bar 3 phase & neutral of capacity 200 Amps (b) Onload change over switch 125A, 4P(c) MCCB 4P 125 Amps (16KA) - 01 No Incomer(c) MCCB 4P 63 Amps (16KA) - 03 No Out going(e) MCB TPN 40Amps (10KA) - 01 Nos(j) RYB Phase Indication lamp(k) Digital voltmeter and AmmeterNote : Unit rate of this item also includes the following :- (a) For fixing the Panel excavation, earthwork and PCC work involved shall be carried out by the contractor as directed. (b) After errection / fixing of panels, all connection shall be made by the contractor as directed.(c) Including taking down exisiting LT panel.
11M&L as in repairs lightning Arrestor Expulsion type Transmission Class 65 Kilo Amps 11000 V Grade incl connecting complete all as specified and directed.
12Shifting of Transformers upto 630 KVA from one substation to other sub station in the case of any breakdowns by using man power and mechanical means after disconnecting all electric connections and reconnecting in new locations within 263 SU area as directed. Note : (i) Contractor shall provide all the T & P including transportation for shift and nothing extra shall be paid on account of loss of manpower during shift. Tenderer is hereby advised to keep in mind this factor before quoting his rates.
13Supply and fix in repairs GI strip 32mm x 6mm burried in ground / laid in floor / fixed to wall on saddles / on porcelain insulators etc complete all as specified and directed. Note : Excavation and earthwork shall be measured and paid for separately.
14Material and labour as in repair earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick, buried directly in ground, vertically to a depth not less than 2.25 mtr deep below ground level with top edge of the earth plate at depth not less than 1.5 mtr below ground level earth plate surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, earth lead GI strip 32mmx6mm by means of bolts, nuts, check-nuts and washers of galvanized iron and thimbles and of earth wire protected by galvanized iron pipe light grade 40mm bore and water pipe 20 mm bore GI medium grade with funnel and wire mesh complete including excavation and earth work, PCC chamber and cover in cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate in lieu of CI cover and frame etc all as specified and shown in electrical plate No. 3 of SSR-2009 (Part-I).
15Supply and fixing as in repairs MCCB of 63 Amps , 4 pole, 415 volts, 50 Hz, rupturing capacity 16 KA, connection with proper size of thimbles complete all as specified and directed.
16Supply and fixing as in repairs MCCB of 100 Amps , 4 pole, 415 volts, 50 Hz, rupturing capacity 16 KA, connection with proper size of thimbles complete all as specified and directed.
17Supply and fix as in repairs MCCB, 125A, rupturing capacity 16 KA , 415 volts 4 pole complete all as specified & directed.
18Supply and fix as in repairs MCCB, 160A, rupturing capacity 16 KA, 415 volts 4 pole complete all as specified & directed.
19Supply and fix as in repairs MCCB, 200A, rupturing capacity 16 KA, 415 volts 4 pole complete all as specified & directed.
20Supply and fix as in repairs MCCB, 250A, rupturing capacity 25 KA, 415 volts 4 pole complete all as specified & directed.
21Supply and fix as in repairs MCCB, 400A, rupturing capacity 25 KA, 415 volts 4 pole complete all as specified & directed.
22Supply, install, test and commission LT feeder pilar box/panel board, outdoor type, fabricate with 3.15mm CRCA sheet mounted on 50x50x6mm MS angle, 3 phase 4 wire, 440v, AC, 50 Hz, with TPN aluminium bus bar of capacity 400 Amps with PVC heat shrink colour code sleeves, mounted on porcelin insulators complete volt and amp meter, selecter switch with all accessories and consist of the foloowing switch gear: -(a) Aluminium bus bar 3 phase & neutral of capacity 400 Amps (b) MCCB 4P 250 Amps (25KA) - 01 No Incomer(c) MCCB 4P 100 Amps (25KA) - 03 No Out going(e) MCCB 4P 63 Amps (16KA) - 02 No Out going(j) RYB Phase Indication lamp(k) Digital voltmeter and AmmeterNote : Unit rate of this item also includes the following :- (a) For fixing the Panel excavation, earthwork and PCC work involved shall be carried out by the contractor as directed. (b) After errection / fixing of panels, all connection shall be made by the contractor as directed.(c) including taking down existing LT panel.
23M&L trimming of tree branches on both sides of LT alminium conductor overhead complete all as specified and directed. NOTE : (i) Cutting branches shall be dumped in specified locaton as directed by Engr-in-Charge.(ii) Contractor shall provide the ladder of required size including T&P to his worker and nothing extra shall be paid on this account.
24Supplying and laying as in repairs GI tubing light grade incl all accessories for passing of cables for mechanical proctection, laid under Plinth / Floors/ Paths Culverts or fixed on wall or concealed in wall / floor or along poles or as street light poles or as street light mounting bracket with complete accessories such as bends / sockets / reducers / saddles incl necessary threading / drilling works all as specified and directed. (MS works including painting will be measured under seperate item in Schedule)
25(a) 80 mm bore
26(b) 50 mm bore Please Enable Macros to View BoQ information
27(b) 50 mm bore Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57091631
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 29.99 Lakhs
LAST DATE 09-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair To Electrical Supply And Repair To E/M Installation Of Zone A And B At Af Stn Bikaner
Basic Detail
Tender No C/81673/E8
Bidding Type Tender
Location
City Bikaner
State Rajasthan
Key Dates
Publish Date 19 Aug 2026
Submission Date 09 Sep 2026
Open Date 11 Sep 2026
Finance
Tender Value 29.99 Lakhs
Tender Fee 500
EMD 59980
Exemption Available
Document List
1fb11f0c-f1c2-450d-8ab8-c05541b910be.html
BOQ_879796.xls
Tenderdocuments.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Sep 11, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 22 days

Tender Documents

Download All (ZIP) ↓
html

1fb11f0c-f1c2-450d-8ab8-c05541b910be.html

xls

BOQ_879796.xls

pdf

Tenderdocuments.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders